751-21070.RLO_Young SP Solar_IFB_DRAWINGS_8-06-25.pdf
PDF 4 MB Posted
- Solicitation number
- RFQ-171-250000000592-2
- Issued by
- Cass County, Michigan
About this file
These construction plans detail the Solar Array Installation project for Young State Park's Spruce Campground, commissioned by the Michigan Department of Technology, Management and Budget (DTMB) and located in Boyne City, Charlevoix County. The project involves installing a solar power system, including solar modules from Jinko Solar (JKM430M-54HL4-B), SolarEdge Technologies inverters (SE6000H-US Wave), and DC optimizers, with mounting on an existing metal standing seam roof. The project documents are marked for 50% review on 6/13/2025, 90% review on 6/27/2025, and bid set release on 7/31/2025, indicating a structured design and procurement timeline.
The electrical plans specify technical details such as using IronRidge rail and L-foot mounting systems, cellular connectivity for the inverter to enable owner tracking, and integration with the existing electrical panel "RP-W". The solar array will include provisions for owner training and mobile device monitoring. The project appears to be funded through state facilities administration and designed to enhance the park's infrastructure with renewable energy capabilities. Electrical specifications, symbols, and mounting details are comprehensively documented across multiple sheets, providing clear guidance for potential contractors and ensuring precise implementation of the solar installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SW
S
KA
R
KA
R
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
-0
1/
0.
G
AG --
R
EV
IE
W
D
AT
E
YO
U
N G
S
TA
TE
P
AR
K
S
PR
U C
E C
AM
PG
R O
U N
D
SO
LA
R
A R
R
AY
IN
ST
AL
LA
TI
O
N
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
R
EV
IE
W 6/
/2
Key Map
N
R
EV
IE
W
7/
/2
TI
TL
E
SH
EE
T
T
VICINITY MAP
LOCATION MAP
3 WORKING DAYS
BEFORE YOU DIG
CALL MISS DIG
1-(800)-482-7171
For free location of public utility lines
R
OR R
Know what's below.
Call before you dig.
SHEET INDEX
TITLENO.
SHEET
Site
N
Civil Engineer
BOYNE CITY
CHARLEVOIX COUNTY, MICHIGAN
YOUNG STATE PARK
SPRUCE CAMPGROUND
SOLAR ARRAY INSTALLATION
CONSTRUCTION PLANS FOR
MICHIGAN DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
TOWN 6 NORTH , RANGE 9 EAST
BOYNE CITY, CHARLEVOIX COUNTY, MICHIGAN
FILE NO.: 751/21070.RLO
E101 ELECTRICAL SPECIFICATIONS
T TITLE SHEET
E100 ELECTRICAL SYMBOLS, NOTES & ABBREVIATIONS
PROJECT PERMITS
E500 ELECTRICAL FLOOR PLAN - NEW
E501 ELECTRICAL ROOF PLAN - NEW
E600 ELECTRICAL RISER DIAGRAM & PANEL SCHEDULE
Electrical Engineer
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text Civil Engineers Land Surveyors Land Planners
AutoCAD SHX Text 46777 Woodward Avenue Pontiac, MI 48342-5032 Tel. (248) 332-7931 Fax. (248) 332-8257
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
NFE PROJECT NO. M477
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
NF
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text
PARK DR.
AutoCAD SHX Text
TERRACE CAMPGROUND
AutoCAD SHX Text
OAK CAMPGROUND
AutoCAD SHX Text
SPRUCE CAMPGROUND
AutoCAD SHX Text
SOUTH TOILER/SHOWER BUILDING
AutoCAD SHX Text
NORTH TOILER/SHOWER BUILDING
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text S
AutoCAD SHX Text
NF
AutoCAD SHX Text
ENGINEERS
AutoCAD SHX Text
LAKE SHORE RD
AutoCAD SHX Text
ADVANCE RD
AutoCAD SHX Text
BOYNE CITY-CHARLEVOIX RD
AutoCAD SHX Text
FRONT ST
AutoCAD SHX Text
STATE ST
AutoCAD SHX Text
BOYNE AVE
AutoCAD SHX Text
W MICHIGAN AVE
AutoCAD SHX Text
LAKE CHARLEVOIX
AutoCAD SHX Text DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS (DLARA) A PERMIT FROM DLARA IS REQUIRED FOR ALL PROPOSED ELECTRICAL IMPROVEMENTS. THE CONTRACTOR SHALL APPLY FOR THE PERMIT AND PAY ALL FEES REQUIRED BY DLARA. PSC SHALL APPLY FOR AND PAY FEES ASSOCIATED WITH PLAN REVIEW.
