Perkinsville
MARKS RO,
r m
" 0
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
EASTERN SERVICE AREA
REMOTE CENTER AIR/GROUND
COMMUNICATIONS (RCAG) FACILITY
TOWER REPLACEMENT AND UPGRADES
ROCHESTER, NY CROC)
DRAWING LIST
DRAWING TITLE
COVER AND INDEX SHEET
LEGEND
GENERAL NOTES
!SAMAN RD,
RCAG
SITE
VICINITY MAP
06/25/2018 CONSTRUCTION, WR •17187 <EKS)
H
I -, G s i 12i1· f.
. t'~
F
E
D
C
1400222 03/12/2018
DRAWING NUMBER
ROC-1400222-G001
ROC-1400222-G002
ROC-1400222-G003
ROC-1400222-D001
ROC-1400222-C001
ROC-1400222-S001
ROC-1400222-E001
ROC-1400222-E002
ROC-1400222-E003
ROC-1400222-E004
EXISTING SITE PLAN DEMOLITION
PROPOSED ANTENNA TOWER LAYOUT PLAN
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE ,PVD B
ROC-1400222-EOOS
ROC-1400222-Q001
30' HT. GENERIC TOWER ELEVATION AND STAIR PLAN
SITE GROUNDING DETAILS SHEET 1 OF 2
SITE GROUNDING DETAILS SHEET 2 OF 2
SHELTER JUNCTION BOX DETAILS
ANTENNA PLATFORM JUNCTION BOX AND
GROUND BAR DETAILS
COAX CABLE INSTALLATION
EQUIPMENT ROOM LAYOUT
4 3
DEPARTMENT OF TRANSPORTATION
FEDERAL A VIA TI ON ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
COVER AND INDEX SHEET
ROCHESTER GREATER ROCHESTER INT'L AIRPORT
REVIEWED BY SUBMITTED BY () n
J. TIMONY~~\YML(, ~r-
PROJECT ENGINEER MGR: ENGINEERING CENTER
NY
DESIGNED ISSUED BY DATE JCN
DRAWN JT ENGINEERING SERVICES >--DR-AW-ING~~=~1~2=51~2=01=8 --~1~40=02.=R~=,~
CHECKED EKS COMMUNICATIONS ROC-1400222-GOOl
2 1 , ------------------- ---- ----------"·----- ------------------------------------~ ------ __ DRAWING PRODUCED,.ON __ AEA _RO_MlCROSTA!_!ON_srSlEM!
C
" C a_
~q N~ 0':7
ON
N oo
ON
" ' -~ <.;N O' " <O
H
G
F
E
D
C
B
A
A A-G
AGL
ALS
AN!
ADA
ARP
AWG
AWOS
B/U
BGL
BLD
BSCU
C
CE/CET
CFW
CND
co
COTR
CVPS
DEB
DIA
DISC
DIM
OME
OME CO
DOT
OPST
OPU
OU
OVOR
OWG
E/G
EES
EL <ELEV)
EMT
EOR
FAA
FBO
FDN
FHA
FOO
FS (F.S.)
FT
GA
GALV
GFCI
GFM
GND
GP
GRSC
HS(H.S.)
HV
HVAC
!LS
IN
INSUL
KV
KVA
LCU
LHA
LIR
LOC
MALS
MASLR
MAX
MB
MG
MM
MP
MS
MSL
MUTCO
N N/A
NAS
NBP
NDB
NEC
NOTAM
NS(N.S.)
