762-24-103_Final CD_Drawings.pdf
PDF 15 MB Posted
- Attached to
- Tucson CMOP Solar PV Parking Federal contract opportunity
- Solicitation number
- 36C77025R0011
About this file
The attached file is a comprehensive set of final construction documents for the Tucson VA CMOP Solar PV Parking project (VA Project Number 762-24-103). The documents detail the installation of covered parking solar photovoltaic (PV) systems across multiple canopy structures at the Tucson Veterans Affairs Center for Medication Outpatient Preparation (CMOP) facility located at 3675 E. Britannia Drive, Tucson, Arizona. The project includes base bid work for 6 canopies (Canopies 1, 2, 7, 8, 9, 10) and 4 optional add alternate canopies (Canopies 3, 4, 5, and 6), with solar panel installations, new lighting, electrical infrastructure, and telecommunications systems.
The construction documents include detailed architectural, structural, electrical, and telecommunications plans spanning 27 sheets, covering site demolition, foundation preparations, canopy layouts, electrical one-line diagrams, solar system configurations, and security camera placements. The project is designed as a Service-Disabled Veteran Owned Business (SDVOSB) set-aside with an estimated construction magnitude between $2M to $5M. The solar PV system will utilize multiple inverters and integrate with existing electrical infrastructure, with provisions for future expansion through the add alternate options. The design emphasizes comprehensive system integration, including electrical distribution, lighting controllers, and security surveillance systems compatible with existing VA campus infrastructure.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C77025R0011 Q-A.docx | DOCX document | |
| Tucson_CMOP_Geotech_South_Parking_Lot_Nov-2021.pdf | ||
| Tucson_CMOP_Geotech_South_Parking_Lot_Nov-2024.pdf | ||
| 762-24-103 Solar PV Site Map.pdf | ||
| 762-24-103 Solar PV Electrical Calcs.pdf | ||
| 36C77025R0011 0001.pdf | ||
| 762-24-103 Solar PV PreBid Site Visit 8-14-25.pdf | ||
| 762-24-103_Final CD_Specifications.pdf | ||
| 36C77025R0011.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
ELECTRICAL/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH COA NO. 20013-0
ELEC ENGR COA NO. 20013-0
/1
/2
:4 :1
A
M
COVER SHEET
JDM 01 OF 27AJS
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING SOLAR PV
SYSTEM
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
GI000
SPUR #: 2091.05
VA PROJECT NUMBER: 762-24-103
FINAL CONSTRUCTION DOCUMENTS
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
03 GI021 PHASING PLAN
[02] CIVIL
04 CS100 DEMOLITION PLAN
05 CS101 OVERALL SITE PLAN
06 CS102 SWPPP
07 CS200 DETAILS
08 CS201 DETAILS
[03] STRUCTURAL
09 S-000 GENERAL NOTES
10 SA011 SPECIAL INSPECTIONS
11 SS100 SITE REFERENCE PLAN
12 SB101 CANOPY FOUNDATION PLAN
13 SB102 CANOPY FOUNDATION PLAN
[04] ARCHITECTURAL
14 AS001 ARCHITECTURAL DEMOLITION AND NEW SITE PLAN
15 AS002 CANOPY LAYOUT
16 AS201 CANOPY ELEVATIONS AND DETAILS - SINGLE
17 AS202 CANOPY ELEVATIONS AND DETAILS - DOUBLE
[05] ELECTRICAL
18 E-001 ELECTRICAL LEGEND AND ABBREVIATIONS
19 ES001 ELECTRICAL SITE PLAN
20 ES002 ELECTRICAL CANOPY LIGHTING, SOLAR SYSTEM PLANS
21 E-601 ELECTRICAL ONE-LINE DIAGRAM
22 E-602 ELECTRICAL DETAILS AND SCHEDULES
23 E-603 ELECTRICAL DETAILS AND SCHEDULES
[06] TELECOM
24 T-001 TELECOMMUNICATIONS COVER SHEET
25 TS001 TELECOMMUNICATIONS SITE PLANS
26 TY501 SURVEILLANCE SYSTEM TELEVISION CAMERA DETAILS
27 TY601 ELETRONIC SECURITY SYSTEM RISERS
TOTAL SHEETS: 27
LOCATION
PLAN
AREA
PLAN
N N
PROJECT LOCATION
BASE BID AND BID ALTERNATE OPTIONS:
ADD ALT OPTION 1
REFER TO SHEETS AS001, AS121, E-602, AND ES-002 FOR FURTHER INFORMATION
1. CANOPY #3
A. ADD CANOPY #3 DESIGN SCOPE IN ITS ENTIRETY
ADD ALT OPTION 2
1. CANOPY #4
A. ADD CANOPY #4 DESIGN SCOPE IN ITS ENTIRETY
ADD ALT OPTION 3
1. CANOPY #5
A. ADD CANOPY #5 DESIGN SCOPE IN ITS ENTIRETY
ADD ALT OPTION 4
1. CANOPY #6
A. ADD CANOPY #6 DESIGN SCOPE IN ITS ENTIRETY
BASE BID
1. CONSTRUCT THE ENTIRE DESIGN SCOPE FOR CANOPY #1, CANOPY #2, CANOPY #7, CANOPY #8, CANOPY #9, AND CANOPY #10
2. PROVIDE NEW PAINT FOR EXISTING CANOPY AND COVERED SEATING TO MATCH EXISTING CANOPY
COLOR.
NUMBER REVISION DESCRIPTION DATE
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
3' -0
3' -2
4' -0
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
3' -0
WALL
WALL
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPER GUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS. REFERENCE RELEVANT ADDENDA FOR EACH OF THE ADOPTED CODES AND STANDARDS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2024 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2024 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2024 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2024 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2023 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2024 INTERNATIONAL MECHANICAL CODE
• 2023 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2024 INTERNATIONAL PLUMBING CODE (IPC)
• 2022 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2022 ANSI ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
• 2022 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2023 STEEL CONSTRUCTION MANUAL (16TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2022 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2022 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
• 2024 PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL CONFIRM
ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE ENTIRE
DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY WORK,
TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY DISCREPANCIES TO
THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND
EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
5. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND REPAIR
ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
6. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED OR
REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE OWNER.
7. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY PROVIDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
8. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE AND
OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS, BUT
DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL DRAWINGS.
CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE OTHER SHEETS
AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION DOCUMENTS THAT REFLECT
WORK REQUIRED TO ACHIEVE A COMPLETE AND OPERATIONAL GOAL. LACK OF
COORDINATION AND REVIEW OF DRAWINGS AND SPECIFICATIONS AS AN ENTIRE
DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS, BEING OBVIOUS AND
TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, SHALL
NOT BE IN ANY WAY AN ADDITIONAL COST TO THE GOVERNMENT.
9. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH SERVICES
TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN ADVANCE OF
PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND
APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR INTERRUPTIONS OF ANY
SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60 CALENDAR DAYS PRIOR TO THE
DESIRED TIME AND SHALL BE PERFORMED AS DIRECTED BY THE COR. MAJOR
INTERRUPTIONS SHALL BE COORDINATED WITH OTHER MAJOR INTERRUPTIONS AND MAY
NOT BE SCHEDULED FOR ONE DISCIPLINE MORE THAN TWICE THROUGHOUT THE OVERALL
CONSTRUCTION SCHEDULE UNLESS REQUESTED IN WRITING AND APPROVED BY THE COR.
CONTRACTOR WILL BE ADVISED, IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH
OTHER DATE AND/OR TIME SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE
TO OPERATIONS OF THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE
MEDICAL CENTER MAY OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING
HOURS. SCHEDULE INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT
BE AN ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT
MAY AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
10. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING BUILDING MATERIALS
(ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE DESIGNED/SPECIFIED AS BUILDING
MATERIAL IN ANY OF THE CONSTRUCTION DOCUMENTS.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
CLEAN UTILITY
000A
150 SF
/1 A101
X0000
6"2' -1
0"
'-2
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BG BUMPER GUARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
C/C CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALKBOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CPT CARPET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPOXY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
QT QUARRY TILE
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
1' -6
6" MAX
7" - 9" 11" MIN
17" - 25"
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
R
RAF RESILIENT ATHLETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
SWC STAINLESS STEEL WALLCOVERING
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
V/C VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL-FACED ACOUSTICAL TILE
VP VENEERED PLASTER
VT VINYL TILE
V/V VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
TRUE
NORTH
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
M
IN
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
ELECTRICAL/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH COA NO. 20013-0
ELEC ENGR COA NO. 20013-0
/1
/2
:0
:4
A
M
GENERAL INFORMATION
ECO 02 OF 27AJS
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
GI001
SPUR #: 2091.05NUMBER REVISION DESCRIPTION DATE
E. BRITANNIA DRIVE
E
H E
M
IS
P H
E R
E L
O O
P
CMOP
PHASE II
E. DESERT WALK LN
PHASE III
PHASE I
INCLUDED IN
PHASE II
CANOPY 1 CANOPY 2
CANOPY 3 CANOPY 4
CANOPY 5
CANOPY 7
C A
N O
P Y
C A
N O
P Y
C A
N O
P Y
CANOPY 6 EX. CANOPY
PHASING LEGEND AND DESCRIPTIONS
PHASE I - CONSTRUCT WORK IN THIS AREA
PHASE II - CONSTRUCT WORK IN THIS AREA
PHASE III -CONSTRUCT WORK IN THIS AREA
1. CONTRACTOR TO SUBMIT COORDINATION DRAWINGS BEFORE CONSTRUCTION CAN START.
2. CONCTRACTOR TO VALIDATE CURRENT PHASING AND ANY PROPOSED ALTERNATIVES TO BE
PRESENTED AND APPROVED BY THE VA, PRIOR TO CONSTRUCTION.
3. CONTRACTOR TO COORDINATE AND CONFIRM ACTUAL ORDER OF PHASING WITH VA PRIOR TO
CONSTRUCTION.
4. ALL WORK FOR CANOPIES 1, 2, 5, & 6, INCLUDING RESTRIPING PARKING SPACES, TO BE PERFORMED
ONLY IF THE RESPECTIVE ADD ALTERNATES ARE ACCEPTED. REF. SHEET GI000
GENERAL PHASING NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
ELECTRICAL/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH COA NO. 20013-0
ELEC ENGR COA NO. 20013-0
/1
/2
:0
:2
A
M
PHASING PLAN
JDM 03 OF 27AJS
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
GI021
SPUR #: 2091.05
N
1" = 40'-0"
PHASING SITE PLAN1
E.
