This is a Limited-Sources Justification (LSJ) for a high-resolution mass spectrometer (HRMS) procurement by NASA Ames Research Center, documented as JA-FY27-J02 and conducted under the General Services Administration (GSA) Multiple Awards Schedule (MAS) Program.

NASA seeks to procure an integrated high-resolution mass spectrometry system capable of analyzing both soluble and insoluble sample fractions through electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) on a single mass analyzer. The system will be installed in NASA Ames' Optical Constants and Chemical Composition Facility (OC3F) to characterize elemental and molecular composition of laboratory-generated refractory samples simulating cosmic grains and planetary aerosols. The award will be made to Thermo Electron North America, LLC under GSA Federal Supply Schedule (FSS) Contract No. 47QSWA21D0055, with a total estimated price of $379,130.18 and an eight-week delivery lead time. The justification cites FAR 8.401(b)/GSAM 538.7104-3(b)(ii) as the authority, establishing that only one source is capable of providing the required products and services at the level of quality needed because the solution is unique and highly specialized. NASA's market research, including a Request for Information (RFI) posted through GSA eBuy, evaluated commercially available systems from Thermo Fisher Scientific, Bruker, and Shimadzu. The Thermo Fisher Scientific Orbitrap Exploris 240—configured with OptaMax NG interface, H-ESI II probe, MALDI source, and Xcalibur software—is the only identified configuration meeting all minimum requirements, including mass range (m/z 40–6,000), resolving power (240,000 FWHM at m/z 200), mass accuracy (5 ppm or better), dual ESI/MALDI operation, full-scan and tandem MS/MS capabilities, and physical installation constraints. Alternative systems either failed to meet technical specifications (Shimadzu MALDI-8030 EasyCare) or lacked adequate physical space for required operating clearances (Bruker scimaX), necessitating facility modifications or acquisition of additional instruments.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rev.:4/2026

NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

AMES RESEARCH CENTER (ARC)

LIMITED-SOURCES JUSTIFICATION

FOR HIGH-RESOLUTION MASS SPECTROMETER

This is a Limited-Sources Justification (LSJ) prepared by the National Aeronautics and Space Administration (NASA) Ames Research Center, Moffett Field, CA. This LSJ is recorded in the ARC JOFOC/JEFO/LSJ Log as JA-FY27-J02.

This acquisition will be conducted under the Multiple Awards Schedule (MAS) Program (Title 41 U.S.C. 152(3)). This action is for a new delivery order for a high-resolution mass spectrometer (HRMS), including the mass analyzer, interchangeable electrospray and matrix-assisted laser desorption/ionization sources, vacuum equipment, data system, control and analysis software, installation, acceptance testing, application training, warranty, and technical support. The system will be installed as a stand-alone instrument in NASA Ames Research Center’s Optical Constants and Chemical Composition Facility (OC3F). OC3F characterizes the physical and chemical properties of laboratory analogs of astrophysical and planetary materials. The HRMS will determine the elemental and molecular composition (CxHyNzOw) of organic refractory samples that simulate cosmic grains and planetary or exoplanetary aerosols. The samples are produced through gas-phase chemistry using the COsmic SImulation Chamber (COSmIC) and through ice chemistry using the Ices, Ice Irradiation and Organics Laboratory for AstroBiology (I3OLAB) and Matrix Isolation/Optical Constants of Ices (MIOCI) facilities. NASA will use the measurements to correlate molecular composition with measured optical properties and complete experimental milestones under NASA-funded research projects.

The required HRMS must analyze soluble and insoluble fractions of laboratory-generated refractory samples using electrospray and matrix-assisted laser desorption/ionization (MALDI) ionization on a single mass analyzer. The system must provide the mass range, resolving power, mass accuracy, polarity operation, full-scan and tandem mass spectrometry (MS/MS) capabilities, dynamic range, utility compatibility, and physical configuration necessary for NASA’s intended analytical workflow.

