This document outlines water quality testing requirements and standards for a residential drinking water well project. The contractor shall drill a well to an estimated depth of 220 feet on fee land in Snoqualmie, Washington. Testing will include inorganic chemicals, physical characteristics, and bacteria as specified by Washington regulations. Inorganic chemicals such as arsenic, beryllium, and nitrates must meet Primary Maximum Contaminant Levels. Secondary standards also apply to characteristics including chloride, fluoride, iron, manganese, and pH levels. The contractor is responsible for any required permits and will conduct well development, test pumping, and water sampling. The opportunity was issued by the Department of Health and Human Services Indian Health Service under solicitation number 75H70124Q00013.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chemicals required to be tested and corresponding Maximum Contaminant Limits (MCLs), modified from the Washington Administrative Code (WAC) Section 246-291-171. Note: A bacterial test is also required.

Table 1

INORGANIC CHEMICAL CHARACTERISTICS

Substance Primary MCLs (mg/L)

Antimony 0.006 Arsenic 0.01 Barium 2.0 Beryllium 0.004 Cadmium 0.005 Chromium 0.1 Cyanide 0.2 Fluoride 4.0 Mercury 0.002 Nickel 0.1 Nitrate (as N) 10.0 Nitrite (as N) 1.0 Selenium (Se) 0.05 Sodium (Na) * Thallium 0.002

Substance Secondary MCLs (mg/L)

250.0

2.0 0.3

0.05 0.1 250.0

Chloride (Cl) Copper (Cu)** Fluoride (F) Iron (Fe) Lead (Pb)** Manganese (Mn) Silver (Ag) Sulfate (SO4) Zinc (Zn) 5.0

*Although there is not an established MCL for sodium, there is enough public health significance connected with sodium levels to require inclusion in inorganic chemical and physical monitoring.

**MCLG (Maximum Contaminant Level Goal), as set by the Washington State Department of Health Lead and Copper Rule.

1.3

0.015

Table 2

PHYSICAL CHARACTERISTICS

Substance Primary MCL Turbidity 1.0 NTU

Substance Secondary MCLs Color Hardness Specific Conductivity Total Dissolved Solids (TDS)

15 Color Units None established 700 umhos/cm 500 mg/L pH

Alkalinity (as CaCO3)

6.5 – 8.5 None established

Table 1
Table 2