This is a Statement of Work (SOW) for tensile and high cycle fatigue testing of aerospace materials, dated October 29, 2026.

Tension Testing: NASA will supply sheet mechanical test specimens in batches of 18 to 48 specimens over a 12-24 month period, totaling 252 specimens across Ni-based, Ti-based, and Nb-based alloys. Testing shall conform to ASTM E8 and E21 standards, utilizing a two-segment displacement rate protocol (0.005 in/min. for the first segment, 0.056 in/min. for the second). Specimens must be heated using resistive element furnaces with thermocouples in contact with or proximate to the gage section; induction-based heating is permitted only with an approved susceptor design. Testing will be conducted across 11 temperature points ranging from room temperature to 2300°F, with specimen quantities varying by temperature (6 to 36 specimens per temperature). Deliverables include failed specimens returned with fracture halves separately wrapped, a summary table containing modulus, 0.2% yield strength, ultimate strength, strain at fracture, and percent reduction in area for each specimen, and Excel or CSV data files documenting incremental time, temperature, stress, strain, and displacement.

High Cycle Fatigue Testing: NASA will supply sheet mechanical test specimens in batches of 28 to 56 specimens over 12-24 months for testing according to ASTM E466. Testing involves two different Nb-based alloys in a servo-hydraulic load frame under load control at 10-30 Hz, with specimen runout determined at 24 hours or upon achievement of a fixed cycle count. Specimens shall be heated by resistive element furnaces with thermocouples, maintaining a thermal gradient of ±5°C across the gage section; induction heating is permitted only with an approved susceptor. The contract includes 100 hours of additional test time at 2200°F. High cycle fatigue testing involves 56 specimens at 2200°F. Deliverables include failed specimens with separately wrapped fracture halves and summary tables documenting cycles to failure, failure location, specimen measurements, frequency, and test time. Failed specimens from both testing phases shall be shipped to NASA Glenn Research Center, Cleveland, Ohio.

View the file

Other files

File Type Posted
SATPC0043276 Tab 07 Capability Statement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOW Tensile and High Cycle Fatigue Testing

10/29/2026

1 Tension Testing

1.1 Overview:

• NASA will supply sheet mechanical test specimens as per the attached drawing to be tensile tested according to ASTM E8 and E21

• Material will vary over Ni-based, Ti-based, and Nb-based alloys.

1.2 Batches:

• Batches of specimens will be shipped by NASA periodically over 12-24 months.

• Batches will be a minimum of 18 specimens at a time. The maximum number of specimens at a time will be around 48 specimens in a batch.

• The total number of specimens will be 252.

1.3 Test Procedures:

For each test, with the extensometer measuring strain, the first segment shall be conducted with displacement rate controlled at 0.005 in/min. to produce the required strain rate of approximately 0.5%/min. The second segment shall then be conducted at a displacement rate of 0.056 in/min.

1.4 Additional requirements:

• Specimens shall be heated by a resistive element furnace, with thermocouples in contact with the specimen, or sufficiently close to the gage section.

o Induction-based heating techniques shall only be permitted with a susceptor. Susceptor material and design shall be included in the quote.

• Temperature variation and control will be within the limits permitted in ASTM E21

• Strain measurement technique shall be proposed by the vendor and discussed subsequently with NASA.

• No gage marks will be applied within the reduced sections of specimens to be tested.

• Specimen fixturing method (e.g. tabs) will be discussed.

• Specimen drawing can be modified to account for gripping specifics.

1.5 Deliverables:

• Failed specimens shall be returned to NASA, each specimen half separately wrapped and isolated in paper, so the fractured halves are never in direct contact.

Do not join the two specimen fracture halves together to measure elongation.

• Summary table containing modulus, 0.2 % yield strength, ultimate strength, strain at fracture, and % reduction in area shall be provided by the vendor for each tested specimen.

• Excel or CSV file of the data acquisition for each test, including at least incremental time, temperature, stress, strain, and displacement.

1.6 Quantity:

Temperature (°F) Number of specimens

RT 36

600 6 800 24 1000 6 1200 36 1400 6 1600 30 1800 12 2000 30 2100 24 2300 6 reserve 36 total 252

Temperatures may be subject to change with agreement from NASA and test house

2 High Cycle Fatigue

2.1 Overview:

• NASA will supply sheet mechanical test specimens based on the attached drawing to be tested in High Cycle Fatigue (HCF) according to ASTM E466.

• Material will be 2 different Nb-based alloys.

2.2 Batches:

• Batches of specimens shall be shipped periodically over 12-24 months.

• Batches shall be a minimum of 28 specimens at a time. The maximum number of specimens at a time shall be around 56 specimens in a batch.

2.3 Test Procedures:

• Specimens shall be tested in a servo-hydraulic load frame.

• Specimens shall be tested in load control at an agreed upon frequency, e.g. 10-30

Hz.

• Specimen runout shall be determined at 24 hours test run time, or a fixed number of cycles achieved in less than 24 hours.

• Include in the quote 100 hours of additional test time at 2200°F in the quote

2.4 Additional requirements:

• Specimens shall be heated by a resistive element furnace, with thermocouples in contact with the specimen, or sufficiently close to the gage section.

• Induction-based heating techniques shall only be permitted with a susceptor.

Susceptor material and design shall be included in the quote.

• Thermal gradient shall be ± 5 °C (9 °F) of the homologous test temperature across the gage section of the specimen.

• Fixturing methods will be discussed in quote, and modifications to the test specimen will be discussed if needed.

2.5 Deliverables:

• Failed specimens shall be returned to NASA, each specimen half separately wrapped and isolated in paper, so the fractured halves are never in direct contact.

Do not join the two specimen fracture halves together.

• Summary table including cycles to failure, failure location, and specimen measurements, frequency, test time, etc. shall be provided for each HCF test completed.

2.6 Quantity:

Temperature (°F) Number of specimens 2200 56

Temperatures may be subject to change with agreement from NASA and test house.

3 Shipping information

3.1 Shipping Information

Failed specimens will be shipped to POC.

NASA Glenn Research Center

21000 Brookpark Rd

Cleveland, OH 44145

1 Tension Testing
1.1 Overview:
1.2 Batches:
1.3 Test Procedures:
1.4 Additional requirements:
1.5 Deliverables:
1.6 Quantity:
2 High Cycle Fatigue
2.1 Overview:
2.2 Batches:
2.3 Test Procedures:
2.4 Additional requirements:
2.5 Deliverables:
2.6 Quantity:
3 Shipping information
3.1 Shipping Information

File details come from the government source that posted it. Updated .