7a Electronic Drawings.pdf
PDF 8 MB Posted
- Attached to
- Y1DA--FY23: NRM-Tier 2 (PROJ: 673-14-104) BB Renovate and Replace Transportation Equipment Building 1
- Solicitation number
- 36C24823R0186
About this file
This is a pre-solicitation notice for a set-aside contract to replace elevators at the James A. Haley VA Hospital in Tampa, Florida. The project involves replacing ten elevators in Building 1 and is set aside for Service-Disabled Veteran-Owned Small Businesses. The solicitation number is 36C24823R0186 and will be posted on SAM.gov on or around June 28, 2023. Interested SDVOSBs should contact the named contracting staff. Apparent awardees must be certified as SDVOSBs by the SBA VetCert program by time of award. The work includes replacing aging elevator equipment that is obsolete and inefficient with new systems per provided drawings and specifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 7 Electronic Specifications.pdf | ||
| 5 SOW 673-14-104.pdf | ||
| 36C24823R0186.docx | DOCX document | |
| TAMPA ELEVATOR MODERNIZATION - OHC Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
XX
X
1/A101
X
A101
XX
TOILET ACCESSORY TAGX SIGNAGE TAG
A101
SIM
X
James A. Haley VAMC
B R
U C
E B
D
O W
N S
B L
V D
E. FOWLER AVE.
L A
K E
B E
H N
K E
RICHARD SILVER WY
E. 131ST AVE
582 582 582
582E. FOWLER AVE.
579579 579
I 275
I 275
I 75
I 75
41 41
41 41
E. BEARSS AVE.
E. FLETCHER AVE. E. FLETCHER AVE.
E. BOUGAINVILLEA AVE.
N
N
D S
T
L
IV
IN
G
S T
O N
A V
E
N
T
H S
T
M C
K
IN
L E
Y D
R
TAMPA PALMS BLVD.
H
IL
L S
B O
R O
U G
H R
IV
E
R
H
IL
L S
B O
R O
U G
H R
IV
E
R
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Department of Veterans Affairs Medical Center
ABOVE GROUP INC.
MECHANICAL, ELECTRICAL, PLUMBING, TECHNOLOGY
305 EAST DRIVE, SUITE H
MELBOURNE, FL. 32904
321.345.9026 P
ARCHITECTURE PLANNING INTERIOR DESIGN
524 FERNWOOD AVENUE
ALTAMONTE SPRINGS, FLORIDA 32701
407.830.6522 P
RDC / JOHN POE ARCHITECTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
LERCH BATES
ELEVATOR CONSULTANT
9780 S. MERIDIAN BLVD, SUITE 450
ENGLEWOOD, CO. 80112
877.544.4171 P
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:2
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
COVER SHEET
G001
ACKR
673-14-104
TAMPA FLORIDA
B1
JAMES A. HALEY RENO & REPLACE
ELEVATORS
13000 Bruce B Downs Blvd Tampa, FL 33612 PROJECT #: 673-14-104
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
G001 COVER SHEET
G100 CODE DATA
AB-1 GENERAL NOTES - ASBESTOS
AB-2 FLOORING & DOORS
AB-3 FLOORING & DOORS
L-1 GENERAL NOTES - LEAD
L-2 LEAD DRAWING
A01 ELEVATORS 1-3
A04 ELEVATORS 4-5
A06 ELEVATOR 6
A09 ELEVATOR 9
A10 ELEVATORS 10-11
A18 ELEVATOR 18
A401 INTERIOR ELEVATIONS
VT01 GENERAL ELEVATOR INFORMATION
VT02 PLANS AND HOISTWAY SECTION - ELEVATORS 1-3
VT03 PLANS AND HOISTWAY SECTION - ELEVATORS 4-5
VT04 PLANS AND HOISTWAY SECTION - ELEVATOR 6
VT05 PLANS AND HOISTWAY SECTION - ELEVATOR 9
VT06 PLANS AND HOISTWAY SECTION - ELEVATORS 10-11
VT07 PLANS AND HOISTWAY SECTION - ELEVATOR 18
FP001 FIRE PROTECTION LEGENDS, SYMBOLS, & NOTES
FP01 ELEVATORS 1-5 - FIRE PROTECTION - NEW WORK
FP06 ELEVATORS 6,9,10-11,18 FIRE PROTECTION - NEW WORK
FP501 FIRE PROTECTION DETAILS
P-001 PLUMBING LEGENDS, SYMBOLS, & NOTES
PS01 ELEVATORS 1-5 - PLUMBING GRAVITY - NEW WORK
PS06 ELEVATOR 6 - PLUMBING GRAVITY - NEW WORK
PS09 ELEVATOR 9 - PLUMBING GRAVITY - NEW WORK
PS10 ELEVATORS 10-11 - PLUMBING GRAVITY - NEW WORK
PS18 ELEVATOR 18 - PLUMBING GRAVITY - NEW WORK
P-501 PLUMBING DETAILS
P-801 PLUMBING SCHEDULES
M-001 MECHANICAL LEGENDS AND SYMBOLS
M01 ELEVATORS 1-5 - MECHANICAL - DEMO AND NEW WORK
M06 ELEVATOR 6 - MECHANICAL - DEMO AND NEW WORK
M09 ELEVATOR 9 - MECHANICAL - DEMO AND NEW WORK
M10 ELEVATORS 10-11 - MECHANICAL - DEMO AND NEW WORK
M18 ELEVATOR 18 - MECHANICAL - DEMO AND NEW WORK
M-501 MECHANICAL DETAILS
M-801 MECHANICAL SCHEDULES
E-001 ELECTRICAL LEGENDS & SYMBOLS
E-002 ELECTRICAL GENERAL NOTES
E101 OVERALL BASEMENT PLAN
E102 OVERALL GROUND FLOOR PLAN
E103 OVERALL 3RD FLOOR PLAN
E104 OVERALL PENTHOUSE PLAN
