This document is a technical specification sheet for the United States Coast Guard Homeland Security Cutter Light (HSC-L), a specialized maritime vessel designed for coastal operations. The cutter measures 69.6 feet in overall length with a 21.5-foot beam and a design draft of 6.0 feet, with air draft capabilities ranging from 17.8 feet folded to 25.6 feet unfolded. The vessel has a lightship weight of 81.5 long tons and full load displacement of 116.7 long tons, with margins totaling 13.3 long tons. The HSC-L is powered by two CAT C18 B engines rated at 500 kW each, producing 1,340 total horsepower, and equipped with two 45-inch fixed pitch propellers and ZF W3350 reduction gears.

The vessel accommodates a crew of six personnel with arrangements including one crew mess (6 persons), one head with shower, one deck head, and one ATON workshop. Performance characteristics include icebreaking capability at 3 knots through 12 inches of ice at 90% MCR, a cruise speed of 10.0 knots, a range of 720 nautical miles at 12 knots, and 3-day endurance. The HSC-L is equipped with buoy tending capability including a 4,500-pound SWL buoy crane for handling buoys up to 5 by 11 feet, cross-deck winches with 2,000-pound SWL each, and an ATON deck load capacity of 16,340 pounds. Additional systems include two 65 kW CAT C4.4 generators, watermist firefighting, keel coolers for machinery cooling, and ABS First Year Ice Class (IC) hull structure certification. Tankage includes 2,700 gallons of fuel oil, 500 gallons of potable water, and 500 gallons of sewage capacity.

View the file

Other files

File Type Posted
Section J-07 Pricing Schedule_A00008.xlsx XLSX spreadsheet
RFP_70Z02326R93280004_HSC-L_Conformed_A00008.pdf PDF
SF-30 Amendment A00008.pdf PDF
Attachment 5 - Government Responses to Solicitation Questions_A00008.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria_A00007.pdf PDF
Section J-54 Hose Log_A00007.xlsx XLSX spreadsheet
Section J-08_Insurance_Spares_List_A00007.pdf PDF
Section J-07 Pricing Schedule_A00007.xlsx XLSX spreadsheet
Section J-01 HSC-L System Specification_A00007.pdf PDF
Section J-09B Tech DataTables_A00007.xlsx XLSX spreadsheet
SF-30 Amendment A00007.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00007.pdf PDF
Attachment 4 - Government Responses to Solicitation Questions_A00006.pdf PDF
SF-30 Amendment A00006.pdf PDF
Section J-13I DD Form 1692 Engineering Change Proposal.pdf PDF
Section J-13D ATCH 085-002 3D TDP.pdf PDF
Section J-13B ATCH 083-001-2 ESWBS WORKBOOK.xlsx XLSX spreadsheet
Section J-09B Tech Data Tables.xlsx XLSX spreadsheet
Section J-13H COMDTINST M10360_3D Colors and Coatings Manual.pdf PDF
Section J-09A Technical Data Rights Table Instructions.pdf PDF
Section J-13L COMDTINST 9085_1D Naval Engineering Computer Aided Design Standards.pdf PDF
Section J-13E SFLC Std Spec 6310 Requirements for Preservation of Ship Structures.pdf PDF
Section J-13M COMDTINST M5260_6A Directives System Program.pdf PDF
Section J-13K ATCH 085-005-2 2D TDP.pdf PDF
Section J-13J ATCH 086-001 2025-04-04 PROMULGATION FRONT MATTER WITH COPYRIGHT (IPW).pdf PDF
Section J-13C ATCH 083-004-1 PPL Template.xlsx XLSX spreadsheet
Section J-06 Notice for Filing Agency Protest.pdf PDF
Section J-10 Section 508 Contract Language for HSC-L.pdf PDF
Section J-11 MIL-HDBK-61B.pdf PDF
Section J-52 Outfitting List.pdf PDF
Section J-07 Pricing Schedule_A00005.xlsx XLSX spreadsheet
Section J-13A ATCH 083-001-1 MECL.xlsx XLSX spreadsheet
Section J-08_Insurance_Spares_List_A00005.pdf PDF
SF-30 Amendment A00005.pdf PDF
Section J-01 HSC-L System Specification_A00005.pdf PDF
Section J-13G COMDTINST M5260_6A Management of Scientific and Technical Information (STINFO).pdf PDF
Section J-53 Sand Chart Template_A00005.xlsx XLSX spreadsheet
RFP_70Z02326R93280004_HSC-L_Conformed_A00005.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria_A00005.pdf PDF
Section J-13N DD Form 1694 Request for Deviation-Waiver.pdf PDF
Section J-13F SFLC Std Spec 6341 Interior Deck Covering.pdf PDF
SF-30 Amendment A00004.pdf PDF
Attachment 3 - Government Responses to Solicitation Questions_A00003.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00003.pdf PDF
SF-30 Amendment A00003.pdf PDF
Attachment 2 - Government Responses to Solicitation Questions_A00002.pdf PDF
SF-30 Amendment A00002.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00002.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria_A00001.pdf PDF
SF-30 Amendment A00001.pdf PDF
Show 40 more

Latest 50 of 58 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DIMENSIONS WEIGHTS

Length, Overall 69.6 ft SWBS 100 45.0 LT 7.0 ft Beam, Overall 21.5 ft SWBS 200 7.6 LT 4.2 ft Depth, To Focsle Deck 11.0 ft SWBS 300 5.2 LT 6.0 ft Depth, To Main Deck 9.0 ft SWBS 400 1.8 LT 16.8 ft Design Draft (DWL) 6.0 ft SWBS 500 12.3 LT 9.4 ft Full Load EOSL Draft 6.3 ft SWBS 600 9.6 LT 9.0 ft Air Draft - Folded 17.8 ft Lightship (LS) 81.5 LT 7.5 ft Air Draft - Unfolded 25.6 ft

Margins PERFORMANCE Total Margin 13.3 LT 12.1 ft Icebreaking @ 3 kts 12 in LS w/ Margin 91.6 LT 8.1 ft Ice Breaking % MCR 90% Icebreaking Load Condition Cruise Speed 10.0 kts Icebreaking Loads 14.8 LT Range @ 12 knots 720 NM Full Load (BOSL) 109.7 LT 7.5 ft Endurance 3 days SLA (7.5% LS) 7.0 LT 0.5 ft

Full Load (EOSL) 116.7 LT 8.0 ft

ARRANGEMENTS PROPULSION SYSTEMS BUOY TENDING

Crew Mess 6 persons Propulsion Engine 2 x CAT C18 B Rating (500 kW) Buoy Crane 4,500 lb SWL WC w/ Shower 1 Propeller 2 x 45 in, 4 Blade, Fixed Pitch Largest Buoy 5 x 11 LR Aids To Navigation Load Condition Deck Head 1 Reduction Gear 2 x ZF W3350 ATON Deck Load 16,340 lbs ATON Loads 25.7 LT ATON Workshop 1 Total BHP 1,340 HP Cross-deck Winch 2 x 2,000 lb SWL Full Load (BOSL) 120.5 LT 7.7 ft

SLA (7.5% LS) 7.0 LT 0.5 ft ACCOMMODATIONS ELECTRIC SYSTEMS MATERIAL Full Load (EOSL) 127.5 LT 8.2 ft 4 person 1 Generator 2 x CAT C4.4 (65 kW) Hull Steel 2 person 1 Total ekW 130 ekW Superstructure Steel TANKAGE Total 6 Fuel Oil gal

AUXILIARY SYSTEMS Potable Water gal TOWING Firefighting Watermist DESIGN STANDARD Sewage gal 1 x 36,500 lb RBS Tow Hawser w/ Bridle Machinery Cooling Keel Coolers ABS First Year Ice Class IC (Hull Structure)

Auxiliary Cooling Fresh Water Loop

Distribution Statement A. Approved for public release: distribution is unlimited.

UNITED STATES COAST GUARD

HOMELAND SECURITY CUTTER LIGHT (HSC-L)

US WEIGHT VCG

6/11/2026

2,700

File details come from the government source that posted it. Updated .