H
EM
IS
PH
ER
E
LO
O P
OM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
SS
WWW
W
W W W
W
SS
SS
IRIR
IR
IR
IR
IR
IR
S S
SS
S
S S
S S
S S
S S
S S
S S
S
SS
SS
SS
SS
SS
SS
S
SS
SS SS SS SS SS SS SS SS SS SS SS
FOUND BRASS CAP FLUSH
INTERSECTION OF
HEMISPHERE LOOP &
BRITANNIA DRIVE
0.53' EAST & 0.71' SOUTH
FOUND MONUMENT
CONSISTENT WITH
BK.58,PG.64,PCR
FOUND 1/2" REBAR
NO TAG
CALCULATED SWC OF LOT 11
(BK.52,PG.56,PCR)
SET PK NAIL
EL=2624.26'
178.49'(C)
W W
W W
W W W W W W W W W W W W W W W W W W W W W W W
W
WW
W
W
W
W W
W W
W
FH
EXIST WATER LINE
EXIST SANITARY SEWER
EXIST UNDERGROUND
COMM LINE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E
UGE
UGE
UGE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
EXIST UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST UNDERGROUND
ELEC CONDUIT
REMOVE
4'x4' EXISTING PERMEABLE
PAVEMENT AT
NEW COLUMN
FOUNDATIONS (TYP)
REMOVE EXISTING LIGHT
POLE AND CONCRETE
FOUNDATION
REMOVE STRIPING
EXISTING LIGHT
FIXTURES
TO REMAIN
PROTECT EXISTING
CANOPY TO REMAIN
REMOVE EXISTING
LIGHT POLE AND
CONCRETE
FOUNDATION
REMOVE EXISTING
LIGHT POLE AND
CONCRETE
FOUNDATIONUNBOLT AND ROTATE
EXISTING LIGHT
FIXTURE 180°, RE: ELEC
(EXISTING CONC
FOUNDATION TO
REMAIN)
UNBOLT AND ROTATE
EXISTING LIGHT
FIXTURE 180°, RE: ELEC
(EXISTING CONC
FOUNDATION TO
REMAIN)
UNBOLT AND ROTATE
EXISTING LIGHT
FIXTURE 180°, RE: ELEC
(EXISTING CONC
FOUNDATION TO
REMAIN)
REMOVE 4'x8.75'
EXISTING PERMEABLE
PAVEMENT, CONCRETE
CURB, AND SIDEWALK
AT NEW COLUMN
FOUNDATIONS (TYP)
(SAWCUT FULL DEPTH)
REMOVE 3'x3.25' EXISTING
ASPHALT PAVEMENT AND
ADJACENT CONCRETE CURB
AT NEW COLUMN
FOUNDATIONS (TYP)
(SAWCUT FULL DEPTH)
REMOVE 4'x4' EXISTING
ASPHALT PAVEMENT
AT NEW COLUMN
FOUNDATIONS
(SAWCUT FULL DEPTH)
(TYP)
CONTRACTOR TO FIELD VERIFY
LOCATION AND DEPTH OF EXIST
IRRIGATION LINE AND ADJUST AS NECESSARY
REMOVE EXISTING LIGHT POLE
AND CONC FOUNDATION
REMOVE 3'x3.25'
EXISTING ASPHALT
PAVEMENT AND
ADJACENT CONCRETE
CURB AT NEW COLUMN
FOUNDATIONS (TYP)
(SAWCUT FULL DEPTH)
REMOVE EXISTING
PERMEABLE PAVEMENT AT
PARKING STALL FOR
ELECTRICAL EQUIPMENT
RE: ELEC AND STRUC
REMOVE STRIPING
0 20' 40'
SCALE: 1" = 20'
ALAN LANE
LACKEY
71821
12/ 18/
EXPIRES ON 9/30/2026
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
EXP. 10/11/2025
MEP/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH REG. NO. 20013-0
MECH ENGR REG. NO. 20013-0
ELEC ENGR REG. NO. 20013-0
6/ 6/
:4
2:
P M
REFE
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
SPUR #: 2091.05NUMBER REVISION DESCRIPTION DATE
1. UTILITIES PRESENTED ON THESE DRAWINGS ARE SHOWN
BASED ON THE BEST AVAILABLE INFORMATION.
CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS IN THE
FIELD PRIOR TO COMMENCING CONSTRUCTION.
CONTRACTOR SHALL NOTIFY LOCAL UTILITY LOCATING
SERVICES AT LEAST 48 HOURS BEFORE PROCEEDING WITH
ANY EXCAVATION TO LOCATE PUBLIC UTILITIES.
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
PRIVATE UTILITIES PRIOR TO ANY EXCAVATION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO
EXISTING WATER, WASTEWATER, STORMWATER LINES, AND
TRAFFIC CONTROL DEVICES. DAMAGES SHALL BE REPAIRED
AT THE CONTRACTOR'S EXPENSE.
3. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES
DURING CONSTRUCTION AND ANY DRAINAGE FEATURE OR
STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE
RESTORED TO EXISTING CONDITIONS OR BETTER.
4. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO
PROTECT ROOT SYSTEMS OF SHRUBS, PLANTS, AND TREES
ALONG THE AREA OF EXCAVATION.
5. LIMITS OF DEMOLITION REQUIRED IS SHOWN IN SCHEMATIC
REPRESENTATION ONLY. LIMITS OF DEMOLITION TO BE
VERIFIED IN FIELD BY CONTRACTOR.
6. ALL REMOVAL LIMITS SHOWN ARE SCHEMATIC IN NATURE. IF
ADDITIONAL EXISTING SURFACE FEATURES ARE REMOVED TO
FACILITATE INSTALLATION OF CONCRETE PIERS THE
CONTRACTOR IS RESPONSIBLE FOR REPLACEMENT AT NO
COST TO THE GOVERNMENT.
7. ALL REMOVED/DEMOLISHED MATERIAL TO BE DISPOSED OF
OFF-SITE BY CONSTRUCTION CONTRACTOR.
8. FOR LIMITS OF SURFACE FEATURE REMOVAL, REMOVE ALL
SURFACE FEATURES INCLUDING BUT NOT LIMITED TO:
FOUNDATIONS, ASPHALT, CONCRETE, GRAVEL, BRICK
PAVERS, RETAINING WALL, PATIOS, RAMPS, STAIRS,
HANDRAILS, BOLLARDS, LIGHT POLES, ETC. CONTRACTOR
SHALL PROTECT UNDERGROUND UTILITIES, EXCEPT WHERE
SHOWN OTHERWISE.
9. REFER TO ARCHITECTURAL DRAWINGS FOR ALL NEW AND
FUTURE SIGNAGE FOR THE PROPERTY.
10. REFER TO ELECTRICAL DRAWINGS FOR ALL NEW AND FUTURE
SITE LIGHTING FIXTURE LOCATIONS AND DETAILS.
AREA NOT IN SCOPE
LEGEND
NOTES
DEMOLITION PLAN
CD100
DEMO LIMITS
PROPERTY LINE
BENCHMARK
PER PIMA COUNTY GEODETIC CONTROL HELD "G 11", ALUMINUM CAP IN
HAND-HOLE, IN THE MEDIAN OF PALO VERDE ROAD.
