762 (9700).pdf
PDF 98 KB Posted
- Solicitation number
- FA825022Q0741
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IUID (9700).pdf | ||
| Item Description (654M2202-1).pdf | ||
| Requirements Data List (9700).pdf | ||
| Item Description (654M2252-1).pdf | ||
| PWS.docx | DOCX document | |
| FA825022Q0741.pdf | ||
| Transportation.pdf | ||
| IUID (0712).pdf | ||
| Packaging.pdf | ||
| Equiv Rates.xlsx | XLSX spreadsheet | |
| 762 (0712).pdf | ||
| SSJ.pdf | ||
| 807 (0712).pdf | ||
| GFP.xlsx | XLSX spreadsheet | |
| 807 (9700).pdf | ||
| Requirements Data List (0712).pdf | ||
| SOW.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART I (To be completed by PMS Seller)
1. FORM INITIATION DATE
19 APR 2022
2. FORM PRIORITY
3. NSN
5985015369700FD
4. PART NUMBER
654M2202-1
5. PART NUMBER CAGE CODE
25531
6. NOUN
HORN,WAVEGUIDE
7. ANNUAL REPAIR
QUANTITY
8. LATEST REPAIR COST
$4,040.8300
9. ANNUAL REPAIR
BUDGET VALUE
$4,040.83
10. FORECAST UNIT
PRICE
$9,600.0000
11. ERRC
T
12. WEAPON SYSTEM
AN/MST-T1A
13. END ITEM APPLICATION
Antenna Feed Assy
14. HISTORY
DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)
HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?
IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)
NO X YES
SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE
COBHAM EXETER INC. 30 AUG 202166544 FA825021P0072
SPACE MACHINE & ENGINEERING CORP. 21 SEP 202025531 FA825020P0070
15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART II (To be completed by Equipment Specialist)
16. TECHNICAL ORDERS REQUIRED X NO YES (annotate required data and availability on RDL) UNKNOWN
17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED NO X YES (annotate required data and availability on RDL) UNKNOWN
18. X THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR
ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)
19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS NOT REQUIRED X REQUIRED REQUIRED BUT NOT AVAILABLE
SPECIAL FACILITIES ARE NOT REQUIRED X REQUIRED
GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
20. EQUIPMENT SPECIALIST NAME
Mickey, Richard J
CODE OFFICE SYMBOL
415 SCMS / GUMAA
PHONE
801-777-7551
COMPLETION DATE
19 APR 2022
PART III (To be completed by Screening Technician if applicable)
21. REQUESTED ENGINEERING DATA
X LISTED AND ANNOTATED ON RDL NO DATA
22. SCREENING TECHNICIAN REMARKS
23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART IV (To be completed by the Engineer)
24. CRITICAL SAFETY ITEM
X NO YES
25. CAN THIS ITEM BE COMMERCIALLY
OVERHAULED / REPAIRED (FAR Part 12)
X NO YES
26. PRECONTRACT QUALIFICATION
REQUIRED
X NO YES (JQR/QR, SQS, Waiver)
27. RDL REQUIRED FOR
SOLICITATION
NO X YES
28. RMC / RMSC CODE
R1 / C
29. RMC / RMSC EXPIRATION DATE
06 APR 2027
30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
Cobham Exeter Inc 66544 06 APR 2022
32. ENGINEER NAME
Kincaid, James
CODE
N/A
OFFICE SYMBOL
415 SCMS / GUEA
PHONE
404-425-2433
COMPLETION DATE
19 APR 2022
Page 1 of 2AFMC FORM 762, 20060201, V1 Version 6Generated by PRPS using Jasper Reports on 20 Apr 2022
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART V (Miscellaneous, if needed)
33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)
USER TYPE: Production Management Specialist - Seller NAME: Nielsen, Becky A DATE: 29 MAY 2020
ORG / OFFICE SYMBOL: 415 SCMS / GUMAC COMMERCIAL PHONE: 801-586-5520 DSN PHONE: 586-5520
No previous contract or DIMSA repair
Page 2 of 2AFMC FORM 762, 20060201, V1 Version 6Generated by PRPS using Jasper Reports on 20 Apr 2022
File details come from the government source that posted it. Updated .