70LART19BPFB00003_FLETC_Artesia_Ranges_Drawings.pdf

PDF 7 MB Posted

Attached to
Construct one 100 yard and one 300 yard range
Solicitation number
70LART19BPFB00003
Issued by

About this file

70LART19BPFB00003 Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-001

C

IV

IL

N

O

TE

S

1-

-1

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

GENERAL NOTES

1. THE CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING

OFFICER REGARDING ALL DEMOLITION AND NEW WORK TO BE

ACCOMPLISHED WITHIN THE LIMITS OF CONSTRUCTION.

2. THE CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING

OFFICER THE LOCATION AND LIMITS OF THE CONTRACTOR'S LAYDOWN

AREA.

3. THE CONTRACTOR SHALL EXERCISE CAUTION DURING THE

CONSTRUCTION OPERATIONS SO AS NOT TO DAMAGE AND DISTURB

THE EXISTING & SURROUNDING STRUCTURES AND SO AS NOT TO

CAUSE THE EXISTING STRUCTURES TO BECOME UNSTABLE. UNLESS

OTHERWISE NOTED, THE EXISTING STRUCTURES SHALL REMAIN IN

PLACE.

4. DAMAGE TO PROPERTY AND/OR FACILITIES RESULTING FROM

CONTRACTOR'S OPERATIONS DURING CONSTRUCTION BEYOND THE

LIMITS SHOWN ON THESE PLANS OR AS DIRECTED BY THE

CONTRACTING OFFICER SHALL BE REPAIRED OR REPLACED BY THE

CONTRACTOR. THE COST OF SUCH REPAIRS OR REPLACEMENT SHALL

BE BORNE BY THE CONTRACTOR.

5. EXISTING CONSTRUCTION THAT IS TO REMAIN IN PLACE, BE REUSED,

OR REMAIN THE PROPERTY OF THE GOVERNMENT AND DAMAGED AS A

RESULT OF THE CONTRACTOR'S OPERATION SHALL BE REPLACED WITH

NEW OR REPAIRED TO ITS ORIGINAL CONDITION IN ACCORDANCE WITH

THE SPECIFICATIONS OR AS DIRECTED BY THE CONTRACTING OFFICER

AT NO ADDITIONAL COST TO THE GOVERNMENT.

6. BEFORE PROCEEDING WITH THE WORK, ANY DISCREPANCY BETWEEN

THESE DRAWINGS AND THE EXISTING STRUCTURES SHALL BE

REPORTED TO THE CONTRACTING OFFICER. THE CONTRACTING

OFFICER WILL FURNISH ADDITIONAL DETAILS IF REQUIRED.

7. THE DIMENSIONS AND ELEVATIONS GIVEN FOR THE EXISTING

STRUCTURES AND FOR ASSOCIATED COMPONENTS ARE APPROXIMATE

AND ARE GIVEN FOR ESTIMATING PURPOSES ONLY. DETAIL WORK

SHALL BE BASED ON THE CONTRACTOR'S FIELD MEASUREMENTS.

8. DISCREPANCIES BETWEEN DIFFERENT DRAWINGS SHALL BE REPORTED

TO THE CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO

BEGINNING CONSTRUCTION IN THE AREAS AFFECTED BY SUCH

DISCREPANCIES.

9. THE CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS AND

LICENSES AND KEEP COPIES OF SAME ON SITE DURING

CONSTRUCTION.

10. THE CONTRACTOR SHALL PERFORM A SURVEY TO LOCATE UTILITIES

BEFORE ANY WORK OR EXCAVATIONS.

11. THE CONTRACTOR SHALL PROVIDE SAFETY MARKING BARRICADES,

TEMPORARY FENCING, ETC. AS REQUIRED TO MAINTAIN JOB SITE

SAFETY.

12. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THESE

DRAWINGS AND THE PROJECT SPECIFICATIONS.

13. PRIOR TO DIGGING, CONTRACTOR SHALL CONTACT EACH SERVICE

PROVIDER AND REQUEST THAT A REPRESENTATIVE VISIT THE SITE TO

INSPECT AND CONFIRM IF ANY UTILITIES ARE PRESENT. FEES INCURRED

SHALL BE AT THE EXPENSE OF THE CONTRACTOR.

14. ALL SAFETY REGULATIONS ARE TO BE STRICTLY FOLLOWED.

15. THE CONTRACTOR SHALL ABIDE BY ALL APPLICABLE LOCAL

ENVIRONMENTAL PROTECTION STANDARDS, LAWS, AND REGULATIONS.

16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR BRINGING ALL

ELEMENTS OF THE PROJECT IN CONFORMANCE WITH THESE DRAWINGS

AND SPECIFICATIONS.

17. IF ANY MODIFICATIONS ARE REQUIRED IN ANY ELEMENT, THE

CONTRACTOR SHALL SUBMIT PROPOSED CHANGES TO THE

CONTRACTING OFFICER FOR APPROVAL.

18. CONTRACTOR SHALL PROVIDE AS-BUILT SURVEY AND DRAWINGS OF

COMPLETED WORK TO THE CONTRACTING OFFICER.

19. THE CONTRACTOR SHALL PROTECT ADJACENT STRUCTURES, UTILITIES,

PEDESTRIANS, AND VESSEL AND VEHICULAR TRAFFIC FROM POTENTIAL

DAMAGE DUE TO CONTRACTOR'S OPERATIONS.

20. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFETY AND

PROTECTION OF PERSONNEL, EQUIPMENT, CONSTRUCTION, AND

ADJACENT FACILITIES FOR THE DURATION OF THIS CONTRACT. THE

CONTRACTOR AND HIS SUBCONSULTANTS SHALL PREPARE AND

CONFORM TO A PROJECT SPECIFIC HEALTH AND SAFETY PLAN. THE

GOVERNMENT SHALL NOT BE RESPONSIBLE FOR JOB SITE SAFETY

PROCEDURES.

21. CONSTRUCTION LOADS GREATER THAN 50% OF THE DESIGN LOAD FOR

ANY PORTION OF THE STRUCTURE SHALL NOT BE IMPOSED UNTIL THE

CONCRETE COMPRESSIVE STRENGTH FOR THOSE MEMBERS AND

THEIR CONNECTING POURS HAVE REACHED 80% OF THE 28 DAY DESIGN

COMPRESSIVE STRENGTH.

22. THE CONTRACTOR SHALL REMOVE ALL EQUIPMENT, STAGING AND ANY

OTHER TEMPORARY PLATFORMS AND/OR AREAS AT THE COMPLETION

OF WORK.

23. NO SALVAGE VALUE IS EXPRESSED OR IMPLIED BY THESE CONTRACT

DOCUMENTS FOR THE ITEMS TO BE REMOVED OR DEMOLISHED.

24. BEST MANAGEMENT PRACTICES SHALL BE EMPLOYED DURING PROJECT

CONSTRUCTION TO REDUCE THE POTENTIAL FOR ADVERSE

ENVIRONMENTAL IMPACTS. THE HIGHEST LEVEL OF ATTENTION TO

ENVIRONMENTAL QUALITY IS BEING GIVEN TO THE PROJECT.

CONSTRUCTION PRACTICES SHALL INCLUDE APPROPRIATE SEDIMENT

CONTROL DURING EXCAVATIONS AND CLEARING.

BERM CONSTRUCTION &

EXCAVATION

1. BERM HEIGHTS MUST MEET THE FOLLOWING REQUIREMENTS:

- SIDE BERMS: 15 FEET ABOVE GRADE

- IMPACT BERMS: 18 FEET ABOVE GRADE

2. IMPACT BERMS SHALL HAVE 3 FEET OF CLEAN COVER MATERIAL FREE OF

LEAD OR OTHER CONTAMINANTS.