NWS
OB
ODALS
OFA
OREIL
p
PAPI
PNL
PR
PRIM
R/W
RAIL
RADAR
RCAG
RCO
RE
RECEPT
REIL
REL
REQ
RF
RMMS
RMS
RR
RRCS
RSA
RTR
s
SA
SCH
SEC
SEC LT
SMO
SPD
SPST
ss
SSC
STA
T T/W
TACAN
ABBREVIATIONS
AMP
AIR TO GROUND
ABOVE GROUND/GRADE LEVEL
APPROACH LIGHT SYSTEM
NAS IMPLEMENTATION (FAA)
AIR OPERATIONS AREA
AIRPORT REFERENCE POINT
AMERICAN WIRE GAUGE
AUTOMATED WEATHER OBSERVATION SYSTEM CNWSl
BACKUP
BELOW GROUND/GRADE LEVEL
BUILDING
BARE SOLID COPPER
CONTROL
CONSTRUCTION ENGINEER/CIVIL ENGINEERING TECHNICIAN CTSSC)
CENTERFIELD WIND
CONDUIT (DUCT)
CONTRACTING OFFICER <FAA)
CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE (FAA)
CENTRAL VERMONT PUBLIC SERVICE CORPORATION
DIRECT EARTH BURIAL
DIAMETER
DISCONNECT
DIMENSION
DISTANCE MEASURING EQUIPMENT
DME CORPORATION
DEPARTMENT OF TRANSPORTATION
DOUBLE POLE, SINGLE THROW
DATA PROCESSING UNIT
DISTRIBUTION UNIT
DOPPLER VOR
DRAWING
ENGINE GENERATOR
EARTH ELECTRODE SYSTEM
ELEVATION
ELECTRIC METALLIC TUBING
END OF RUNWAY
FEDERAL AVIATION ADMINISTRATION (US DOT)
FIXED BASE OPERATOR
FOUNDATION
FEDERAL HIGHWAY ADMINISTRATION (US DOT)
FOREIGN OBJECT DEBRIS
FAR SIDE
FEET
GENERAL AVIATION
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GOVERNMENT FURNISHED MATERIAL
GROUND
GENERAL PURPOSE
GALVANIZED RIGID STEEL CONDUIT
HIGH STRENGTH
HIGH VOLTAGE
HEATING, VENTILATION, AND AIR CONDITIONING
INSTRUMENT LANDING SYSTEM
INCH
INSULATED
KILOVOLT
KILOVOLT AMPERE
LINK CONTROL UNIT <RMS)
LAMP HOUSING ASSEMBLY (PAPI, VASI)
LOW IMPACT RESISTANCE
LOCALIZER (!LS)
MEDIUM INTENSITY APPROACH LIGHTING SYSTEM
MALS WITH RUNWAY ALIGNMENT INDICATOR LIGHTS (MALS-RA!Ll
MAXIMUM
MACHINE BOLT
MAST-ON-GROUND (L!Rl MIDDLE MARKER C!LSl
MULTI-POINT <GROUND)
MAST-ON-STAND CL!R)
MEAN SEA LEVEL
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (FHA)
NEUTRAL
NOT APPLICABLE
NATIONAL AIRSPACE SYSTEM
NEW BEDFORD PANORAMICS CORPORATION
NON-DIRECTIONAL BEACON
NATIONAL ELECTRIC CODE
NOTICE TO AIRMEN
NEAR SIDE
NATIONAL WEATHER SERVICE
OBSTRUCTION
OMNI-DIRECTIONAL APPROACH LIGHT SYSTEM
OBJECT FREE AREA
OMNI-DIRECTIONAL RUNWAY END IDENTIFIER LIGHTS
POWER
PRECISION APPROACH PATH INDICATOR
PANEL
PAIR
PRIMARY
RUNWAY
RUNWAY ALIGNMENT INDICATOR LIGHTS
RADIO DETECTION AND RANGING
REMOTE CENTER AIR TO GROUND COMMUNICATIONS
REMOTE COMMUNICATIONS OUTLET
RESIDENT ENGINEER (FAA/TSSC)
RECEPTACLE
RUNWAY END IDENTIFIER LIGHTS
RUNWAY EDGE LIGHTS
REQUIRED
RADIO FREQUENCY
REMOTE MAINTENANCE MONITORING SYSTEM
REMOTE MONITORING SUBSYSTEM
REMOTE RADIO
REMOTE RADIO CONTROL SYSTEM
RUNWAY SAFETY AREA
REMOTE TRANSMITTER/RECEIVER
SIGNAL
SUBCONTRACTS ADMINISTRATOR (TSSC)
SCHEDULE
SECONDARY
SECURITY LIGHT
