8910-GeoNet-LoRa-DAS.pdf
PDF 604 KB Posted
- Attached to
- Notice of Intent for use of Brand Name-GeoKon Pressure Transducers with LORA and Cellular Data Loggers
- Solicitation number
- W912DW26R1B1Q
About this file
This is a product specification sheet for the GEOKON Model 8910 Series GeoNet Wireless LoRa Data Acquisition System.
The system comprises a wireless data acquisition platform utilizing LoRa radio technology in a star network topology, where data loggers communicate directly with a cellular gateway that transmits collected data to the GEOKON cloud platform via secure cellular (LTE-M/LTE) connection. The system operates on 868-928 MHz ISM band frequencies with up to 8 configurable channels, achieving ranges of up to 20 kilometers in rural open areas with line-of-sight and 5 kilometers in urban areas. Data loggers operate autonomously on 2×D cell lithium or internal sealed lead acid batteries (5-24V external power compatible), wake periodically to collect and transmit sensor data, then return to sleep to conserve battery life, and continue collecting data locally if network connectivity is lost. Available models include single and multi-channel vibrating wire data loggers, digital addressable data loggers compatible with MEMS and thermistor sensors, four-channel analog data loggers, a tilt data logger combining biaxial tiltmeter functionality, a time domain reflectometry data logger, and a Digital High Power data logger capable of reading up to 250 MEMS sensors or non-GEOKON RS-485 MODBUS sensors with custom firmware. Configuration occurs through the GEOKON API (api.geokon.com), with data visualization and management via GEOKON Agent Software or third-party platforms through the Open API. The system is housed in IP68-rated die-cast aluminum enclosures, operates across −40°C to +85°C temperature ranges, and supports LoRaWAN communication protocol for use with third-party gateways. Primary applications include groundwater monitoring, tailings dams, mining and slope stability monitoring, structural monitoring of buildings and bridges, and historical structure assessment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 8800-GNA-Agent-Software.pdf | ||
| 8921-GeoNet-Cellular-Data-Loggers.pdf | ||
| 4500_Series_VW_Piezometers.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
General Specifications
Communications
The Model 8910 GeoNet Wireless Data Acquisition utilizes LoRa radio technol-ogy. The system topology takes the form of a star network. All data loggers communicate directly with the gateway.
The data loggers wake from sleep to col-lect and/or transmit data to the gateway and then return to sleep when finished to conserve battery life. Data loggers that get separated from the network will continue to collect and store data autonomously until network connectivity is re-established, at which time the data will be transmitted to the gateway.
Up to 8 networks can exist within radio range of one another by setting each to a different operating channel.
The data loggers can also operate using LoRaWAN® communication protocol for use with LoRaWAN third-party gateways.
Configuration of the network is accomplished by using the GEOKON API (api.geokon.com).
www.geokon.com/8910-Series
INTRODUCTION
The system consists of a gateway and subordinate wireless data loggers that transmit data collected from the con-nected sensors. The gateway controls the network and is the aggregator of all the data from the data loggers in the system. The gateway transfers collected data to the GEOKON cloud data storage platform, where it is securely stored.
Data can be viewed in GEOKON Agent Software or exported to a third-party software platform through the Open API.
(Offline configurator also available.)
Model 8960 Digital Vibrating Wire interfaces can be connected to GeoNet multi-channel VW and addressable data loggers to expand the capacity of the data logger. Multiple VW interfaces can be daisy-chained together to bus the data to a single data logger. The bus limit is 32 units or 64 channels. Refer to the Model 8960 data sheet for more information.
Available models include:
Single and multichannel Vibrating wire dataloggers that are compatible with most manufacturers' VW sensors.
A digital addressable data logger compatible with GEOKON addressable MEMS, VW, and thermistor sensor strings.
A four-channel analog data logger capable of reading data from analog sensors.
A tilt data logger that combines the functionality of a biaxial tiltmeter and a GeoNet data logger.
A data logger used to read time domain reflectometry cables.
A Digital High Power data logger that can read up to 250 GEOKON MEMS sensors. With custom firmware, it is capable of reading non-GEOKON sensors that utilize RS-485 MODBUS communication protocol.
Applications
Typical applications include:
� Groundwater monitoring
� Tailings dams
� Mining/slope stability
� Structural monitoring of buildings, bridges, excavations, and tunnels
� Historical structures
The GeoNet Wireless LoRa Data Acquisition System: a typical network configuration of data loggers, a cellular gateway and cloud integration with secure data access
Model 8910 Series
GEONET WIRELESS LoRa®
DATA ACQUISITION SYSTEM
Cellular Gateway geokon® server + openapi
Secure Cellular
(LTE-M/LTE)
Secure data access and visualization via geokon agent software or optional third party softwareTilt
Data Logger
Eight-Channel VW Data Logger
Addressable Data Logger
Topology Star
Radio Technology LoRa/LoRaWAN
Radio Frequency, ISM Band 868-928 MHz (user selectable masking by region)
Channels 8 (4 auto configurable)
Range1 Up to 20 km in rural open areas with line-of-sight Up to 5 km in urban areas
1Outdoor, clear line-of-sight. Depends on operating frequency.