3. EXCESS CUT SHALL BE PLACED IN BORROW PIT LOCATION DETERMINED BY

THE CONTRACTING OFFICER. DUMP SITE WILL BE WITHIN 2 MILES OF

PROJECT LOCATION.

SKEET RANGE

35163517

UGE

U G

E

U G

E

U G

E

U G

E

UGE

U G

E

10'-0" WIDE DIRT ROAD

GRAVEL ROAD

STEEL POSTS

STEEL POSTS

BLO

C

K W

ALL

BLO

C

K W

ALL

FENCE

50 YD

RANGE

50 YD

RANGE

TRAP

RANGE

RANGE

EAST

RANGE

EAST

RANGE

EAST

E X

IS

T

FE

N

C E

CONCRETE

STORMWATER PIPE, TYP

RANGE 6

RANGE 5

APPROXIMATE

LIMITS OF WORK

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-002

E X

IS

TI

N G

C O

N D

IT

IO

N

-7

-1

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

60' 0' 60' 120'

SCALE: 1''=60'

A1 C-002

EXISTING SITE PLAN

SCALE: 1" = 60'-0"

GENERAL SHEET NOTES

35163517

EXIST DIRT ROAD

EXIST GRAVEL ROAD

BLO

C

K W

ALL

EXIST FENCE

SKEET

RANGE

TRAP

RANGE

EXIST

RANGE

PROPOSED FENCE

EXIST

RANGE

EXIST

RANGE

EL 3519

P-1

EL 3519

P-2

EL 3519

P-3

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-003

G E

O

TE

C H

N

IC

A L

B O

R

IN

G P

LA

1/

/1

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

NOTES

1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. THREE WESTERN RANGES ADDED PER

AERIAL PHOTO TO COMPLETE

TOPOGRAPHIC REPRESENTATION.

60' 0' 60' 120'

SCALE: 1''=60'

N

BORING LOCATIONS

BORING NO LAT LONG NORTHING EASTING

P1 32°52'5.92" 104°28'18.48" 679652.61 498823.90

P2 32°52'6.42" 104°28'15.02" 679703.16 499118.77 P3 32°52'6.46" 104°28'16.72" 679706.93 498974.42

A1 C-003

BORING PLAN

SCALE: 1" = 60'-0"

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-004

B O

R

IN

G L

O G

S

INDX

D A

TE

D

S G

N

D R

FT

C

H K

R

R E

V R

C

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

NOTES

1. BORINGS FROM SCHNABEL

GEOTECHNICAL REPORT DATED 10

DECEMBER 2018.

35163517

UGE

U G

E

U G

E

U G

E

U G

E

UGE

U G

E

DIRT ROAD

GRAVEL ROAD

STEEL POSTS

STEEL POSTS

BLO

C

K W

ALL

BLO

C

K W

ALL

FENCE

50 YD

RANGE 6

EAST50 YD

RANGE

5 EAST

SKEET

RANGE

TRAP

RANGE

RANGE

EAST

RANGE

EAST

RANGE

EAST

472'-0" EXIST DIRT ROAD TO BE ABANDONED

455'-0" EXIST CHAIN LINK FENCE TO BE REMOVED

SEE NOTE

12"Ø GALVANIZED

STORMWATER PIPE

(41 FT) 12"Ø GALVANIZED

STORMWATER PIPE

(41 FT)

EXISTING FENCE

TO BE REMOVED

EXISTING GRADE, TYP

WP 10

WP 11

WP 12

WP 13

140'-0"

140'-0"

25'-0"

25'-0"

℄ BERM

D1

CD-301

3'-11" TYP

8'

-2

1 4" WORKING POINTS

POINT NO

WP B10

WP B11

WP B12

WP B13

NORTHING

679962.4270

679950.5344

679978.1721

679969.1981

EASTING

498298.6490

498770.5047

498310.1362

498765.0374

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

CD-100

D E

M O

LI

TI

O N

B

E R

M D

E C

O N

S

TR

U C

TI

O

N P

2-

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

RELOCATE LEAD CONTAMINATED

SOIL FOR REUSE AS CORE OF

NEW IMPACT BERM

DEMOLISH

60' 0' 60' 120'

SCALE: 1''=60'

A1

CD-100

DEMOLITION PLAN

SCALE: 1" = 60'-0"

N

SHEET KEYNOTES

LEGEND

1. CONTRACTOR TO REMOVE FENCE

COMPONENTS TO NEAREST FENCE POST,

SEE SHEET CD-301.

2. 59.5 CY CONCRETE (CONCRETE SLAB

ASSUMED TO BE 4" THICK), SEE SHEET

CD-302.

3. EXIST RANGE BERM DEMO, SEE SHEET

CD-301.

1.5

15.31' 5.67' 19.88'

EL 3526

EXISTING GRADE

CL BERM

5.00' 5.00'

2.00'

EXISTING 12" CMP

7' -0

1'

-0

10'-0" TYP 10'-0" TYP

SEE NOTE 2, TYP

POST TO REMAIN

POST TO REMAIN

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

CD-301

D E

M O

LI

TI

O N

B

E R

M D

E C

O N

S

TR

U C

TI

O

N S

E C

TI

O

2/

/1

JM R

W

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

D1

CD-100

EXISTING BERM DEMOLITION SECTION - TYP

SCALE: 1" = 5'-0"

RELOCATE LEAD CONTAMINATED

SOIL FOR REUSE AS CORE OF

NEW IMPACT BERM

DEMOLISH

DEMOLISH

LEGEND

5' 0' 5' 10'

SCALE: 1''=5'

GENERAL SHEET NOTES

1. ALL DIMENSIONS & ELEVATIONS ARE

FROM SMA SURVEY ON 11/29/18.

2. FILL & COMPACT VOID AFTER

DEMOLISHING CONCRETE FOOTING.

A1

CD-301

EXISTING FENCE DEMOLITION SECTION

SCALE: 1" = 20'-0"

20' 0' 20' 40'

SCALE: 1''=20'

18.41'

4" TYP

5.88'11.83'

EXISTING

GRADEEXISTING CONCRETE

EXISTING

CONCRETE

(BEYOND)

EXISTING

CONCRETE

(BEYOND)

EXISTING

CONCRETE

9.11' 5.12'

EXISTING

CONCRETE

102'-2"

'-4

'-1 0"

6'-3"

'-8

3'-11 1/2"

DEMO 25 STATIONARY

TARGETS

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

CD-302

D E

M O

LI

TI

O N

R A

N G

E D

E C

O N

S

TR

U C

TI

O

N S

E C

TI

O

5/ 9/

JM R

W

JM

TE

S

A

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

RELOCATE LEAD CONTAMINATED

SOIL FOR REUSE AS CORE OF

NEW IMPACT BERM

DEMOLISH

DEMOLISH

LEGEND

C3

CD-302

EXISTING CONCRETE DEMOLITION SECTION

SCALE: HORIZ 1"=5'-0" VERT 1"=1'-0"

A3

CD-302

RANGE 6 (VIEW)

NTS

C3

CD-302

B1

CD-302

RANGE 6 - DEMO PLAN

SCALE: 1"=16'-0"

A3

CD-302

5' 0' 5' 10'

HORIZONTAL SCALE: 1''=5'

1' 0' 1' 2'

VERTICAL SCALE: 1''=1'

16' 0' 16' 32'

SCALE: 1''=16'

35163517

EXIST DIRT ROAD

EXIST GRAVEL ROAD

BLO

C

K W

ALL

EXIST FENCE

SKEET

RANGE

TRAP

RANGE

EXIST

RANGE

EAST

NEW EAST

RETENTION

POND

200'x200'

NEW FENCE

EXIST

RANGE

EAST

EXIST

RANGE

EAST

35193519

EL 3532.00

EL 3532.00

EL 3532.00

EL 3535.00

EL 3535.00

EL 3535.00

EL 3535.00

EL 3532.00

EL 3532.00

EL 3532.00

EL 3532.00

EL 3532.00

EL 3512.52

EL 3512.00

EL 3513.50

EL 3507.00

EL 3511.00

EL 3526.78

136' TYP

136' TYP

NEW WEST

DETENTION

POND

100'x350'

NEW CONCRETE SPILLWAY BOX

5'L x 5'W x 3.5'H , SEE .