E01 ELEVATORS 1-3 - ELECTRICAL - DEMO AND NEW WORK
E04 ELEVATORS 4-5 - ELECTRICAL - DEMO AND NEW WORK
E06 ELEVATOR 6 - ELECTRICAL - DEMO AND NEW WORK
E09 ELEVATOR 9 - ELECTRICAL - DEMO AND NEW WORK
E10 ELEVATORS 10-11 - ELECTRICAL - DEMO AND NEW WORK
E18 ELEVATOR 18 - ELECTRICAL - DEMO AND NEW WORK
E-601 ELECATRICAL DIAGRAMS & SCHEDULES
E-801 ELECTRICAL SCHEDULES
E-802 ELECTRICAL SCHEDULES
GENERAL CONSTRUCTION NOTES
7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO
BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE
SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT
THROUGH FINISHED OPENINGS.
8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,
HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS
AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT
DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL
WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS
SPECIFICALLY NOTED OTHERWISE. IF NO FINISH IS INDICATED AT A
PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS
INDICATED AT SIMILAR CONDITIONS.
10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL
SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE
THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE
NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR
SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.
11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED
WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF
THE WALL.
12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE SUBJECT TO
AN INDEPENDENT REVIEW BY A CERTIFIED FIRE PROTECTION ENGINEER
RETAINED BY THE OWNER. THE FIRE PROTECTION CONTRACTOR IS
RESPONSIBLE FOR MAKING ANY REQUIRED CHANGES TO THE DESIGN AS
IDENTIFIED BY THE OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY
FOR COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.
* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).
1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,
INTERNATIONAL BUILDING CODE, AND OTHER CODES AS IDENTIFIED IN VHA
PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE
ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,
TECHNICAL INFORMATION LIBRRARY WEBSITE.
2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND
DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13
WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS
TECHNICAL INFORMATION LIBRARY WEBSITE.
3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT
EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH
ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT
ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.
5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF
NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO
REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
SURFACES TO REMAIN.
6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW
MATERIALS.
DRAWING INDEX
N Scale: 1" = 300'-0"
Vicinity Map
Revisions Date
D
C
ROLL-UP
DOOR
ROLL-UP
DOOR
ROLL UP
DOOR
PASS-THRU
COPIER
0-HR Smoke Partition - NFPA 101-8.4
1-HR Smoke Barrier - NFPA 101-8.5
1-HR Fire Barrier - NFPA 101-8.3
2-HR Fire Barrier - NFPA 101-8.3
Means of Egress
Existing Wall to Remain
New Wall
CODE LEGEND
No color scheme assigned to viewAREA OF WORK
ELEVATOR 9
ELEVATOR 6
ELEVATOR 18
ELEVATOR 11
ELEVATOR 10 ELEVATOR 4
ELEVATOR 5
ELEVATOR 1
ELEVATOR 2
ELEVATOR 3
ZONE 1-G-7 ZONE 1-G-6 ZONE 1-G-5
ZONE 1-G-7
ZONE 1-G-11
ZONE 1-G-11
ZONE 1-G-7
ZONE 1-G-6
ZONE 1-G-5
ZONE 1-G-9
ZONE 1-G-8 SOUTH
ZONE 1-G-8 WEST
MRI ZONE
ZONE 1-G-1
ZONE 1-G-2
ZONE 1-G-3
ZONE 1-G-10
ZONE 1-G-4
LOADING
DOCK
ZONE 1-G-5 ZONE 1-G-4 ZONE 1-G-4
ZONE 1-G-11
ZONE 1-G-8 SOUTH
ZONE 1-G-8 SOUTH
ZONE 1-G-8 WEST
ZONE 1-G-8 WEST
MRI ZONE
MRI ZONE
ZONE 1-G-1
ZONE 1-G-1
ZONE 1-G-3 ZONE 1-G-10
ZONE 1-G-10
LOADING DOCK
Chapter 9 - Building Service and Fire Protection Equipment
9.4.1 - An elevator, other than an elevator in accordance with 7.2.13, shall not be considered a component in a required means of egress but shall be permitted as a component in an accessible means of egress.
