U.S. Coast Guard Air Station Port Angeles Annual Fire Suppression & System Tests
Solicitation number
70Z0L3227Q20190002
Issued by
Not on record

About this file

This document is a facility fire safety equipment inventory listing that details the fire protection systems and equipment across multiple buildings and locations.

The inventory is organized by building/location and specifies fire alarm panel types, quantity of detectors, horns/strobes, pull stations, sprinkler system presence, fire extinguishers (ABC and CO2 types), and other extinguishing systems. Key facilities documented include: Hanger (2 panels with 55 detectors, 30 horns/strobes, 12 pull stations, sprinkler system, and 17 ABC plus 5 CO2 extinguishers with a clean agent system in the AET shop); Supply (Honeywell panel with 1 detector, 4 horns/strobes, 4 pull stations, sprinkler system, 2 ABC extinguishers, and four ABC dry chemical Ansul systems); Admin (Honeywell panel with 17 detectors, 5 horns/strobes, 4 pull stations, no sprinkler, 6 ABC extinguishers); Pease Building (Siemens Fike panel with 46 detectors, 4 horns/strobes, 4 pull stations, sprinkler system, 13 ABC plus 1 CO2 extinguisher, and clean agent system in server room); Cutter Support Buildings 1 and 2; Exchange; Medical; Pease building storage garages; and MFPU. The document notes that the AFFF deluge system in the Hanger is locked out and no longer operational, with no work required for AFFF-related components. Total facility-wide inventory includes 192 detectors, 54 horns/strobes, 42 pull stations, 76 ABC extinguishers, 7 CO2 extinguishers, multiple Ansul systems, and clean agent systems in designated locations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Hanger

Panel: 2 Simplex: 1, 4100ES, 1, 410U - one panel for fire detectors. One panel for AFFF deluge system. – AFFF deluge system has been lock out and no longer in operation.

Detectors: 55

Horns/ strobes: 30

Pull stations: 12

Sprinkler system: yes

Fire extinguisher: ABC: 17 CO2: 5

Other extinguishing systems: clean agent system in AET shop

Note: No work required for anything having to do with AFFF deluge system

Supply

Panel: Honeywell

Detectors: 1

Horns/ strobes: 4

Pull stations: 4

Sprinkler system: yes

Fire extinguisher: ABC: 2

Other extinguishing systems: Four ABC dry chemical Ansul systems

Admin

Panel: Honeywell

Detectors: 17

Horns/ strobes: 5

Pull stations: 4

Sprinkler system: no

Fire extinguisher: ABC: 6

Pease Building

Panel: Siemens Fike

Detectors: 46

Horns/ strobes: 4

Pull stations: 4

Sprinkler system: yes

Fire extinguisher: ABC: 13 CO2:1

Other extinguishing systems: clean agent system in server room

Cutter Support Building 1

Panel: Simplex 4010

Detectors: 9

Horns/ strobes:3

Pull stations:3

Sprinkler system: yes

Fire extinguisher: ABC: 4

Cutter Support Building 2

Panel: Edward System Technology

Detectors: 9

Horns/ strobes: 3

Pull stations: 3

Sprinkler system: yes

Fire extinguisher: ABC: 4

Exchange

Panel: Honeywell

Detectors: 23

Horns/ strobes: 2

Pull stations: 1

Sprinkler system: yes

Fire extinguisher: ABC: 4

Medical

Panel: Edward System Technology

Detectors: 30

Horns/ strobes: 4

Pull stations: 4

Sprinkler system: yes

Fire extinguisher: ABC: 5 CO2: 1

Pease building storage garages

Panel: Honeywell

Detectors: 7

Horns/ strobes: 1

Pull stations: 2

Sprinkler system: no

Fire extinguisher: ABC: 8

Other

Fire extinguisher: ABC: 19

MFPU

Panel: Unknown