8. 21-1501 - AF 66.pdf
PDF 134 KB Posted
- Attached to
- Repair Fire Suppression System
- Solicitation number
- FA500021Q0062
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AF FORM 66, OCT 99 Previous Edition Will Be Used
LI
NE
N
UM
BE
R Note: 3 copies required per submittal.
Government will retain all submittals.
Provide an electronic copy for each submittal.
C
ER
TI
F.
O F
C O
M
PL
IA
N
C E
SH
O
P D
R
AW
IN
G
S
C O
LO
R
S
EL
EC
TI
O N
M
AN
U
FA
TU
R
U R
'S R
EC
O
M M
EN
D
AT
IO
N
C
AT
AL
O
G D
AT
A
O &M
R
EC
O M
M
EN
D
AT
IO
N
S
C
AL
C U
LA
TI
O N
S
W
AR
R
AN
TY
D R
AW
IN
G S
R
EP
O R
T
TE
ST
R
ES
U
LT
S
R
EQ
U
IR
ED
S
U
BM
IS
SI
O N
D
AT
E
D
AT
E
TO
C O
N
TR
AC
TI
N G
D
AT
E
TO
C
IV
IL
E
N G
IN
EE
R
IN
G
R
ET
U R
N S
U
SP
EN
SE
D
AT
E
SU
BM
IT
TA
L N
U M
BE
R
S
AP
PR
O
VE
D
D
IS
AP
PR
O
VE
D
C O
N
TR
AC
TO
R S
U
BM
IT
TA
L
FI
N
AL
A
PP
R
O
VA
L
NOTES
GENERAL
1 Project Specific Form 66 X NTP + 30 2 Construction Schedule X NTP + 30 3 Contractor's Health, Safety, and Environment Plan X NTP + 30 4 Contractor's QA/QC Plan X NTP + 30 5 Environmental Precon Checklist X NTP + 10
6 HAZMAT Approval, General Specs 01500 X
NLT 14 working days prior to material being brought onto installation
7 HAZMAT Usage Report, General Specs 01500 X NLT 7 Working Days After Final
Acceptance
8 Copy of Engineering License(s) of person or consultancy responsible for design X Design
DESIGN
All submissions to be provided in hard copy and electronically (The electronic submission will include the *.CTB file and any other supporting file required to print the drawing correctly) 65% and 100% Design Drawings to include:
X NTP + 90 (100%)
10 Floor Plan, Elevations, Sections, Schedules, and Details X NTP + 90
11 Fire Supression Layout X NTP + 90
DEMOLITION
12 Demolition Plan X X NTP+30
MECHANICAL/FIRE PROTECTION
13 Piping X X NTP + 90 14 Equipment/'Devices X X NTP + 90
CLOSEOUT
15 O&M maint. data and maint manuals & Manufacturer's Warranty for All Equipment Installed X X Install + 7
16 Equipment Test Results/Balancing Report X X Prior to Project Closeout
17 As Builts (electronic in AutoCAD and hard copies on Mylar) X Final + 7
SOLICITATION /CONTRACT NUMBERPROJECT NAME
Repair Fire Suppression (FSD 1)
B8088
SCHEDULE OF MATERIAL SUBMITTALS
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR
PROJECT NUMBER
FXSB 21-1501
Submittal 1
File details come from the government source that posted it. Updated .