2-HANOVER TOWNSHIP 2025 COMMUNITY DEVELOPMENT BLOCK GRANT PLANS.pdf
PDF 4 MB Posted
- Solicitation number
- US.199555
- Issued by
- Luzerne County, Arona Borough, Pennsylvania
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CALL BEFORE YOU DIG!
PENNSYLVANIA LAW REQUIRES
3 WORKING DAYS NOTICE FOR
CONSTRUCTION PHASE AND 10 WORKING
DAYS IN DESIGN STAGE - STOP CALL
Pennsylvania One Call System, Inc.
1-800-242-1776
COMCAST (USIC LOCATING SERVICES)
9045 N RIVER ROAD STE 300
INDIANAPOLIS, IN. 46240
CONTACT: JEFFREY TRUMBOWER
EMAIL: JeffTrumbower@usicllc.com
PHONE: 317-810-8254
ETECH
1903 BERRY DRIVE
NACOGDOCHES, TX 75965
CONTACT: CAROLYN WINGATE
EMAIL: carolyn.wingate@etechtexas.com
PHONE: 936-645-3303
UGI UTILITIES WILKES BARRE (GAS)
1 UGI DRIVE
WILKES-BARRE, PA 18711
CONTACT: AMANDA NIXON
EMAIL: anixon@ugi.com
PHONE: 570-829-8874
VERIZON PENNSYLVANIA LLC
1050 VIRGINIA DRIVE
FORT WASHINGTON, PA 19034
CONTACT: DIANE REDILLA
EMAIL: diane.c.redilla@verizon.com
PHONE: 215-591-6210
HANOVER TOWNSHIP SEWER
1267 SANS SOUCI PKWY
HANOVER, TOWNSHIP, PA 18706
CONTACT: MICHAEL MAZUR
EMAIL: mmazur@hanovertownship.org
PHONE: 570-825-1257
SERVICE ELECTRIC CABLE TV INC.
15 J CAMPBELL COLLINS DRIVE
WILKES BARRE, PA 18702
CONTACT: MIKE LABUDA
EMAIL: labudam@sectv.com
PHONE: 570-825-8508
UGI UTILITIES INC (ELECTRIC)
1 UGI CENTER
WILKES-BARRE, PA 18711
CONTACT: JONATHAN GENSEL
EMAIL: jgensel@ugi.com
PHONE: 570-407-0648
PENNSYLVANIA AMERICAN WATER
2699 STAFFORD AVENUE
SCRANTON, PA 18507
CONTACT: LISA ABDO
EMAIL: lisa.abdo@amwater.com
PHONE: 570-969-7501
UTILITY CONTACT INFORMATION
REVISIONS
DATENO. DESCRIPTION
SEAL DRAWN BY
CHECKED BY
DATE
PROJECT NUMBER
DRAWING NUMBER
\\v er da nt as .c om \d fs \P ro je ct F ile s\
G A-
H Z\
H
AN
TW
P\
- 2
H an ov er
T w p G en er al E ng in ee rin g\
0-
C
D
BG
P av in g\
-C
AD
D
\S H
EE
T\
C S1
.d w g
- 5
/1 3/
:4
PM
LOCATION MAP
THE CONTRACTOR WILL BE RESPONSIBLE TO
CONTACT THE PENNSYLVANIA ONE-CALL NUMBER AT
1-800-242-1776 NOT LESS THAN THREE (3), NOR MORE
THAN TEN (10) WORKING DAYS PRIOR TO THE START
OF WORK TO HAVE ALL UTILITIES MARKED IN THE
AREAS OF WORK.
PA ONE CALL NUMBER 20252233543
LUZERNE COUNTY, PENNSYLVANIA
HANOVER TOWNSHIP
2025 COMMUNITY DEVELOPMENT BLOCK GRANT PAVING PROJECT
GENERAL NOTES:
1. STREET EDGE OF PAVED CARTWAYS ARE NOT SHOWN TO SCALE.
2. LIMITS OF PAVE WORK (L.O.W.) INDICATED ON DRAWING MAY BE ADJUSTED BY ENGINEER
DURING CONSTRUCTION BASED UPON ACTUAL FIELD CONDITIONS.