kruiter Snapshot kruiter Snapshot kruiter Snapshot kruiter Typewritten Text 8/06/2025 kruiter Typewritten Text
ISSUED FOR BIDS
kruiter Snapshot
FCPS
V
M C
VI
AV
B
C
DC
M
B
KP
SSCP
CR
SS
AS
TS
G
NCC
M P
E
A L B1 B2
S
SRS
X
X
X
CB
EMERGENCY PUSH STATION
CODE BLUE STATION
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVE
GLASS BREAK
DS
DUPLEX RECEPTACLE
TEACHER STATION
ADMINISTRATION STATION
STUDENT STATION
CARD READER
CO CARBON MONOXIDE DETECTOR
H
DOCK LIGHT FIXTURE
CONTROL MODULE
S
TELEPHONE / DATA OUTLET
DUTY STATION
STAFF STATION
STAFF REGISTER STATION
DOME LIGHT
DUAL BED STATION
SINGLE BED STATION
BED / LIGHT INTERFACE
PENDENT INTERFACE
EMERGENCY PULL STATION
MASTER STATION
NURSE CALL CONTROLLER
NURSE CALL
ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
THREE PHASE MOTOR
BELL
AUDIO / VIDEO INPUT
VIDEO INPUT
WALL MOUNTED SPEAKER / CLOCK COMBO
WALL MOUNTED SPEAKERS
DUAL FACE CLOCK
CCTV CONTROL PANELCCTV
SECURITY SYSTEM CONTROL PANEL
KEY PAD
BEAM DETECTOR
MOTION DETECTOR
DOOR CONTACT
CAMERA
MONITOR MODULE
FIRE CONTROL POWER SUPPLY
VISUAL ONLY UNIT
ELECTRICAL SYMBOLS LEGEND
DH
V
S
C
M
I
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SINGLE FACE CLOCK
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
MECHANICAL
ELECTRIC WATER HEATER
ELECTRIC UNIT HEATER
PIPE TRACE HEATER
RESISTANCE HEATER, KW SHOWN
SINGLE PHASE MOTOR
SOUND and SIGNAL
INTERCOM OUTLET
MICROPHONE OUTLET
TELEVISION OUTLET
CHIME
BUZZER
VOLUME CONTROL
SPEAKER
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER
MAGNETIC STARTER
FUSED DISCONNECT SWITCH
TRANSFORMER
CONTROL
xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
FIRE ALARM
TAMPER SWITCH (furnished by FP/C) FLOW SWITCH (furnished by FP/C)
FIREFIGHTER COMMUNICATION JACK
MAGNETIC DOOR HOLDER
REMOTE INDICATING LIGHT, CLG. MTD.
REMOTE INDICATING LIGHT, WALL MTD.
END OF LINE DEVICE
ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
PULL STATION
SPEAKER & LIGHT
SPEAKER
HORN
DUCT SMOKE DETECTOR
HEAT DETECTOR
SMOKE DETECTOR
HORN & LIGHT
DESIGNATIONS
(by E.C.)
(by others)
TT
FACP
ANN
EOL
G
WW
PC
CT
TS
T
H
TC
IC
F
FC
F
T
1,3
OR
PM
WM
BD
UFD
B
F S
J
J
D
WH
PP
J
SWITCH STYLE OCCUPANCY SENSOROC
DIGITAL TIME SWITCH
POWER PACK
DUAL TECHNOLOGY SENSOR - 360° - 500 SQ FT
DUAL TECHNOLOGY SENSOR - 360° - 1000 SQ FT
ULTRASONIC SENSOR - 360° - 2 CIRCUIT
OCCUPANCY SENSOR / PHOTOCELL
WALL MOUNT DUAL TECHNOLOGY SENSOR
OS5
OS4
T
OS2
OS3
OS1
PP
DUCT SMOKE DETECTORF/S
CEILING MOUNTED WIFI
DIGITAL EQUIPMENT METER, AS REQUIRED
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERRUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST./EX.