9.4.2.1 - Except as modified herein, existing elevators, escalators, dumbwaiters, and moving walks shall be in accordance with the requirements of ASME A17.1/CSA B44
9.4.3.1 - All new elevators shall conform to the fire fighters’ emergency operations requirements of ASME
A17.1/CSA B44
9.4.5 – Elevator Machine Rooms: Elevator machine rooms that contain solid-state equipment for elevators, other than existing elevators, having a travel distance exceeding 50 ft above the level of exit discharge, or exceeding 50 ft below the level of exit discharge, shall be provided with independent ventilation or air-conditioning systems to maintain temperature during fire fighters’ emergency operations for elevator operation. The operating temperature shall be established by the elevator equipment manufacturer’s specifications. When standby power is connected to the elevator, the machine room ventilation or air-conditioning shall be connected to standby power.
9.6.1.3 – Fire Alarm System req’d for life safety shall be per NFPA 70 and 72.
9.6.3.1 – Occupant notification shall be provided per 9.6.3, 18.3.4.3.1.
9.6.3.4 – Where permitted by Chapters 11 thru 43, a positive alarm sequence shall be permitted per NFPA 72
(See 18.3.4.3).
9.6.4.1 – Emergency Forces notification req’d per 9.6.4 and 18.3.4.3.2.1.
9.6.5.1 – Emergency Control functions shall be installed per NFPA 72 as req’d per 9.6.5 and 18.3.4.4.
9.6.7.1 – Alarm annunciation is required per 9.6.7 and 18.3.4.3.3.
9.7.1.1 – Supervised automatic sprinkler system as req’d by 9.7.1 and 18.3.5.1 and shall comply with
NFPA 13.
Chapter 10 Interior Finish, Content and Furnishings
10.2.3 – Interior Wall or Ceiling Finish – shall be classified for fire performance and smoke development per
10.2.3.1 or 10.2.3.3 except as indicated in 10.2.4.
10.2.3.1 - Interior wall and ceiling finish materials shall be classified in accordance with NFPA 286 and comply with 10.2.3.2.
10.2.3.3 – Wall and Ceiling – Classifications characteristics:
(1) Class A: Flame spread: 0-25; Smoke dev.: 0-450.
(2) Class B: Flame spread: 26-75; Smoke dev.: 0-450.
(3) Class C: Flame spread: 76-200; Smoke dev.: 0-450.
(4) Existing interior finish exempt from smoke dev. criteria.
10.2.7.2 – Floor finish other than carpet: Min. Rad flux: .1 W/ cm².
10.2.7.3 – Interior Floor Finish –shall be classified based on NFPA 253 or ASTM E 648.
10.2.7.4 – Interior Floor – Classifications characteristics:
10.2.7.4.1 – Class I: Rad flux: min .45 W/cm².
10.2.7.4.2 – Class II: Rad flux: min .22 W/cm², and max. .45 W/cm².
10.2.8.1 – Wall and Ceiling finishes, where sprinkled:
Class C permitted in any location where Class B is req’d.
Class B permitted in any location where Class A is req’d.
10.2.8.2 – Floor finishes, where sprinkled:
Class II permitted in any location where Class I is req’d.
Provisions of 10.2.7.2 shall apply where Class II is req’d.
Chapter 19 - Existing Health Care Occupancies
19.1.6.1 - The existing building is a Hospital and therefore falls under Chapter 19.
19.2.5 - Arrangment of Means of Egress: No Change.
19.2.6 - Travel Distance to Exits: No Change
2018 NFPA 101 Life Safety Code Review Elevators 1-5, 6, 9-11, and 18 are part of building one. Elevator 18 is part of the MRI building addition.
Chapter 3
3.3.150 - Building One corresponds to definition of a hospital.
Chapter 6 Classification of Occupancy and Hazard of Contents
6.1.5 - Health Care Occupancy
Chapter 7 Means of Egress
7.1.3.1 - Exit Access Corridors: >30 occup load = 1-hr. fire rating.
Exception 1): Building is existing and occupancy classification has not changed.
7.1.3.2.1 – Exit Separation:
(1) The separation shall have a minimum 1-hr fire resistitance rating where the exit connects three or fewer stories.
7.3.1.2 – Occupant Load: No Change
7.3.2.2 – Max. projection within means of egress on ea. side: 4-1/2” (38” hgt. max.).
7.3.3.1 – Egress capacity (Health Care, sprinklered) Table 7.3.3.1- Stairs = .3” per occup; Level components and ramps = .2” per occup.
7.4.1.2 – Min. number of means of egress from any story = 2.
7.5.1.3.1 – Where more than 1 exit is required from building: shall be remotely located from each other.
7.5.1.3.3 – Remoteness of exits – Bldgs. protected by AFSS per 9.7, Min. separation distance between 2 exits = 1/3 max. overall diag. dimension of the area or bldg. served.
Chapter 8 Features of Fire Protection Table A.8.2.1.2 Fire Resistance Ratings for Type V (111) Construction (per Table 18.1.6.1)
Exterior Bearing Walls: 1 hour Interior Bearing Walls: 1 hour Columns: 1 hour Beams, Girders, Trusses: 1 hour Roof Ceiling Assemblies: 1 hour
*Basements are not counted as stories
Table 8.3.3.2.2 – Min Fire Protection for Openings in Fire-rated Assemblies:
Component Walls Fire Drs Vision Panel (size) FR Vision Panel FR Window Vert. shafts (stairs, exits):1 hr 1 hr Max tested D-H-60 NP Fire Barriers: 1 hr 3/4 hr Max tested D-H-45 3/4 hr
8.6.5 – Shafts- Req’d Fire Rating:
8.6.11.1 - Any concealed combustible space in which exposed building materials having a flame spread index greater than 25 when tested in accordance with 10.2.3, shall be draftstopped as follows:
(1) Every exterior and interior wall and partition shall be firestopped at each floor level, at the top-story ceiling level, and at the level of support for roofs.