3. THE PLAN(S) AND TYPICAL SECTION(S) DEPICT THE GENERAL LAYOUT, LENGTH, SCOPE AND
LIMIT OF WORK. THEY MAY NOT INDICATE ALL SITE SPECIFIC CONDITIONS THAT WILL NEED
TO BE ADDRESSED DURING CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE TO
THOROUGHLY EXAMINE ALL EXISTING CONDITIONS OF THE SITE PRIOR TO SUBMITTING A BID
SO AS TO IDENTIFY ANY SITE SPECIFIC CONDITIONS THAT MAY AFFECT THEIR BID.
4. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ENGINEER ANY SITE SPECIFIC
CONDITION THAT MAY REQUIRE SPECIAL ATTENTION DURING CONSTRUCTION PRIOR TO THE
COMMENCEMENT OF WORK.
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT THE PENNSYLVANIA ONE-CALL
NUMBER AT 1-800-242-1776 NOT LESS THAN THREE (3), NOR MORE THAN TEN (10) WORKING
DAYS PRIOR TO THE START OF WORK TO HAVE ALL UTILITIES MARKED IN THE AREAS OF
WORK. THE CONTRACTOR WILL BE RESPONSIBLE TO CONTACT DIRECTLY, ANY UTILITY NOT
LISTED ON THE DRAWING, OR NOT ON RECORD WITH THE PENNSYLVANIA ONE-CALL SYSTEM.
6. CONTRACTOR SHALL FIELD VERIFY EXISTING SITE CONDITIONS AND UTILITY LOCATIONS
PRIOR TO CONSTRUCTION.
7. IN ADDITION TO CONTRACT DOCUMENTS, THIS PROJECT SHALL BE CONSTRUCTED IN
ACCORDANCE WITH THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION
SPECIFICATIONS PUBLICATION 408 AND PENNSYLVANIA DEPARTMENT OF TRANSPORTATION
STANDARDS FOR ROADWAY CONSTRUCTION, LATEST EDITIONS, UNLESS OTHERWISE
NOTED, SPECIFIED, OR DIRECTED.
8. ALL NECESSARY TRAFFIC CONTROL AND OTHER REQUIRED MAINTENANCE AND PROTECTION
OF TRAFFIC SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE IN
ACCORDANCE WITH THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION PUBLICATIONS
212, 213, AND 236.
9. TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH PENNDOT PUBLICATION 212,
OFFICIAL TRAFFIC CONTROL DEVICES, LATEST EDITION.
10. CONTRACTOR SHALL COORDINATE WITH ALL EMERGENCY SERVICE PROVIDERS INCLUDING,
BUT NOT LIMITED TO HANOVER TOWNSHIP POLICE DEPARTMENT, HANOVER TOWNSHIP FIRE
DEPARTMENT AND HANOVER TOWNSHIP AMBULANCE ASSOCIATIONS TO NOTIFY THEM OF
PROJECT WORK SCHEDULE.
11. MILLINGS FOR THE PROJECT ARE TO BE RETAINED BY HANOVER TOWNSHIP. CONTRACTOR
SHALL BE RESPONSIBLE FOR COORDINATION WITH OWNER'S DPW STAFF FOR THE DELIVERY
AND STOCKPILING OF THE MILLINGS. THE MILLINGS ARE TO BE TAKEN TO SAGAR'S SERVICE
CENTER, WHICH IS AT 4 BREAKER ROAD, WILKES-BARRE, PA 18706.
12. LOCATIONS OF ALL BIT. CONC. BASE REPLACEMENT SHALL BE AS DIRECTED BY THE
ENGINEER AND SHALL BE MARKED IN THE FIELD FOLLOWING THE COMPLETION OF ALL FULL
WIDTH MILLING OPERATIONS.
13. MILLING AND/OR SAWCUTTING FOR CARTWAY PAVEMENT TIE-INS SHALL BE INCIDENTAL TO
THE FULL WIDTH OVERLAY.
