3RD FLOOR LIFE SAFETY PLAN A32L02001G104-G104.pdf

PDF 387 KB Posted

Attached to
Replace Flooring at USCG Base New Orleans Administrative Building
Solicitation number
70Z02926QNEWO369
Issued by

About this file

This is a Third Floor Life Safety Plan architectural drawing for the Reconstruction of USCG Integrated Support Command facility in New Orleans, Louisiana. The plan details exit capacity calculations, occupancy loads, and safety provisions for the third floor. The third floor has an occupancy load of 50 people, with required exit capacity of 25 people distributed across multiple exits. Exit capacity calculations are provided using both NFPA and IBC standards, with stair exit capacities ranging from 176 to 265 people and door exit capacities from 170 to 226 people, depending on the applicable code standard. Travel distances to exits are specified as 145 feet, 135 feet, and 161 feet maximum.

The plan indicates the presence of 1-hour rated partitions, illuminated exit signs, fire extinguishers (referenced on sheets A631 and A633), and smoke detectors as required by code. The drawing references additional code data on Sheet G101 and includes a lighting plan reference (E103). The document is prepared by BROADMOOR/BOH BROS., Broadmoor Tower, Metairie, Louisiana, and bears the seal of the U.S. Coast Guard Facilities Design and Construction Center (LANT). The drawing is dated April 1, 2010, with an approval date of January 23, 2009, and is designated as Sheet 6 of 40 pages in the construction document set (Drawing Number 32-L02001, A32L020101G4).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRAVEL DISTANCE 135'-0"TRAVEL DISTANCE 145'-0"

NFPA

STAIR EXIT CAPACITY

53/.3= 176 PEOPLE

IBC

STAIR EXIT CAPACITY

53/.2= 265 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

NFPA

STAIR EXIT CAPACITY

53/.3= 176 PEOPLE

IBC

STAIR EXIT CAPACITY

53/.2= 265 PEOPLE

IBC

DOOR EXIT CAPACITY

34/.2 = 170 PEOPLE

NFPA

DOOR EXIT CAPACITY

34/.15 = 226 PEOPLE

REQ'D. EXIT CAPACITY

25 PEOPLE

REQ'D. EXIT CAPACITY

25 PEOPLE

THIRD FLOOR OCCUPANY LOAD: 50

REFER TO SHEET G101 FOR ADDITIONAL CODE DATA

1 HR. RATED PARTITION

ILLUMINATED EXIT SIGN

RE: (LIGHTING PLAN/E103)

F.E.

FIRE EXTINGUISHER

PER CODE

A631 & A633 (SMOKE)

T R

A V

E L

D

I S

T A

N C

E