About this file

This document is an Item Description table detailing specifications for industrial pressure transducers for a NASA contract. The table lists four line items of GP:50 pressure transducers with varying specifications: 14 units of 240 C RT 3 A586 with a 0 to 3000 PSI absolute range, 6 units of 240 C RM 3 A586 with a 0 to 1000 PSI absolute range, 2 units of 240 D RM 3 A586 with a 0 to 1000 PSI absolute range and 0.10% FSO static accuracy, and 3 units of 240 C PV 3 A586 for atmospheric air service. All transducers share common features including 0 to 5 Vdc 4-wire non-isolated output, SAE J1926-4 process ports, D38999/27YA35PN electrical connectors, thermal compensation from -24°C to 61°C, shock and vibration resistance, and are designed to be small and lightweight. The document indicates this is a sole source requirement for NASA, specifically for the NASA Shared Services Center.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Description

Item ID Manufacturer Part Number Qty Description 1 GP:50 240 C RT 3 A586 14 Industrial Pressure Transducer

- 0 to 5 Vdc 4 wire Non Isolated Output

- 0 to 3000 PSI Absolute Range

- 0.3% FSO Static Accuracy

- SAE J1926-4 Female Process Port 7/16" - 20 Thread

- D38999 / 27YA35PN Electrical Connector

- Thermally compensated from -24 C to 61 C

- Built as small and light as possible

- Shock and Vibe Resistant Design

- Monel wetted Parts for service with 40% O2 Medium

2 GP:50 240 C RM 3 A586 6 Industrial Pressure Transducer

- 0 to 5 Vdc 4 wire Non Isolated Output

- 0 to 1000 PSI Absolute Range

- 0.3% FSO Static Accuracy

- SAE J1926-4 Female Process Port 7/16" - 20 Thread

- D38999 / 27YA35PN Electrical Connector

- Thermally compensated from -24 C to 61 C

- Built as small and light as possible

- Shock and Vibe Resistant Design

- Monel wetted Parts for service with 40% O2 Medium

3 GP:50 240 D RM 3 A586 2 Industrial Pressure Transducer

- 0 to 5 Vdc 4 wire Non Isolated Output

- 0 to 1000 PSI Absolute Range

- 0.10% FSO Static Accuracy

- SAE J1926-4 Female Process Port 7/16" - 20 Thread

- D38999 / 27YA35PN Electrical Connector

- Thermally compensated from -24 C to 61 C

- Built as small and light as possible

- Shock and Vibe Resistant Design

- Monel wetted Parts for service with 40% O2 Medium

4 GP:50 240 C PV 3 A586 3 Industrial Pressure Transducer

- 0 to 5 VDC 4-wire non-isolated output

- 0.3% FSO static accuracy

- SAE J1926-4 male process port 7/16 - 20 thread

- D38999/27YA35PN electrical connector

- Thermally compensated from -24 to 61°C

- Built as small and light as possible

- 17-4 PH SS wetted parts for service with atmospheric air

File details come from the government source that posted it. Updated .