(2) N/A See 8.6.11.2
(3) Any concealed space between the ceiling and the floor or roof above shall be draftsopped for the full depth of the space along the line of support for the floor or roof sructural members and, if necessary, at tother locations to form areas not to exceed 1,000 sqft for any space between the ceiling and floor, and 3000 sqft for any space between the ceiling and roof.
8.6.11.2 - The requirments of 8.6.11.1 shall not apply where any of the follwing conditions are met:
(1) Where the space is protected throughout by an approved automatic sprinkler system in accordance with Section 9.7.
S1.0-F
1-HR RATED
FIRE BARRIER
U.L. #U465
4 7/8"
9.219.21
9.02
9.80
7.82
7.82
STRUCTURE ABOVE
FIN. CEILING
FLOOR SLAB
S2.0-F
6 1/8"
9.219.21
7.82
7.82
2-HR RATED
FIRE BARRIER
U.L. #U419
9.80
9.219.21
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:3
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
CODE DATA
G100
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
NOTES
7.82 Continuous acoustic sealant @ non-rated walls / fire-rated sealant @ rated walls each side.
9.02 3 5/8" non-structural metal framing @ 16" o.c.
9.21 5/8" Type X gypsum board.
9.80 Acoustic insulation
Scale: 1/32" = 1'-0"1
GROUND FLOORN
DEDUCTS:
DEDUCT ALTERNATE 1: REMOVE ELEVATOR #18 FROM SCOPE OF WORK.
DEDUCT ALTERNATE 2: REMOVE ELEVATORS #18 AND #9 FROM SCOPE OF WORK.
DEDUCT ALTERNATE 3: REMOVE ELEVATORS #18, #9, AND #6 FROM SCOPE OF WORK.
N.T.S.Scale:
TEMPORARY WALL TYPE
N.T.S.Scale:
WALL TYPE
Revisions Date
PHASING:
PHASE 1: ELEVATOR 3 & 4
PHASE 2: ELEVATOR 2 & 5
PHASE 3: ELEVATOR 1 & 11
PHASE 4: ELEVATOR 6 & 10
PHASE 5: ELEVATOR 9 & 18
SD
R R
R R
R R
R R
E E
/8
A01
A01
ELEVATOR
PIT
DUCT SHAFT
PIPE
BASEMENT
8" 28'-8" 8"
E E
A01
A01
ELEVATOR 1 ELEVATOR 3ELEVATOR 2
DUCT SHAFT
14.0614.06 14.0614.0614.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06 14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.06 14.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06 14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.0614.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06 14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.06 14.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06
14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.06
14.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06
14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.06
14.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06 14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.0614.0614.06
E E
A01
A01
ELEVATOR 1 ELEVATOR 2 ELEVATOR 3
DUCT SHAFT
14.06 14.0614.06
14.0414.0414.0414.04
14.0814.08 14.0814.08 14.0814.08
14.0614.06 14.06
E E
F F
G G
A01
A01
A04
A04
PENTHOUSE
DUCT SHAFT
14.11 14.11 14.11
14.1214.13 14.12 14.1214.13 14.13
S2.0-FS2.0-F
S2.0-F
1.03
1.031.03
1.03
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
UPPER PENT.
158'-4 3/8"
PENT. ROOF
170'-9 3/8"
LOWER PENT.
146'-9 3/8"
PENTHOUSE
OVERSPEED
GOVERNOR
SUB-FLOOR
ELEVATOR 1
ELEVATOR
PIT
/4
T R
A V
E L D
IS
T
A N
C E
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
LEVEL 05 (FITH
FLOOR)
108'-9 3/8"
LEVEL 06 (SIXTH
FLOOR)
121'-5 3/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
UPPER PENT.
158'-4 3/8"
PENT. ROOF
170'-9 3/8"
LOWER PENT.
146'-9 3/8"
PENTHOUSE
OVERSPEED
GOVERNOR
SUB-FLOOR
ELEVATOR 2ELEVATOR 1 ELEVATOR 3
ELEVATOR
PIT
/8
/8
14.0714.0714.07
TYP.
E E
A01
A01
OVERSPEED
GOVERNOR
SUB-FLOOR
DUCT SHAFT
2.03
2.032.03
2.03
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:0
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATORS 1-3
A01
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"B
PIPE BASEMENT
Scale: 3/16" = 1'-0"G
GROUND FLOOR
Scale: 3/16" = 1'-0"1
1ST FLOOR
Scale: 3/16" = 1'-0"2
2ND FLOOR
Scale: 3/16" = 1'-0"3
3RD FLOOR
Scale: 3/16" = 1'-0"4
4TH FLOOR
Scale: 3/16" = 1'-0"5
5TH FLOOR
Scale: 3/16" = 1'-0"6
6TH FLOOR
Scale: 3/16" = 1'-0"7
7TH FLOOR
Scale: 3/16" = 1'-0"9
MACHINE ROOM
Scale: 1/8" = 1'-0"11
SECTION
Scale: 1/8" = 1'-0"10
SECTION
Scale: 3/16" = 1'-0"8
GOVERNOR SUBFLOOR
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all conditions in the field prior to fabrication, erection and construction.
G. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and specification 02 82 13.19 and local state and federal regulations.
Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
I. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
J. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
K. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
L. Elevator doors shall be removed and replaced one at a time per elevator shaft. New doors are to be installed immediately upon the removal of the existing door or a temporary rated partition must be installed to enclose the opening. Coordinate locations of partitions with C.O.R.
M. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction. Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
N. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
O. Temporary partition to structural deck above.
P. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
Q. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
R. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
GENERAL NOTES
N N.T.S.Scale:
KEY PLAN
NOTES
1.03 Install new fire barrier partition wall where security cage was demolished. Install new double door where gate was demolished. See A04/10 for demo plan.
2.03 Existing wall to remain.
14.04 Elevator Contractor to provide continuous hoistway fascia as required.
14.06 Elevator Contractor to wrap all entrance frames with stainless steel cladding as specified.
14.07 Existing hoistway sills to remain in place.
14.08 Existing guide rails to be retained as needed.
14.11 Block up hoist machine as required to provide proper arc of contact of hoist ropes on the drive sheave and to access the deflector sheave in the machine room. Provide steel checker-plate over machine beams to eliminate any tripping hazard, and create working platform.
14.12 Provide 3-phase mainline power feeder with disconnecting means for each elevator controller. Provide 1-phase feeder with disconnecting means for car lighting, ventilation system and receptacle for each elevator. These disconnecting means shall include overcurrent protection, shall be located in the machine room, and shall meet N.E.C. requirements.
14.13 For equipment in the machine room, a clearance of not less than 18" shall be provided in the directions(s) required for maintenance, and a clear path of not less than 18" shall be provided to all components that require maintenance.
N
HD
R R
R R
R R
R R
UP
F F
8" 18'-1" 8"
/2
A04
A04
ELEVATOR
PIT
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL G -
ELEVATOR
LOBBY
14.0614.06 14.0614.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 01 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.0614.06
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 02 -
ELEVATOR
LOBBY
14.06
14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.06
14.06
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 03 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 04 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.0614.06
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 05 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.06 14.06
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 06 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.0614.06
F F
A04
A04
ELEVATOR 4 ELEVATOR 5
LVL 07 -
ELEVATOR
LOBBY
14.06 14.06
14.0814.08
14.0414.0414.0414.04
14.0814.08
14.06 14.06
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
LEVEL 05 (FITH
FLOOR)
108'-9 3/8"
LEVEL 06 (SIXTH
FLOOR)
121'-5 3/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
UPPER PENT.
158'-4 3/8"
PENT. ROOF
170'-9 3/8"
LOWER PENT.
146'-9 3/8"
PENTHOUSE
OVERSPEED
GOVERNOR
SUB-FLOOR
ELEVATOR 4
ELEVATOR
PIT
T R
A V
E L D
IS
T
A N
C E
/4
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
LEVEL 05 (FITH
FLOOR)
108'-9 3/8"
LEVEL 06 (SIXTH
FLOOR)
121'-5 3/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
UPPER PENT.
158'-4 3/8"
PENT. ROOF
170'-9 3/8"
LOWER PENT.
146'-9 3/8"
PENTHOUSE
ELEVATOR
PIT
ELEVATOR 4 ELEVATOR 5
OVERSPEED
GOVERNOR
SUB-FLOOR
14.0714.07
TYP.
F F
A04
A04
OVERSPEED
GOVERNOR
SUB-FLOOR
LOWER
PENTHOUSE
E E
F F
G G
A01
A01
A04
A04
PENTHOUSE
AD01
14.11 14.12
14.13 14.11
14.12
14.13
S2.0-FS2.0-F
S2.0-F
1.03
1.031.03
1.03
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
PENTHOUSE
2.50
2.50
2.50
2.51
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:1
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATORS 4-5
A04
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"B
PIPE BASEMENT
Scale: 3/16" = 1'-0"G
GROUND FLOOR
Scale: 3/16" = 1'-0"1
1ST FLOOR
Scale: 3/16" = 1'-0"2
2ND FLOOR
Scale: 3/16" = 1'-0"3
3RD FLOOR
Scale: 3/16" = 1'-0"4
4TH FLOOR
Scale: 3/16" = 1'-0"5
5TH FLOOR
Scale: 3/16" = 1'-0"6
6TH FLOOR
Scale: 3/16" = 1'-0"7
7TH FLOOR
Scale: 1/8" = 1'-0"11
SECTION
Scale: 1/8" = 1'-0"12
SECTION
Scale: 3/16" = 1'-0"8
GOVERNOR SUBFLOOR
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all conditions in the field prior to fabrication, erection and construction.
G. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and specification 02 82 13.19 and local state and federal regulations.
Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
I. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
J. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
K. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
L. Elevator doors shall be removed and replaced one at a time per elevator shaft. New doors are to be installed immediately upon the removal of the existing door or a temporary rated partition must be installed to enclose the opening. Coordinate locations of partitions with C.O.R.
M. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction. Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
N. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
O. Temporary partition to structural deck above.
P. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
Q. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
R. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
GENERAL NOTES
Scale: 3/16" = 1'-0"9
MACHINE ROOM
N N.T.S.Scale:
KEY PLAN
NOTES
1.03 Install new fire barrier partition wall where security cage was demolished. Install new double door where gate was demolished. See A04/10 for demo plan.
2.50 Remove existing security cage.
2.51 Remove existing gate.
14.04 Elevator Contractor to provide continuous hoistway fascia as required.
14.06 Elevator Contractor to wrap all entrance frames with stainless steel cladding as specified.
14.07 Existing hoistway sills to remain in place.
14.08 Existing guide rails to be retained as needed.
14.11 Block up hoist machine as required to provide proper arc of contact of hoist ropes on the drive sheave and to access the deflector sheave in the machine room. Provide steel checker-plate over machine beams to eliminate any tripping hazard, and create working platform.
14.12 Provide 3-phase mainline power feeder with disconnecting means for each elevator controller. Provide 1-phase feeder with disconnecting means for car lighting, ventilation system and receptacle for each elevator. These disconnecting means shall include overcurrent protection, shall be located in the machine room, and shall meet N.E.C. requirements.
14.13 For equipment in the machine room, a clearance of not less than 18" shall be provided in the directions(s) required for maintenance, and a clear path of not less than 18" shall be provided to all components that require maintenance.
N
Scale: 3/16" = 1'-0"10
MACHINE ROOM DEMO
R R
R
HD
L L
8" 8'-10" 8"
A06
A06
ELEVATOR
PIT
PIPE
BASEMENT
L L
A06
A06
ELEVATOR 6
ELEVATOR
LOBBY
STAIR #3
GD-003
14.0814.08
14.0414.0414.0414.04
14.0614.06
L L
A06
A06
ELEVATOR 6
ELEVATOR
LOBBY
ELEC.
STAIR #3
14.0614.06
14.0814.08
14.0414.0414.0414.04
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
ELEVATOR 6
ELEVATOR
PIT
T R
A V
E L D
IS
T
A N
C E
/4
ELEVATOR
MACHINE
ROOM
14.07
14.07
14.07
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
L
ELEVATOR
PIT
ELEVATOR 6
ELEVATOR
MACHINE
ROOM
L L
A06
A06
ELEVATOR 6
ELEVATOR
LOBBY
ELEC.
STAIR #3
ANESTHOLOGY
MD
ANESTOLOGY
MD
14.0614.06
14.0814.08
14.0414.0414.0414.04
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
L L
A06
A06
ELEVATOR
MACHINE
ROOM
14.12
8" 10'-0" 8"
/8
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:1
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATOR 6
A06
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"1
PIPE BASEMENT
Scale: 3/16" = 1'-0"2
GROUND FLOOR
Scale: 3/16" = 1'-0"3
1ST FLOOR
Scale: 1/8" = 1'-0"5
SECTION
Scale: 1/8" = 1'-0"6
SECTION
Scale: 3/16" = 1'-0"4
2ND FLOOR
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all conditions in the field prior to fabrication, erection and construction.
G. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and specification 02 82 13.19 and local state and federal regulations.
Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
I. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
J. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
K. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
L. Elevator doors shall be removed and replaced one at a time per elevator shaft. New doors are to be installed immediately upon the removal of the existing door or a temporary rated partition must be installed to enclose the opening. Coordinate locations of partitions with C.O.R.
M. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction. Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
N. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
O. Temporary partition to structural deck above.
P. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
Q. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
R. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
GENERAL NOTES
N N.T.S.Scale:
KEY PLAN
NOTES
14.04 Elevator Contractor to provide continuous hoistway fascia as required.
14.06 Elevator Contractor to wrap all entrance frames with stainless steel cladding as specified.
14.07 Existing hoistway sills to remain in place.
14.08 Existing guide rails to be retained as needed.
14.12 Provide 3-phase mainline power feeder with disconnecting means for each elevator controller. Provide 1-phase feeder with disconnecting means for car lighting, ventilation system and receptacle for each elevator. These disconnecting means shall include overcurrent protection, shall be located in the machine room, and shall meet N.E.C. requirements.
Scale: 3/16" = 1'-0"8
MACHINE ROOM
SD HD
R R R R
SD
SD
HD
SD
B B
C C
1'-4" 7'-9 1/2" 1'-4"
/8
A09
A09
/8
/8
/8
1'-0 5/8" 7'-7 3/8" 10" 7'-9 1/2" 1'-4"
STAIR #9
LOBBY
ELEVATOR
EQUIP.
