MIL-STD-2073.pdf
Military Standard PDF 11 MB Posted
- Attached to
- WINDOW WASHER ASSY
- Solicitation number
- 70ZU0127P21012B00
- Issued by
- Not on record
About this file
This is an informational guide published by the Defense Contract Management Agency (DCMA) in March 2014 providing comprehensive guidance on packaging and marking requirements for Department of Defense (DoD) contracts and solicitations.
The guide explains that packaging requirements in federal contracts are typically located in Section D (Packaging & Marking), with references to detailed specifications found in the Statement of Work, Military or Federal Specifications, aperture cards, drawings, and special packaging instructions. It details the five basic military preservation methods: Method 10 (physical protection), Method 20 (preservative coating only), Method 30 (waterproof protection), Method 40 (watervaporproof protection), and Method 50 (watervaporproof protection with desiccant). The guide distinguishes between Level A military packing (most severe worldwide conditions) and Level B (moderate conditions), along with minimal packing requirements for items not exposed to severe environments. For hazardous materials, contractors must comply with appropriate modal regulations including Title 49 CFR for land transport, IMO/IMDG for water, ICAO/IATA for commercial air, and AFMAN 24-204_IP for military air, with marking per MIL-STD-129. The document provides visual examples of eight specific packing methods (31-33, 41-45, 51-52) showing how items should be preserved, wrapped, cushioned, and contained at various protection levels.
The guide includes packaging requirement codes (PRC) established in MIL-STD-20731E(1), detailing two-digit codes for preservation methods, cleaning/drying procedures, preservative materials, wraps, cushioning materials, container types, and unit container levels. It covers quality assurance provisions including visual preservation examinations, leakage tests using multiple techniques, and heat-sealed seam testing. The guide specifies four basic marking types: identification markings (NSN, CAGE code, part number, quantity, contract number, preservation method, and gross weight); identification bar code markings; address markings using Military Shipping Labels with Transportation Control Numbers; and special markings for shelf-life, project codes, fragile items, Method 50 packaging, expedited handling, and hazardous materials. Additional requirements address heat-treated wood packaging material compliance, standard palletization per MIL-STD-147, passive RFID tag application per DFARS Clause 252.211-7006, and references to key specifications including MIL-STD-2073-1E for military packaging, ASTM D3951 for commercial packaging, and MIL-DTL-117 for heat-sealable bags.
View the file
Other versions and copies of MIL-STD-2073
| File | Revision | Posted | Attached to |
|---|---|---|---|
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | SWITCH, LIQUID LEVEL | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | GASKETS, FUEL FILTER, PARTS KIT, ENGINE FILTER AND SEAL PLAIN | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | WINDSHIELD WIPER BLADE | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | CONTROL-INDICATOR | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | STRAINER SEDIMENT | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | PUMP UNIT, CENTRIFUGAL | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | CONTROLLER, MOTOR | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | PASSAGE WAY FAN, EXHAUST | |
| MIL-STD-2073.pdf | Revision not stated | STRAINER SEDIMENT | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | GASKETS | |
| Mil-Std 2073.pdf | Revision not stated | COUPLING, FLEX, CONE RING | |
| Mil-Std 2073.pdf | Revision not stated | STRAINER, SEDIMENT | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | PUMP UNIT, CENTER WITH MOTOR | |
| Mil-Std 2073.pdf | Revision not stated | ODMS AIR CLEANER | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | GASKETS | |
| MIL-STD-2073.pdf | Revision not stated | Single Leg Wire Rope Assembly | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | TUBE, METALLIC | |
| MIL-STD-2073.pdf | Revision not stated | FILTER ELEMENT FLUID | |
| MIL-STD-2073.pdf | Revision not stated | EXHAUST FASTENER KIT | |
| MIL-STD-2073.pdf Same revision and size as this file | Revision not stated | ANODE SUPPORT |
Show all 20
Who attaches MIL-STD-2073
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .