Attachment 2 - Facility Definitions - 70Z03824IH0000016.pdf
PDF 121 KB Posted
- Attached to
- Overhaul of Boosters
- Solicitation number
- 70Z03824IH0000016
About this file
This document is an Attachment titled "Facility Definitions" that outlines the certification requirements for contractors interested in performing overhaul services on components for the United States Coast Guard (USCG).
The key details are as follows:
- Contractors must be FAA-certified, OEM-certified, or DoD/USCG-certified repair facilities to perform the required overhaul services. Specific documentation is required to demonstrate the appropriate certification.
- For FAA-certified facilities, the contractor must submit their repair station certificate and, if the facility has limited ratings, a capabilities list and self-evaluation.
- For OEM-certified facilities, the contractor must submit documentation from the OEM stating they are certified to perform the required services.
- For DoD or USCG-certified facilities, the contractor must provide a signed repair source approval memo indicating they are approved to repair the components.
- The USCG does not maintain or release the technical directive documents required to overhaul these components.
This attachment is referenced in the related federal contract opportunity for the "Overhaul of Boosters" solicitation (Solicitation Number: 70Z03824IH0000016), which is a Sources Sought notice to survey the market and assist the USCG in determining possible sources.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 - List of Items - 70Z03824IH0000016.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 2 – Facility Definitions - 70Z03824IH0000016
FAA-Cer�fied Facility
To demonstrate that the Contractor is properly cer�fied by the FAA, the Contractor must submit their repair sta�on cer�ficate. If the Contractor holds a limited ra�ng, the Contractor must also submit: 1) a capabili�es list iden�fying the relevant part numbers specified on the schedule of services IAW 14 CFR 145.215, and 2) a self-evalua�on affirming that the repair sta�on has all of the housing, facili�es, equipment, material, technical data, processes, and trained personnel in place to perform the work on the ar�cles iden�fied in the schedule of services IAW 14 CFR
145.215. At the request of the Contrac�ng Officer, the Contractor may be required to submit a copy of the repair sta�on manual and quality control manual.
OEM Cer�fied Facility
To demonstrate that the Contractor is cer�fied by the OEM, the Contractor must submit documenta�on from the OEM sta�ng that the Contractor is cer�fied to perform the services required herein. This documenta�on must specifically iden�fy the part numbers iden�fied in the Schedule. Otherwise, the Contractor must provide an OEM point of contact that will allow the USCG to independently verify the Contractor is, in fact, cer�fied by the OEM to repair the components listed on the Schedule.
DoD or USCG Cer�fied Facility
To demonstrate that the Contractor is cer�fied by a DoD service or the USCG to perform overhaul services on the components listed on the Schedule, the Contractor must provide a signed repair source approval memo indica�ng the Contractor is approved to repair the components listed on the Schedule.