Text version

S_63410_ESD_0718_SWIT

SYY_NNN_63410_AUT_09-19_WLB204

WORK ITEM 1: Deck Covering, Electrical Matting, Renew

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to renew electrical matting as identified in Table 1.

TABLE 1 - DECKING SYSTEM PARTICULARS

location
AREA
DECK

MTL

COVE BASE
system color
UNDERLAYMENt requirement
ET Shop, 02-66-0-C
160 sq. ft
Steel
Matting provided by unit
- Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications.
Bridge, 03-56-0-C
880 sq. ft
Steel
Matting provided by unit
- Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications.
IC and Gyro Room, 03-66-01-C
130 sq. ft
Steel
Matting provided by unit
- Remove existing electrostatic matting and dispose IAW local regulations. Renew up to 10% of existing underlayment. Install new electrostatic matting with vulcanized seals IAW technical specifications.

1.2 Government-furnished property.

Item description
NSN
quantity
estimated cost ($/unit)

Blue Insulating Floor Matting

NSN: 7220-00-267-4630

530.18

2. REFERENCES

Coast Guard Drawings

Coast Guard Drawing 225-WLB_74_1, Rev B, STANDARD STRUCTURAL DETAIL BOOKLET Coast Guard Publications

Surface Forces Logistics Center Standard Specification 6341 (SFLC Std Spec 6341), 2014, Install Interior Deck Covering Systems

Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2014, Welding and Allied Processes

Other References

Federal Specification (Fed Spec) DDD-C-95, Mar 1972, Carpets and Rugs, Wool, Nylon, Acrylic, Modacrylic

3. REQUIREMENTS

3.1 General.

3.1.1 CIR. The Contractor shall submit a CIR for the inspections listed in the following paragraph(s):

None.

3.1.2 Tech Rep.

Not applicable

3.1.3 Protective measures. The Contractor shall furnish and install all protective coverings to seal off and protect all non-affected vessel's components, equipment, and spaces near the work area against contamination during the performance of work. Upon completion of work, the Contractor shall remove all installed protective measures, inspect for the presence of contamination, and return all contaminated equipment, components, and spaces to original condition of cleanliness.

3.1.4 Interferences. The Contractor shall handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).

3.2 Renewal. The Contractor shall perform all tasks specified in SFLC Std Spec 6341 and herein, to install a new covering system in the location(s) specified in Table 1.

NOTE

Insulation underlayment may be used to prevent condensation in certain areas - e.g., above ballast tanks and hot machinery spaces, especially where these decks form the deck tops of living spaces.

3.3 Visual inspection. Prior to priming deck surfaces, the Contractor shall perform a visual inspection of all exposed deck surfaces. Submit a CFR.

3.3 Ultrasonic thickness (UT) measurement. None required.

3.4 Deck covering color. Matting will be furnished by unit.

4. NOTES

4.1 Contractor to provide:

a. Seam vulcanizing compound

b. Matting adhesive