7-10 Exhibit I Spec Sheet IHDR.pdf
PDF 61 KB Posted
- Attached to
- Deep Ellum Artwork Panels
- Solicitation number
- 2095793
- Issued by
- Dallas County, Texas
About this file
This is a specification sheet for Solicitation No. P-2095793 issued by the Dallas Area Rapid Transit Authority (DART) to procure replacement artwork panels for the Deep Ellum Rail Station. The project involves the production and delivery of 36 art panels measuring 47.5 inches by 82 inches, constructed from Aluminum Composite Material (ACM) with printed artwork applied via 3M Polyvinyl Chloride (PVC) and protected by an anti-graffiti film overlay. The panels are designed to replace worn and weathered original artwork at the station, with pre-drilled holes to match existing bolt locations for installation by DART mechanics. The winning bidder will receive the original artwork in Photoshop format via thumb drive. All materials and workmanship are warranted for three years against peeling, fading, and cracking. The finished product shall be delivered to DART's location at 3021 Oak Lane, Dallas, Texas 75226, with Peter Dickenscheid designated as the contact for delivery coordination.
Packaging requirements specify that all 36 panels must be packaged according to industry best practices to prevent damage during shipment, with containers designed in modular fashion to fit standard pallet sizes without overhang. Packaging exteriors must include panel descriptions, location designations, and manufacturer identification, with packing slips containing the DART purchase order number and part specifications. Strapping shall be vertically aligned with proper tension settings to ensure load containment. DART reserves the right to inspect the finished product prior to final acceptance. The project is not federally funded, indicating local funding sources support this initiative to restore the Deep Ellum Station to its original design aesthetic.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation No. P-2095793
DART Form 33I Page 1 of 1 Exhibit I
Dallas Area Rapid Transit Authority
EXHIBIT I
SPECIFICATIONS
DEEP ELLUM RAIL STATION ARTWORK
Purpose
The purpose of this is to purchase new art panels to replace the worn artwork at Deep Ellum Station. The art panels have worn and weathered over time, and it is the desire of the Agency to return the station to it’s original design. This is not federally funded.
Description
1. 36 Art Panels with printed artwork applied and Anti-Graffiti film to be placed over the artwork to protect it from vandalism. Holes will be pre-drilled matching the existing panels so that DART mechanics can install them once received.
1 Work Items
1. Production of Thirty-six art panels for outdoor mural on 47.5 inch by 82-inch ACM (Aluminum Composite Material) with Artwork printed on 3M Polyvinyl Chloride (PVC) applied to the ACM panels. An additional layer of Anti-Graffiti film to be applied over the panel after artwork is placed for protection from vandalism. Holes to be drilled into the panels to match previously installed panels bolt locations.
2. Material and workmanship shall be warranted for 3 years from peeling, fading, cracking.
a. Artwork will be supplied to the winning bidder in the form of a thumb drive containing the original artwork in a Photoshop format.
Verification
1. DART reserves the right to inspect the finished product before delivery and prior to final acceptance.
Packaging
1. Product shall be packaged according to best industry practice to prevent damage. The packing slip shall include DART purchase order number, manufacturer name and part description. The packaging exterior (e.g., individual part bag, box, etc.) shall include description, panel location and manufacturer’s name.
2. When the part size permits, containers should be designed in a modular fashion to fit on standard pallet sizes. The pallet must be designed to accommodate the part(s) length and weight, keeping the material within the confines of the pallet (i.e., material shall not overhang the footprint dimensions of the pallet.) Size carton(s) modularly to the pallet to eliminate voids and minimize shifting of packages on pallets.
3. Use only vertically aligned strapping.
4. Plastic and metal banding must be applied using proper tension settings. Excessive tension can lead to container failure and poor load containment, as well as pallet failure.
5. Product shall be packaged to provide maximum protection against:
a. Abrasion
b. Thermal
c. Other types of damage that can occur during shipment
2 Delivery
The mural on porcelain tile shall be delivered to Dallas Area Rapid Transit at 3021 Oak Lane., Dallas, Tx.75226.
Contact Peter Dickenscheid at (214) 878-0201 when material is delivered.