About this file

This document is a Statement of Work (SOW) for a sole source contract to replace the zeolite molecular sieve in three (3) OG-500 oxygen generator systems at the NASA Glenn Research Center.

The key requirements include: 1) Providing 3,600 pounds of PSA02-XP 8 x 12 MOLSIV Adsorbents (zeolite), 2) Performing an on-site service visit to completely remove the existing sieve, refill the tanks with new sieve, and ensure proper function of the generators to obtain ~93% purity oxygen. The work must comply with OSHA regulations and the contractor must submit a Health and Safety Plan for approval. Service personnel must be knowledgeable and utilize appropriate personal protective equipment.

The related federal contract opportunity is a sole source procurement under FAR Part 13 for the zeolite molecular sieve replacement, to be awarded to NOVAIR USA CORP as the sole provider. NASA's Shared Services Center is the procuring agency, and performance will be located at the NASA Glenn Research Center. Interested parties may submit their capabilities by 7/25/2024 for the government's consideration of a competitive procurement.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

The NASA Glenn Research Center has three (3) OG-500 oxygen generator systems that require service to replace the zeolite molecular sieve.

The requirements for this service are as follows:

1) 3,600 pounds of PSA02-XP 8 x 12 MOLSIV Adsorbents (zeolite)

2) On-site service visit that includes:

i. complete removal of existing zeolite molecular sieve

ii. refilling of the tanks with new sieve

iii. ensuring proper function of generators to obtain ~93% purity oxygen after replacing sieve.

All work performed under this contract on-site at Glenn Research Center shall be in compliance with 29CFR1910 and/or 29CFR1926 (OSHA) and those policies set forth in the NASA Glenn Research Center's Safety and Occupational Health Program manuals. The Contractor shall submit a Health and Safety Plan (HASP) in accordance with the NASA Glenn Safety Manual. Work shall proceed only when approval by GRC SHeD is received. A template for the HASP is provided on the next page.

Service personnel should be knowledgeable and trained in appropriate health and safety procedures for working with oxygen generating equipment and utilize appropriate personal protective equipment

(PPE).

File details come from the government source that posted it. Updated .