NEW 30"Ø

STORM DRAIN

CULVERT PIPE

NEW 36"Ø

STORM DRAIN

CULVERT PIPE

NEW DROP INLET

5.5'L x 4.5'W x 4'H , SEE .

NEW 12"Ø RCP

SEE .

0.5%

0.5%

B1 C-502

D4 C-502

NEW 12"Ø

STORM DRAIN

CULVERT PIPE

NEW

RANGE 5

300 YD

SEE C-401

NEW

RANGE 6

100 YD

SEE C-402

1%

1%

8'

12'

8'

12'

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-101

S

IT

E P

9/

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

60' 0' 60' 120'

SCALE: 1''=60'

B1 C-302

C1 C-302

D1 C-302

A1 C-303

B1 C-303

C1 C-303

E1 C-303

N

A1 C-101

SITE PLAN

SCALE: 1" =60'-0"

1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

4. THREE WESTERN RANGES ADDED PER

AERIAL PHOTO TO COMPLETE

TOPOGRAPHIC REPRESENTATION.

GENERAL SHEET NOTES

ROAD & FENCE LAYOUT

SEE

C1 C-103

1. NEW 12" STORM DRAIN CULVERT PIPE @

S = 1.5%, L = 78' INV IN ELEV = 3514.5' / INV

OUT ELEV = 3513.35'.

2. FIRING BERM SEE SHEET S-301.

SHEET KEYNOTES

EXIST DIRT ROAD

EXIST GRAVEL ROAD

BLO

C

K W

ALL

EXIST FENCE

NEW

RANGE 6

100 YD

NEW

RANGE 5

300 YD

SKEET

RANGE

TRAP

RANGE

EXIST

RANGE

EAST

NEW EAST

RETENTION

POND

200'x200'

NEW FENCE

EXIST

RANGE

EAST

EXIST

RANGE

EAST

136' TYP

TOE OF BERM

136' TYP

TOE OF BERM

NEW WEST

DETENTION

POND

100'x350'

NEW DIRT ROAD

PROPOSED GRADE, TYP

NEW CHAIN LINK FENCE

BL BERM 5 EAST

BL BERM 6 EAST

0+00

1+00

2+00

3+00

4+00

5+00

6+00

7+00

8+00

9+00

10+00

11+00

12+00

13+00

14+00

15+00

16+00

17+00

18+00

19+00

20+00

21+00

BP: 0+00.00

EP: 21+18.69

PI: 9+04.95

PI: 12+19.73

PI: 16+41.94

PI: 16+92.69

PI: 17+37.69

PI: 17+60.19

PI: 18+20.47

PC: 9+58.50

PC: 11+24.84

PT: 9+93.84

PT: 11+60.19

0+00

1+00

2+00

3+00

4+00

5+00

BP: 0+00.00

PI: 3+01.40

PC: 3+58.50

PT: 3+93.84

EP: 5+47.34

EL 3512.50

EL 3507.00

EL 3511.00

EL 3526.78

WP D1

WP D2

WP D3

WP D4

WP D5

WP D6

WP D7

WP D8

L1

S1

C1

L2

C2

S2

L3

S3

L4

S4

L5

L1

S1

C1 L2

BL BERM 5 EAST

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-102

B A

S E

L

IN

E C

O N

TR

O

L P

2/

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

60' 0' 60' 120'

SCALE: 1''=60'

B1 C-302

C1 C-302

D1 C-302

A1 C-303

B1 C-303

C1 C-303

E1 C-303

N

A1 C-102

SITE PLAN FINAL CONDITION

SCALE: 1" = 60'-0"

1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

4. THREE WESTERN RANGES ADDED PER

AERIAL PHOTO TO COMPLETE

TOPOGRAPHIC REPRESENTATION.

5. BASELINE DATA, SEE SHEET C-601.

6. FOR DETENTION POND & RETENTION

POND WORKING POINT DATA SEE SHEET

C-601.

7. FOR ROADWAY AND FENCE LAYOUT SEE

SHEET C-103.

GENERAL SHEET NOTES

D4 C-301

D4 C-301

D1 C-301

D1 C-301

XX

EXIST DIRT ROAD

EXIST FENCE

PROPOSED FENCE

PROPOSED ROADWAY

10'-0"

TYP

16'-0" C

LR

10'-0"

TYP

EXIST DIRT ROAD

EXIST FENCE

RANGE 5 (300 YD)

RANGE BERM

0+00

1+00

2+00

3+00

4+00

5+

5+97

BP: 0+00.000

EP: 5+97.345 PC: 5+38.229

PC: 4+15.616

PC: 2+23.355

PT: 4+61.561

PT: 2+84.616

PT: 0+42.825

C1

L1

C2

L2

C3

L3 C4

WP F1

WP F2

WP F3

WP F4

WP P1

WP P2

WP P3

WP P4

C1 C-301

0+00

B P

(P C

) 0 +0

.9

1+002+003+004+005+006+00

P T

0+

.8

.2

P C

+2

3.

.9

P T

2+

.6

.1

P C

+1

5.

.6

P T

4+

.5

.8

P C

+3

8.

.1

E P

(P T)

+9

7.

.3

CENTERLINE OF ROAD

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-103

R O

A D

F

E N

C E

P

3/

/1

JM D

C

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

30' 0' 30' 60'

SCALE: 1''=30'

N 1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

4. BASELINE DATA, SEE SHEET C-602.

5. FOR FENCE & ROAD WORKING POINT

DATA SEE SHEET C-602.