ELEVATION=2615.82' (NAVD88)
1 DEMOLITION PLAN
1" = 20'
EXISTING ELECTRICAL CONDUIT
TO BE UTILIZED FOR PV ELECTRICAL
LINES (RE: ELEC)
EXISTING LIGHT POLE
UGE
H
EM
IS
PH
ER
E
LO
O P
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
SS
WWW
W
W W W
W
SS
SS
SS
IRIR
IR
IR
IR
IR
IR
S S
S S
S S
S S
S S
S S
S S
SS
SS
SS
SS
SS
SS
SS
SS
S
SS
SS SS SS SS SS SS SS SS SS SS SS SS
S S
S S
S S
S S
S S
S S S
S
FOUND BRASS CAP FLUSH
INTERSECTION OF
HEMISPHERE LOOP &
BRITANNIA DRIVE
0.53' EAST & 0.71' SOUTH
FOUND MONUMENT
CONSISTENT WITH
BK.58,PG.64,PCR
FOUND 1/2" REBAR
NO TAG
CALCULATED SWC OF LOT 11
(BK.52,PG.56,PCR)
SET PK NAIL
EL=2624.26'
178.49'(C)
W
W W
W W
W W W W W W W W W W W W W W W W W W W W W W W
W
WW
W
W
W
W W
W W
W W
W
W
FH
EXIST WATER LINE
EXIST SANITARY SEWER
EXIST UNDERGROUND
COMM LINE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E
UGE
UGE
UGE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
EXIST UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST UNDERGROUND
ELEC CONDUIT
STRIPE OFF PARKING
SPACE FOR ELECTRICAL
EQUIPMENT MOUNTING
RACK, RE: ES002
27'
27'27'
18'27' 23'
27'27'
23' 28' 26'27'18'18' 27'
18' 27' 18'27'
27' 27' 18'
9'9'
9'9'
9'9'9'9'
9' 9' 9' 9'
9' 9'
9' 9'
18.2'
SEE INSET NO. 1
(THIS SHEET)
SEE INSET NO. 2
(THIS SHEET)
SEE INSET NO. 4
(THIS SHEET)
SEE INSET NO. 3
(THIS SHEET)
SEE INSET NO. 5
(THIS SHEET)
SEE INSET NO. 6
(THIS SHEET)
NEW STRIPING NEW STRIPING
NEW STRIPINGNEW STRIPING
NEW STRIPING
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 1)
(TYP)
CANOPY 1
(RE: ARCH & STR)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 5)
(TYP)
NEW ROTATED
LIGHT FIXTURE
NEW ROTATED
LIGHT FIXTURE
NEW ROTATED
LIGHT FIXTURE
CONTRACTOR
STAGING LOCATION
NEW CANOPY COLUMN
FOUNDATIONS (TYP)
CANOPY 3
(RE: ARCH & STR)
CANOPY 2
(RE: ARCH & STR) CANOPY 4
(RE: ARCH & STR)
CANOPY 5
(RE: ARCH & STR) CANOPY 6
(RE: ARCH & STR)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 5)
(TYP)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 4)
(TYP)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 6)
(TYP)NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 6)
(TYP)
CANOPY 7
(RE: ARCH & STR)
CANOPY 10
(RE: ARCH & STR)
CANOPY 9
(RE: ARCH & STR)
CANOPY 8
(RE: ARCH & STR)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 3)
(TYP)
NEW CANOPY
FOUNDATIONS
(SEE INSET NO. 2)
(TYP)
TCF=2624.95
TPE=±2625.45
TCF=2624.95
TPE=±2626.10
TCF=2625.63
FGE=±2626.50
TCF=2625.63
FGE=±2626.37
TCF=2625.63
FGE=±2626.28
TCF=2625.63
FGE=±2626.19
TCF=2625.63
FGE=±2626.06
TCF=2625.63
FGE=±2625.97
TCF=2625.63
FGE=±2625.88
TCF=2625.45
FGE=±2627.42
TCF=2625.45
FGE=±2626.39
TCF=2625.45
FGE=±2626.27
TCF=2625.45
FGE=±2626.16
TCF=2625.45
FGE=±2626.04
TCF=2625.45
FGE=±2625.97
TCF=2625.45
FGE=±2625.85
TCF=2625.45
FGE=±2625.70
TCF=2624.95
TPE=±2626.00
TCF=2624.95
TPE=±2625.90
TCF=2624.95
TPE=±2625.82
TCF=2624.95
TPE=±2625.76
TCF=2624.95
TPE=±2625.73
TCF=2624.95
TPE=±2625.57
TCF=2624.95
TPE=±2625.46
TCF=2624.95
TPE=±2625.46
TCF=2624.95
TPE=±2625.46
TCF=2624.95
TPE=±2625.46
TCF=2624.95
TPE=±2625.46
TCF=2625.33
TPE=±2626.40
TCF=2625.33
TPE=±2626.33
TCF=2625.33
TPE=±2626.08
TCF=2625.35
TPE=±2626.66TCF=2625.35
TPE=±2626.56
TCF=2625.35
TPE=±2626.44
TCF=2625.35
TPE=±2626.33
TCF=2625.35
TPE=±2626.10
TCF=2624.75
TPE=±2625.60
TCF=2624.75
TPE=±2625.50
TCF=2623.59
TPE=±2625.00
TCF=2623.59
TPE=±2624.64TCF=2623.59
TPE=±2624.40
TCF=2623.59
TPE=±2624.34
TCF=2624.05
TPE=±2625.65
TCF=2624.05
TPE=±2625.33
TCF=2624.05
TPE=±2625.12
TCF=2624.05
TPE=±2624.80
TCF=2623.56
TPE=±2624.80
TCF=2623.56
TPE=±2624.60
TCF=2623.56
TPE=±2624.48
TCF=2623.56
TPE=±2624.31
TCF=2625.63
FGE=±2626.13
UGE UGE
PROTECT EXIST CURB
AND GUTTER
(TYP)
NEW 30"
CONCRETE PIER
FOUNDATION
WITH CONCRETE
CLOSURE POUR
RE: STRUCTURAL
4'3'PROTECT 6" EXIST
CONC CURB &
GUTTER
NEW 4'X4' CONCRETE
CLOSURE POUR
( MATCH EXIST GRADE)
NEW 30" CONCRETE
PIER FOUNDATION
RE: STRUCTURAL
RE-STRIPE TO MATCH
EXISTING
4'
3'
NEW
4'X4' CONCRETE
CLOSURE POUR
(MATCH EXIST
GRADES)
NEW 30" CONCRETE
PIER FOUNDATION,
RE: STRUCTURAL
PROTECT EXIST
SIDEWALK,
BOLLARDS,
WHEELSTOPS
RE-STRIPE TO
MATCH EXISTING
UGE UGE UGE UGE UGE UGE
4'
5.
5'
NEW 5' CONC SIDEWALK
(MATCH EXIST GRADE)
NEW 4'X1.75'
CONCRETE CLOSURE
POUR
(MATCH EXIST GRADE)
NEW 30" CONCRETE
PIER FOUNDATION
RE: STRUCTURAL NEW 4 LF CONC
CURB & GUTTER
1.
3'
2.
0.
5'
NEW 3 LF CONC CURB
NEW 2.75'X3'
CONCRETE CLOSURE
POUR (MATCH EXIST
GRADE)
NEW 30"
CONCRETE
PIER
FOUNDATION
RE: STRUCTURAL
PROTECT EXIST
CONCRETE SIDEWALK
COM COM COM COM COM COM COM COM COM COM
2.
3'
NEW 3 LF CONCRETE
CURB
NEW 2.75'X3'
CONCRETE CLOSURE
POUR (MATCH EXIST
GRADE)
NEW 30" CONCRETE
PIER FOUNDATION
RE: STRUCTURAL
0 20' 40'
SCALE: 1" = 20'
ALAN LANE
LACKEY
71821
12/ 18/
EXPIRES ON 9/30/2026
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
EXP. 10/11/2025
MEP/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH REG. NO. 20013-0
MECH ENGR REG. NO. 20013-0
ELEC ENGR REG. NO. 20013-0
6/ 6/
:4
2:
P M
REFE
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
SPUR #: 2091.05NUMBER REVISION DESCRIPTION DATE
1. UTILITIES PRESENTED ON THESE DRAWINGS ARE SHOWN
BASED ON THE BEST AVAILABLE INFORMATION.
CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS IN THE
FIELD PRIOR TO COMMENCING CONSTRUCTION.
CONTRACTOR SHALL NOTIFY LOCAL UTILITY LOCATING
SERVICES AT LEAST 48 HOURS BEFORE PROCEEDING WITH
ANY EXCAVATION TO LOCATE PUBLIC UTILITIES.
CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
PRIVATE UTILITIES PRIOR TO ANY EXCAVATION.
2. ALL DIMENSIONS SHOWN ARE TO FACE OF CURB, UNLESS
OTHERWISE NOTED.
3. REFER TO ARCHITECTURAL DRAWINGS FOR ALL NEW AND
FUTURE SIGNAGE FOR THE PROPERTY.
4. REFER TO ELECTRICAL DRAWINGS FOR ALL NEW AND FUTURE
SITE LIGHTING FIXTURE LOCATIONS AND DETAILS.
5. ALL REMOVAL LIMITS SHOWN ARE SCHEMATIC IN NATURE. IF
ADDITIONAL EXISTING SURFACE FEATURES ARE REMOVED TO
FACILITATE INSTALLATION OF CONCRETE PIERS THE
CONTRACTOR IS RESPONSIBLE FOR REPLACEMENT AT NO
COST TO THE GOVERNMENT.
6. TOP OF CONCRETE FOUNDATION ELEVATIONS ARE BASED
OFF EXISTING PAVEMENT OR EXISTING FINISHED GRADE
ELEVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
ELEVATIONS PRIOR TO CONSTRUCTION AND NOTIFY
ENGINEER IF THERE ARE ANY DISCREPANCIES.
AREA NOT IN SCOPE
LEGEND
NEW PARKING CANOPY WITH
INTEGRATED PV SOLAR ARRAY
NEW CANOPY COLUMN
FOUNDATIONS
NOTES
OVERALL SITE PLAN
CS100
NEW 41
2" CONCRETE SIDEWALK
TEMPORARY CONSTRUCTION FENCE
PROPERTY LINE
BENCHMARK
PER PIMA COUNTY GEODETIC CONTROL HELD "G 11", ALUMINUM CAP IN
HAND-HOLE, IN THE MEDIAN OF PALO VERDE ROAD.
ELEVATION=2615.82' (NAVD88)
NEW CONCRETE CLOSURE POUR
NEW 6" CURB
1 OVERALL SITE PLAN
1" = 20'
INSET NO. 1: FOUNDATION AT MEDIAN
(TYPICAL) (SOUTH PARKING LOT)
(RE: DETAIL 1/SHEET CS201)
SCALE: 1" = 10'
INSET NO. 2: FOUNDATION IN PERMEABLE
PAVEMENT (TYPICAL) (SOUTH PARKING LOT)
(RE: DETAIL 2/SHEET CS201)
SCALE: 1" = 10'
INSET NO. 4: FOUNDATION IN ASPHALT
PAVING (TYPICAL) (NORTH PARKING LOT)
(RE: DETAIL 4/SHEET CS201)
SCALE: 1" = 10'
INSET NO. 3: FOUNDATION ADJACENT
TO CURB AND SIDEWALK IN PERMEABLE
PAVEMENT (TYPICAL) (SOUTH PARKING LOT)
(RE: DETAIL 3/SHEET CS201)
SCALE: 1" = 10'
INSET NO. 5: FOUNDATION ADJACENT
TO CURB & SIDEWALK IN ASPHALT
PAVEMENT (TYPICAL) (NORTH PARKING LOT)
(RE: DETAIL 5/SHEET CS201)
SCALE: 1" = 10'
INSET NO. 6: FOUNDATION ADJACENT
TO CURB IN ASPHALT PAVEMENT (TYPICAL)
(NORTH PARKING LOT)
(RE: DETAIL 6/SHEET CS201)
SCALE: 1" = 10'
9'
TYP 9'
TYP
9'
TYP
9'
TYP
9'
TYP
CS201
CS201
CS201
CS201
CS201
TOP OF CONCRETE FOUNDATIONTCF
TOP OF EXISTING PAVEMENTTPE
EXISTING FINISHED GRADEFGE
CS201
H
EM
IS
PH
ER
E
LO
O P
COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM
SS
WWW
W
W W W
W W
SS
SS
SS
IRIR
IR
IR
IR
IR
IR
SS
SS
S S
S S
S S
S S
S S
S S
SS
SS
SS
SS
SS
SS
SS
S
SS
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
S S
S S
S S
S S
S S
SS
S
S
FOUND BRASS CAP FLUSH
INTERSECTION OF
HEMISPHERE LOOP &
BRITANNIA DRIVE
0.53' EAST & 0.71' SOUTH
FOUND MONUMENT
CONSISTENT WITH
BK.58,PG.64,PCR
FOUND 1/2" REBAR
NO TAG
CALCULATED SWC OF LOT 11
(BK.52,PG.56,PCR)FOUND 1/2" REBAR
NO TAG
SET PK NAIL
EL=2624.26'
178.49'(C)
W
W W
W W
W W W W W W W W W W W W W W W W W W W W W W W
W
WW
W
W
W
W W
W W
W W
W
W
FH
EXIST WATER LINE
EXIST SANITARY SEWER
EXIST UNDERGROUND
COMM LINE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E U
G E
U G
E
UGE
UGE
UGE
UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
EXIST UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST
UNDERGROUND
ELEC CONDUIT
EXIST UNDERGROUND
ELEC CONDUIT
IPB IPB IPB IPB
IPB
0 20' 40'
SCALE: 1" = 20'
ALAN LANE
LACKEY
71821
12/ 18/
EXPIRES ON 9/30/2026
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
EXP. 10/11/2025
MEP/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH REG. NO. 20013-0
MECH ENGR REG. NO. 20013-0
ELEC ENGR REG. NO. 20013-0
6/ 6/
:4
2:
P M
REFE
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
SPUR #: 2091.05NUMBER REVISION DESCRIPTION DATE
LEGEND
NOTES
STORM WATER POLLUTION
PREVENTION PLAN
CS102
1. IN AREAS WHERE THE PROJECT DESIGN
INCORPORATE FILL ADJACENT TO NEIGHBORING
LANDOWNERS, THE CONTRACTOR SHALL
IMPLEMENT GRADING AND/OR PERIMETER RUNOFF
CATCHMENT DEVICES (E.G. PERIMETER DITCHES)
DURING CONSTRUCTION TO ENSURE THAT THE
ADJACENT PARCELS BORDERING THE PROJECT
SITE DO NOT EXPERIENCE INTERIM DRAINAGE
FLOWS THAT EXCEED PRE-DEVELOPMENT
CONDITIONS FOR STORM EVENTS UP TO AND
INCLUDING THE CURRENT STORM DRAINAGE
DESIGN CRITERIA AT THE TIME OF PERMIT OR
CARRY SEDIMENT GENERATED AS PART OF
CONSTRUCTION ACTIVITIES. WHERE APPLICABLE,
THESE PRACTICES ARE IN ADDITION TO THE
STANDARD STORM WATER POLLUTION PREVENTION
DESIGN AND SHALL INCLUDE ADDITIONAL DITCHES
REDIRECTING SITE DRAINAGE OR TEMPORARY
PIPING.
2. ALL SUBCONTRACTORS WILL BE EDUCATED TO
FOLLOW STORM WATER POLLUTION PREVENTION
REQUIREMENTS.
3. ANY LAND CLEARING, CONSTRUCTION,
DEVELOPMENT, OR OTHER ACTIVITIES INVOLVING
THE MOVEMENT OF EARTH SHALL BE IN
ACCORDANCE WITH THE SWPPP.
4. A SITE OPERATOR SHALL BE ON SITE ON ALL DAYS
WHERE CONSTRUCTION OR GRADING ACTIVITY
TAKES PLACE.
5. STRUCTURAL BMP's WILL BE INSPECTED AND
MAINTAINED AT LEAST EVERY 14 DAYS AND AFTER
ANY PRECIPITATION OR RUNOFF EVENT THAT
CAUSES SURFACE EROSION, SEDIMENT TRANSPORT
OR VEHICULAR TRACKING.
6. SCRAPING AND SWEEPING OF STREETS, SIDEWALKS
AND FLOWLINES MUST BE CONDUCTED AT THE END
OF EACH WORK DAY WHEN DIRT AND OTHER
CONSTRUCTION MATERIAL HAS BEEN TRACKED
ONTO STREETS.
7. EARTH MATERIALS AND LANDSCAPE MATERIALS
SUCH AS SOD, ROCK AND MULCH SHALL NOT BE
STOCKPILED, PLACED OR STORED ON DRIVEWAYS,
STREETS, SIDEWALKS OR IN STORM WATER
FLOWLINES.
8. CONSTRUCTION SUPPLIES (e.g., TRUSSES AND
LUMBER), ROLL OFF CONTAINERS, DUMPSTERS,
PORTABLE TOILETS, TRAILERS, ETC., SHALL NOT BE
STORED ON STREETS OR SIDEWALKS OR OTHER
IMPERVIOUS SURFACES. THESE ITEMS SHALL BE
STORED ON THE CONSTRUCTION SITE OR STAGING
AREAS.
9. SANITARY FACILITIES SHALL BE LOCATED ON
NATURAL GROUND AND AT LEAST 25 FEET FROM ANY
STORM SEWER INLET OR WATER BODY AND SHALL
BE SERVICED REGULARLY AS NEEDED.
IPB
RFB
CWO
STC
INLET PROTECTION BARRIER
FILTER FABRIC FENCE
REINFORCED FABRIC BARRIER
CONCRETE WASHOUT AREA
STREET SWEEPING/CLEANING
CWO
STC STC
STC STC
BENCHMARK
PER PIMA COUNTY GEODETIC CONTROL HELD "G 11", ALUMINUM CAP IN
HAND-HOLE, IN THE MEDIAN OF PALO VERDE ROAD.