SYSTEM MANAGEMENT OFFICE (FAA)
SURGE PROTECTION DEVICE
SINGLE POLE, SINGLE THROW
STAINLESS STEEL
SYSTEM SUPPORT CENTER (FAA)
STATION
TELEPHONE
TAXIWAY
TACTICAL AIR NAVIGATION
I 7 I
TEL
TELCO
TH
TPST
TSA
TSSC
TVSS
TYP
UPS
us V
VASI
VHF
VOR
VORTAC
WI
WILCOX
WPN ws
XFMR
XMTR
TAXIWAY EDGE LIGHTS
TELEPHONE COMPANY
THRESHOLD
TRIPLE POLE, SINGLE THROW
TAXIWAY SAFETY AREA
FAA TECHNICAL SUPPORT SERVICE CONTRACT
TRANSIENT VOLTAGE SURGE PROTECTION
TYPICAL
UNINTERRUPTIBLE POWER SOURCE/SUPPLY
UNITED STATES
VOLT
VISUAL APPROACH SLOPE INDICATOR
VERY HIGH FREQUENCY
VHF OMNI-DIRECTIONAL RANGE
VHF OMNI-DIRECTIONAL RANGE WITH TACAN
WITH
WILCOX CORPORATION (THALES)
WILCOX PART NUMBER (WILCOX CO)
WIND SOCK
TRANSFORMER
TRANSMITTER
(PARSONS)
4 3
+ 4 I 3
2 1
SYMBOLS LEGEND
SUBTITLE REFERENCE
REFERENCE NUMBER/LETTER
(PLAN, DETAIL/ ELEVATION, SECTION) -
," X''. XXXXXXXXXXX
\_XXX~' SCALE: X·XXX
l '-scALE
SHEET NUMBER(S) WHERE CALLOUT(Sl TO PLAN, DETAIL, ELEVATION OR SECTION IS/ARE LOCATED
ELEVATION CALLOUT REFERENCE
/ x''\..
V/;_"fXY
ELEVATION REFERENCE LETTER
lEET NUMBER WHERE
ELEVATION IS LOCATED
SECTION CALLOUT REFERENCE
SECTION REFERENCE LETTER
• XX I
SHEET NUMBER WHERE
SECTION IS LOCATED
DETAIL CALLOUT REFERENCE
,- X'/', J I
I XXYX'
X "/'.;, DETAIL REFERENCE NUMBER
lHEET NUMBER WHERE
DETAIL IS LOCATED
DRAWING PREFIXES
CXXX - CIVIL
EXXX - ELECTRICAL/ELECTRONIC
GXXX - GENERAL
axxx - EQUIPMENT
SXXX - STRUCTURAL
06/25/2018 CONSTRUCTION, WR •17187 (EKS) 1400222 03/12/2018
REV
ATO
APPROVED
DATE DESCRIPTION JCN
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
REDLINE
DATE
- TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND
LEGEND
UPGRADES
Af'VD
AREA
H
G
F
E
D
C
B i ir.
gi s, "' 0
ROCHESTER
REVlEWEO BY
SUBMITTED BY
GREATER ROCHESTER INT'L AIRPORT _,, /, _.---;;:-' NY 1·
APPROVED BY ' / /, ,' / ' /I C
_,("" -,__,_ / ~ 'i""" A ~ J. r,MoNY e(rA Uvi~ v M.GORDON ~
PROJECT ENGINEER MGR: ENGINEERING CENTER
ISSUED BY DATE 06/25/2018 IJCN 1400222
t---+---+DccRcccAW""N,------~JT ENGINEERING SERVICES "'o=RA=w=JNG~NO~--~-----=R=-"'Ev
EKS COMMUNICATIONS
DESIGNED
CHECKED ROC-1400222-G002
N N N g w u C , " • J
H
G
F
E
D
C
B
A
8 7
GENERAL NOTES:
1. THIS DRAWING PACKAGE INDICATES WORK REQUIRED FOR THE TOWER REPLACEMENT
AND UPGRADES AT THE REMOTE CENTER AIR-GROUND COMMUNICATIONS (RCAG)
FACILITY IN ROCHESTER, NY.
2. SUBCONTRACTOR ACCESS ROUTES, STAGING AREAS, AND REGIONAL EMPLOYEE
PARKING AREAS SHALL BE APPROVED IN ADVANCE BY THE FAA.
3. WORK ASSOCIATED WITH THE RCAG FACILITY MAY REQUIRE A SHUTDOWN.
COORDINATE ALL RCAG RELATED ACTIVITIES AND REQUIRED SHUTDOWNS WITH
THE FAA SSC AT LEAST 48 HOURS IN ADVANCE.
