This document outlines requirements for a turnkey, temperature-controlled cleanroom enclosure for use by the National Aeronautics and Space Administration Shared Services Center. The enclosure must have an interior footprint of 9 by 9 feet to contain equipment up to 105 inches tall on a 3 by 3 foot granite table. It must control temperature within 0.1 degrees F given room fluctuations between 68 and 75 degrees F, and control relative humidity between 30-55% given room fluctuations between 25-70% RH. Cleanliness inside the enclosure must be within Class 1000 standards. Airflow must be minimized while providing sufficient makeup air to support two workers. The related federal contract opportunity, solicitation number 80NSSC23841999Q, seeks proposals for a temperature-controlled cleanroom enclosure to meet the requirements specified in the document.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Introduction

We are seeking a turnkey, high-precision, controlled-environment cleanroom enclosure. This enclosure will contain equipment required to align and bond X-ray mirror shells to flight mounting structures.

Enclosure requirements:

• Size - The tent interior footprint must be 9 x 9 feet and contain equipment that is 105 inches tall on a 3 x 3 foot granite table.

• Temperature – Given a room where the temperature fluctuates 68 and 75 degrees F, the enclosure will be able to control temperature to within 0.1 degree F.

• Relative humidity – Given a room where the relative humidity may fluctuate between 25 and

70% RH, the enclosure will be able to control the relative humidity between 30 and 55% RH.

• Cleanliness – Cleanliness inside the enclosure will be controlled to within Class 1000.

• Airflow – Airflow through the enclosure will be minimized.

• Reflow – The enclosure will either have clear walls or interior lighting sufficient for work surfaces. Sufficient makeup air will be used in the system airflow to support two workers inside the tent.

• Atmospheric Pressure - No requirement.