14. CRAFCO SUPERFLEX ASPHALT CEMENT SHALL BE USED TO SEAL ALL PAVEMENT JOINTS.
15. CONTRACTOR SHALL BE RESPONSIBLE TO UNDERTAKE NECESSARY STEPS TO INSURE A
FINAL CROWN GRADE OF 2.0% MINIMUM OR MATCH EXISTING CROWN GRADES (WHICHEVER
IS GREATER) IN BOTH DIRECTIONS WHETHER IT BE BY MILLING OR BUILT UP WITH AN
ADDITIONAL BIT. CONC. WEARING AND/OR BINDER COURSE MATERIAL, OR A COMBINATION
OF BOTH. THIS WORK SHALL BE INCIDENTAL TO AND INCLUDED IN THE COST OF THE MILLING, BINDER COURSE, AND/OR WEARING COURSE APPLICATIONS FOR THE SELECTED WORK.
16. NO LESS THAN EXISTING CURB REVEAL SHALL BE MAINTAINED AT THOSE LOCATIONS
WHERE THERE IS EXISTING CURB.
17. SAWCUT LIMITS OF WORK AT BOTH ENDS PRIOR TO START OF MILLING OPERATIONS
(INCIDENTAL).
18. SAWCUT FULL DEPTH OF EXISTING PAVEMENT STRUCTURE WHERE ADJACENT TO AND
FLUSH WITH ADJOINING BIT. CONC. PAVED AREAS PRIOR TO START OF MILLING OPERATIONS
(INCIDENTAL).
19. ALL MANHOLE, INLET AND UTILITY CASTINGS REQUIRING FINISHED GRADE ADJUSTMENT
SHALL BE PROPERLY ADJUSTED PRIOR TO THE PLACEMENT OF THE SPECIFIED BIT. CONC.
WEARING COURSE OVERLAY. UTILITY CASTINGS SHALL BE ADJUSTED BY THE APPLICABLE
MUNICIPAL AUTHORITY AND/OR UTILITY. CONTRACTOR SHALL COORDINATE THIS WORK
ACCORDINGLY.
20. MAINTAIN ACCESS TO DRIVEWAYS AT ALL TIMES. PLACE WEDGE WITH MILLED MATERIAL FOR
DURATION BETWEEN MILLING AND FINAL PAVING OPERATION. MAINTAIN MILLED WEDGE AS
NECESSARY TO MAINTAIN DRIVEWAY ACCESS.
0' 2000' 4000' 6000'
GRAPHIC SCALE (IN FEET)
BMS
LSS
2025.08.11
31749
CS1
LOUIS S. SPACIANO
PROFESSIONAL
NO. PE080706
REGISTERED
ENGINEER
SHEET LIST TABLE
CS1
C-201
C-202
C-203
C-901
COVER SHEET
PLAN AND TYPICAL SECTION - TANYA DRIVE (1 OF 2)
PLAN AND TYPICAL SECTION - TANYA DRIVE (2 OF 2)
SITE DETAILS
MAINTENANCE AND PROTECTION OF TRAFFIC DETAILS
SHEET TITLESheet Number
TANYA DRIVE PROJECT LOCATION
ASPHALT CURB
ASPHALT CURB
MANHOLE FRAME
TO REMAIN
EXISTING INLET TO REMAIN
RECONSTRUCT EXISTING INLET FRAME & GRATE TO REDUCE
ELEVATION (1 INCH MAX) TO ALLOW POSITIVE DRAINAGE
MANHOLE FRAME AND
COVER TO REMAIN
DRAWING NUMBER
PROJECT NUMBER
DATE
CHECKED BY
DRAWN BYDRAWING TITLE & PROJECT NAMEREVISIONS
DESCRIPTIONDATENO.
OR
1-800-242-1776
CALL
PA ONE CALL
SYSTEM TOLL
FREE
THREE DAYS
BEFORE
YOU DIGKnow what's below.
Call before you dig.