4. THE SUBCONTRACTOR SHALL MAINTAIN A CLEAN WORK SITE. EQUIPMENT AND
MATERIAL SHALL BE REMOVED FROM THE WORK SITE AT THE END OF EACH
WORK SHIFT. THE SUBCONTRACTOR SHALL KEEP THE WORK SITE FREE OF
CONSTRUCTION DEBRIS.
5. THE SUBCONTRACTOR SHALL STRICTLY COMPLY WITH ALL OSHA REGULATIONS
AT ALL TIMES. THE RE RESERVES THE RIGHT TO SUSPEND THE PROJECT
SHOULD HE OR SHE DETERMINE THAT AN UNSAFE CONDITION EXISTS.
6. THE SUBCONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIAL UNLESS
OTHERWISE INDICATED. THE SUBCONTRACTOR SHALL PROVIDE ALL LABOR,
EQUIPMENT, AND REQUIRED TEMPORARY POWER UNLESS OTHERWISE INDICATED.
THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS.
7. THE SUBCONTRACTOR SHALL LEGALLY DISPOSE OF ALL MATERIAL AND
EQUIPMENT NOT RETURNED TO OR RETAINED BY THE FAA.
8. IF CONDITIONS ARE DIFFERENT THAN THOSE INDICATED IN THE DRAWINGS
OR SPECIFICATIONS, THE SUBCONTRACTOR SHALL CONTACT THE SUBCONTRACT
ADMINISTRATOR (SA) PRIOR TO PROCEEDING WITH CONSTRUCTION.
SITE WORK:
1. CONTRACTOR SHALL PERFORM A "GROUND PENETRATING RADAR" STUDY
WITHIN ALL AREAS TO BE EXCAVATED IN ORDER TO LOCATE AND IDENTIFY
ANY AND ALL UNDERGROUND UTILITY, CABLES, DUCTS, ETC. PRIOR TO
ANY EXCAVATION ACTIVITY.
2. ALL DIMENSIONS, ELEVATIONS, CONTOURS, AND HEIGHTS INDICATED ARE
APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE SUBCONTRACTOR.
3. EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. OTHER UTILITIES
MAY NOT BE SHOWN. THE SUBCONTRACTOR SHALL FIELD LOCATE ALL SUBSURFACE
UTILITIES PRIOR TO ANY EXCAVATION. FORTY-EIGHT (48) HOUR (MINIMUM)
NOTICE BY THE CONTRACTOR TO THE RE, AND THE FAA SSC IS REQUIRED
FOR ALL UTILITY MARKING AND/OR FACILITY SHUTDOWNS.
4. THE SUBCONTRACTOR SHALL BE PREPARED TO IMMEDIATELY REPAIR ANY
UTILITIES DAMAGED DURING EXCAVATION OPERATIONS AND SHALL CONDUCT
ALL SUCH REPAIRS AT SUBCONTRACTOR EXPENSE.
5. THE EXISTING GRADE SURROUNDING FOUNDATION OR TRENCH WORK SHALL
BE STABILIZED AND PROTECTED FROM EROSION DURING AND IMMEDIATELY
AFTER COMPLETION OF THE FOUNDATION OR CONDUIT INSTALLATION AND
ALL REQUIRED EXCAVATION AND BACKFILL.
6. ALL DISTURBED AREAS SHALL BE RESTORED TO PRIOR CONDITION AT A
MINIMUM. FINAL CONDITION SHALL BE APPROVED BY THE FAA.
7. ALL EXCAVATIONS WITHIN 10' OF RCAG SHELTER SHALL BE PERFORMED
BY HAND.
ELECTRICAL WORK:
1. ALL ELECTRICAL WORK SHALL CONFORM TO FAA-C-1217G AND FAA-C-1391L
SPECIFICATIONS AND IN NO CASE SHALL VIOLATE THE NATIONAL ELECTRIC
CODE CNFPA 70, NEC).
2. THE SUBCONTRACTOR SHALL MAKE ALL POWER AND GROUND TERMINATIONS. COAX
CABLE AND CONNECTORS PROVIDED AND INSTALLED BY SUBCONTRACTOR. ALL
FLEXIBLE LIQUIDTIGHT CONDUIT SHALL BE PLASTIC PVC LIQUID TIGHT TYPE.
