C.2.7 The Contractor shall install and configure device sensors in accordance with manufactures recommendations and industry best practices for optimal detection.
C.2.8 The Contractor shall verify all device sensor locations with the FPS COR/TPOC prior to installation.
C.3 Wireless Point-to-Point
C.3.1 The Contractor shall provide, install, program, and test Point-to-Point wireless devices.
D. IDS Minimum Requirements
D.1 All IDS equipment shall be compatible with Honeywell (Ademco), alarm panels.
D.1.2 At a minimum, the IDS alarm Glass Break Detector shall have the following salient characteristics:
a) Two dip switches to set sensitivity
b) 25’ maximum omnidirectional range, adjustable range
c) Covers all glass types
d) Ceiling mountable
e) Hard wired connections (except for wireless)
f) Compatible with alarm panel
D.1.3 At a minimum, the IDS alarm door contact shall have the following salient characteristics:
a) Surface mountable
b) Magnetic contact
c) Hard wired connections (except for wireless)
d) Compatible with alarm panel
D.1.4 At a minimum, the IDS expansion module shall have the following salient characteristics:
a) Mountable within an enclosure
b) Supports a minimum of 8 up to 16 zones.
c) Hard wired connections
d) Compatible with alarm panel and sensor devices
D.1.5 At a minimum, the Duress/Panic button shall have the following salient Characteristics:
a) Double-pole double-throw contacts for multi-notifications
b) Twin 45° screw terminals with EOL resistor splicing terminal.
c) Adhesive pads for temporary positioning while installing.
70RFPW23QW9000003
May 2023
Amendment 0001
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S C
S C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
S
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
T
C
P
C
P
C
P
C
P
C
P
C
P
C
S
Glass Break
C
T
Door Contact
C
P
Panic Button
Ledgend
C
S
C
S
C
T
C
T
Exsiting Alarm Panel
70RFPW23QW9000003
May 2023
Amendment 0001
Attachment C
| 2023-05-18T06:04:55-0700 | |
| PAUL W METZGER |
File details come from the government source that posted it. Updated .