SEALS
Z:
\P ro je ct F ile s\
G A-
H Z\
H
AN
TW
P\
- 2
H an ov er
T w p G en er al E ng in ee rin g\
0-
C
D
BG
P av in g\
-C
AD
D
\S H
EE
T\
C
BD
G .d w g
5/
/2
5:
P M
R
0' 40' 80' 120'
GRAPHIC SCALE (IN FEET)
PLAN AND TYPICAL SECTION - TANYA DRIVE ( 1 OF 2)
HANOVER TOWNSHIP
2025 COMMUNITY DEVELOPMENT BLOCK GRANT
PAVING PROJECT
HANOVER TOWNSHIP,LUZERNE COUNTY, PENNSYLVANIA
BMS
LSS
2025.08.11
31749
C-201
PLAN
LIMIT OF MILL & OVERLAY
ASPHALT CONCRETE CURB REPLACEMENT
EXISTING STORM INLET
EXISTING MANHOLE
LEGEND
LOUIS S. SPACIANO
PROFESSIONAL
NO. PE080706
REGISTERED
ENGINEER
TYPICAL SECTION
TANYA DRIVE - MILL AND OVERLAY
NOT TO SCALE
MAINTAIN MIN 2% CROWN CROSS-SECTIONS GRADES
OR MATCH EXISTING, WHICHEVER IS GREATER
3 1/2" FULL WIDTH MILLING
EXISTING BIT CONC
PAVEMENT STRUCTURE
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA FULL WIDTH BIT. CONC. BINDER COURSE
STRUCTURAL OVERLAY, PG 64-22, 0.0 TO 0.3
MILLION ESALS 19.0MM MIX, MINIMUM 2"
COMPACTED DEPTH, SRL-L (TYP)
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA FULL WIDTH BIT. CONC. WEARING COURSE,
PG 64-22 0.0 TO 0.3 MILLION ESALS 9.5MM MIX,
1-1/2" COMPACTED DEPTH, SRL-L (TYP)
COAT EDGES AND
JOINTS WITH CRAFCO
SUPERFLEX ASPHALT
CEMENT (TYP)
BIT CONC SCRATCH LEVELING COURSE (AS DIRECTED)
LIMIT OF WORK
TANYA DRIVE INTERSECTION WITH SOUTH MAIN STREET
NOT TO SCALE
GENERAL NOTES:
1. CONTRACTOR TO PROTECT AND MAINTAIN EXISTING DRAINAGE STRUCTURES DURING
ASPHALT CONCRETE CURB REPLACEMENT.
2. CONTRACTOR TO PROTECT AND MAINTAIN EXISTING LANDSCAPING AND DECORATIONS
DURING ASPHALT CONCRETE CURB REPLACEMENT.
AutoCAD SHX Text
SOUTH MAIN STREET
AutoCAD SHX Text
TANYA DRIVE
AutoCAD SHX Text #2440
AutoCAD SHX Text #2436
AutoCAD SHX Text #2434
AutoCAD SHX Text #1
AutoCAD SHX Text #12
AutoCAD SHX Text #14
AutoCAD SHX Text #18
AutoCAD SHX Text #20
AutoCAD SHX Text #22
AutoCAD SHX Text #2437
AutoCAD SHX Text #2445
AutoCAD SHX Text #2435
AutoCAD SHX Text #2433
AutoCAD SHX Text #2431
AutoCAD SHX Text #2427
AutoCAD SHX Text
MATCHLINE SEE SHEET C-202
AutoCAD SHX Text
MATCHLINE SEE SHEET C-202
AutoCAD SHX Text 2.00%
AutoCAD SHX Text 2.00%
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text
EXISTING ROLLED BITUMINOUS CURB (TYP BOTH SIDES)
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EXISTING GRADE (TYP)
AutoCAD SHX Text
EOP
AutoCAD SHX Text
PAVING LIMIT
AutoCAD SHX Text
EXISTING GRADE (TYP)
MANHOLE FRAME AND
COVER TO REMAIN
EXISTING INLET TO REMAIN
EXISTING INLET TO REMAIN
DRAWING NUMBER
PROJECT NUMBER
DATE
CHECKED BY
DRAWN BYDRAWING TITLE & PROJECT NAMEREVISIONS
DESCRIPTIONDATENO.
