This is a Statement of Work for a Foam Proportioning and Dispensary Unit. The required system must be a spray foam proportioner with drum-to-gun connectivity capable of supporting 110-gallon total capacity (55 gallons per component) with separate drums for Isocyanate and Polyol components. The unit must be capable of heating both isocyanate and polyol components and be compatible with internally heated hoses to deliver these materials via a spray gun. The system shall include a display unit showing temperature, pressure, and flow rate or ratio of components. The equipment must be portable and cannot be installed as a permanent or semi-permanent fixture.

The minimum requirements specify that the proportioning unit must control and maintain delivery hose temperature, provide adjustable setpoints for temperature, pressure ranges, and flow rates, and include data logging and recording capabilities for temperature, component pressure, and flow rate or ratio parameters. Additionally, the recorded data must be exportable in a usable format for further analysis or documentation purposes.

View the file

Other files

File Type Posted
SATPC0042306 Tab 10 4 Q-A.pdf PDF
SATPC0042306 TAB 10 1 RFQ Open Market.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work – Foam Proportioning and Dispensary Unit

Physical Components

Spray foam proportioner with drum-to-gun connectivity 110-Gal Capacity (55gal per component) Capable of supporting separate 55-gal drums of Isocyanate and Polyol Capable of heating isocyanate and polyol components Compatible with internally heated hoses that allow for Isocyanate and Polyol to be delivered for distribution via a spray gun Display unit that shows temperature, pressure, and flow rate (or ratio) of components Machine needs to be able to be moved, cannot be a permanent or semi-permanent fixture

Minimum Requirements

Can control/maintain temperature of delivery hose.

Can change/control setpoints for temperature, pressure ranges, and flow rates.

Can log/record data of various setpoints and parameters, including temperature, component pressure, flow rate (or ratio).

Recorded data needs to be able to be exported.