ALL CONTROL/DATA CABLE SHALL BE TWISTED, INDIVIDUALLY SHIELDED.
3. ALL CIRCUITS SHALL HAVE INDIVIDUAL NEUTRAL AND GROUNDING CONDUCTORS;
NO SHARED NEUTRALS OR GROUNDS WILL BE PERMITTED.
4. NEUTRAL CONDUCTORS SHALL REMAIN ISOLATED FROM GROUND IN ALL LOCATIONS
EXCEPT AT POWER SERVICE ENTRANCE. WHERE POSSIBLE, POWER CABLES AND
CONTROL/DATA CABLES SHALL RUN IN CONDUIT INDEPENDENT OF EACH OTHER.
SEPARATE POWER AND CONTROL/DATA CABLES IN COMMON HANDHOLES, ENCLOSURES,
AND SHELTER SQUARE DUCT WIREWAY.
5. ALL CABLES SHALL BE PROPERLY COLOR CODED AND PERMANENTLY LABELED AT
EACH END AND IN EACH HANDHOLE. ALL CABLES IN HANDHOLES SHALL BE LOOPED
AROUND SEVERAL TIMES.
6 5
TOWER DESIGN, FABRICATION, AND INSTALLATION:
1. THE TOWER PLATFORM FURNISHED BY THE SUBCONTRACTOR SHALL BE COMPLETE IN
ACCORDANCE WITH ALL SPECIFICATION REQUIREMENTS INCLUDING STRUCTURAL
BOLTS, AND ALL OTHER HARDWARE ESSENTIAL FOR ERECTING THE TOWER. THE
SUBCONTRACTOR SHALL PROVIDE ALL MATERIALS, SUPPLIES, EQUIPMENT, AND
SERVICES NECESSARY TO DESIGN, FABRICATE, DELIVER, AND ERECT EACH TOWER.
2. THE TOWER PLATFORM SHALL BE SELF-SUPPORTING TYPE WITH A PLATFORM AT THE
TOP FOR MOUNTING AND SERVICING ANTENNAS. THE TOWER SHALL BE
DESIGNED TO BE SHIPPED KNOCKED DOWN AND TO BE ERECTED IN THE
FIELD USING STRUCTURAL BOLTS ONLY.
3. THE TOWER PLATFORM SHALL PERMIT INSTALLATION OF V/V DOUBLE STACK
ANTENNAS. ACCESS TO THE PLATFORM SHALL BE EQUIPPED WITH AN OSHA
APPROVED WALK UP STAIRWAY. THE PLATFORM SHALL BE CONSTRUCTED OF
ANGLE FRAMING MEMBERS AND THE FLOOR SHALL BE FABRICATED FROM BAR
TYPE GRATING. THE FLOOR SHALL BE SECURED TO THE FRAMING. THE
PLATFORM SHALL BE PROVIDED WITH A GUARD RAIL SYSTEM, COMPOSED OF
VERTICAL POSTS WITH TOP AND INTERMEDIATE RAIL COMPONENTS LOCATED
42 INCHES AND 21 INCHES, RESPECTIVELY, ABOVE THE PLATFORM FLOOR.
A 4 INCH HIGH TOE-BOARD SHALL BE ATTACHED TO THE BASE OF THE RAIL
POST. THE PERIMETER FRAMING MEMBERS SHALL SUPPORT THE RAIL AS WELL
AS THE REQUIRED ANTENNA MOUNTING BRACKETS.
4. THE TOWERS SHALL BE DESIGNED FOR A WIND LOAD PER ANSI STANDARD
TIA-222-H TO SUPPORT THE PLATFORM WITH A 42 INCH HANDRAIL PLUS
THE FOLLOWING:
A. SIXTEEN (16) UHF/VHF DOUBLE STACK ANTENNAS, MOUNTED AROUND THE
PLATFORM HANDRAIL.
B. ONE JUNCTION BOX (9 SQUARE FEET) MOUNTED ON THE PLATFORM
HANDRAIL.
C. THIRTY TWO ANTENNA CABLES, EACH 1 INCH DIAMETER, (LMR-900)
ROUTED UP ONE SIDE OF THE TOWER.
