The inventory is organized by building/location and specifies fire alarm panel types, quantity of detectors, horns/strobes, pull stations, sprinkler system presence, fire extinguishers (ABC and CO2 types), and other extinguishing systems. Key facilities documented include: Hanger (2 panels with 55 detectors, 30 horns/strobes, 12 pull stations, sprinkler system, and 17 ABC plus 5 CO2 extinguishers with a clean agent system in the AET shop); Supply (Honeywell panel with 1 detector, 4 horns/strobes, 4 pull stations, sprinkler system, 2 ABC extinguishers, and four ABC dry chemical Ansul systems); Admin (Honeywell panel with 17 detectors, 5 horns/strobes, 4 pull stations, no sprinkler, 6 ABC extinguishers); Pease Building (Siemens Fike panel with 46 detectors, 4 horns/strobes, 4 pull stations, sprinkler system, 13 ABC plus 1 CO2 extinguisher, and clean agent system in server room); Cutter Support Buildings 1 and 2; Exchange; Medical; Pease building storage garages; and MFPU. The document notes that the AFFF deluge system in the Hanger is locked out and no longer operational, with no work required for AFFF-related components. Total facility-wide inventory includes 192 detectors, 54 horns/strobes, 42 pull stations, 76 ABC extinguishers, 7 CO2 extinguishers, multiple Ansul systems, and clean agent systems in designated locations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hanger
Panel: 2 Simplex: 1, 4100ES, 1, 410U - one panel for fire detectors. One panel for AFFF deluge system. – AFFF deluge system has been lock out and no longer in operation.
Detectors: 55
Horns/ strobes: 30
Pull stations: 12
Sprinkler system: yes
Fire extinguisher: ABC: 17 CO2: 5
Other extinguishing systems: clean agent system in AET shop
Note: No work required for anything having to do with AFFF deluge system
Supply
Panel: Honeywell
Detectors: 1
Horns/ strobes: 4
Pull stations: 4
Sprinkler system: yes
Fire extinguisher: ABC: 2
Other extinguishing systems: Four ABC dry chemical Ansul systems
Admin
Panel: Honeywell
Detectors: 17
Horns/ strobes: 5
Pull stations: 4
Sprinkler system: no
Fire extinguisher: ABC: 6
Pease Building
Panel: Siemens Fike
Detectors: 46
Horns/ strobes: 4
Pull stations: 4
Sprinkler system: yes
Fire extinguisher: ABC: 13 CO2:1
Other extinguishing systems: clean agent system in server room
Cutter Support Building 1
Panel: Simplex 4010
Detectors: 9
Horns/ strobes:3
Pull stations:3
Sprinkler system: yes
Fire extinguisher: ABC: 4
Cutter Support Building 2
Panel: Edward System Technology
Detectors: 9
Horns/ strobes: 3
Pull stations: 3
Sprinkler system: yes
Fire extinguisher: ABC: 4
Exchange
Panel: Honeywell
Detectors: 23
Horns/ strobes: 2
Pull stations: 1
Sprinkler system: yes
Fire extinguisher: ABC: 4
Medical
Panel: Edward System Technology
Detectors: 30
Horns/ strobes: 4
Pull stations: 4
Sprinkler system: yes
Fire extinguisher: ABC: 5 CO2: 1
Pease building storage garages
Panel: Honeywell
Detectors: 7
Horns/ strobes: 1
Pull stations: 2
Sprinkler system: no
Fire extinguisher: ABC: 8
Other
Fire extinguisher: ABC: 19
MFPU
Panel: Unknown