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERRUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
1. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SEALED TO MAINTAIN ORIGINAL
RATING.
2. ALL CONDUITS TO BE FIELD ROUTED ALONG EXISTING PIPING AND STRUCTURAL
STEEL.
3. THE DIVISION 26 CONTRACTORS SHALL VISIT THE PROJECT AND DETERMINE THE
EXACT EXTENT OF THE DEMOLITION WORK REQUIRED BEFORE BIDDING THE PROJECT.
4. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND UNUSED EQUIPMENT
WHERE WORK IS BEING DONE EXCEPT ITEMS NOTED OTHERWISE.
5. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF OLD WORK,
SURFACES SHALL BE PATCHED TO MATCH ADJACENT.
6. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL REMAIN
CONCEALED AND DOES NOT INTERFERE WITH ANY NEW WORK OF ANY TRADE NEED
NOT BE REMOVED. HOWEVER, ALL CONDUIT SHALL BE CAPPED BELOW FINISH
SURFACE AND THEN PATCHED TO MATCH, OR AS NOTED.
7. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE MODIFIED OR ENLARGED
TO SUIT THE NEW SYSTEMS AS REQUIRED. PROVIDE ALL REQUIRED CUTTING AND
PATCHING.
8. IF ASBESTOS IS PRESENT, IT WILL BE REMOVED OR RENDERED HARMLESS UNDER
SEPARATE CONTRACT BY THE OWNER.
9. THE DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING
WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE MOUNTED
EQUIPMENT.
10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT VOLTAGES AND LOADS PRIOR TO
INSTALLING SERVICE TO EQUIPMENT.
11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND CASUAL FIELD
OBSERVATION. REPORT ANY DISCREPANCIES TO ENGINEER FOR CLARIFICATION.
GENERAL ELECTRICAL NOTES
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
BA
E
BA
E
TD
G
-2
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
2.
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C
H A
L L
R
A
N C
A R
B
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
R
EV
IE
W
6/
/2
YO
U
N G
S
TA
TE
P
AR
K
SP
R
U C
E C
AM
PG
R O
U N
D
SO
LA
R
A R
R
AY
IN
ST
AL
LA
TI
O
N
M A
T R
I X
JF
S
R
EV
IE
W
6/
/2
BI
D
S
ET
7/
/2
EL
EC
TR
IC
AL
SY
M
BO
LS
N
O
TE
S, A
BB
R
EV
E-kruiter Snapshot
EX PNL "RP-W"EX LIGHTING INVERTER NEW SOLAR
INVERTER
SOLAR METER
ELECTRICAL KEY NOTES
NO WORK SHALL BE DONE IN THIS AREA UNLESS NOTED OTHERWISE.1
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
BA
E
BA
E
TD
G
-2
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
2.
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C
H A
L L
R
A
N C
A R
B
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
R
EV
IE
W
6/
/2
YO
U
N G
S
TA
TE
P
AR
K
SP
R
U C
E C
AM
PG
R O
U N
D
SO
LA
R
A R
R
AY
IN
ST
AL
LA
TI
O
N
M A
T R
I X
JF
S
R
EV
IE
W
6/
/2
BI
D
S
ET
7/
/2
EL
EC
TR
IC
AL
FL
O
O R
P
LA
N N
EW
P
O W
ER
E-
N FLOOR PLAN - POWER
SCALE: 1/4" = 1'-0"
0 1 5 10
SOLAR MODULE
TYP.
GENERAL ELECTRICAL NOTES:
1. SOLAR MODULE LOCATIONS ARE NOT EXACT. REFER TO SOLAR
CONSULTANT DESIGN FOR EXACT LOCATION AND SIZING.
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
BA
E
BA
E
TD
G
-2
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
2.
