This document is an amendment containing questions and answers related to Solicitation Number 70Z08024QPBPL0026 for the USCGC MARGARET NORVELL DD FY24 REPAIRS. The solicitation seeks to procure repairs for the USCGC MARGARET NORVELL, including requirements for office space, duty section berthing, heavy lift equipment, hot-circulating water, storage facilities, and small boat storage. Key details include:

  • The office space is required to accommodate up to 10 personnel.
  • Duty section berthing is required per the solicitation.
  • No heavy lift equipment is specified in section 3.3.5.
  • Hot-circulating water is not required.
  • Dry stores and paint/flammable storage facilities will likely be required, but the ship will likely offload most items prior to sailing.
  • Small boat storage is required. The document also includes clarification requests regarding the required size/specifications of compressors/reefers and the Electronic Key Management System (EKMS) storage requirements.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Margaret Norvell (WPC-1105) FY24 DD Solicitation Number: 70Z08024QPBPL0026

Questions:002

1. How Many personnel will occupy the Office Space required by SECTION 3.3.1.?

-Up to 10

2. Will “Duty Section Berthing” be required per section 3.3.4?

-Yes

3. What is the capacity required by section 3.3.5 Heavy Lift Equipment?

-3.3.9 Marked No

4. Is Hot-circulating water required per 3.3.10.2?

-No

5. Will the storage facilities as outlined in 3.3.14.5 be required?

-Dry stores and Paint and Flammable marked Yes. Ship will likely offload most prior but will sail with some.

6. Will small boat storage be required per 3.3.15?

-Yes

WI 8 – Please provide quantity/size of compressor and reefer- No mention of reefer/compressor in Spec.

WI 8 refers to Bilge surface and piping. Clarification is needed.

WI 19 – Please provide details/specs of the requirement to provide an EKMS (Electronic Key Management System)- I will find out about the specifications of size and requirements of EKMS storage.