Q&A for RFQ 80NSSC20740536Q

1. What is the voltage for the L-854 as well as the Amp load?

The input voltage is 24V as specified in the RFQ. Amp load is unknown.

2. For the Solar L-849 I need to know the following things:

a. Does the L-849(REIL) need to be certified?

No, but should function within the standard certifiable specifications.

b. Where is this going to be installed so we can properly size the battery sled

This is for a mobile facility. There is no permanent location, and we are not soliciting for a “battery sled”

c. What are the operations? Should the REILS be on all night? (3-4) 15min operations per night?

REILS will flash continuously for a period of 6 hours per day.

d. Shall the system be energized via radio or photocell?

System shall be radio controlled.

e. Any other operational characteristics specific to this installation?

Field-selectable 118-137 MHz for the L854 radio.