Tab_19-_Specifications.pdf
PDF 64 KB Posted
- Solicitation number
- 80GRC019Q0013
About this file
Technical Specifications for RFQ 80GRC019Q0013
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_2_Question_and_Answer.pdf | ||
| Amendment_1_Questions_and_Answers.pdf | ||
| Tab_19-_Combined_Synopsis_Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
80GRC019Q0013
Attachment 2: Specifications
DC power supply to provide 1.5MW of power at 700VDC. Unit may come in scalable sections that combine to create a 1.5MW system.
All listed values shall be considered minimum values.
Delivery time shall be 8 weeks upon receiving purchase order.
Input Specifications:
3Φ AC Input Voltage:
3Φ, 3-wire + ground 480 Vac (operating range 432 to 528 Vac)
Input Frequency:
50 to 60 Hz
Power Factor:
> 0.96 at maximum power, AC Input Isolation:
±2500 Vac, maximum input voltage to ground
Output Specifications:
Voltage ramping:
Programming shall allow the voltage to be linearly ramped up to maximum voltage over 15 seconds or less as programmed or controlled by user.
Voltage Ripple:
Less than 300mV at rated voltage
Line Regulation :
Voltage mode: ± 0.004% of full scale Current mode: ± 0.02% of full scale
Load Regulation :
Voltage mode: ± 0.01% of full scale Current mode: ± 0.04% of full scale
Load Transient Response :
2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change
Stability:
± 0.10% for 8 hrs. after 30 min. warm-up
Efficiency:
86% to 88% Model specific. Refer to chart of available models.
Maximum Slew Rate:
100 ms for an output voltage change from 0 to 63% 100 ms for an output current change from 0 to 63%
Maximum Slew Rate:
4 ms for an output voltage change from 0 to 63% 8 ms for an output current change from 0 to 63%
Bandwidth:
Standard Models 3 Hz with remote analog voltage programming 2 Hz with remote analog current programming
DC Output Isolation:
±4000 Vdc, maximum output voltage to ground
Control Specifications
Must include ability for the following I/O points:
- Logic output for AC input power on
- Logic output for DC output on
- Logic input for an external E-stop
Voltage Programming Accuracy:
± 0.075% of max rated voltage
Over Voltage Trip Programming Accuracy:
± 0.075% of max rated voltage
Current Programming Accuracy:
± 0.075% of max rated current
Voltage Readback Accuracy:
± 0.2% of max rated voltage
Current Readback Accuracy:
± 0.2% of max rated current
Load Regulation :
Voltage mode: ± 0.01% of full scale Current mode: ± 0.04% of full scale
Computer Command Protocol:
Standard Commands for Programmable Instruments (SCPI)
External User I/O Port:
37-pin D-sub DC-37, female Referenced to Earth ground; isolated from power supply output Analog Programming and Monitoring Levels:
0-10 Vdc
Analog Output Impedances:
Voltage output monitoring: 100 Ω Current output monitoring: 100 Ω +10V reference: 1 Ω
Digital Programming and Monitoring Limits:
Input: 0 to 5 Vdc, 10 kΩ input impedance Output: 0 to 5 Vdc, 5 mA drive capacity
Remote Sense Limits (Wired):
3% maximum voltage drop from output to load
Environmental Specifications
Ambient Operating Temperature:
0°C to 50°C
Storage Temperature:
-25°C to +85°C
Humidity:
Relative humidity up to 95% non-condensing
Temperature Coefficient:
0.04%/°C of maximum output voltage 0.06%/°C of maximum output current
Air Flow:
Rear air inlet, top exhaust
Regulatory Compliance:
EMC:
Complies with European EMC Directive for test and measurement products
Safety:
Complies with EN61010-1
CE Mark:
Yes
RoHS Compliant:
Yes
File details come from the government source that posted it.