SATPC0043132 Tab 04 4 Specs.pdf

PDF 135 KB Posted

Attached to
10x10TransData unit replacements
Solicitation number
80NSSC27948290Q
Issued by

About this file

This document is a specifications sheet for four TransData transducer units required as of October 20, 2026.

The solicitation specifies procurement of four distinct transducer items with detailed technical requirements. Item 1 is a Current Transducer with 45 electrical elements, operating range of -20°C to 70°C, 0-95% humidity tolerance, 100-130V 60 Hz power supply, 50-70 Hz frequency range, 5 Amps full scale input, 4-20mA DC output, response time under 400ms, 5000V peak surge withstand capability, and ±0.2% accuracy at 25°C ±5°C. Item 2 is a Voltage Transducer with identical specifications to Item 1 except featuring 30 electrical elements instead of 45. Item 3 is a Wattage 2-Element Transducer with 10 wiring terminals, three-phase operation (versus single-phase for Items 1-2), 120V 60 Hz power supply, 0-99% non-condensing humidity tolerance, tighter accuracy of ±0.1% at 25°C ±2°C, and no zero adjustment requirement. Item 4 is a Wattage 2.5-Element Transducer with 5 wiring terminals featuring identical specifications to Item 3, including three-phase operation and ±0.1% accuracy. All four items require utility-specified steel enclosures, standardized mounting footprints, ±10% calibration adjustment capability, and 5 Amps full scale input with 4-20mA DC output.

View the file

Other files

File Type Posted
SATPC0043132 Tab 07 Capability Statement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10x10 TransData units 10/20/2026

1.0 Current Transducer Specifications (Item 1):

1.1.1 Number of Electrical Elements: 45

1.1.2 Temperature Range: -20 degrees C to 70 degrees C

1.1.3 Operating Humidity: 0-95%

1.1.4 Power Supply: 100-130V, 60 Hz

1.1.5 Frequency Range: 50-70 Hz

1.1.6 Full Scale Input: 5 Amps

1.1.7 4-20mA DC output

1.1.8 Response Time to 99%: <400 MS

1.1.9 Surge Withstand Capability: 5000V Peak

1.1.10 Accuracy @ 25 degrees C +/- 5 degrees C: +/-0.2% of rated output

1.1.11 Single phase

1.1.12 Calibration Adjustment: +/-10%

1.1.13 Zero (offset) Adjustment: +/- 5%

1.1.14 Utility specified steel enclosure

1.1.15 Standardized mounting footprint

2.0 Voltage Transducer Specifications (Item 2):

2.1.1 Number of electrical elements: 30

2.1.2 Temperature Range: -20 degrees C to 70 degrees C

2.1.3 Operating Humidity: 0-95%

2.1.4 Power Supply: 100-130V, 60 Hz

2.1.5 Frequency Range: 50-70 Hz

2.1.6 Full Scale Input: 5 Amps

2.1.7 4-20mA DC output

2.1.8 Response Time to 99%: <400 MS

2.1.9 Surge Withstand Capability: 5000V Peak

2.1.10 Accuracy @ 25 degrees C +/- 5 degrees C: +/-0.2% of rated output

2.1.11 Single phase

2.1.12 Calibration Adjustment: +/-10%

2.1.13 Zero (offset) Adjustment: +/- 5%

2.1.14 Utility specified steel enclosure

2.1.15 Standardized mounting footprint

3.0 Wattage 2-Element Transducer Specifications (Item 3):

3.1.1 Number of wiring terminals: 10

3.1.2 Temperature Range: -20 deg C to 70 deg C

3.1.3 Operating Humidity: 0-99% non-condensing

3.1.4 Power Supply: 120V, 60 Hz

3.1.5 Frequency Range: 50-70 Hz

3.1.6 Full Scale Input: 5 Amps

3.1.7 4-20mA DC output

3.1.8 Response Time to 99%: <400 MS

3.1.9 Surge Withstand Capability: 5000V Peak

3.1.10 Accuracy @ 25 degrees C +/- 2 deg C: +/-0.1% of rated output

3.1.11 Three phase

3.1.12 Calibration Adjustment: +/-10%

3.1.13 Zero Adjustment: none required

3.1.14 Utility specified steel enclosure

3.1.15 Standardized mounting footprint

4.0 Wattage 2.5-Element Transducer Specifications (Item 4):

4.1.1 Number of wiring terminals: 5

4.1.2 Temperature Range: -20 deg C to 70 deg C

4.1.3 Operating Humidity: 0-99% non-condensing

4.1.4 Power Supply: 120V, 60 Hz

4.1.5 Frequency Range: 50-70 Hz

4.1.6 Full Scale Input: 5 Amps

4.1.7 4-20mA DC output

4.1.8 Response Time to 99%: <400 MS

4.1.9 Surge Withstand Capability: 5000V Peak

4.1.10 Accuracy @ 25 degrees C +/- 2 deg C: +/-0.1% of rated output

4.1.11 Three phase

4.1.12 Calibration Adjustment: +/-10%

4.1.13 Zero Adjustment: none required

4.1.14 Utility specified steel enclosure

4.1.15 Standardized mounting footprint

10x10 TransData units 10/20/2026

File details come from the government source that posted it. Updated .