ELEVATION=2615.82' (NAVD88)
PROPERTY LINE
1 STORM WATER POLLUTION PREVENTION PLAN
1" = 20'
RFB
AREA NOT IN SCOPE
ALAN LANE
LACKEY
71821
12/ 18/
EXPIRES ON 9/30/2026
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
EXP. 10/11/2025
EXP. 10/11/2025
EXP. 10/11/2025
MEP/TELECOM ENGINEER
SPUR DESIGN
2519 MADISON AVE, STE 100
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, STE 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 � 4 � 6 � 8 �
1 2 � 4 � 6 � 8 �
STAMP:
DRAWING NUMBER
BUILDING NUMBER
CIVIL/STRUCTURAL ENGINEER
H2B
1225 N. LOOP WEST, STE 800
HOUSTON, TX 77008
(713) 864-2900
ARCH REG. NO. 20013-0
MECH ENGR REG. NO. 20013-0
ELEC ENGR REG. NO. 20013-0
6/ 6/
:4
2:
P M
REFE
FINAL CONSTRUCTION DOCUMENTS
INSTALL COVERED PARKING
SOLAR PV SYSTEM
12/18/2024
762-24-103
TUCSON VA CMOP
3675 E. BRITANNIA DRIVE
TUCSON, AZ 85706
SPUR #: 2091.05NUMBER REVISION DESCRIPTION DATE
DETAILS
CS200
PROP/EXIST
CONC CURB
PROP 3 4"
EXP JT
PROP S/W
PROP/EXIST
MATERIAL AS
SHOWN ON
PLANS
SEE TABLE FOR
REINFORCING
PROP
S/W
PROP 3 4" EXP
JT
PROP S/W
PROP/EXIST
BLDG SLAB
PROP
S/W
PROP/EXIST
PVMT
PROP 3 4"
EXP JT
1"R
TYP
FG (TYP)
MIN. 4" (100mm) THICK ASTM
NO. 57 STONE OPEN - GRADED BASE
MIN. 8" (200mm) THICK ASTM
NO. 2 STONE SUBBASE
GEOTEXTILE
BEDDING COURSE 11
2" TO 2"
(40 TO 50mm) THICK ASTM
NO. 8 OR NO. 89 AGGREGATE
CONCRETE PAVERS
MIN. 31
8" (80mm) THICK
26 GAUGE
PLASTIC TUBE
JOINT
SEAL
JOINT SEAL
4"R
4" DIA
PRE-MANUFACTURED
JOINT PLATE
NAIL
DOWEL DIA
PLUS 1
16"
CONST
JOINT
4" BOARD EXPANSION
JOINT FILLER
ASTM NO. 8 OR 9
AGGREGATE IN
OPENINGS
SOIL SUBGRADE SLOPED TOWARDS
EXIST PERFORATED DRAIN PIPE
AutoCAD SHX Text
SCALE :
AutoCAD SHX Text
CAD DETAIL NO.:
AutoCAD SHX Text
DATE ISSUED:
AutoCAD SHX Text
DETAIL TITLE /
AutoCAD SHX Text
PARKING STALL LAYOUT
AutoCAD SHX Text
SD321723-01.DWG
AutoCAD SHX Text
DECEMBER 2008
AutoCAD SHX Text
NONE
AutoCAD SHX Text
9' MIN.
AutoCAD SHX Text
9' MIN.
AutoCAD SHX Text 5'
AutoCAD SHX Text
8' MIN.
AutoCAD SHX Text
8' MIN.
AutoCAD SHX Text [2743mm]
AutoCAD SHX Text [2743mm]
AutoCAD SHX Text [2438mm]
AutoCAD SHX Text [2438mm]
AutoCAD SHX Text
1. 2. 3.
AutoCAD SHX Text
ACCESSIBILITY SIGNS
AutoCAD SHX Text
WALK
AutoCAD SHX Text 4" [102mm] PAINTED DIAGONAL LINES
AutoCAD SHX Text [1524mm]
AutoCAD SHX Text 5'
AutoCAD SHX Text [1524mm]
AutoCAD SHX Text 5'
AutoCAD SHX Text [1524mm]
AutoCAD SHX Text SEE SITE AND ENGINEERING DESIGN MANUAL FOR PARKING BAY WIDTHS. SEE VA BARRIER FREE DESIGN HANDBOOK H-08-13 FOR ACCESSIBLE SPACE QUANTITIES AND SIGNAGE. ACCESSIBLE SPACE FOR VANS MUST BE 11' [3300mm] WIDE WITH 5' [1524mm] ACCESS AISLES AND BE DESIGNATED FOR VANS ONLY.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
PARKING STALL LAYOUT
AutoCAD SHX Text
AutoCAD SHX Text
NTS
AutoCAD SHX Text
REGULAR SPACES
AutoCAD SHX Text
ACCESSIBLE SPACES
AutoCAD SHX Text
18' MIN.-20' MAX.
AutoCAD SHX Text [5486mm MIN.-6096mm MAX.]
AutoCAD SHX Text 1'
AutoCAD SHX Text [305mm]
AutoCAD SHX Text
COMBINATION CURB &
AutoCAD SHX Text
GUTTER/WHEEL STOP PER DETAIL 02577-2
AutoCAD SHX Text
ACCESSIBILITY SYMBOL
AutoCAD SHX Text 4" [102mm] PAINTED PARKING STALL LINES
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
3. ATTACH FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH.
AutoCAD SHX Text
4. BACKFILL AND COMPACT THE EXCAVATED SOIL.
AutoCAD SHX Text
3' MAX
AutoCAD SHX Text
(SEE NOTE 1)
AutoCAD SHX Text
18" MIN
AutoCAD SHX Text
(SEE NOTE 2)
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text %%uSECTION B-B%%U
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
SECTION B-B (ALTERNATE)
AutoCAD SHX Text 12"
AutoCAD SHX Text 4"
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
ALTERNATE V-TRENCH EXTENSION OF FABRIC INTO TRENCH
AutoCAD SHX Text NOTES: 1. 2 INCH THICK BY 2 INCH WOODEN STAKES TO BE SET AT MAX SPACING OF 3 FEET AND EMBEDDED A MIN OF 8 INCHES. IF PREASSEMBLED FENCE WITH SUPPORT NETTING IS USED, SPACING OF POST MAY BE INCREASED TO 8 FEET MAX. 2. ATTACH FILTER FABRIC TO WOODEN STAKES. FILTER FABRIC FENCE SHALL HAVE A MIN HEIGHT OF 18 INCHES AND MAX HEIGHT OF 36 INCHES ABOVE NATURAL GROUND. 3. WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHOULD BE OVERLAPPED 6 INCHES AT THE POSTS, AND FOLDED.
