Question Number
Document (attachment or exhibit)
Paragraph Page Number Question Government Response
1 RFI - Next Generation RIID Procurement - 3June2019_Final
N/A N/A Does CWMD expect that all their requirements are already being met with a COTS solution?
No. CWMD prefers COTS solutions if available. If not available, CWMD will also consider solutions that will become commercially available and also customized COTS solutions.
2 RFI - Next Generation RIID Procurement - 3June2019_Final
N/A N/A Does CWMD value size and weight or ruggedness as more important?
The RIID users envision lifting the detector over-head to scan the outside of trucks; therefore, weight and ruggedness are both important.
3 RFI - Next Generation RIID Procurement - 3June2019_Final
N/A N/A Does CWMD need high resolution (4%) for all of its basic handheld users?
The current requirement to replace devices reaching end-of-life requires 4% resolution.
Future basic hand held user may not need this level of resolution.