OR
1-800-242-1776
CALL
PA ONE CALL
SYSTEM TOLL
FREE
THREE DAYS
BEFORE
YOU DIGKnow what's below.
Call before you dig.
SEALS
Z:
\P ro je ct F ile s\
G A-
H Z\
H
AN
TW
P\
- 2
H an ov er
T w p G en er al E ng in ee rin g\
0-
C
D
BG
P av in g\
-C
AD
D
\S H
EE
T\
C
BD
G .d w g
5/
/2
5:
P M
R
0' 40' 80' 120'
GRAPHIC SCALE (IN FEET)
PLAN AND TYPICAL SECTION - TANYA DRIVE (2 OF 2)
HANOVER TOWNSHIP
2025 COMMUNITY DEVELOPMENT BLOCK GRANT
PAVING PROJECT
HANOVER TOWNSHIP,LUZERNE COUNTY, PENNSYLVANIA
BMS
LSS
2025.08.11
31749
C-202
PLAN LEGEND
LOUIS S. SPACIANO
PROFESSIONAL
NO. PE080706
REGISTERED
ENGINEER
TYPICAL SECTION
TANYA DRIVE - MILL AND OVERLAY
NOT TO SCALE
LIMIT OF MILL & OVERLAY
ASPHALT CONCRETE CURB REPLACEMENT
EXISTING STORM INLET
EXISTING MANHOLE
GENERAL NOTES:
1. CONTRACTOR TO PROTECT AND MAINTAIN EXISTING DRAINAGE STRUCTURES DURING
ASPHALT CONCRETE CURB REPLACEMENT.
2. CONTRACTOR TO PROTECT AND MAINTAIN EXISTING LANDSCAPING AND DECORATIONS
DURING ASPHALT CONCRETE CURB REPLACEMENT.
MAINTAIN MIN 2% CROWN CROSS-SECTIONS GRADES
OR MATCH EXISTING, WHICHEVER IS GREATER
3 1/2" FULL WIDTH MILLING
EXISTING BIT CONC
PAVEMENT STRUCTURE
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA FULL WIDTH BIT. CONC. BINDER COURSE
STRUCTURAL OVERLAY, PG 64-22, 0.0 TO 0.3
MILLION ESALS 19.0MM MIX, MINIMUM 2"
COMPACTED DEPTH, SRL-L (TYP)
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA FULL WIDTH BIT. CONC. WEARING COURSE,
PG 64-22 0.0 TO 0.3 MILLION ESALS 9.5MM MIX,
1-1/2" COMPACTED DEPTH, SRL-L (TYP)
COAT EDGES AND
JOINTS WITH CRAFCO
SUPERFLEX ASPHALT
CEMENT (TYP)
BIT CONC SCRATCH LEVELING COURSE (AS DIRECTED)
AutoCAD SHX Text #22
AutoCAD SHX Text #3
AutoCAD SHX Text #24
AutoCAD SHX Text #26
AutoCAD SHX Text #7
AutoCAD SHX Text #23
AutoCAD SHX Text #28
AutoCAD SHX Text #30
AutoCAD SHX Text #9
AutoCAD SHX Text #11
AutoCAD SHX Text #32
AutoCAD SHX Text #13
AutoCAD SHX Text #15
AutoCAD SHX Text #36
AutoCAD SHX Text #38
AutoCAD SHX Text #40
AutoCAD SHX Text #42
AutoCAD SHX Text #17
AutoCAD SHX Text
TANYA DRIVE
AutoCAD SHX Text
MATCHLINE SEE SHEET C-201
AutoCAD SHX Text
MATCHLINE SEE SHEET C-201
AutoCAD SHX Text 2.00%
AutoCAD SHX Text 2.00%
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text
EXISTING ROLLED BITUMINOUS CURB (TYP BOTH SIDES)
AutoCAD SHX Text
EOP
AutoCAD SHX Text
EXISTING GRADE (TYP)
AutoCAD SHX Text
EOP
EXISTING GRADE (TYP)
DRAWING NUMBER
PROJECT NUMBER
DATE
CHECKED BY
DRAWN BYDRAWING TITLE & PROJECT NAMEREVISIONS
DESCRIPTIONDATENO.