ELEVATOR 9
14.0614.06
14.09
14.11 14.12
14.13
14.1114.1114.11
14.0814.08
14.0414.0414.0414.04
B B
A09
A09
ELEVATOR 9
STORAGE LOBBY
EMERGENCY
ISOLATION
ROOM
EMERGENCY
ISOLATION
ROOM
14.0814.08
14.0414.0414.0414.04
14.0614.06
B B
A09
A09
LOBBYSTORAGE
ELEVATOR 9
14.0414.0414.0414.04
14.0814.08
14.0614.06
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
B
ELEVATOR PIT
30'-2 5/8"
ELEVATOR
PIT
ELEVATOR 9
14.09
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
T R
A V
E L D
IS
T
A N
C E
/8
ELEVATOR 9
ELEVATOR PIT
30'-2 5/8"
ELEVATOR
PIT
14.0914.0714.07
14.07
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:1
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATOR 9
A09
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"1
BASEMENT
Scale: 3/16" = 1'-0"3
1ST FLOOR
Scale: 3/16" = 1'-0"2
GROUND FLOOR
Scale: 1/8" = 1'-0"4
SECTION
Scale: 1/8" = 1'-0"5
SECTION
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all conditions in the field prior to fabrication, erection and construction.
G. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and specification 02 82 13.19 and local state and federal regulations.
Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
I. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
J. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
K. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
L. Elevator doors shall be removed and replaced one at a time per elevator shaft. New doors are to be installed immediately upon the removal of the existing door or a temporary rated partition must be installed to enclose the opening. Coordinate locations of partitions with C.O.R.
M. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction. Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
N. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
O. Temporary partition to structural deck above.
P. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
Q. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
R. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
GENERAL NOTES
N N.T.S.Scale:
KEY PLAN
NOTES
14.04 Elevator Contractor to provide continuous hoistway fascia as required.
14.06 Elevator Contractor to wrap all entrance frames with stainless steel cladding as specified.
14.07 Existing hoistway sills to remain in place.
14.08 Existing guide rails to be retained as needed.
14.09 Elevator Contractor to provide pit access ladders.
14.11 Block up hoist machine as required to provide proper arc of contact of hoist ropes on the drive sheave and to access the deflector sheave in the machine room. Provide steel checker-plate over machine beams to eliminate any tripping hazard, and create working platform.
14.12 Provide 3-phase mainline power feeder with disconnecting means for each elevator controller. Provide 1-phase feeder with disconnecting means for car lighting, ventilation system and receptacle for each elevator. These disconnecting means shall include overcurrent protection, shall be located in the machine room, and shall meet N.E.C. requirements.
14.13 For equipment in the machine room, a clearance of not less than 18" shall be provided in the directions(s) required for maintenance, and a clear path of not less than 18" shall be provided to all components that require maintenance.
HD SD
G G
H H
10"
/8
10' - 3 3/8" 8"
A10
A10
14.09
ELEVATOR
PIT
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.09
14.0614.06
14.0614.06 14.0814.08
14.0814.08
14.0414.0414.0414.04
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.06
14.06
14.06
14.06 14.0814.08
14.0814.08
14.0414.0414.0414.04
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
G G
H H
A10
A10
ELEVATOR 11
ELEVATOR 10
14.0814.08
14.0814.08
14.0414.0414.0414.04
14.06
14.06
14.06
14.06
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
LEVEL 05 (FITH
FLOOR)
108'-9 3/8"
LEVEL 06 (SIXTH
FLOOR)
121'-5 3/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
GH
LOWER PENT.
146'-9 3/8"
ELEVATOR
PENTHOUSE
(UPPER)
ELEVATOR 11
ELEVATOR
PIT
/4
T R
A V
E L D
IS
T
A N
C E
/4
ELEVATOR 10
14.09
14.0714.07
TYP.
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
LEVEL 03 (THIRD
FLOOR)
83'-5 3/8"
LEVEL 04 (FOURTH
FLOOR)
96'-1 3/8"
LEVEL 05 (FITH
FLOOR)
108'-9 3/8"
LEVEL 06 (SIXTH
FLOOR)
121'-5 3/8"
LEVEL 07 (SEVENTH
FLOOR)
134'-1 3/8"
LOWER PENT.
146'-9 3/8"
ELEVATOR
PENTHOUSE
(UPPER)
ELEVATOR 10
ELEVATOR
PIT
F F
G G
H H
A10
A10
ELEVATOR
PENTHOUSE
(LOWER)
14.11 14.12
14.13
14.11 14.12
14.13
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:2
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATORS 10-11
A10
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"B
PIPE BASEMENT
Scale: 3/16" = 1'-0"G
GROUND FLOOR
Scale: 3/16" = 1'-0"1
1ST FLOOR
Scale: 3/16" = 1'-0"2
2ND FLOOR
Scale: 3/16" = 1'-0"3
3RD FLOOR
Scale: 3/16" = 1'-0"4
4TH FLOOR
Scale: 3/16" = 1'-0"5
5TH FLOOR
Scale: 3/16" = 1'-0"6
6TH FLOOR
Scale: 3/16" = 1'-0"7
7TH FLOOR
Scale: 1/8" = 1'-0"8
SECTION
Scale: 1/8" = 1'-0"9
SECTION
Scale: 3/16" = 1'-0"10
PENTHOUSE
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all conditions in the field prior to fabrication, erection and construction.
G. All asbestos containing material (ACM) must be abated per the direction of the C.O.R. and project specification 017419 and specification 02 82 13.19 and local state and federal regulations.