GENERAL SHEET NOTES

XX

C1 C-101

ROAD & FENCE LAYOUT PLAN

SCALE: 1" = 30'-0"

A1 C-103

ROAD PROFILE

SCALE: 1" = 30'-0"

15'-0" 10'-0" 15'-0"

'-0

CL BERM

EL 3532

EXISTING GRADE

18'-0" 10'-0" 18'-0"

'-0

CL BERM

EL 3535

EXISTING GRADE

COVER MATERIAL

CORE MATERIAL

(FROM EXISTING

IMPACT BERMS)

3'-0"

TYP

1%

2'-0" 10'-0" 2'-0"

2'-0" 2'-0" 2'-0"

2' -0

CL BERM

EXISTING GRADE

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-301

E A

R

TH

W O

R K

TY

P

IC

A

L S

E C

TI

O

-7

-1

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

C1 C-103

TYPICAL ROADWAY SECTION

SCALE: 1/4" = 1'-0"

D1 C-102

TYPICAL SIDE BERM SECTION

SCALE: 3/16" = 1'-0" D4

C-102

TYPICAL IMPACT BERM SECTION

SCALE: 3/16" = 1'-0"

8'-0" 0'-0'' 4'-0" 8'-0"

SCALE: 3/16"=1'-0''

4'-0" 0'-0'' 4'-0" 8'-0"

SCALE: 1/4"=1'-0''

C4 C-301

TYPICAL FIRING BERM - RANGE 5

SCALE: 1/2" = 1'-0"

PRIMARY CL PROFILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

EL 3535.0

300 YDS (900'-0")

FIRING LINE TARGET AREA

IMPACT BERM

EXISTING BERM

EL 3512.5

EL 3517.0

EL 3517.0

PROPOSED GRADE

EXISTING GRADE

EXISTING

GRADE

EAST CL PROFILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

EL 3535.0

EL 3507.0

100 YDS (300'-0")

200'-0"

FIRING LINE

EXISTING BERM

EL 3516.25

EXISTING

GRADE

TARGET AREA IMPACT BERM

EL 3514.5 PROPOSED GRADE

EXISTING GRADE

DITCH

WEST CL PROFILE

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00

EL 3512.0

350'-0"

PROPOSED GRADE

EXISTING GRADE

EXISTING BERM

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-302

TY

P

IC

A

L S

E C

TI

O

N S

S H

E E

T

O F

-2

0-

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

B1 C-102

PROFILE - 300 YD RANGE

SCALE: HORZ. 1"=50' VERT. 1"=12'

C1 C-102

PROFILE - 100 YD RANGE & EAST RETENTION BASIN

SCALE: HORZ. 1"=50' VERT. 1"=12'

D1 C-102

PROFILE - WEST DETENTION BASIN

SCALE: HORZ. 1"=50' VERT. 1"=12'

50' 0' 50' 100'

HORIZONTAL SCALE: 1''=50'

12' 0' 12' 24'

VERTICAL SCALE: 1''=12'

-500 -450 -400 -350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 450 500

EL 3532.0

BERM

EXISTING GRADE 300 YD

RANGE FLOOR

100 YD

RANGE FLOOR

PROPOSED GRADE

-500 -450 -400 -350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 450 500

EL 3532.0

EL 3507.0

1VARIES

EL 3512.0 MIN

200'-0"

100'-0"

BERM, TYP

EXISTING GRADE

300 YD

RANGE FLOOR

EAST RETENTION POND

WEST

DETENTION POND

PROPOSED GRADE

NEW DROP INLET

5.5'L x 4.5'W x 4'H

NEW 36"Ø STORM

DRAIN CULVERT PIPE

8+50.00

-500 -450 -400 -350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 450 500

EL 3532.0

100'-0"

VARIES

EL 3512.0 MIN

BERM, TYP

EXISTING GRADE

300 YD

RANGE FLOOR

WEST

DETENTION POND

PROPOSED GRADE

CONCRETE SPILLWAY BOX

5'L x 5'W x 3.5'H

10+00.00

-500 -450 -400 -350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350 400 450 500

EL 3532.0

BERM, TYPEXISTING GRADE

300 YD

RANGE FLOOR

PROPOSED GRADE

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-303

TY

P

IC

A

L S

E C

TI

O

N S

H E

E T

O

F

-2

0-

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

A1 C-102

RANGE SECTION

SCALE: HORZ. 1"=50' VERT. 1"=12'

B1 C-102

RANGE SECTION

SCALE: HORZ. 1"=50' VERT. 1"=12'

C1 C-102

RANGE SECTION

SCALE: HORZ. 1"=50' VERT. 1"=12'

E1 C-102

RANGE SECTION

SCALE: HORZ. 1"=50' VERT. 1"=12'

50' 0' 50' 100'

HORIZONTAL SCALE: 1''=50'

12' 0' 12' 24'

VERTICAL SCALE: 1''=12'

136' TYP

1% 1%

100yd TURNING

TARGETS

12L & 13R (25 TOTAL)

SIDE BERMSIDE BERM

FIRING LINE

EXISTING

CONTROL TOWER

EXISTING

PAVILION

NEW 36"Ø STORM

DRAIN CULVERT PIPE

NEW DROP INLET

EXISTING

CONCRETE

APRON

FIRING BERM

136' TYP

1% 1%

300yd POPUP

STATIONARY

TARGETS

6L & 6R

200yd POPUP

STATIONARY

TARGETS

6L & 6R

SIDE BERM

IMPACT BERM

SIDE BERM

NEW 30"Ø

DRAIN

CULVERT PIPE

FIRING BERM

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-401

R A

N G

E

P

LA

N

Y

7-

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

30' 0' 30' 60'

SCALE: 1''=30'

A1 C-401

RANGE 5 - PLAN (300 YD)

SCALE: 1" = 30'

MATCHLINE

MATCHLINE

N

1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

GENERAL SHEET NOTES

D1 C-301

D1 C-301

D4 C-301

EXIST GRAVEL ROAD

13 - 100 YD TARGETS

ON CONRETE SLAB

SPEAKER; SEE

ELEC SHEETS

PROVIDE 10ft

LOGS, 3 TOTAL

TRUCK

(OFCI)

DITCH

25'

CLR

FIRING LINE

RAISED

SOIL BERM

TRUCK

(OFCI)

FIRING WALL,

SEE SHEET C-504

136' TYP

1%

IMPACT BERM

SIDE BERM

SIDE BERM

3 BOULDERS

(4', 5', 6' DIA)

EXISTING

CONTROL TOWER

EXISTING

PAVILION

PROVIDE 12"Ø STORM

DRAIN CULVERT PIPE

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-402

R A

N G

E

P

LA

N

Y

7-

JM R

W

JM

TE

S

B

A

S

UB

M

IS

SI

ON

1/

9/

TD

B

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

30' 0' 30' 60'

SCALE: 1''=30'

A1 C-402

RANGE 6 - PLAN (100 YD)

SCALE: 1" = 30'

N 1. TOPOGRAPHIC DATA REFERENCED FROM

SOUDER, MILLER & ASSOCIATES

TOPOGRAPHIC SURVEY MN FLETC

ARTESIA, NEW MEXICO, NOV. 2018

2. COORDINATE SYSTEM: MODIFIED STATE

PLANE 1983, NEW MEXICO EAST ZONE

(3001).

3. VERTICAL DATUM: NAVD 1988

GENERAL SHEET NOTES

D4 C-301

D1 C-301

TYP

1. PROVIDE TENNIS BALL LAUNCHER WITH PAD,

BY 'SPINSHOT PLAYER' OR APPROVED EQUAL.

LAUNCHER SHALL PROVIDE THE FOLLOWING:

1) PHONE BASED REMOTE CONTROL, BOTH

ANDROID AND IPHONE COMPATIBLE.

2) ELECTRONICALLY ADJUSTABLE BALL

TRAJECTORY.

3) OSCILLATION PROGRAMMING, 6 PROGRAMS

MINIMUM.

4) POWER SUPPLY SHALL BE BOTH AC AND

BATTERY CAPABLE.

5) CONSTRUCTION WILL BE A WEATHER-PROOF

HOUSING.

