Statement of Work 110 WPB Cradle Recert.docx
DOCX document 34 KB Posted
- Attached to
- 110’ WPB CRADLE AND SPREADER BAR RECERTIFICATION
- Solicitation number
- 70Z04026Q60746Y00
About this file
This is a Statement of Work for the recertification of a 110-foot USCG Cutter Cradle (CGY-C110-3) and Spreader Bar (CGY-S110-1). The contractor shall conduct all necessary inspections and certifications to verify that the docking cradle and spreader bar meet requirements outlined in SFLC Standard Specification 8634. The equipment has been previously proof loaded with no structural modifications, therefore re-load testing is not required. All work must be performed at USCG Yard, Baltimore, MD 21226, with a performance period from May 1-31, 2026. The certifying authority shall determine the type and length of weld inspection required.
The deliverables include a comprehensive Certification Report signed and sealed by a Professional Engineer licensed in the State of Maryland, which must contain completed Appendix B-2, B-23, and B-24 forms from SFLC STD Spec 8634; an inspection overview; inspection findings with supporting documentation; and a surveyor's endorsement noting either "SATISFACTORY" or "UNSATISFACTORY" status with any contingencies clearly noted. Reference documentation includes USCG Drawings YD-085-029, 110WPB-085-010 (Rev. B), and 110WPB-085-016, along with previous certification reports, docking history, and the last Non-Destructive Inspection report and load test documentation, available post-award upon request.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FAR CLAUSES.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Purchase Request # 2126406Y6125705001 Statement of Objectives
WI-001: 110’ WPB Cradle and Spreader Bar Recertification
1. SCOPE
1.1 Intent: The Contractor shall provide services to certify 01 docking cradle and 01 spreader bar identified as 110-foot USCG Cutter Cradle No. 3(CGY-C110-3) and Spreader Bar No. 1 (CGY-S110-1). The slings are NOT part of this certification and are to be certified IAW standard CFR/OSHA requirements. Cradle and spreader has been proof loaded and no structural modifications have been made that would invalidate that proof load test.
2. REFERENCES
COAST GUARD DRAWINGS
United States Coast Guard Drawing No. YD-085-029, Rev -, DOCKING PLAN DOCKING/ LIFTING CRADLE United States Coast Guard Drawing 110WPB-085-010, Rev. B. “110 ft Cutter A, B & C Class. Docking Plan. Docking /Lifting Cradle.” Docking position 1. 6 Sheets. Dated 1-21-1994.
United States Coast Guard Drawing 110WPB-085-016. “110 WPB A, B & C Class. 110 WPB Lifting Arrg’t and Spreader Bar Details.” 4 Sheets. Dated 8-19-1998.
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 8634 (SFLC Std Spec 8634), -2022 Drydocking
OTHER REFERENCES – Available post-award upon request
Previous certification reports Docking history Last Non-Destructive Inspection (NDI) Report Last completed load test
3. REQUIREMENTS
3.1 The Contractor shall conduct all necessary inspections required to certify one docking cradle and one spreader bar, constructed in accordance with referenced drawings. Certification shall meet requirements stated within SFLC STD Spec 8634. Certifying Authority shall provide requirements for type of weld inspection and length of weld inspection required for certification. The cradle has been previously load tested; re-load testing is not required
3.2 .Location: All inspections shall be conducted at USCG Yard, Baltimore MD 21226.
3.3 Period of Performance: All work and applicable deliverables shall be provided between 01 and 31 May, 2026
3.4 Deliverable Requirements: Contractor shall provide a Certification Report, which shall include – at minimum – the following:
3.4.1 Appendix B-2 (of SFLC STD Spec 8634), signed and sealed by a Professional Engineer (State of Maryland)
3.4.2 Appendix B-23 and Appendix B-24 of SFLC STD Spec 8634, completed.
3.4.3 Inspection Overview
3.4.4 Inspection Findings with supporting documentation, as applicable.
3.4.5 Surveyor’s Endorsement, annotated as “SATISFACTORY” or “UNSATISFACTORY”. Any contingencies to endorsement must be clearly noted.