7 - SOW Greenhouse.pdf

PDF 183 KB Posted

Attached to
FCC Lompoc- Free Standing Galvanized Steel Frame Greenhouse Federal contract opportunity
Solicitation number
15B61724Q00000010
Issued by
Department of Justice Bureau of Prisons Federal Correctional Complex Lompoc

About this file

This statement of work outlines the specifications for a free-standing galvanized steel frame greenhouse to be provided to the Federal Correctional Complex in Lompoc, California. The greenhouse is to be 16 feet wide, 30 feet long, and 6 feet in sidewall height, constructed of galvanized 14-gauge steel with 8mm clear twin wall polycarbonate glazing and roofing panels. Additional specifications include truss and column spacing, doors, fans, shutters, plumbing, irrigation, heating, shading, controls, and equipment. Delivery is required to the facility between 7:30am and 2:00pm Monday through Friday, excluding federal holidays. The related solicitation is a 100% total small business set-aside for the greenhouse with a deadline of January 17, 2024. The required North American Industry Classification System code is 332510 and small business size standard is $750,000. Bidders must ensure their SAM registration reflects eligibility as a small business.

View the file

Other files for this federal contract opportunity

Other files attached to FCC Lompoc- Free Standing Galvanized Steel Frame Greenhouse, newest first.
File Type Posted
Solicitation 15B61724Q00000010.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FSA GREENHOUSE

FCC LOMPOC - B&F PROJECT # 24Z6AS7

1. SPECIFICATIONS:

A. INTRODUCTION

The Federal Bureau of Prisons (FBOP), Federal Correctional Complex in Lompoc, California intends to make a single award to a small-business who can provide a free-standing galvanized steel frame greenhouse structure complete with the following product specifications. Bids must include an attachment of specifications of an equal or better product from the specifications listed below.

B. PRODUCT SPECIFICATIONS

• 16’ wide x 30’ long x 6’ Sidewalls Galvanized 14-gauge Steel Frame Greenhouse.

• 2” x 2” Square Galvanized 14-gauge Steel Frame.

• Eave Glazing: 8mm clear twin wall no drip polycarbonate. (10 yr. warranty)

• Roof Glazing: 8mm clear twin wall no drip polycarbonate panels. (10 yr. warranty)

• 6’ Column and Truss Spacing.

• 8mm Twin Wall Polycarbonate Covering.

• Aluminum Extrusions.

• 42" x 6' - 8" ADA Compliant Single Swing Door.

• 2- 18” End Gables Framed For a 3 x 10 Evaporative Cooling System

• 2 -18" Quietaire Industrial Box Exhaust Fan 1/4hp: 3490 cfm ea. @ .05 SP 110V

• Aluminum Shutters.

• Thermostat Controls.

• 4- 4’x 6’ Portable Work Benches.

• Complete Plumbing Irrigation System with Mist and Fertilizer Injector 12 GPM max.

• Hanging Basket Rail System.

• Engineered Drawings and specs.

• Natural Gas Heating System 60,000 BTU Modine Model HD60A 80% thermal efficiency

• Included Shade Cloth covering with 51% Shading Factor.

• Emergency Lighting / Exit Signs / Fire Extinguisher.

• 3’ x 10’ Stainless Steel Evaporative Cooling System.

• Bartlett Instrument Company Climate Boss Automatic Temperature Control.

• Wind and Snow Loads Specs to meet Santa Barabra County, Ca Requirements.

C. DELIVERY OF MATERIALS:

Deliveries shall be directly shipped to the BOP (3600 GUARD ROAD LOMPOC, CA 93436) between the hours of 7:30 a.m.

to 2:00 p.m., Monday through Friday, excluding Federal Holidays.

The vendor shall not use the institution entry/driveway for the loading, unloading, or storage of any materials and equipment. The vendor will not impede/block the driveway at any time during or after the work shift.

D. ADDITIONAL CONSIDERATIONS:

Vendors will NOT be allowed to bring cell phones, cameras, or two-way pagers into FCC Lompoc.

Vendors / Delivery Personnel will be permitted to wear jeans in the institution, however, green, khaki-color or blaze orange clothing will not be allowed. The clothes will be proper and suitable for the services that are being provided.

Federal smoking policy on Federal property states that smoking is only allowed in designated areas. This policy will be strictly enforced.

File details come from the government source that posted it. Updated .