Job specifications for deck covering/electrical matting renewal
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S_63410_ESD_0718_SWIT
SYY_NNN_63410_AUT_09-19_WLB204
WORK ITEM 1: Deck Covering, Electrical Matting, Renew
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to renew electrical matting as identified in Table 1.
TABLE 1 - DECKING SYSTEM PARTICULARS
| location |
| AREA |
| DECK |
MTL
| COVE BASE |
| system color |
| UNDERLAYMENt requirement |
| ET Shop, 02-66-0-C |
| 160 sq. ft |
| Steel |
| Matting provided by unit |
| - Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications. |
| Bridge, 03-56-0-C |
| 880 sq. ft |
| Steel |
| Matting provided by unit |
| - Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications. |
| IC and Gyro Room, 03-66-01-C |
| 130 sq. ft |
| Steel |
| Matting provided by unit |
| - Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications. |
1.2 Government-furnished property.
| Item description |
| NSN |
| quantity |
| estimated cost ($/unit) |
Blue Insulating Floor Matting
NSN: 7220-00-267-4630
530.18
2. REFERENCES
Coast Guard Drawings
Coast Guard Drawing 225-WLB_74_1, Rev B, STANDARD STRUCTURAL DETAIL BOOKLET Coast Guard Publications
Surface Forces Logistics Center Standard Specification 6341 (SFLC Std Spec 6341), 2014, Install Interior Deck Covering Systems
Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2014, Welding and Allied Processes
Other References
Federal Specification (Fed Spec) DDD-C-95, Mar 1972, Carpets and Rugs, Wool, Nylon, Acrylic, Modacrylic
3. REQUIREMENTS
3.1 General.
3.1.1 CIR. The Contractor shall submit a CIR for the inspections listed in the following paragraph(s):
None.
3.1.2 Tech Rep.
Not applicable
3.1.3 Protective measures. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces near the work area against contamination during the performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness.
3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).
3.2 Renewal. The Contractor shall perform all tasks specified in SFLC Std Spec 6341 and herein, to install a new covering system in the location(s) specified in Table 1.
NOTE
Insulation underlayment may be used to prevent condensation in certain areas - e.g., above ballast tanks and hot machinery spaces, especially where these decks form the deck tops of living spaces.
3.3 Visual inspection. Prior to priming deck surfaces, the Contractor shall perform a visual inspection of all exposed deck surfaces. Submit a CFR.
3.3 Ultrasonic thickness (UT) measurement. None required.
3.4 Deck covering color. Matting will be furnished by unit.
4. NOTES
4.1 Contractor to provide:
a. Seam vulcanizing compound
b. Matting adhesive
File details come from the government source that posted it.