Chiller Order:

Purpose: Provide cooling water for an IVI model 14 vacuum furnace, for sustained operation of furnace at high temperature.

Specifications:

- Stand-alone unit

- Provide minimum cooling capacity of:

o 80,000 BTUs/hr o Alternate units: 24,000 watts or 7 tons

- Operates on water or water-coolant solution

- Coolant flow pumping of at least 10 gpm controllable down to at least 18 psi to furnace input @ approximately 60 - 70 degrees F nominal.

- Coolant is end-user replenishable.

- 1-1/4” inlet/outlet NPT connections

- 208/460 V input power capable

- Limit monitoring that can be integrated into furnace control system.