QUESTIONS / ISSUES and CLARIFICATIONS / ANSWERS
Solicitation: 70Z04419RN0007V00
Title: Repair of Rockwell Collins Power Amplifiers
DATE: August 9, 2019
Item Reference/Location Question / Issue Government Clarifications / Response
1 Past Performance
Questionnaire
Submittal /
Solicitation
Section D.1(2) –
Past Performance
Information Section
Is it possible to get a one week extension?
The Solicitation noted the point of contacts for the PPQ reference were due by August
5, 2019 and Attachment 6 noted the completed PPQ were due by 12pm on
August 23, 2019. Due to the discrepancy, the Solicitation has been revised to state the completed PPQs are due by 12pm on
August 23, 2019 and it is the Offeror’s responsibility to issue the PPQ form to the PPQ reference. The PPQ reference still needs to submit the completed form directly to the Government by August 23.
2 Statement of Work /
Section 3.1.3
Does test procedures need to be submitted for this item prior to award?
All potential Offeror’s are expected to follow the guidance within the Statement of
Work at this time.
3 Statement of
Work/Section 3.1.3
Clarification for submittal of test plan/procedures
The Statement of Work is updated to notate that the test plan/procedure is to be issued
“before or with the initial proposal, which is prior to the award”
4 Statement of Work /
Section 3.2.2.1
We would like to respectfully ask the USCG to consider an increase in the current repair
Turnaround Time of 10 days per unit to a revised - a not to exceed 30 day turnaround time.
The Equipment Repair Turnaround Time has been revised and increased from “Shall not exceed 10 days per unit once repair approval is authorized” to “Shall not exceed 20 days per unit once repair approval is authorized.”