Abatement if required is to be scheduled in appropriate sequence with demolition, new construction and project phasing.
I. Coordinate phase completion and start-up with requirements as set forth by the C.O.R. to maintain daily operations to near as normal as possible.
J. Coordinate location of job dumpster with the C.O.R. so as to disrupt daily operations as little as possible.
K. Coordinate access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
L. Elevator doors shall be removed and replaced one at a time per elevator shaft. New doors are to be installed immediately upon the removal of the existing door or a temporary rated partition must be installed to enclose the opening. Coordinate locations of partitions with C.O.R.
M. Existing HVAC, medical gases, sprinklers and water supply to be maintained throughout as required during each phase of construction. Coordinate phasing with Mechanical and Plumbing contractor. Support and protect all lines during each phase of construction. See MEP Drawings.
N. Provide and maintain negative air pressure at all construction.
Coordinate with HVAC contractor. See HVAC plans for temporary venting requirements and duct locations.
O. Temporary partition to structural deck above.
P. Existing power must be maintained throughout as required during each phase of construction.Coordinate phasing with Electrical Contractor. Coordinate power turnover with requirements as dictated by the C.O.R. See Electrical Drawings.
Q. Coordinate sequence construction with C.O.R. so that only one side of any corridor in use is obstructed at any one time.
R. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the C.O.R.
GENERAL NOTES
N N.T.S.Scale:
KEY PLAN
NOTES
14.04 Elevator Contractor to provide continuous hoistway fascia as required.
14.06 Elevator Contractor to wrap all entrance frames with stainless steel cladding as specified.
14.07 Existing hoistway sills to remain in place.
14.08 Existing guide rails to be retained as needed.
14.09 Elevator Contractor to provide pit access ladders.
14.11 Block up hoist machine as required to provide proper arc of contact of hoist ropes on the drive sheave and to access the deflector sheave in the machine room. Provide steel checker-plate over machine beams to eliminate any tripping hazard, and create working platform.
14.12 Provide 3-phase mainline power feeder with disconnecting means for each elevator controller. Provide 1-phase feeder with disconnecting means for car lighting, ventilation system and receptacle for each elevator. These disconnecting means shall include overcurrent protection, shall be located in the machine room, and shall meet N.E.C. requirements.
14.13 For equipment in the machine room, a clearance of not less than 18" shall be provided in the directions(s) required for maintenance, and a clear path of not less than 18" shall be provided to all components that require maintenance.
R R
8" 8"10'-4"
" 4
A18
A18
ELEVATOR 18
14.09
CB-6e
14.08
14.04
14.08
14.0414.0414.04
14.0614.06
14.1114.1114.1114.11 14.12
14.13
13'-0 5/16" to back of shelf 5" 7'-9 43/256"
11'-5 1/2" to front of shelf wall
R R
A18
A18
ELEVATOR 18
CORRIDOR
CORRIDOR
Room
14.08
14.04
14.08
14.0414.0414.04
14.0614.0614.0614.06
11 12
R R
A18
A18
CORRIDOR
GC-032
GURNEY
STAGE
GC-020
WAITING
GC-024
ELEVATOR 18
14.08
14.04
14.08
14.0414.0414.04
14.0614.0614.0614.06
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
11 12
ELEVATOR PIT
30'-2 5/8"
/8
/8
"ELEVATOR
PIT
ELEVATOR 18
14.09
22.07
LEVEL B (PIPE
BASEMENT)
34'-2 5/8"
LEVEL G (GROUND
FLOOR)
43'-2 5/8"
LEVEL 01 (FIRST
FLOOR)
57'-0"
LEVEL 02 (SECOND
FLOOR)
70'-9 3/8"
R
ELEVATOR PIT
30'-2 5/8"
ELEVATOR 18
ELEVATOR
PIT
14.09
14.0714.07
14.07
T R
A V
E L D
IS
T
A N
C E
/8
ELEVATOR 10 & 11
ELEVATOR 9
ELEVATOR 18
ELEVATOR 6
ELEVATOR 4 & 5
ELEVATOR 1, 2 & 3
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
R O G E
R
A. REP
S T I E N
AR0012462
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
35%SD SCHEMATIC DESIGN 06/24/2022
65%DD DESIGN DEVELOPMENT 09/07/2022
95%CD CONSTRUCTION DOCUMENT 10/24/2022
/3
/2
:1
:2
P
M
JAMES A. HALEY RENO &
REPLACE ELEVATORS
03.31.23
ELEVATOR 18
A18
ACKR
673-14-104
TAMPA FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 21029.00
Scale: 3/16" = 1'-0"1
BASEMENT
Scale: 3/16" = 1'-0"3
1ST FLOOR
Scale: 3/16" = 1'-0"2
GROUND FLOOR
Scale: 1/8" = 1'-0"4
SECTION
Scale: 1/8" = 1'-0"5
SECTION
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. All wood blocking to be fire retardent treated.
D. Elevator Contractor to provide 42" car-top railing as needed per code.
E. Coordinate light fixtures and utility outlet locations with Elevator Contractor.
F. Verify all…
This is the start of the file's text. The full file is on GovTribe.