POST CAP

10'-0" MAX

TENSION WIRE

2" G

A P

7' -0

" M

IN

1' -0

10'-0" MAX

3 12" Ø FENCE / GATE

POST (TYP)

CHAIN LINK FENCING

FINISH GRADE

CONCRETE FOOTING

3' -0

6"

3 STRAND

BARBED WIRE

1' -0

'-0

FENCE POST

#8 AWG SOLID

COPPER WIRE

ATTACH TO METAL

FENCE POST

WITH GROUND CLAMP

4" DIA COPPER-CLAD

STEEL GROUND ROD

MOLDED EXOTHERMIC

WELD OR APPROVED

CLAMP-TYPE FITTING

OF BRONZE

1' -0

1'-10" 7 1 2 "

4" LARGE FLANGE

STRUCTURAL BLIND

REVIT (TYP)

BARBED WIRE

STRAND (TYP) LOCKED PIN OR Z CUT

IN BARBWIRE ARM

(TYP)

1' -0

1'-6"6"

4" LARGE FLANGE

STRUCTURAL BLIND

REVIT (TYP)

BARBED WIRE

STRAND (TYP) LOCKED PIN OR Z CUT

IN BARBWIRE ARM

(TYP)

LINE POST CORNER POST

PLAN

ELEVATION

BRACE RAIL

BOLT & NUT

BRACE BAND

RAIL END w/ OFFSET

LUG

BRACE OR BOTTOM

RAIL

TENSION OR

FABRIC BAND

TENSION BARTENSION BAR

TRUSS ROD

TURNBUCKLE

CORNER OR END OR

GATE POST

PLAN - ROUND POST

16" (8mm) #

BOLT W/HEX NUT

BRACE OR BOTTOM

BRACE OR BOTTOM RAIL

RAIL END w/ OFFSET LUG

BRACE BAND

ROUND LINE POST

ELEVATION - ROUND POST

TRUSS ROD

PLAN - ROUND POST ELEVATION - ROUND POST

ELEVATION - ROUND POST

FENCE FABRIC

9-GAGE STEEL TIE WIRE

(15" O.C. MAX AND WITHIN

4" FROM TOP AND BOTTOM

OF FABRIC)

9-GAGE STEEL TIE WIRES

(2'-0" O.C. MAX)

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-501

FE

N

C E

D E

TA

IL

3-

-1

JM S

H

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

1. FABRIC: THE STANDARD FENCE FABRIC SHALL BE "ZINC" OR

ALUMINUM-COATED STEEL WIRE CHAIN LINK WITH MESH

OPENINGS NOT LARGER THAN TWO INCHES PER SIDE AND A

TWISTED AND BARBED SELVAGE AT TOP AND BOTTOM IN

ACCORDANCE WITH THE SPECIFICATIONS. UTILIZE 6-GAUGE

FOR BASE PERIMETER OR HEIGHTENED SECURITY ZONES.

2. FABRIC TIES: ONLY 12-GAUGE STEEL TIES SHALL BE USED

COATING OR PLATING WILL BE ELECTROLYTICALLY

COMPATIBLE WITH THE FENCE FABRIC TO INHIBIT

CORROSION.

3. REINFORCEMENT: TENSION WIRES SHALL BE INSTALLED

AND INTERWOVEN (OR AFFIXED WITH FABRIC TIES) ALONG

THE TOP & BOTTOM OF THE FENCE FOR STABILIZATION OF

THE FENCE FABRIC.

4. FENCE HEIGHT: CHAIN LINK FABRIC SHALL BE 7" HIGH WITH

AN ADDITIONAL 1' IN HEIGHT COMPOSED OF 3 STRANDS OF

BARBED WIRE AS REQUIRED. THE TOTAL FENCE HEIGHT

SHALL BE 8'.

5. GROUND CLEARANCE: BOTTOM OF THE FENCE FABRIC

SHALL BE WITHIN TWO INCHES OF FIRM SOIL.

6. TOP GUARDS: A TOP GUARD IS AN OVERHANG OF BARBED

WIRE ALONG THE TOP OF A FENCE. FACING OUTWARD

(AWAY FROM PROTECTED SITE) AND UPWARD AT

APPROXIMATELY 45° ANGLE TOP GUARD SUPPORTING ARMS

WILL BE PERMANENTLY AFFIXED TO THE TOP OF FENCE

POSTS TO INCREASE THE OVERALL HEIGHT OF THE FENCE

AT LEAST 1 FOOT. THREE STRANDS OF 12-GAUGE BARBED

WIRE, EQUALLY SPACED, SHALL BE INSTALLED ON THE

SUPPORTING ARMS.

7. FENCE POSTS: SHALL BE ASTM F1043 OR F1083 ROUND PIPE

AND SHALL BE GALVANIZED IN ACCORDANCE WITH THE

SPECIFICATIONS. FENCE POST SPACING AND SIZE

(DIAMETER) SHALL BE DETERMINED IN ACCORDANCE WITH

CHAIN LINK FENCE MANUFACTURERS INSTITUTE (WLG 2445).

SPACING SHALL NOT BE LESS THAN THAT SPECIFIED.

CHAIN LINK FENCING NOTES

16'-0" 0'-0'' 16'-0" 32'-0"

SCALE: 1/16"=1'-0''

C1 C-501

TYPICAL FENCING ELEVATION

SCALE: 1/16" = 1'-0"

A1 C-501

GROUNDING DETAIL

SCALE: NTS

TOP GRATECONCRETE WALL

5'-0"

REINFORCED

CONCRETE SLAB

ELEV = 3515.50

ELEV = 3513.25

ELEV = 3512.00

NEW 30" STORM DRAIN

CULVERT PIPE

@ S = 1%

LOW DRAIN PORT

3x9" DIAMETER

INCLINE ORIFICE

TOP GRATE

NEW 30" STORM DRAIN CULVERT

PIPE @ S = 1%, L ≈ 360'

INV. IN ELEV = 3512.0'

INV. OUT ELEV = 3508.2'

NEW CONCRETE SPILLWAY BOX

5' L x 5' W x 3.5' H

TOP ELEV = 3515.50'

BOTTOM ELEV = 3512.06"

INV. IN ELEV = 3512.0'

INCLINE ORIFICE

100'-0"

DETENTION

POND SLOPE

INV. ELEV = 3508'

NEW 36" Ø STORM DRAIN

CULVERT PIPE @ S=1%, L=100'

INV. IN ELEV = 3508'

INV. OUT ELEV = 3507'

NEW DROP INLET

5.5' Lx4.5' Wx4' H

TOP ELEV = 3512.0'

BOT. ELEV = 3508.0'

TOP GRATE

INV. ELEV = 3508.2'

30" STORM DRAIN CULVERT PIPE

INCOMING FROM SPILLWAY BOX

(FROM WEST DETENTION POND)

FE

D

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-502

D R

A

IN

A G

E D

E

TA

IL

/1

K M

S H

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

NOTES

1. FIRST ROW OF THREE 9" DIAMETER REVERSE INCLINED ORIFICE

ON EACH 3 SIDES OF THE BOX WILL BE LOCATED WITH INVERT

ELEVATION AT 3512.0'

2. SECOND ROW OF THREE 9" DIAMETER REVERSE INCLINED

ORIFICE ON EACH 3 SIDES OF THE BOX WILL BE LOCATED WITH

THE INVERT ELEVATION AT 3513.25'.

3. THE REVERSE INCLINE PORTS ARE INCLUDED AS STORMWATER

QUALITY IMPROVEMENT FEATURES WHICH ENSURES THAT

FLOATABLE DEBRIS WILL NOT ENTER THE PRINCIPAL SPILLWAY

BOX. THESE WILL FUNCTION AS ORIFICE FLOW UNTIL SUBMERGED

WITHIN THE PRINCIPAL SPILLWAY BOX, AND THEN THE PORTS

WILL BE NON-FUNCTIONAL. THE PORTS ARE 9-INCH PIPES SET AT

A 45 DEGREE ANGLE WITH THE INSIDE OR UPPER PIPE INVERT

SET AT AN ELEVATION AT OR HIGHER THAN THE OUTSIDE OR

LOWER PIPE SOFFIT ELEVATION.