5. ALL BOLTS FOR STRUCTURAL JOINTS SHALL BE HIGH STRENGTH PER
ASTM A-325. ALL NUTS SHALL HAVE A JAM NUT BENEATH THE FULL
NUT. SELF-LOCKING NUTS INTENDED FOR USE ON EXTERIOR BOLTED
CONNECTIONS MAY BE SUBMITTED FOR APPROVAL.
6. THE SUBCONTRACTOR SHALL SUBMIT DETAILED DESIGN, FABRICATION, AND
ERECTION DRAWINGS FOR THE TOWERS. THE DRAWINGS AND CALCULATIONS
SHALL BE IN ACCORDANCE WITH ESTABLISHED ENGINEERING PRACTICE AND
THE AC!, AISC, AISI, OR EIA SPECIFICATIONS AS APPLICABLE. DESIGN
DRAWINGS SHALL SHOW CONTROL DIMENSIONS, MEMBER SIZES, AND OTHER
DETAILS NECESSARY FOR THE DEVELOPMENT OF SHOP AND ERECTION
DRAWINGS. ERECTION DRAWINGS SHALL INDICATE ANCHOR BOLTS, MEMBER
LOCATION, BOLT SIZES AND NUMBER AND ALL OTHER INFORMATION TO
CLEARLY DEPICT REQUIREMENTS FOR FIELD ERECTION. A PARTS LIST
SHOWING THE MEMBER NUMBER, SIZE, AND LENGTH SHALL BE PROVIDED
IN THE ERECTION DRAWINGS.
7. TOWER FABRICATION SHALL BE IN ACCORDANCE WITH THE AISC AND THE
SPECIFICATIONS. MEMBERS SHALL HAVE NO SHARP EDGES WHICH WILL BE
HAZARDOUS DURING HANDLING OR OTHER IRREGULARITIES WHICH WILL
INTERFERE WITH ERECTION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE
FOR CORRECTIONS OF ALL FABRICATION ERRORS AND CORRECT FITTING
OF THE FABRICATED MEMBERS. EACH SEPARATE MEMBER, EXCEPT BOLTS,
WASHERS, AND SIMILAR ITEMS SHALL BE CLEARLY MARKED AS PER THE
ERECTION DRAWINGS.
8. TOWER PLATFORM SHALL BE FULLY SERRATED BAR GRATED TYPE 19-W2 OR EQUAL,
9. FINAL TOWER DESIGN SHALL BE 100% STRUCTURALLY ANALYZED AND STAMPED
APPROVED BY A LICENSED PROFESSIONAL ENGINEER WITHIN THE CONTINENTAL
U.S. THE TOWER SHALL BE ANALYZED IN ITS ENTIRETY, INCLUDING, BUT
NOT LIMITED TO; PLATFORM, ANTENNA MOUNTS, JUNCTION BOXES, WAVEGUIDE
LADDER AND CABLES, ANTENNAS, STAIRWAY, AND CONDUITS, INCLUSIVE OF ALL
APPURTENANCE LOADINGS, ETC. THE ANTENNA MOUNT DESIGN SHALL BE
ANALYZED AND STAMPED APPROVED TO SUPPORT DOUBLE V/V ANTENNAS,
10, PROVIDE 'APPROVED' DETAILED TOWER DESIGN/MANUFACTURER SHOP DRAWINGS
TO TOWER P,E, FOR STRUCTURAL ANALYSIS,
11, THE CONTRACTOR SHALL BE RESPONSIBLE FOR; PROVIDING, ASSEMBLING AND
ERECTING THE TOWERS, INCLUDING THE PREASSEMBLED PARTS AND CHECKING ALL
TORQUE VALUES AS LISTED UNDER THE TOWER ERECTION SPECIFICATIONS, THE
CONTRACTOR, OR SUB-CONTRACTORS, SHALL HAVE A MINIMUM OF 5 YEARS EXPERIENCE
WITH ASSEMBLING AND ERECTING SUCH TYPE TOWERS, PROVIDE PROOF OF
EXPERIENCE TO COR DURING SUBMITTAL PROCESS,
12, THE TOWER MANUFACTURER SHALL BE LOCATED WITHIN THE CONTINENTAL U.S.