OR
1-800-242-1776
CALL
PA ONE CALL
SYSTEM TOLL
FREE
THREE DAYS
BEFORE
YOU DIGKnow what's below.
Call before you dig.
SEALS
\\v er da nt as .c om \d fs \P ro je ct F ile s\
G A-
H Z\
H
AN
TW
P\
- 2
H an ov er
T w p G en er al E ng in ee rin g\
0-
C
D
BG
P av in g\
-C
AD
D
\S H
EE
T\
C -9
.d w g
- 5 /1
3/
:5
PM
R
SITE DETAILS
HANOVER TOWNSHIP
2025 COMMUNITY DEVELOPMENT BLOCK GRANT
PAVING PROJECT
HANOVER TOWNSHIP,LUZERNE COUNTY, PENNSYLVANIA
BMS
LSS
2025.08.11
31749
C-203
TYPICAL DETAIL FOR BIT CONC BASE COURSE REPLACEMENT
(WHERE DIRECTED)
NOT TO SCALE
VARIABLE WIDTH AS REQ'D. OR AS DIRECTED
4" COMPACTED DEPTH 25.0mm
BIT CONC BASE COURSE
* SAWCUT LATERAL AND LONGITUDINAL
EDGES FOR LIMITS OF BASE REPLACEMENT
SAWCUT
LONGITUDINAL EDGES *
COAT EDGES AND JOINTS WITH CRAFCO
SUPERFLEX ASPHALT CEMENT
BIT CONC WEARING AND/OR
BINDING COURSE(S)
UNDER SEPARATE PAYMENT
6" COMPACTED CRUSHED STONE
AGGREGATE SUBBASE (NO. 2A)
MANHOLE CASTING GRADE ADJUSTMENT
RISER REPLACEMENT DETAIL
(WHERE DIRECTED)
NOT TO SCALE
FINISHED GRADE EXIST MANHOLE
FRAME AND COVER
(SEE NOTES 2, 8 AND 9)
ADJUST TO GRADE AS REQUIRED WITH
PRECAST CONCRETE MANHOLE GRADE
ADJUSTMENT RINGS
EXIST PRECAST CONCRETE
CONICAL MANHOLE SECTION
OR BRICK MANHOLE (SEE NOTE 3)
MAX 1/4" BELOW
FINISHED GRADE
NOTES:
1. CONTRACTOR AND ENGINEER SHALL INSPECT EACH MANHOLE FOLLOWING THE
COMPLETION OF MILLING OPERATIONS TO DETERMINE WHICH MANHOLES REQUIRE
GRADE ADJUSTMENT RISER RECONSTRUCTION AND FRAME AND COVER CASTING
REPLACEMENT.
2. ONCE COMPLETELY UNCOVERED, MANHOLE FRAME AND COVER CASTING SHALL BE
REPLACED WHEN DETERMINED TO BE NECESSARY BY THE ENGINEER. EXISTING
FRAME AND COVER TO BE RETURNED TO OWNER.
3. FOR EXIST BRICK MANHOLES A MAXIMUM DEPTH OF 12" BELOW THE EXIST FRAME
CASTING IS REQUIRED TO BE RECONSTRUCTED WHEN DETERMINED TO BE
NECESSARY.
4. ALL NEW REPLACEMENT MANHOLE FRAME AND COVER CASTINGS SHALL GENERALLY
BE IN ACCORDANCE WITH PENNDOT ROADWAY CONSTRUCTION STANDARD RC-39M,
LATEST REVISION. LETTERING FOR STORM OR SANITARY BE PROVIDED DEPENDING
ON TYPE OF MANHOLE. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS PRIOR TO
ORDERING ANY REPLACEMENT FRAME AND COVER CASTINGS.