4. LOW DRAIN PORTS ARE LOCATED AT THE INVERT ELEVATION OF

THE SPILLWAY BOX WALL.

1' 0' 1' 2'

SCALE: 1''=1'

D1 C-101

CONCRETE SPILLWAY BOX ELEVATION

SCALE: 1"=1'-0"

B1 C-101

DETAIL CONCRETE SPILLWAY BOX

SCALE: 1"=1'-0"

D4 C-101

DROP INLET ELEVATION

SCALE: 1"=1'-0"

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-601

B A

S E

LI

N

E

W O

R K

P O

IN

T

D A

TA

B

E R

M

E A

T

/1

JM R

W

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

BERM 5 EAST

SEGMENT NO LENGTH RADIUS BEG NORTHING BEG EASTING START STATION START ELEV END NORTHING END EASTING END STATION END ELEV

L1 904.95 679089.71 498648.17 0+00.00 3532 679967.68 498428.88 9+04.95 3532

S1 53.55 679967.68 498428.88 9+04.95 3532 680019.64 498415.91 9+58.50 3535

C1 35.34 22.5 680019.64 498415.91 9+58.50 3535 680046.92 498432.28 9+93.84 3535

L2 131.00 680046.92 498432.28 9+93.84 3535 680078.67 498559.39 11+24.84 3535

C2 35.34 22.5 680078.67 498559.39 11+24.84 3535 680062.29 498586.66 11+60.19 3535

S2 59.55 680062.29 498586.66 11+60.19 3535 680004.52 498601.09 12+19.73 3532

L3 422.20 680004.52 498601.09 12+19.73 3532 679594.90 498703.40 16+41.94 3532

S3 50.75 679594.90 498703.40 16+41.94 3532 679545.66 498715.69 16+92.69 3535

L4 67.50 679545.66 498715.69 16+92.69 3535 679480.17 498732.05 17+60.19 3535

S4 60.28 679480.17 498732.05 17+60.19 3535 679421.68 498746.66 18+20.47 3532

L5 298.22 679421.68 498746.66 18+20.47 3532 679132.36 498818.92 21+18.69 3532

BERM 6 EAST

SEGMENT NO LENGTH RADIUS BEG NORTHING BEG EASTING START STATION START ELEV END NORTHING END EASTING END STATION END ELEV

L1 301.40 679175.01 498989.68 0+00.00 3532 679467.43 498916.64 3+01.40 3532

S1 57.10 679467.43 498916.64 3+01.40 3532 679522.82 498902.81 3+58.50 3535

C1 35.34 22.50 679522.82 498902.81 3+58.50 3535 679539.20 498875.52 3+93.84 3535

L2 153.50 679539.20 498875.52 3+93.84 3535 679502.00 498726.60 17+37.69 3535

DETENTION PONDS

WORK POINT NO NORTHING EASTING

D1 679430.48 498356.82

D2 679770.05 498272.01

D3 679794.28 498369.03

D4 679454.72 498453.84

D5 679595.35 498790.81

D6 679789.39 498742.35

D7 679837.85 498936.39

D8 679643.81 498984.85

E R

A L

LA

W

E N

FO

R

C E

M E

N T

TR

A

IN

IN

G C

E N

TE

R

A R

TE

S

IA

B

O R

D E

R P

A

TR

O L

Y A

R D

Y

A R

D

TA

C

TI

C A

L A

W A

R E

N E

S S

T R

A

IN

IN

G

R A

N G

E S

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

INDEX: OF

C-602

B A

S E

LI

N

E

W O

R K

P O

IN

T

D A

TA

R

O A

D W

A Y

F

E N

C E

/1

JM D

C

JM

TE

S

A

A

S

UB

M

IS

SI

ON

4/

2/

TD

C

0% S

UB

M

IS

SI

ON

5/

/1

TD

D

FI

NA

L

SU

BM

IS

SI

ON

7/

/1

TD

ROADWAY

SEGMENT NO LENGTH RADIUS BEG NORTHING BEG EASTING START STA START ELEV END NORTHING END EASTING END STATION END ELEV PI NORTHING PI EASTING

C1 42.82' 56.00' 679950.64 498770.51 0+00 3522.90 679967.68 498732.36 0+42.82 3523.22 679951.49 498748.01 L1 180.53' 679967.68 498732.36 0+42.82 3523.22 680097.49 498606.90 2+23.36 3523.95 C2 61.26' 58.50' 680097.49 498606.90 2+23.36 3523.95 680113.60 498550.66 2+84.62 3524.18 680121.78 498583.42 L2 131.00' 680113.60 498550.66 2+84.62 3524.18 680081.85 498423.56 4+15.62 3524.65 C3 45.95' 58.50' 680081.85 498423.56 4+15.62 3524.65 680055.20 498387.58 4+61.56 3524.80 680075.98 498400.05 L3 76.67' 680055.20 498387.58 4+61.56 3524.80 679989.47 498348.12 5+38.23 3525.10 C4 59.12' 56.00' 679989.47 498348.12 5+38.23 3525.10 679962.31 498298.68 5+97.34 3525.35 679961.4800 498331.32

FENCE

W P NO NORTHING EASTING

F1 679969.20 498765.04

F2 680141.73 498597.29

F3 680089.62 498388.62

F4 679978.17 498310.14

E-001

LE

G

E N

D , S

C H

E D

U

LE

S

A N

D G

E N

E R

A L

N O

TE

S

GENERAL SHEET NOTES

LEGEND

UNDERGROUND CONTROL CONDUIT

EXISTING POWER PANEL - SURFACE

MOUNT

CONDUIT TURNING UP

CONDUIT TURNING DOWN

UNDERGROUND COMPRESSED AIR CONDUIT

PANEL 'R5P' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 100 A MAIN LUG ONLY, 10kAIC, NEMA 4X

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

EXISITNG 20 1 1.0 01

7.1

2 40 TS-100LC

EXISTING 20 1 1.0 03 5.8

EXISTING 20 1 1.0 05

0.9

2 40 TS-200LC

SPARE 20 1 07 0.9

SPARE 20 1 09

0.9

2 40 TS-300LC

SPARE 20 1 11 0.9

SPARE 20 1 13 14 0.5 1 20 RECP - RANGE HOUSE TARGET CONTROLLER

SPARE 20 1 15 16 0.5 1 20 RECP - RANGE HOUSE TARGET CONTROLLER

SPARE 20 1 17 18 1 20 SPARE

SPARE 20 1 19 20 1 20 SPARE

SPARE 20 1 21 22 1 20 SPARE

SPARE 20 1 23 24 1 20 SPARE

2.0 1.0 9.4 8.1

TOTAL CONNECTED

kVA/PHASE

11.4 9.1

TOTAL CONNECTED kVA 20.5

PANEL 'TS5-100LC' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 60 A MAIN LUG ONLY, 10kAIC, NEMA 4X

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

RECP - 100 YD TARGETS 20 1 1.0 01

2 20 SPARE

SPARE 20 1 0 03 0

SPARE 20 1 05

06 2 20 SPARE

SPARE 20 1 07

SPARE 20 1

09 10 2 20 SPARE

SPARE 20 1

1.0 0.0 0.0 0.0

TOTAL CONNECTED

kVA/PHASE

1.0 0.0

TOTAL CONNECTED kVA 1.0

PANEL 'TS5-200LC' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 60 A MAIN LUG ONLY, 10kAIC, NEMA 4X

