SATPC0038498 Tab 04 4 SOW..pdf

PDF 764 KB Posted

Attached to
This procurement is for Shock Testing of GFE Reefing Line Cutters at Element US Space & Defense.
Solicitation number
80NSSC25904501Q
Issued by

About this file

This Statement of Work (SOW) details shock and vibration testing requirements for Government Furnished Equipment (GFE) Reefing Line Cutters (RLCs) for NASA. The contractor must perform comprehensive testing on two types of RLCs: 8-Second (P/N SEH26151650-313) and 16-Second (P/N SEH26151650-314) models, with 10 units of each type. Testing specifications include three shock tests in each orthogonal axis (positive and negative directions) and one vibration test per axis, with specific pulse and acceleration requirements. The testing must follow precise technical parameters, including half-sine shock pulse configuration, random vibration levels, and specific frequency and acceleration tolerances.

The SOW includes detailed administrative and safety requirements, mandating pre- and post-test visual inspections, NASA test witnessing, and comprehensive safety protocols due to the explosive components in the RLCs. The contractor must provide a complete test report within two weeks of test completion, documenting test setup, calibration information, and results. Shipping instructions require returning test articles to NASA/Lyndon B. Johnson Space Center using a provided FedEx account, with safety pins reinstalled. The testing is part of a sole-source requirement for Element US Space & Defense, with specific cautions about handling the explosive device components during testing.

View the file

Other files

File Type Posted
SATPC0038498 Tab 07 Capability Statement SAM.gov.pdf PDF
SATPC0038498 Tab 06 RDSS..pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/15/2025

Statement of Work Shock and Vibration Testing of Government Furnished

Equipment Reefing Line Cutters

1. SCOPE

Test Description The Contractor shall perform the following:

Shock Testing -

1. Perform checkout tests using mass simulators to develop the required shock pulse.

2. Perform three (3) shock tests in each orthogonal axis in both directions (positive and negative) on the following test articles:

a. Ten (10) 8-Second GFE RLCs (P/N SEH26151650-313)

b. Ten (10) 16-Second GFE RLCs (P/N SEH26151650-314)

3. Prove a test report.

Vibration Testing -

1. Perform checkout tests to develop the required vibration plots.

2. Perform one (1) vibration test in each orthogonal axis on the following test articles:

a. Ten (10) 8-Second GFE RLCs (P/N SEH26151650-313)

b. Ten (10) 16-Second GFE RLCs (P/N SEH26151650-314)

3. Provide a test report.

Test Article Description A representative Reefing Line Cutter (RLC) and its axis definition are shown in Figure 1. The X and Y axes are defined as the lateral axes, and the Z axis is defined as the longitudinal axis.

The 8-Second GFE RLC (P/N -313) measures approximately 5.78 inches in length and the 16-Second GFE RLC (P/N -314) measures approximately 6.13 inches in length. All RLCs’ delay cartridges contain an output mix that conforms to our Hi-Temp Propellant Specification in quantities of approximately 80 ± 2 mg. The mix will have a cutting capacity of 6500 lbf. The safety pin shall be removed prior to shock testing and reinstalled after completion of shock testing. The RLCs shall be installed in the provided fixture sent with the cutters.

Figure 1: Axis orientation of SEH26151650-313 RLC

Figure 2: Diagram of GFE RLC with markings

2. SHOCK TEST TECHNICAL REQUIREMENTS

Shock Requirements Each test article shall be subjected to three (3) shock tests in each orthogonal axis and meet the half-sine shock pulse requirements shown in Figure 2. Each test article shall be tested with the safety pin removed. (Note: Shock test level requirements are pending confirmation from designers.)

Figure 2: Half-Sine Shock Pulse Configuration & Tolerance Limits

Figure 3: Representation of RLCs in Vibration Fixture and Axis Orientation. (X Axis is at top left, Z axis is at top right, Y axis is at bottom.)

Data Acquisition All accelerometer data, including time history and PSD plots, as well as a digitized copy of the PSD data shall be provided. Checkout test data shall be provided for review prior to proceeding to test article vibration tests. In the event of an out-of-tolerance condition during test article vibration tests, NASA shall be notified and consulted before proceeding to subsequent vibration tests.

4. ADMINISTRSTIVE REQUIREMENTS

Pre- and Post-Test Visual Inspections A visual inspection of each test article shall be performed before and after shock testing.

Photographs shall be taken and included in the test report.

NASA Test Witnessing NASA personnel shall be allowed to be physically present to witness the test including set-up operations and test article installation into the shock test fixture.

Delivery Schedule and Turn-Around Time

Test article delivery to the Contractor is to be determined (TBD). The Contractor is requested to return the test articles and supply a test report to NASA within 2 weeks from the date of test completion.

Test Report The Contractor shall furnish a test report that will include test set-up photographs, calibration information, and test results as well as any other information necessary to describe the test operations performed and the results obtained. If hardware is damaged during test, photographs will be provided in addition to a written description.

5. SAFETY REQUIREMENTS

The Contractor shall comply with all Federal, State, and Local codes and standards applicable to work performed on this contract.

Each RLC contains a delay cartridge with the following explosive constituents:

• 80 ± 2 mg of output mix that conforms to our Hi-Temp Propellant Specification

The RLC is initiated via pulling of the lanyard, which requires 15-55 lbf. Do not pull on the lanyard, and exercise caution when handling the RLC with the safety pin removed.

Appropriate controls/safeguards shall be implemented to mitigate hazards associated with unintentional initiation of the RLC. Such hazards include high sound levels, high temperatures, shrapnel or blast wave over-pressurization, and sharp points or edges. In the event of unintentional initiation, the RLC is self-contained but may heat to high temperatures. Do not place fingers in the RLC aperture where the blade is located. Recommended hazard controls and example procedural steps can be provided upon request.

6. SHIPPING, PRESERVATION AND PACKAGING REQUIREMENTS

The Contractor shall repackage the test articles in the same packaging that they were shipped

in. The test articles shall be shipped with the safety pins installed. A NASA/JSC FedEx account number will be supplied for return shipping. The Contractor shall ship all deliverables to the following address unless otherwise directed by NASA: