Tab 04 SOW.pdf

PDF 155 KB Posted

Attached to
Platinum and Platinum‐Rhodium Sputtering Targets
Solicitation number
80NSSC875124Q2
Issued by

About this file

This document is a Statement of Work (SOW) for the procurement of a Platinum sputtering target and a Platinum-Rhodium sputtering target to support NASA Glenn Research Center's harsh environment detector effort for fission surface power applications.

The SOW specifies that the Platinum sputtering target shall have a composition of 100% Platinum with a minimum purity of 99.99%, and dimensions of 3.00" diameter by 0.250" thick. The Platinum-Rhodium sputtering target shall have a composition of 90wt% Platinum and 10wt% Rhodium with a minimum purity of 99.95%, and the same dimensions. A Certificate of Compliance is required for each target. The delivery location is the Glenn Research Center Sensors & Electronics Branch in Cleveland, Ohio.

The related federal contract opportunity is Solicitation Number 80NSSC875124Q2, issued by the National Aeronautics and Space Administration Shared Services Center, a civilian agency. The solicitation is for the procurement of the Platinum and Platinum-Rhodium sputtering targets described in the SOW.

View the file

Other files

File Type Posted
Tab 12 RFQ 80NSSC875124Q2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Platinum and Platinum‐Rhodium Sputtering Targets

Statement of Work (SOW)

To support NASA Glenn Research Center’s harsh environment detector effort for fission surface power applications, the Smart Sensing and Electronics Systems branch requires a Platinum sputtering target and a Platinum‐Rhodium sputtering target. The sputtering targets shall have the specifications as follows:

Platinum Sputtering Target

Quantity: 1

Composition: Pt (100%)

Purity: 99.99% minimum

Dimensions: 3.00” diameter by 0.250” thick ±0.010”

Platinum‐Rhodium Sputtering Target

Quantity: 1

Composition: Pt 90wt% + Rh 10wt%

Purity: 99.95% minimum

Dimensions: 3.00” diameter by 0.250” thick ±0.010”

A Certificate of Compliance for each target is required.

Delivery Location:

Glenn Research Center Sensors & Electronics Branch 21000 Brookpark Rd Cleveland, OH 44135