Network Specifications
Power Supply DHP, GTW & TDR models: Internal sealed lead acid (SLA) battery pack, 4V, 10 Ah / 5-24V external All other models: 2× D cell, lithium / 5-24V external
Operating Temperature −40 °C to +85 °C (range varies by power source) (TDR model −20 °C to +70 °C (TLT model max of +65 °C)
Temperature Accuracy ±0.5° C
Direct Connection Type USB
Enclosure Die-cast aluminum, IP 68 rated to 1.5 m
Dimensions Refer to the product instruction manual geokon 48 Spencer Street Lebanon, NH 03766 • USA www.geokon.com e: teamsales@geokon.com p: + 1 · 603 · 448 · 1562 geokon is an iso 9001:2015 registered company
The geokon ® logo and word mark are registered trademarks with the United States Patent and Trademark Office. | geokon maintains an ongoing policy of design review and reserves the right to amend products and specifications without notice. | The LoRa® Mark is a trademark of Semtech Corporation or its subsidiaries. | LoRaWAN® is a registered trademark of the LoRa Alliance.® Modbus is a registered trademark of SCHNEIDER ELECTRIC USA, INC. | All other trademarks are the property of their respective owners.
Not all models are CE approved. Contact geokon for details.
©geokon. All Rights Reserved. | Rev-B.2-01/28/2026
ACCESSORIES
8900-SOL-10W-USB: GeoNet Series Solar Panel, 10W, unregulated.
KIT-GEONET-C-T20: USB 2.0 A Male to C Male Cable and T20 screwdriver.
BAT-202: Lithium D size battery, 17 Ah
COM-169: USB 2.0 A Male to C Male Cable TDR-PIGTAIL: Pigtail cable required to connect TDR-CBL cable to 8910- TDR logger
8910-01C Single-Channel VW Data Logger
8910-TLT
Tilt Data Logger
8910-DHP
Digital High Power Data Logger
8910-08C Eight-Channel VW Data Logger
8910-ADR
Addressable Data Logger
AVAILABLE MODELS
8910-GTW
Cellular Gateway
Vibrating Wire data Logger Specifications
Trueness 0.082 Hz
Frequency Precision ±0.146 Hz (99% CI)
Frequency Resolution ±0.002 Hz
VW Frequency Range 400 – 6,500 Hz
Range1 ±90°
Resolution 2 0.00025° (0.004 mm/m)
Precision 3 ±0.0075° (±0.13 mm/m)
Nonlinearity ±0.005° across ±30° range (±0.09 mm/m)
Temperature Dependent Uncertainty
±0.001° across ±5° angular range (±0.016 mm/m) ±0.0016° across ±15° angular range (±0.026 mm/m) ±0.0026° across ±30° angular range (±0.042 mm/m)
Axes 2
1 Calibrated Range: ±30° 2 99% confidence interval (i.e. 99 out of 100 individual readings fall within this tolerance).
3 Includes random walk (changes in consecutive readings with no discernible cause) and seismic noise during testing.
TILT data Logger Specifications
MEMS Sensors Limits per Model
Non-rechargeable ADR: 32 sensors Rechargeable ADR: 64 sensors (90 sensors, with the sensor string powered via external 12 V power supply) DHP: 250 sensors
Communication Protocol RS-485 Modbus
Digital DATA Logger Specifications
8910-ANA
Four-Channel Analog Data Logger
Pulse Generator Output 0 – 5V
Output Impedance 50 ohm
Pulse Length Variable (1 – 70 ns)
Waveform Averaging 1
Range 4000m 100% VOP
Resolution 15 cm x VOP/100
Current 250mA During Measurement
Pigtail Cable 50 ohm RG-8X 84% VOP Coaxial
Sensor Cable 50 ohm 1/2" 88% VOP Coaxial
TIME DOMAIN REFLECTOMETRY DATA LOGGER sPECIFICATIONS
Analog DATA Logger Specifications
Channels 4 lnput Type mV, V, mA, Ω lnput Range (individually configurable)
0 – 150 mV, 0 – 500 mV, 0 – 1 V, 0 – 5 V, 0 – 10 V, 0 – 15 V, ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, ±15 V, ±20 mA, 0 – 20 mA, 4 – 20 mA
Voltage Mode Accuracy ±0.1% or better
Current in Mode ±0.2% or better
Resolution 16-bit
Zero Drift ±6 μV/°C
Span Drift ±25 ppm/°C (typical)
CMR @ 50/60 Hz 92 dB min.