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

SPARE 20 2

01 02 2 20 SPARE

0 0

SPARE 20 2 05

06 1.0 1 20 RECP - 200YD TARGETS

08 1 20 SPARE

SPARE 20 2 09

10 1 20 SPARE

12 1 20 SPARE

0.0 0.0 1.0 0.0

TOTAL CONNECTED

kVA/PHASE

1.0 0.0

TOTAL CONNECTED kVA 1.0

PANEL 'TS5-300LC' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 60 A MAIN LUG ONLY, 10kAIC, NEMA 4X

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

SPARE 20 2

01 02 2 20 SPARE

0 0

SPARE 20 2 05

06 1.0 1 20 RECP - 300YD TARGETS

08 1 20 SPARE

SPARE 20 2 09

10 1 20 SPARE

12 1 20 SPARE

0.0 0.0 1.0 0.0

TOTAL CONNECTED

kVA/PHASE

1.0 0.0

TOTAL CONNECTED kVA 1.0

A

20A, 125V, 2P, 3W, NEMA 5-20R RECEPTACLE

IN WEATHERPROOF BOX AND GASKETED

COVER

1. CONTRACTOR SHALL PROVIDE BRANCH CIRCUIT WIRING TO

ALL ITEMS THAT REQUIRE ELECTRICAL CONNECTIONS.

WHERE BRANCH CIRCUIT WIRING IS NOT SHOWN,

CONTRACTOR SHALL CONNECT ITEMS TO CIRCUITS

INDICATED. EXACT ROUTING OF CONDUITS AND WIRING

SHALL BE DETERMINED BY THE CONTRACTOR IN

ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND

AS RESTRICTED BY THE ROOM SCHEDULE ON THE DRAWING.

FEEDER CONDUIT AND WIRE SIZES SHALL BE AS INDICATED

ON THE SINGLE LINE DIAGRAMS.

2. ALL CONTROL HOUSE INTERIOR RACEWAY ROUTING AND

DEVICE MOUNTING SHALL BE EXPOSED.

3. CONTRACTOR SHALL USE ONLY THOSE WIRING METHODS

ALLOWED IN THE SPECIFICATIONS.

4. A MAXIMUM OF 3 CIRCUITS SHALL BE RUN IN ONE CONDUIT.

CIRCUITS MUST BE ON SEPARATE PHASES. NO SHARED

NEUTRALS SHALL BE ALLOWED.

5. MINIMUM WIRE SIZE SHALL BE #12 AWG, MINIMUM CONDUIT

SIZE SHALL BE 3/4".

6. ALL WORK SHALL STRICTLY COMPLY WITH THE CURRENT

EDITION OF THE NATIONAL ELECTRICAL CODE.

7. DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR SHALL FIELD

SURVEY ALL DIMENSIONS AND EXISTING CONDITIONS

BEFORE PROCEEDING WITH NEW WORK. REPORT ALL

DISCREPANCIES TO CONTRACTING OFFICER.

8. CONTRACTOR SHALL COORDINATE NEW WORK WITH

EXISTING WORK AND OTHER TRADES TO AVOID

INTERFERENCES.

9. LOCATION OF NEW EQUIPMENT IS APPROXIMATE AND SHALL

BE COORDINATED IN FIELD WITH INTERFERENCES. MAINTAIN

PROPER CLEARANCES IN AVAILABLE SPACE AS REQUIRED BY

NATIONAL ELECTRICAL CODE.

10. LOCATIONS AND MOUNTING HEIGHTS OF EQUIPMENT ARE

APPROXIMATE. EXACT LOCATIONS SHALL BE COORDINATED

IN FIELD WITH CONTRACTING OFFICER.

11. ELECTRICAL EQUIPMENT LOCATIONS AND RACEWAY

ROUTINGS ARE SHOWN DIAGRAMMATICALLY AND ARE

INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT

ONLY. COORDINATE INSTALLATION OF ELECTRICAL

EQUIPMENT AND RACEWAYS WITH EXISTING SITE AND

UTILITIES IN FIELD.

12. ALL LOCATIONS OF EXISTING UNDERGROUND UTILITIES

SHOWN ON PLANS HAVE BEEN DEVELOPED FROM EXISTING

RECORD DRAWINGS AND/OR GROUND EXAMINATION OF THE

SITE. CONTRACTOR SHALL VERIFY HORIZONTAL AND

VERTICAL LOCATIONS OF ALL EXISTING UNDERGROUND

UTILITIES PRIOR TO START OF CONSTRUCTION. COORDINATE

INSTALLATION OF ELECTRICAL WORK TO AVOID

INTERFERENCES. HAND DIG IN LOCATIONS ADJACENT TO

EXISTING UTILITIES.

13. COORDINATE THE LOCATION OF THE RANGE CONTROL

SYSTEM, FIBER RACK, PA SYSTEM, AND ALL OTHER

EQUIPMENT IN EACH ELEVATED RANGE CONTROL HOUSE

WITH GOVERNMENT.

H

HANDHOLE - POLYMER COMPOSITE

CA CA CA

C C C C

HOMERUN TO PANEL - DENOTES 1"C. WITH

3#12&1#12G UNLESS OTHERWISE NOTED.

POWER PANEL IN NEMA 4X ENCLOSURE -

SURFACE MOUNT

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

PANEL 'TS6-100LC' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 60 A MAIN LUG ONLY, 10kAIC, NEMA 4X

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

RECPS - 100 YD TARGETS 20 1 1.0 01

2 20 SPARE

SPARE 20 1 0 03 0

SPARE 20 1 05

06 2 20 SPARE

SPARE 20 1 07

SPARE 20 1

09 10 2 20 SPARE

SPARE 20 1

1.0 0.0 0.0 0.0

TOTAL CONNECTED

kVA/PHASE

1.0 0.0

TOTAL CONNECTED kVA 1.0

EXISTING LOAD CENTER 'RANGE 6' SCHEDULE

120/240 V AC, 60 Hz, 1 PH, 3 WIRE, 100 A MAIN LUG ONLY, 10kAIC

EQUIPMENT SERVED

CKT BRKR kVA/PHASE

CKT

NO

CKT

NO

kVA/PHASE CKT BRKR

EQUIPMENT SERVED

TRIP POLE A B A B POLE TRIP

TENNIS BALL LAUNCHER 20 1 1.0 01

1.0

2 40 LOAD CENTER 'TS6-100C'

EXISTING 20 1 0.5 03 1.0

EXISTING 20 1 0.5 05 06 0.5 1 20

RECPS - CONTROL HOUSE (PA SYS)

EXISTING 20 1 0.5 07 08 0.5 1 20

RECPS - CONTROL HOUSE (RCS)

1.5 1.0 1.5 1.5

TOTAL CONNECTED

kVA/PHASE

3.0 2.5

TOTAL CONNECTED kVA 5.5

UNDERGROUND DATA CONDUIT

D D D D

UNDERGROUND ELECTRICAL CONDUIT

E E E E

PROVIDE CIRCUIT BREAKER IN EXISTING SPACE.

CIRCUIT BREAKER SHALL MATCH MANUFACTURER

AND AIC RATING. PANEL IS SQD QO LOAD CENTER,

10kAIC.

WAP

WIRELESS ACCESS POINT DEVICE - MOUNT

6'-0" AFG ON 2 1/4"X16 GAUGE ROUND

GALVANIZED STEEL POST, EMBEDDED

INTO 12"DIA X 2'-6" CONCRETE

FOUNDATION. EXTEND 3/4" CONDUIT WITH

CAT-6 CABLE FROM FIBER ENCLOSURE TO

POST AND EXTEND VERTICALLY UP POST

TO DEVICE.