5. ALL PRECAST CONCRETE AND STEEL MANHOLE GRADE ADJUSTMENT RINGS SHALL BE
IN ACCORDANCE WITH PENNDOT ROADWAY CONSTRUCTION STANDARD RC-39M,
LATEST REVISION. STEEL GRADE ADJUSTMENT RINGS FOR FINAL ADJUSTMENT TO
FINISHED GRADE ARE SUBJECT TO THE APPROVAL OF THE ENGINEER. CONTRACTOR
SHALL PROVIDE SHOP DRAWINGS PRIOR TO ORDERING ANY PRECAST CONCRETE OR
STEEL GRADE ADJUSTMENT RINGS.
6. ONLY PRECAST CONCRETE GRADE ADJUSTMENT RINGS SHALL BE USED FOR
RECONSTRUCTION OF GRADE ADJUSTMENT RISER SECTION PRIOR TO FINAL GRADE
ADJUSTMENT OF ANY MANHOLE.
7. ALL MANHOLE CASTINGS REMOVED AND NOT SCHEDULED FOR RE-USE SHALL BE
RETURNED TO OWNER.
8. PROVIDE AND INSTALL REPLACEMENT MANHOLE FRAME AND COVER CASTING
ASSEMBLIES IN ACCORDANCE WITH COMMONWEALTH OF PENNSYLVANIA
DEPARTMENT OF TRANSPORTATION STANDARDS FOR ROADWAY CONSTRUCTION,
STANDARD DRAWING NUMBER RC-39M, LATEST REVISION.
9. PROVIDE PLATEN COVER PATTERN WITH SPECIFIED LETTERING FOR STORM
MANHOLES AND RIBBED COVER PATTER WITH SPECIFIED LETTERING FOR SANITARY
MANHOLES.
LOUIS S. SPACIANO
PROFESSIONAL
NO. PE080706
REGISTERED
ENGINEER
OVEREXCAVATION DETAIL
NOT TO SCALE
VA
R
IE
S
VA
R
IE
S
VARIES
* AS DIRECTED AND APPROVED BY THE ENGINEER
SEE DETAILS FOR
SURFACE RESTORATION
SUBGRADE
SELECT GRANULAR
MATERIAL - PENNDOT 2A
CRUSHED STONE AGGREGATE
R-3
(ROCK)
AGGREGATE
CLASS 4
TYPE B GEOTEXTILE
2'
WID
TH LENGTH
4'
3'
NOTES:
1. MAXIMUM DRAINAGE AREA = 1/2 ACRE.
2. INLET PROTECTION SHALL NOT BE REQUIRED FOR INLET TRIBUTARY TO SEDIMENT BASIN OR
TRAP. BERMS SHALL BE REQUIRED FOR ALL INSTALLATIONS.
3. ROLLED EARTHEN BERM SHALL BE MAINTAINED UNTIL ROADWAY IS STONED. ROAD SUBBASE
BERM ON ROADWAY SHALL BE MAINTAINED UNTIL ROADWAY IS PAVED. EARTHEN BERM IN
CHANNEL SHALL BE MAINTAINED UNTIL PERMANENT STABILIZATION IS COMPLETED OR
REMAIN PERMANENTLY.
4. AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS., A
MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF
50 LBS. FILTER BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO.
40 SIEVE.
5. INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF
EVENT. BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN
FLOW CAPACITY HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING OF THE
INLET. DAMAGED OR CLOGGED BAGS SHALL BE REPLACED. A SUPPLY SHALL BE MAINTAINED
ON SITE FOR REPLACEMENT OF BAGS. ALL NEEDED REPAIRS SHALL BE INITIATED
IMMEDIATELY AFTER THE INSPECTION. DISPOSE ACCUMULATED SEDIMENT AS WELL AS ALL
USED BAGS ACCORDING TO THE PLAN NOTES.
*DO NOT USE ON MAJOR PAVED ROADWAYS WHERE PONDING MAY CAUSE TRAFFIC HAZARDS.
