This document is a Statement of Work (SOW) for the FY24 Raid Inc ARI-600 Series 25GbE ISCSI federal contract opportunity. The SOW outlines the government's requirement for 2 units of the Raid Inc ARI-600 Series 25GbE ISCSI, which includes 12-bay storage systems with dual 25GbE ISCSI controllers, 48GB of cache, and support for up to 120 HDDs. The contract also includes 24 12TB SAS HDDs, 4 SFP+ modules, and 8 3M LC-LC cables. The period of performance is 30 days after award. The procurement is a sole source requirement for the Raid Inc ARI-600 Series, to be delivered to the Goddard Space Flight Center in Greenbelt, MD. The contract includes 36 months of RAIDserv support services with next business day component replacement and 24/7 phone support.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SATPC0035792 Tab 07 Capability Statement SAM.gov.pdf | ||
| SATPC0035792 Tab 06 RDSS..pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
1. Objective/Requirements
Goddard Space Flight Center has a requirement for the Raid Inc ARI-600 Series 25GbE ISCSI, the specifics are listed below.
2. Characteristics, Scope, and Specs
QTY Description Part Number
2 2U - 12 Bay supports 2.5" SSD's & 3.5" HDD's Dual 25GbE
ISCSI Controllers - 4 Host Ports per Ctrl - 8 total 48GB
Cache per system - 24GB Per Controller Redundant controllers, fans, power supplies and ‘Hot Swappable’ drives. Drive Expansion Support for up to 120 HDD's (9)12-
Bay Disk Expansion Chassis Includes carriers, rail kit and cables. Features Include: Declustered RAID Technology, Thin Provisioning, Quick Rebuild, Degraded Disk
Detection, Automated Provisioning Tool, Centralized
Management Interface, Disk Background Scrub, Self-
Sufficient Drive Restoration (SSDR), Battery Free Cache
Backup and SED/FIPS encryption at rest (with purchase of supported drives). Optional features for an additional cost:
Snapshots, Asynchronous Replication, Automated Tiering, SSD Read Cache and Volume Copy
ARI-600 Series 25GbE ISCSI
24 ARI 600 Series 3.5”, 12TB, SAS 12Gb/s, 7.2K RPM, 512E ARI-600 Series 3.5" 12TB SAS
12Gb/ s – S
4 ARI Series - 25GigE SFP - 4PK ARI Series 25GigE SFP+ LC
Mod, 4PK
8 3M LC to LC Cable 3M LC - LC Cable
1 RAIDserv support services: 36 Months - Next business day component replacement, including firmware updates - 24 hour phone support (24x7x365) - Keep your hard drive policy
*RS-T2-36, HDD retention policy
3. Place of Performance
Goddard Space Flight Center
8800 Greenbelt Road, Greenbelt MD 2077
Building 32, Room N231
4. Period of Performance
30 days ARO