O

O

O

O

O

O

O

O

O

O

O

O

H

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

D

D

D

D

D

D

D

D

D

D

D

D

E

H

E

E

E

E

D

H

D

D

D

D

D

H

H

H

H

T

E

D

E

E

E

C

C

C

C

C

C

C

A

C

A

C

A

C

A

C

A

C

A

C

C

A

C

C

C

A

C

A

C

C

C

A

C

A

C

C

A

C

C

A

C

C

C

A

C

A

WAP

WAP

WAP

WAP

WAP

WAP

WAP

E

E

C

A

C

A

C

A

C

A

C

C

C

C

C

C

A

H

H

H

H

H

H

H

H

H

H

H

H

WAP

D

D

D

D

D

D

D

D

D

E-101

E

LE

C

TR

IC

A

L S

IT

E

P

LA

N

E-101

GENERAL SHEET NOTES

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

TS5-100LC-1

NEMA 4X FIBER OPTIC

DATA ENCLOSURE '100-A'

E

E

E

E

E

E

E

E

E

E

E

E

E

E

D

D

D

D

D

D

D

D

D

D

D

D

C

C

C

C

C

C

C

C

C

CA

CA

CA

CA

CA

CA

CA

CA

CA

C

C

C

C

C

CA

CA

CA

CA

CA

PANEL 'TS5-100LC'

A

H

H

D

2#12&1#12G - 1"CND

12-STRAND SINGLE

MODE OSP FIBER -2"CND

TO 200A

6"X6" GALVANIZED

STEEL NEMA 3R

TROUGH

3#8&1#8G - 2"CND

12-STRAND SINGLE MODE

OSPFIBER IN 2"CND

6"X6" GALVANIZED

STEEL NEMA 3R

TROUGH

E

E

E

E

E

E

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

TO WAPS

CAT-6 CABLES - 1"CND

H

H

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

2-3" CND COMPRESSOR AIR

2-3"CND CONTROLS

2 (3#8&1#8G - 2"CND)

D

D

D

D

D

D

D

TO WAP

TO WAP

C

2 (12-STRAND SINGLE MODE

OSPFIBER IN 2"CND)

3 (3#8&1#8G - 2"CND)

3-3" CND COMPRESSED AIR

3-3"CND

CONTROLS

2 (CAT-6 CABLES - 1"CND

TS5-300LC-6

2#12&1#12G - 1"CND

3#8&1#8G - 2"CND

C

C

C

C

C

C

C

C

C

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

PANEL 'TS5-300LC'

A

E

E

E

E

E

E

E

E

E

H

E

E

E

E

E

E

E

E

E

E

2-2" DIRECT BURIED PVC

CND BETWEEN

EMPLACEMENT WALLS

6"X6" GALVANIZED STEEL

NEMA 3R TROUGH

6"X6" GALVANIZED

STEEL NEMA 3R

TROUGH

E

E

E

E

E

E

H

H

1-3" CND COMPRESSOR AIR

1-3"CND CONTROLS

C

E

E

E

E

E

E

E

E

E

E

E

C

C

C

C

C

C

C

C

C

PANEL 'TS5-200LC'

NEMA 4X FIBER OPTIC

DATA ENCLOSURE '200-A'

12-STRAND SINGLE MODE

OSP FIBER - 2"CND

E

E

E

E

D

D

D

D

D

D

D

D

D

A

TS5-200LC-6

H

H

CA

CA

CA

CA

CA

CA

CA

CA

C

C

C

C

C

CA

CA

CA

CA

CA

E

E

E

E

E

E

E

E

E

E

2-2" DIRECT BURIED PVC

CND BETWEEN

EMPLACEMENT WALLS

2#12&1#12G - 1"CND

6"X6" GALVANIZED

STEEL NEMA 3R

TROUGH

3#8&1#8G - 2"CND

6"X6" GALVANIZED

STEEL NEMA 3R

TROUGH

D

D

D

D

D

D

D

D

D

D

D

D

D

E

E

E

E

E

E

D

D

D

D

D

D

D

D

D

D

D

D

TO WAP

CAT-6 - 1"CND

H

H

1-3" CND COMPRESSOR AIR

1-3"CND CONTROLS

3#8&1#8G - 2"CND

2 (3#8&1#8G - 2"CND)

2-3"CND

CONTROLS

2-3" CND

COMPRESSOR AIR

E-401

E N

LA

R

G E

D P

LA

N

S

TA

R

G E

T E

M P

LA

C

E M

E N

T

GENERAL SHEET NOTES

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

E-401

E-401

E-401

CA

CA

CA

CA

CA

CA

CA

CA

C

C

C

C

C

C

C

C

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

E

E

E

E

E

H

H

E

E

E

E

E

E

E

D

D

D

D

D

D

D

TS6-100LC-1

A

PANEL 'TS6-100LC'

POLE MOUNTED

SPEAKER (TYPICAL OF 5)

D

D

E

E

E

E

E

E

E

E

E

D

D

D

D

D

D

D

D

D

D

D

D

E

E

E

E

D

D

D

D

D

D

D

D

E

E

E

E

E

E

E

2#10&1#10G - 1"CND

3#8&1#8G - 2"CND

1-3"CND

COMPRESSED AIR

1-3"CND

CONTROLS

2/C#16 - 2"CND

12-STRAND

SINGLE MODE OSP

FIBER - 2"CND

NEMA 4X FIBER OPTIC

DATA ENCLOSURE '200-A'

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

12-STRAND

SINGLE MODE OSP

FIBER - 2"CND

D

D

D

D

TO WAP

CAT-6 CABLES - 1"CND

D

D

D

D

(2#10&1#10G AND

3#8&1#8G) - 2"CND

D

D

D

D

D

D

D

D

D

D

D

D

D

D

2/C#12-2"C

AIR COMPRESSOR (5 HP)

ON CONCRETE FOUNDATION

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

600V/30A/3P

IN NEMA 3R

ENCLOSURE

STEEL CHANNEL SUPPORT

RACK WITH REGULATORS.

STUB CONDUIT(S) UP AT

COMPRESSED AIR

MANIFOLD LOCATION.

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

C

C

C

C

C

C

C

C

C

C

C

C

C

C

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EXISTING RANGE 6 LOAD CENTER

EXISTING ELEVATED

RANGE CONTROL HOUSE

3 4

TO RANGE 6 100YD

TARGETS

TO RANGE 6 100YD

TARGETS

1-3"CND

COMPRESSED AIR

1-3"CND

CONTROLS

H

H

H

H

(2#10&1#10G AND

3#8&1#8G) - 2"CND

12-STRAND

SINGLE MODE OSP

FIBER - 2"CND

W

A

P

D

D

D

D

D

D

D

D

D

CAT-6 CABLES - 1"CND

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

2/C#12-2"C

2/C#12-2"C

(2#10&1#10G AND

3#8&1#8G) - 2"CND

E-402

E N

LA

R

G E

D P

LA

N

S

R A

N G

E

GENERAL SHEET NOTES

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

E-402

E-402

SHEET KEY NOTES

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

E-501

E

LE

C

TR

IC

A

L D

E

TA

IL

S

A N

D W

IR

IN

G D

IA

G

R A

M

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

E-502

E

LE

C

TR

IC

A

L D

E

TA

IL

S

A N

D W

IR

IN

G D

IA

G

R A

M

File details come from the government source that posted it.