About this file
This document contains responses to questions regarding solicitation number 70Z080-23-Q-MECP0021 for dock-side repairs to the USCGC CAMPBELL in fiscal year 2024. The Coast Guard responded that honeycomb panels on the vessel can be replaced with Nomax Panels from Advanced Structures Corporation, Baker Sheet Metal panels, or any other product from Hexel Corporation. Additionally, further details for a duct run are available on drawing number 514032, rather than the drawing referenced in the question.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0001.pdf | ||
| Attachment 1 Schedule of Services.xls | XLS spreadsheet | |
| Attachment 2 Statement of Work_Specification.pdf | ||
| 70Z080-23-Q-MECP0021.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
70Z08023QMECP0021
CAMPBELL DOCKSIDE REPAIRS FY24
AMENDMENT 0001
Response to Questions/Requests for Clarification:
1. Question: In reviewing WI‐19, paragraph 3.3 Panel Installation, we have reviewed the noted drawings and have reached out to Hexel Corp for pricing on replacement panels. Hexel has informed us that they do not carry the HEXGARD I panel as noted in DWG 905 WMEC 621‐011 & DWG 905 WMEC 621‐006.
Does the USCG have any additional information on the Honeycomb panel? Below are the options that were given by Hexel Corp. Can the USCG give direction as to which product is currently being used on the USCGC
CAMPBELL or identify one of the products below that would be acceptable?
Answer: Any of the following can be used:
Baker Sheet Metal
Nomax Panels from Advanced structures Corporation