Amendment_01.doc
DOC document 105 KB Posted
- Attached to
- CGC HEALY ASW Piping repairs
- Solicitation number
- 70Z085-18-Q-P45L5900
About this file
Amendment_01
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_02.doc | DOC document | |
| Synopsis-Solicitation_CGC_HEALY_ASW_PIPING.doc | DOC document | |
| SOW.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. CONTRACT ID CODE
PAGE OF PAGES
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
| 1 |
| 1 |
| 2. AMENDMENT/MODIFICATION NO. |
| 3. EFFECTIVE DATE |
| 4. REQUISITION/PURCHASE REQ. NO. |
| 5. PROJECT NO. (If applicable) |
| 0001 |
| 03 July 2018 |
| 6. ISSUED BY |
| CODE |
| N62474 |
| 7. ADMINISTERED BY (If other than Item 6) |
| CODE |
SKC Kristen Thomas
UNITED COAST GUARD
SURFACE FORCES LOGISTICS CENTER
1301 CLAY STREET, SUITE 800N
OAKLAND, CA 94612
| 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State, and ZIP Code) |
| (() |
| 9A. AMENDMENT OF SOLICITATION NO. |
70Z085-18-Q-P45L5900
| x |
| 9B. DATED (SEE ITEM 11) |
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
CODE
FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
( The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; of (c) By separate letter of telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
| (() |
| A. |
| THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE SOLICITATION NUMBER IN 8. |
x
| B. |
| THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b) |
| C. |
| THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF: |
| D. |
| OTHER (Specify type of modification and authority) |
E. IMPORTANT: Contractor ( is not; (x is required to sign this document and return 1 copy to the issuing office.
14. DECRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
1. This modification is to post questions and answers as follows:
Question: Does the T in the pictures provided reduce from 10 in on the main line to 8 in going into valve 44? Or is the pipe size on each of the 3 ends of the T 10 inches?
Answer: It is a 10” pipe leading down from the upper level into a 10” flange at ASW-V-51B. Bal-V-44 (8” flange) is then connected into this pipe with a section of 8” pipe saddle welded in. If it were to be renewed then the contractor would need to utilize a 10” tee fitting with a 8” bushing inserted on one of the 3 sides.
Question: Are both flanges the same?
Answer: Yes. Bal-V-44 is 8”. ASW-V-51B is 10”. 3rd outlet is 10” where it feeds up to the 3rd deck
Question: Is this 90/10 or 70/30 CuNi.
Answer: It appears to be 90/10 CuNi.
Question: From the part of the drawing I have, valve 51 B is downstream…install of a blank flange there would not solve the isolation issue. I’m sure there is a spot we can blank flange up stream, but I don’t have the full drawing.
Answer: it would definitely have to be flanged, it is directly next to the damaged area on the downstream side. We do have valves upstream which can also be flanged.
Question: Does a cofferdam need to be installed to accomplish the repairs on the ASW piping?
Answer: No
Question: Will the Coast Guard be handling all residual water from the draining system?
Answer: No
| 15A. NAME AND TITLE OF SIGNER (Type of print) |
| 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or Print) |
| 15B. CONTRACT/OFFEROR |
| 15C. DATE SIGNED |
| 16B. UNITED STATES OF AMERICA |
16C. DATE SIGNED
(Signature of person authorized to sign)
(Signature of Contracting Officer)
EXCEPTION TO SF 30
STANDARD FOEM 30 (Rev. 10-83)
APPROVED BY OIRM 11-84
Prescribed by GSA
FAR (48 CFR) 53.243
File details come from the government source that posted it.