7K Refueler Specifications.pdf

PDF 60 KB Posted

Attached to
7, 000 Gallon Aviation Fuel Tender/Refueler Truck
Solicitation number
80AFRC21Q0009
Issued by

About this file

This solicitation requests offers for one 7,000 gallon aviation fuel tender/refueler truck to support ongoing flight operations at NASA Armstrong Flight Research Center. The vehicle must meet all specifications detailed in Attachment 1, including a minimum 300 GPM pump and filtration system, 7,000 gallon aluminum tank, overhead hose reel, and safety and control features. Offers are due no later than July 30, 2021 and delivery within 30 days of order is required to the specified NASA facility in Edwards, California. This is a total small business set-aside for NAICS code 336120. Responsible sources may submit offers which will be considered by the agency. Questions regarding this solicitation must be submitted in writing by July 22 with no commitment to pay costs incurred in offer preparation or proposed supplies/services.

View the file

Other files

File Type Posted
Terms and Conditions.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7K Jet Refueler COMMENTS

Condition: New

Requisite Standards: Must Meet all ATA Standards

Engine:

1) Minimum Tier IV Final engine, Diesel

Transmission:

1) Automatic

Tank:

1) 7000 Gallon

2) Fully baffled, single compartment

3) 20” Manhole

4) Overturn Protection

5) Emergency pressure/vacuum vents

Pumping System:

1) 300 GPM minimum pump

2) 300 GPM Rated Filter/Seperators

3) 300 GPM Rated Flow Meter

4) Single Overwing hose reel w/ rewind and shut off valve upstream

5) 50’ minimum aviation grade fuling hose w/ nozzle (overwing)

6) Aluminum piping rated for 150 PSI working pressure

7) Filtration Differential Gauge

8) Filtration air eliminator, water defense, relief valve and drain valve

9) Recirculation capabability

10) De‐Fuel Capability, that works with high level shutoff

11) Jet level sensor, with high level shutoff and precheck capability

Controls:

1) Electrically operated Deadman as Primary pressure control

Cab:

1) Air Conditioning Desirable, not req'd

Miscellaneous:

1) Minimum Qty 1) Fire Extinguisher w/ mount

2) Static Grounding Reel 50' minimum

3) Flashing Beacon

4) Emergency Shutdown

5) Back up Alarm

Meet Specifications Listed

6) Operators, Maintance, and Parts Manuals

7) Back up Camera Desirable, not req'd

8) Chock Block Holder Desirable, not req'd

9) Storage Box for Spillkit Min Dimensions: 24" x 24" x 24" Desirable, not req'd

Delivery:

1) FOB to Edwards, CA

2) ETA ARO 30 Days