Scope of Work.pdf
PDF 65 KB Posted
- Solicitation number
- 6973GH-19-R-00221
About this file
Scope of Work (pdf)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Experience Information Form.pdf | ||
| SIR 6973GH-19-R-00221 Final.pdf | ||
| Wage Determination.pdf | ||
| Technical Specifications.pdf | ||
| Contractor's Release Form DOT F 4220.4.doc | DOC document | |
| Construction Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scope of Work Holly Springs VOR (HLI) Holly Springs, MS VOR Roof Refurbishment
JCN: 1505562
03/15/2019
The following is the proposed scope of work for the above referenced project:
Exterior:
• Remove the existing teepee and monitor antennas.
• Replace existing monitor brackets with new, heavy-duty and adjustable brackets.
• Remove the VOR equipment and store until ready for re-install.
• Remove ballast, counterpoise, and existing membrane down to wood decking.
• Rotten portions of the wooden decking will need to be replaced with matching wood planks.
• Install vapor barrier over decking.
• Install new copper mesh counterpoise.
• Install nailers.
• Install new 5/8” Dens Deck roofing board between perimeter and teepee base circle at building center using stainless steel screws and plastic washers.
• Install new PVC membrane roof.
• Install new, plastic, perimeter flashing and termination bar, and ground flashing with continuous
#6 wire loop around entire counterpoise.
• Repair rotted sections of soffit.
• The underside of the roof to be sanded, primed, and repainted to match the existing color.
• Adjust monitor brackets and ground to #6 wire loop.
• Install VOR equipment, refurbished teepee, and monitor antennas.
• Install flashing at teepee base and VOR antenna pedestals.
• Install walkways pads from ladder bracket to teepee, around the teepee, and at each monitor antenna.
• Install ladder supports and safety sign.
Interior:
• Replace approximately 100 sq. ft. of ceiling tiles due to water damage.
• Inside and above the drop ceiling, approximately 100 sq. ft. of the ceiling panels to be replaced and the area treated for mold/mildew.
File details come from the government source that posted it.