SOW Hatch and Scuttle.doc
DOC document 66 KB Posted
- Attached to
- CGC FRANK DREW HATCH AND SCUTTLE
- Solicitation number
- 70Z08502541
About this file
This Statement of Work outlines requirements for watertight hatches and scuttles for the U.S. Coast Guard Cutter Frank Drew. The Coast Guard requires one 21-inch diameter quick-acting watertight flush scuttle (steel, 3-dog, forward hinge) and one 30" x 30" quick-acting watertight hatch (steel, raised 12-inch coaming with 21-inch quick-acting watertight scuttle), referencing Coast Guard Drawing 175-WLM-167-001.
Delivery is required within 40 weeks of award notice to CGC Frank Drew in Portsmouth, VA, with tracking information required within 48 hours of shipment. The equipment will be installed in two locations: a watertight hatch (P/N 3-42-0-Q 6) in the Machine Shop (location 1-50-1) and a watertight scuttle (P/N 3-15-0-E 7) in the Hydraulic Equipment Room (location 1-20-2). Questions should be directed to ENS Kevin Y. Colon, the Availability Project Manager. The period of performance is from July 25 to October 12, 2025, with a lead time of 20-30 weeks.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
U. S. COAST GUARD CUTTER FRANK DREW
WATERTIGHT HATCH AND SCUTTLE
Provide 01 21-inch Diameter Quick-Acting Watertight Flush Scuttle, Steel, 3-Dog, Fwd. Hinge. Also 01 30” x 30” Quick-Acting Watertight Hatch, Steel, Raised 12-inch coaming, with a 21 inch Quick-Acting Watertight Scuttle with reference from Coast Guard Drawing 175-WLM-167-001
Any questions regarding the Statement of Work must be directed to the Availability Project Manager, ENS Kevin Y. Colon at 757-628-4808. Email at Kevin.Y.Colon@uscg.mil Required supplies shall be delivered to the below address within 40 weeks of notice of award and tracking info must be supplied within 48 hours of each individual supply being shipped.
CGC FRAN DREW
4000 Coast Guard Blvd, Portsmouth, VA 23703 ATTN EMCS James Anderson, Cutter EPO/ CWO Michael Bacher, Port Engineer
Watertight Scuttle locations and descriptions
| Description |
| Location |
| P/N and Description |
| QTY |
Watertight Hatch
1-50-1 Machine Shop
3-42-0-Q Raised 30” x 30” WTH/QAS, 21” Dia; With 12” Coaming, Steel 01 Each
Watertight Scuttle 1-20-2 Hydraulic Equip Room
(3-15-0-E) Raised WTQAS, 21” Dia; With 12” Coaming, Steel 01 Each
File details come from the government source that posted it. Updated .