It is anticipated that award will be made to Thermo Electron North America, LLC under General Services Administration (GSA) Federal Supply Schedule (FSS) Contract No.

47QSWA21D0055.

The total estimated price of the proposed order is $379,130.18, and the estimated delivery lead time is eight weeks after receipt of order.

Authority Cited: The statutory exception supporting the placement of this order that exceeds the SAT on a sole source basis is:

FAR 8.401(b)/GSAM 538.7104-3(b)(i). The need is of such unusual urgency that following normal procedures would result in unacceptable delays in fulfilling the need.

FAR 8.401(b)/GSAM 538-7104-3(b)(ii). Only one source is capable of providing the products, services, or solution required at the level of quality required because the products, services, or solutions are unique or highly specialized.

FAR 8.401(b)/GSAM 538.7104-3(b)(iii). The order should be issued on a sole source basis in the interest of economy and efficiency because it is a logical follow-on to an FSS order already issued on a competitive basis.

FAR 8.401(b)/GSAM 538.7104-3(b)(iv). It is necessary to place the order with a particular FSS contractor to satisfy a minimum guarantee established in the FSS BPA.

FAR 8.401(b)/GSAM 538.7104-3(b)(v). A law expressly authorizes or requires that the purchase be made from a specified source. Identified law is:____________________________

FAR 8.401(b)/GSAM 538.7104-4(b)(1), Items peculiar to one manufacturer. The particular brand name, product, or feature is essential to the NASA’s requirements, and market research indicates other companies’ similar products, or products lacking the particular feature, do not meet, or cannot be modified to meet, the need.

Rationale:

In accordance with FAR 8.104(b)/GSAM 538.7104-3(b)(2), justifications must include sufficient detail and supporting rationale to support the exception used. The detail and supporting rationale to support the exception used is provide below:

FAR 8.401(b)/GSAM 538-7104-3(b)(ii), only one capable source/unique or highly specialized:

Unique Qualifications: NASA requires a single, integrated high-resolution mass spectrometry system capable of analyzing both soluble and insoluble sample fractions through a consistent analytical workflow. The limited-source basis does not rest on any one specification considered in isolation. Rather, it is based on the instrument's ability to satisfy all minimum performance, ionization, installation, interoperability, and support requirements as an integrated system.

NASA conducted market research of commercially available high-resolution mass spectrometry systems capable of meeting the minimum requirements for mass range, resolving power, mass accuracy, dual Electrospray Ionization (ESI)/MALDI operation, installation constraints, and manufacturer-supported integration. Market research included review of available Federal Supply Schedule offerings, manufacturer literature, publicly available technical specifications, and a Request for Information (RFI) posted through GSA eBuy. The eBuy RFI provided Federal Supply Schedule contractors an opportunity to identify products capable of meeting NASA's minimum requirements and installation constraints. No responses were received identifying an alternative commercially available solution capable of satisfying all stated requirements.

Based on NASA's market research, the Thermo Fisher Scientific Orbitrap Exploris 240, configured with the OptaMax NG interface, H-ESI II probe, MALDI source, and Xcalibur software, is the only identified and evaluated configuration that satisfies the complete requirement. The required configuration:

Covers the required mass range of m/z 40 through 6,000;

Provides resolving power up to 240,000 full width at half maximum (FWHM) at m/z 200;

Meets or exceeds NASA's required mass accuracy;

Supports high-resolution full-scan and tandem mass spectrometry acquisition;

Operates in both positive- and negative-ion electrospray modes with rapid polarity switching;

Supports electrospray ionization and matrix-assisted laser desorption/ionization analyses using the same mass analyzer;

Operates within the utilities available at the installation site;

Fits within the documented installation footprint, including required operating and service clearances; and

Is available as an integrated, installed, tested, trained, warranted, and manufacturer-supported system.

The combined electrospray and MALDI capability on a common high-resolution mass analyzer is essential to NASA's analytical need. It enables both soluble and insoluble sample fractions to be evaluated using a consistent calibration framework, detector response, acquisition platform, and data-processing environment. Using separate analyzers would introduce instrument-to-instrument variability, require separate calibration and qualification procedures, complicate comparison of analytical results, and create a materially different workflow. It would also increase laboratory space, utility, training, maintenance, software, validation, and lifecycle-support requirements.

NASA evaluated commercially available systems identified through market research, including offerings from Thermo Fisher Scientific, Bruker, and Shimadzu. The Shimadzu MALDI-8030 EasyCare does not satisfy NASA's minimum technical requirements because its published resolving power of greater than 5,000 FWHM at m/z 2,465 is below NASA's minimum requirement of 15,000 FWHM, and its published mass accuracy of less than 20 ppm with internal calibration, or less than 150 ppm with external calibration, does not meet NASA's requirement of 5 ppm or better. In addition, the evaluated Shimadzu configuration does not provide electrospray and MALDI ionization, together with high-resolution full-scan and MS/MS acquisition, on the same mass analyzer.

The Bruker scimaX offers high mass performance and supports ESI and MALDI capabilities.

However, the evaluated configuration does not fit within NASA's documented installation area when the manufacturer's required operating and service clearances are included. Acquiring this configuration would therefore require facility modification or another material change to NASA's stated minimum requirements.

As a result, the evaluated alternatives would either fail to satisfy one or more minimum technical or installation requirements or require NASA to acquire an additional instrument, modify the facility, or adopt a materially different analytical workflow. Based on the market research performed, including the results of the GSA eBuy RFI, NASA did not identify any alternative commercially available system capable of meeting all minimum requirements. The Thermo Fisher Scientific configuration is the only identified and evaluated solution that satisfies every minimum requirement without such changes.

Exclusivity: The manufacturer-specific features are essential to NASA's requirement because the required capability depends on the integrated operation of the Orbitrap Exploris 240 platform, OptaMax NG interface, compatible H-ESI II and MALDI ion sources, and Xcalibur software.

These components must operate together as a fully integrated and manufacturer-supported system. A product lacking this integrated configuration would not provide the required analytical capability, common mass analyzer, validated interoperability, or unified acquisition and data-processing workflow.

Market research did not identify a competing product that could satisfy the complete requirement without failing a minimum performance or installation requirement, requiring additional instrumentation, requiring facility modifications, or introducing a materially different workflow.

Additionally, NASA posted an RFI through GSA eBuy seeking information from Federal Supply Schedule contractors regarding their ability to provide a solution meeting the stated requirements. No responses were received identifying an alternative product, configuration, or source capable of satisfying the complete requirement.

The anticipated order will be placed with Thermo Electron North America LLC, the Federal Supply Schedule contractor offering the required Thermo Fisher Scientific Orbitrap Exploris 240 configuration. The schedule offering includes the required manufacturer-authorized configuration, installation, acceptance testing, application training, warranty coverage, and ongoing technical support.

The acquisition file includes documentation of the market research, technical evaluation, and GSA eBuy RFI results. Based on this research, NASA determined that the required configuration and integrated capabilities are peculiar to Thermo Fisher Scientific and that Thermo Electron North America LLC, as the applicable Federal Supply Schedule contractor, is the only identified FSS source capable of providing the complete manufacturer-authorized configuration and associated support necessary to satisfy NASA's minimum requirements.

HIGH-RESOLUTION MASS SPECTROMETER

LIMITED SOURCES JUSTIFICATION

SIGNATURE PAGE

I certify that the supporting data presented in this justification are accurate and complete.

Ella Sciamma-O’Brien Technical Representative

Contracting Officer: I hereby certify that this justification is accurate and complete to the best of my knowledge and belief. In addition, I hereby determine that the anticipated price(s)/pricing of the order will be fair and reasonable.

Rosalinda De Leon Contracting Officer