AutoCAD SHX Text %%uFILTER FABRIC FENCE DETAILS%%U
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
(36" MIN)
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
FLOW
AutoCAD SHX Text %%uPLAN%%U
AutoCAD SHX Text %%uSECTION A-A%%U
AutoCAD SHX Text
INLET PROTECTION BARRIER WITH REINFORCED FILTER FABRIC
AutoCAD SHX Text
INLET PROTECTION BARRIER WITH FILTER ROLLS
AutoCAD SHX Text NOTES: 1. FIBER ROLLS WILL BE UTILIZED ONLY WHEN SITE CONDITIONS DO NOT PERMIT THE USE OF FILTER FABRIC BARRIER, AND AS APPROVED BY THE ENGINEER.
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text L
AutoCAD SHX Text 1/3 L
AutoCAD SHX Text %%uPLAN%%U
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text %%uINLET PROTECTION BARRIER%%U
AutoCAD SHX Text
EXTENSION OF FABRIC INTO TRENCH
AutoCAD SHX Text
COMPACTED SOIL
AutoCAD SHX Text
WELDED WIRE
AutoCAD SHX Text
POST
AutoCAD SHX Text
WOOD OR METAL POST
AutoCAD SHX Text
WOOD OR METAL BEAM
AutoCAD SHX Text
FILTER FABRIC BARRIER
AutoCAD SHX Text
GRATE INLET
AutoCAD SHX Text
GRATE INLET
AutoCAD SHX Text
WOOD OR METAL BEAM
AutoCAD SHX Text
WOOD OR METAL POST
AutoCAD SHX Text FIBER ROLL STAKED OR WEIGHED DOWN w/ GRAVEL BAGS
AutoCAD SHX Text
COMPACTED SOIL TO PREVENT PIPING
AutoCAD SHX Text
STAKED FIBER ROLL
AutoCAD SHX Text
GRATE INLET
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text NOTES: 1. CONTRACTOR TO SECURE FILTER FABRIC TO GRATE. 2. INLET PROTECTION BARRIERS SHOULD BE PERODICALLY INSPECTED TO ENSURE POSITIVE DRAINAGE, AND SHOULD BE CLEANED/REPLACED AS NECESSARY.
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text %%uINLET PROTECTION BARRIER%%U
AutoCAD SHX Text
CONC PVMT
AutoCAD SHX Text
INLET GRATE
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
INLET FRAME
AutoCAD SHX Text
INLET WALL
AutoCAD SHX Text
SIDEWALK WIDTH (FT)
AutoCAD SHX Text
4 " CONCRETE SIDEWALK DETAIL12" CONCRETE SIDEWALK DETAIL
AutoCAD SHX Text
4.5 4.5 4.5
AutoCAD SHX Text 4'-0" 5'-0" 6'-0"
AutoCAD SHX Text 21 27 22
AutoCAD SHX Text 3 3 4
AutoCAD SHX Text 3 3 3
AutoCAD SHX Text 18 18 18
AutoCAD SHX Text
SIDEWALK THICKNESS (IN)
AutoCAD SHX Text
NUMBER OF BARS
AutoCAD SHX Text
LONGITUDINAL STEEL
AutoCAD SHX Text
#3 BARS
AutoCAD SHX Text
TRANSVERSE STEEL #3 BARS SPACING (IN)
AutoCAD SHX Text
SPACING (IN)
AutoCAD SHX Text
END BAR SPACING (IN)
AutoCAD SHX Text
ADJACENT TO CURB
AutoCAD SHX Text
THICKENED EDGE
AutoCAD SHX Text
ADJACENT TO PVMT
AutoCAD SHX Text
ADJACENT TO BLDG
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
THICKENED EDGE WHERE SHOWN ON PLANS
AutoCAD SHX Text
PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 4"
AutoCAD SHX Text
4 " THICK CONC12" THICK CONC
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
SIDEWALK WIDTH
AutoCAD SHX Text
(SEE PLANS)
AutoCAD SHX Text
2" COMPACTED SAND BED
AutoCAD SHX Text
SEE PLANS FOR HEIGHT
AutoCAD SHX Text NOTES: 1. STEEL TO MEET ASTM STANDARD STEEL TO MEET ASTM STANDARD SPECIFICATIONS FOR CONCRETE REINFORCING BARS. 2. EXPANSION JOINT TO BE PLACED AT EXPANSION JOINT TO BE PLACED AT THE END OF EACH CURB RADIUS AND SPACED AT A MAXIMUM DISTANCE OF 36-FEET. MAXIMUM SPACING FOR CONTROL JOINT SHALL BE 5 FEET.
AutoCAD SHX Text
SMOOTH BAR
AutoCAD SHX Text
SIDEWALK JOINT DETAILS
AutoCAD SHX Text
T = THICKNESS R = RADIUS
AutoCAD SHX Text %%uPLAN - JOINT PLATE%%U
AutoCAD SHX Text %%uSECTION - JOINT PLATE%%U
AutoCAD SHX Text 14"
AutoCAD SHX Text
EXIST
AutoCAD SHX Text
EXIST
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
DOWEL TYPE EXPANSION JOINT
AutoCAD SHX Text
CONNECTION S/W TO S/W
AutoCAD SHX Text
CONNECTION S/W TO DRIVEWAY
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
* #4 DEFORMED BAR EMBEDDED #4 DEFORMED BAR EMBEDDED IN EXIST CONC WITH EPOXY. IN EXIST CONC WITH EPOXY. ** SAWCUT 2-INCH MINIMUM. SAWCUT 2-INCH MINIMUM. MATCH D/W THICKNESS.MATCH D/W THICKNESS.
AutoCAD SHX Text T
AutoCAD SHX Text T/2
AutoCAD SHX Text T/2
AutoCAD SHX Text 1 "14"
AutoCAD SHX Text 2 "12"
AutoCAD SHX Text 38"
AutoCAD SHX Text 14"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 316"
AutoCAD SHX Text 2"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 12"
AutoCAD SHX Text 12"
AutoCAD SHX Text
PROP
AutoCAD SHX Text
PROP
AutoCAD SHX Text 14"R
AutoCAD SHX Text
NAIL
AutoCAD SHX Text
34" BOARD EXPANSION JOINT…
This is the start of the file's text. The full file is on GovTribe.