STANDARD CONSTRUCTION DETAIL #4-16
FILTER BAG INLET PROTECTION - TYPE M INLET
NOT TO SCALE
INLET GRATE
1" REBAR FOR
BAG REMOVAL
FROM INLET
ELEVATION VIEW PLAN VIEW
2" X 2" X 3/4"
RUBBER BLOCK
EXPANSION
RESTRAINT
(1/4" NYLON ROPE)
ISOMETRIC VIEW
INSTALLATION DETAIL
STORM
INLET
FLOW
2 MIN
(TYP)
FLOW
EARTHEN BERM TO BE
STABILIZED WITH TEMPORARY
OR PERMANENT VEGETATION
BE
R
M
2 MIN:1 (TYP)
6" MIN HEIGHT
3:1 3:1
6"
6"
BITUMINOUS WEARING COURSE
MATERIAL TO MATCH SURFACE
RESTORATION DETAIL
REFER TO SURFACE
RESTORATION DETAIL
ASPHALT CONCRETE CURB DETAIL
NOT TO SCALE
CLEAN SURFACE AND
APPLY TACK COAT
SEAL GUTTERLINE WITH
PG 64-22
VA
R
IE
S
NOTES:
1. PLACEMENT OF CURB SHALL BE IN ACCORDANCE WITH PENNDOT PUBLICATION
408 SECTION 636.
2. ASPHALT CURB SHALL BE INSTALLED DURING WEARING COURSE INSTALLATION.
3. ONCE THE FINAL WEARING COURSE OF BITUMINOUS PAVING IS PLACED THE
GUTTER LINE SHALL BE SEALED WITH PG 64-22 BY OVERLAPPING 3" ONTO THE
CURB AND THE EXTENDING 6" ONTO THE CARTWAY.
4. CONTRACTOR TO PROTECT AND MAINATIN EXISTING DRAINAGE STRUCTURES
DURING ASPHALT CONCRETE CURB REPLACEMENT.
5. MATCH EXISTING CURB REVEALS AT DRIVEWAY LOCATIONS
ASPHALT CONCRETE
CURB
AutoCAD SHX Text
EXISTING PAVEMENT STRUCTURE (VARIABLE THICKNESS)
MILLED PAVEMENT SURFACE
LOUIS S. SPACIANO
PROFESSIONAL
NO. PE080706
REGISTERED
ENGINEER DRAWING NUMBER
PROJECT NUMBER
DATE
CHECKED BY
DRAWN BYDRAWING TITLE & PROJECT NAMEREVISIONS
DESCRIPTIONDATENO.
OR
1-800-242-1776
CALL
PA ONE CALL
SYSTEM TOLL
FREE
THREE DAYS
BEFORE
YOU DIGKnow what's below.
Call before you dig.
SEALS
\\v er da nt as .c om \d fs \P ro je ct F ile s\
G A-
H Z\
H
AN
TW
P\
- 2
H an ov er
T w p G en er al E ng in ee rin g\
0-
C
D
BG
P av in g\
-C
AD
D
\S H
EE
T\
C -9
.d w g
- 5 /1
3/
:5
PM
R
MAINTENANCE AND PROTECTION OF TRAFFIC DETAILS
HANOVER TOWNSHIP
2025 COMMUNITY DEVELOPMENT BLOCK GRANT
PAVING PROJECT
HANOVER TOWNSHIP,LUZERNE COUNTY, PENNSYLVANIA
BMS
LSS
2025.08.11
31749
C-901
PATA 106
WORK IN SINGLE-LANE AND CENTER LINE - TWO FLAGGERS
(SHORT TERM)
NOT TO SCALE
| CS1-CS1 |
| Sheets and Views |
| CS1 |
| 2025 CBDG-C-201 |
| Sheets and Views |
| C-201 |
| 2025 CBDG-C-202 |
| Sheets and Views |
| C-202 |
| C-901-C-901 |
| Sheets and Views |
| C-901 |
| C-901-C-903 |
| Sheets and Views |
| C-903 |
File details come from the government source that posted it. Updated .