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C
H A
L L
R
A
N C
A R
B
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
R
EV
IE
W
6/
/2
YO
U
N G
S
TA
TE
P
AR
K
SP
R
U C
E C
AM
PG
R O
U N
D
SO
LA
R
A R
R
AY
IN
ST
AL
LA
TI
O
N
M A
T R
I X
JF
S
R
EV
IE
W
6/
/2
BI
D
S
ET
7/
/2
EL
EC
TR
IC
AL
R O
O F
PL
AN
N
EW
P O
W
ER
E-
N
SCALE: 1/4" = 1'-0"
0 1 5 10
ROOF PLAN - POWER
EXISTING SERVICE
EXISTING
UTILITY
TRANSFORMER PANEL
EXISTING
RP-W
120/240V 1Ø,3W
100A MCB
ELECTRICAL RISER DIAGRAM - EXISTING
SCALE: N.T.S.
ELECTRICAL RISER DIAGRAM - NEW
SCALE: N.T.S.
EXISTING SERVICE
EXISTING
UTILITY
TRANSFORMER PANEL
EXISTING
RP-W
120/240V 1Ø,3W
100A MCB
M
NEW UTILITY
PROVIDED SOLAR
GENERATION METER
TO SOLAR MODULES
SOLAR INVERTER
AC
DC
SOLAREDGE TECHNOLOGIES INC.
SE6000H-US WAVE
AND CELLULAR PLUG IN
(3) #10
(1) #10 GND
3/4" CND
(3) #10
(1) #10 GND
3/4" CND
#10 MC4 CABLE
ELECTRICAL KEY NOTES
CONTRACTOR SHALL PROVIDE AND INSTALL JINKO SOLAR JKM430M-54HL4-B
SOLAR MODULES AND SOLAREDGE TECHNOLOGIES S500B DC OPTIMIZERS
OR APPROVED EQUAL.
CONTRACTOR SHALL PROVIDE AND INSTALL CELLULAR OPTION ON
INVERTER FOR OWNER TRACKING ON MOBILE DEVICE. COORDINATE WITH
OWNER AND PROVIDE OWNER TRAINING.
IRONRIDGE RAIL
S-5-U ASSEMBLY
IRONRIDGE L-FOOT
VARIES
(E) METAL STANDING SEAM ROOF
PV MODULE, BY OTHERS
IRONRIDGE RAIL
S-5-U CLAMP
IRONRIDGE L-FOOT
1 ROOF MOUNTING DETAIL
SCALE: N.T.S.
(E) METAL STANDING SEAM ROOF
PV MODULE, BY OTHERS
IRONRIDGE RAIL
S-5-U CLAMP
IRONRIDGE L-FOOT
(E) METAL STANDING SEAM ROOF
PV MODULE, BY OTHERS
IRONRIDGE RAIL
S-5-U CLAMP
IRONRIDGE L-FOOT
(E) METAL STANDING SEAM ROOF
PV MODULE, BY OTHERS
IRONRIDGE RAIL
S-5-U CLAMP
IRONRIDGE L-FOOT
30/25/2 1Ø 3W
FUSED
JC
/E
N G
B Y
PR
O
JE
C
T N
O
IN
D
EX
PC
A
D R
AW
N
B Y
D
ES
IG
N
ED
B
Y
R
EV
IE
W
D
AT
E
BA
E
BA
E
TD
G
-2
PR
O
JE
C
T D
ES
C
R
IP
TI
O
N
2.
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
R O
B E
R T
C
H A
L L
R
A
N C
A R
B
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
R
EV
IE
W
6/
/2
YO
U
N G
S
TA
TE
P
AR
K
SP
R
U C
E C
AM
PG
R O
U N
D
SO
LA
R
A R
R
AY
IN
ST
AL
LA
TI
O
N
M A
T R
I X
JF
S
R
EV
IE
W
6/
/2
BI
D
S
ET
7/
/2
EL
EC
TR
IC
AL
R
IS
ER
D
IA
G R
AM
A
N D
PA
N
EL
BO
AR
D
S C
H
ED
U
LE
S E-
| Sheets and Views |
| T-TITLE |