762.pdf

PDF 98 KB Posted

Attached to
Repair of NSN # 6130-01-308-6188
Solicitation number
FA825025Q0584
Issued by

About this file

The document is a Contract Repair Screening Analysis Worksheet for a power supply (NSN 6130013086188ZR, Part Number 101-9362) used in the AN/TYQ-23 (V5) weapon system. The worksheet indicates an annual repair quantity of 2 units, with the latest repair cost at $4,500 per unit and an annual repair budget of $9,000. The forecast unit price is $13,643, and the item does not currently have organic or DMISA repair capability. Two approved/potential sources are identified: J-Squared Technologies Inc. and Power Clinic Inc., both approved on 03 MAR 2025. The RMC/RMSC code is R2/C, valid until 04 MAY 2026. The government does not own the data or rights needed to contract repair from additional sources, and it has been determined uneconomical to purchase or reverse engineer the part data. Previous contract repair sources include Power Clinic Inc. and Pacific Electronic Enterprises Inc., with contracts awarded in 2019.

View the file

Other files

File Type Posted
FA825025Q0584_______0001.pdf PDF
PWS.pdf PDF
IUID.pdf PDF
GREEN.pdf PDF
QAIRQMT_REPORT.pdf PDF
ITMDESC_REPORT.pdf PDF
TRNSPDATA_REPORT.pdf PDF
SOW.pdf PDF
RDL_REPORT.pdf PDF
FA825025Q0584____DRAFT.pdf PDF
PKGRQMT_REPORT.pdf PDF
CAV_AF.pdf PDF
RQR_post_only.pdf PDF
CDRL.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET

PART I (To be completed by PMS Seller)

1. FORM INITIATION DATE

28 FEB 2025

2. FORM PRIORITY

3. NSN

6130013086188ZR

4. PART NUMBER

101-9362

5. PART NUMBER CAGE CODE

12868

6. NOUN

POWER SUPPLY

7. ANNUAL REPAIR

QUANTITY

8. LATEST REPAIR COST

$4,500.0000

9. ANNUAL REPAIR

BUDGET VALUE

$9,000.00

10. FORECAST UNIT

PRICE

$13,643.0000

11. ERRC

T

12. WEAPON SYSTEM

AN/TYQ-23 (V5)

13. END ITEM APPLICATION

14. HISTORY

DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)

HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?

IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)

NO X YES

SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE

POWER CLINIC INC 24 SEP 20191PAV4 FA825019P0166

PACIFIC ELECTRONIC ENTERPRISES INC 10 JAN 201932324 FA825019P0016

15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE

PART II (To be completed by Equipment Specialist)

16. TECHNICAL ORDERS REQUIRED NO X YES (annotate required data and availability on RDL) UNKNOWN

17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED X NO YES (annotate required data and availability on RDL) UNKNOWN

18. X THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR

ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)

19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE

SPECIAL FACILITIES ARE X NOT REQUIRED REQUIRED

GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE

20. EQUIPMENT SPECIALIST NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE

PART III (To be completed by Screening Technician if applicable)

21. REQUESTED ENGINEERING DATA

LISTED AND ANNOTATED ON RDL X NO DATA

22. SCREENING TECHNICIAN REMARKS

23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE

PART IV (To be completed by the Engineer)

24. CRITICAL SAFETY ITEM

X NO YES

25. CAN THIS ITEM BE COMMERCIALLY

OVERHAULED / REPAIRED (FAR Part 12)

NO X YES

26. PRECONTRACT QUALIFICATION

REQUIRED

NO X YES (JQR/QR, SQS, Waiver)

27. RDL REQUIRED FOR

SOLICITATION

NO X YES

28. RMC / RMSC CODE

R2 / C

29. RMC / RMSC EXPIRATION DATE

04 MAY 2026

30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY

The Government does not own the data or the rights to the data needed to contract repair of this part from additional sources. It has been determined to be uneconomical to buy the data or rights to the data. It is uneconomical to reverse engineer the part.

Market research is continuously being updated to improve competition.

31. APPROVED / POTENTIAL SOURCES

CAGE

CODE DATE APPROVED

J-Squared Technologies Inc. 7RP29 03 MAR 2025

POWER CLINIC INC. 1PAV4 03 MAR 2025

Page 1 of 2AFMC FORM 762, 20060201, V1 Version 5Generated by PRPS using Jasper Reports on 18 Mar 2025

CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET

32. ENGINEER NAME

Dam, Nghia T

CODE

N/A

OFFICE SYMBOL

415 SCMS / /GUEA

PHONE

801-864-8625

COMPLETION DATE

03 MAR 2025

PART V (Miscellaneous, if needed)

33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)

Page 2 of 2AFMC FORM 762, 20060201, V1 Version 5Generated by PRPS using Jasper Reports on 18 Mar 2025

File details come from the government source that posted it. Updated .