SATPC0042989 Tab 04 4 SOW.pdf
PDF 124 KB Posted
- Solicitation number
- 80NSSC26946607Q
About this file
This is a Statement of Work for thermal properties testing of lunar regolith simulant material. The contractor shall gather thermal properties of ICN-LHT-1G lunar regolith simulant at a bulk sample density of 1.5 to 1.6 grams per cubic centimeter using two standardized test methods: ASTM E1461 for diffusivity and calculated conductivity at temperatures of 1200, 1300, 1400, 1500, 1600, 1650, and 1700 degrees Celsius, and ASTM E1269 for differential scanning calorimetry (DSC) specific heat capacity measured from 25 to 1650 degrees Celsius. The actual density of the simulant during testing shall be documented and reported as part of the deliverables.
Performance of the work shall take place at Firm's Testing Facility, with a final report delivery deadline no later than 8 weeks after procurement. The scope requires comprehensive thermal testing that characterizes the material's thermal behavior across a wide temperature range relevant to lunar surface conditions, with precise density specifications to ensure test validity and reproducibility.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements
a. Gather thermal properties of ICN-LHT-1G lunar regolith simulant at a relevant bulk sample density of 1.5 to 1.6 grams per cubic centimeter.
i. ASTM E1461 Diffusivity and calculated conductivity
1. Temperatures of 1200, 1300, 1400, 1500, 1600, 1650, and 1700 Degrees Celsius
ii. ASTM E1269 DSC specific heat capacity
1. Measured from 25 to 1650 degrees Celsius
2. Characteristics, Scope, and Specs
a. Provide thermal testing of ICN-LHT-1G lunar regolith simulant.
b. Testing will include
i. ASTM E1461 Diffusivity and calculated conductivity
1. Temperatures of 1200, 1300, 1400, 1500, 1600, 1650, and 1700
Degrees Celsius
ii. ASTM E1269 DSC specific heat capacity
1. Measured from 25 to 1650 degrees Celsius
iii. Simulant shall be to a density of 1.5-1.6 grams per cubic centimeter during testing. Density shall be reported.
3. Place of Performance Frim’s Testing Facility
4. Period of Performance Final report delivery no later than 8 weeks after procurement.
File details come from the government source that posted it. Updated .