AND HAVE EXPERIENCE DESIGNING AND MANUFACTURING TOWERS OF SIMILAR SCOPE,
SIZE AND COMPLEXITY FOR A MINIMUM OF FIVE YEARS,
ELECTRICAL GROUNDING:
1. GROUNDING AND LIGHTNING PROTECTION SHALL MEET FAA STANDARD 019f, "LIGHTNING PROTECTION, GROUNDING, BONDING AND SHIELDING REQUIREMENTS
FOR FACILITIES".
2. ALL GROUND RODS SHALL BE COPPER CLAD STEEL, 3/4 INCH DIAMETER AND
10 FEET LONG. GROUND RODS SHALL BE DRIVEN SUCH THAT THE TOP OF ROD
IS NO LESS THAN 12 INCHES BELOW GRADE.
3. ALL UNDERGROUND GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED
UNLESS OTHERWISE INDICATED.
4.
5.
UNDERGROUND GROUNDING CONDUCTORS SHALL BE 24 INCHES (MINIMUM) BELOW
GRADE EXCEPT AT GROUND RODS AND AS OTHERWISE INDICATED.
ADDITIONAL GROUNDING NOTES ON DRAWING ROC-1400222-E001.
3 2
STRUCTURAL STEEL & WELDING:
1. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE 13TH EDITION OF AISC
"SPECIFICATION FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS".
2. ALL STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH ASTM STANDARD A123. IF HSS OR TUBE SECTIONS ARE USED, THE HOT DIP GALVANIZING SHALL ALSO BE PROVIDED ON THE INSIDE SURFACES. THE GALVANIZING SHALL BE APPLIED AFTER FABRICATION. TOUCH UP IN THE FIELD WITH TNEME-ZINC #90-97 URETHANE ORGANIC ZINC RICH PRIMER. PREPARE SURFACE
IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. STRUCTURAL STEEL FOR WIDE FLANGE, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, EXCEPT AS OTHERWISE NOTED.
4. STRUCTURAL STEEL HSS ROUND OR RECTANGULAR SHAPES SHALL CONFORM TO ASTM A500, GRADE B, SEAMLESS, EXCEPT AS OTHERWISE
NOTED.
FOUNDATION WORK:
1. ANCHOR BOLTS SHALL BE HD GALVANIZED IN ACCORDANCE WITH ASTM A153 AND MEET OR EXCEED THE REQUIREMENTS OF ASTM
F1554-S2, S5 GRADE 105 AND SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION (FULL EFFORT OF A MAN USING AN ORDINARY
SPUD WRENCH ) •
2. NUT LOCKING DEVICE SHALL BE INSTALLED ON ANCHOR BOLTS.
3. ALL ANCHOR BOLTS SHALL BE SET BY TEMPLATE BEFORE THE CONCRETE JS PLACED.
4. CONCRETE CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF AC! 301 AND AC! 318. ALL CAST-IN-PLACE STRUCTURAL CONCRETE SHALL BE IN ACCORDANCE WITH AC! AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF F'C=3000 PSI AT 28
DAYS (NORMAL WEIGHT), OR AS SPECIFIED BY TOWER MANUFACTURER DESIGN.
5. REINFORCING STEEL- ALL DETAILING, FABRICATION, AND ERECTION OF REINFORCING BARS, UNLESS NOTED OTHERWISE, SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES CACI 315), LATEST EDITION. ALL REINFORCEMENT SHALL BE NEW BILLET STEEL, DEFORMED BARS, CONFORMING TO ASTM A615, GRADE 60 WITH A MINIMUM YIELD STRENGTH OF Fy=60,000 PSI. SPLICES IN REINFORCEMENT SHALL NOT BE ALLOWED UNLESS OTHERWISE INDICATED.
6. EXPOSED EDGES OF CONCRETE SHALL HAVE 1" CHAMFER.
7. TOP OF FOUNDATION EXPOSED TO WEATHER SHALL BE SLOPED FROM THE CENTER OF THE OUTSIDE EDGE OF A MINIMUM OF 1/4" PER
FOOT, PROVIDE A FLOATED FINISH.
8. CONCRETE SHALL BE PLACED AGAINST UNDISTURBED SOIL WHEN FOUNDATION IS BEARING ON SOIL.
9. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE MATERIALS AND OTHER OCCURRENCES WHICH
MAY DECREASE THE STRENGTH OR DURABILITY OF THE FOUNDATION.
10. WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENT.
11. MAXIMUM AGGREGATE SIZE SHALL NOT EXCEED 3/4"
12. THE TOWER FOUNDATION DESIGN SHALL BE DESIGNED AND STAMPED BY A PROFESSIONAL ENGINEER LICENSED WITHIN THE STATE WHERE THE TOWER IS TO BE ERECTED. FOUNDATION DESIGN SHALL BE BASED ON FINAL APPROVED TOWER DESIGN AND SOIL BORINGS DATA.
13. CONCRETE FOUNDATION SHALL BE FULLY 'FORMED' WITH APPROVED, CLEAN, STRUCTURALLY SOUND FORMS; BOTH ABOVE AND BELOW GRADE.
14. CONCRETE FOUNDATION SHALL BE ALLOWED TO CURE FOR A MINIMUM OF '7' DAYS PRIOR TO THE COMMENCEMENT OF TOWER ERECTION.
REFER TO SPECIFICATIONS FOR PROPER CURING CONDITIONS.
PLATFORM AND STAIRS WORK:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE STANDARD BUILDING CODE, OCCUPATIONAL SAFETY
ANO HEALTH REGULATIONS, AND LOCAL AUTHORITY HAVING JURISDICTION.
2. DESIGN LIVE LOADS: UNIFORM LIVE LOAD 37 PSF OVER THE ENTIRE WORKING AREA BUT NOT LESS THAN A TOTAL NORMAL
FACTORED LOAD OF 750 LBS.
3. SHOP DRAWINGS FOR PLATFORMS, INCLUDING FRAMING MEMBERS, BEAMS COLUMNS, CONNECTIONS, ANCHORAGE, DECK MATERIALS, TREADS, PENETRATIONS, AND RAILING SHALL BE SUBMITTED TO THE ENGINEER AND A STAMPED APPROVAL RECEIVED BEFORE FABRICATION CAN PROCEED. ERECTIONS SHALL BE MADE FROM APPROVED SHOP DRAWINGS ONLY.
4. ALL WORK SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS AND SHALL COMPLY WITH APPLICABLE CODES AND REGULATIONS. ALL CODES AND STANDARDS HEREIN REFERENCED SHALL BE LATEST EDITION, UNLESS OTHERWISE NOTED.
5. ALL SHOP CONNECTIONS THAT ARE TO BE WELDED SHALL BE ROUND SMOOTH. PLATFORMS SHALL BE SHIPPED TO THE SITE
IN THE LARGEST PRACTICAL PIECES TO MINIMIZE FIELD CONNECTIONS.
6. WELDED CONSTRUCTION SHALL COMPLY WITH AWS STRUCTURAL WELDING CODE D1.1 FOR PROCEDURE, APPEARANCE, AND
QUALITY OF WELDS AND WELDING METHODS, AND FOR CORRECTING WELDED WORK.
7. ALL HANDRAIL TUBING TO BE 1 1/2" DIA SCHEDULE 40 MINIMUM, AND SHALL HAVE Fy=41,000 PSI MINIMUM. ALL
VISIBLE WELDS TO BE GROUND SMOOTH.
8. STAIRS SHALL BE DESIGNED TO SUPPORT A 500 LB CONCENTRATED LIVE LOAD AT ANY ONE POINT.
06/25/2018 CONSTRUCTION, WR •17187 <EKSJ 1400222 03/12/2018
REV APPROVED
DATE DESCRIPTION JCN
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
REDLINE
DATE APVD
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
GENERAL NOTES
ROCHESTER GREATER ROCHESTER INT'L AIRPORT _ - NY
APPROVED BY <'7..,,£ /< -t.
M.GORDON ~- t-~ . ~
PROJECT ENGINEER MGR: ENGINEERING CENTER
DESIGNED ISSUED BY DATE I JCN
>---+--+D-R-AW_N ____ ~JT""" ENGINEERING SERVICES cco=RA~w~1NG,,-=~~=1~2=5'--12=0'°'1"'"8'-----~14"'0-"-0r"2R2"'E~=-t
0------+--+-C-HE-CK_ED __ ~E~KS COMMUNICATIONS ROC-1400 222-G003
H
G
F
E
D
C i i
B ' i z i t i i
::, N' 0::: ;:;i
~I ,,,, o, 8 ol '.=2!
ir. ' 0 i ... i i tl i
!3
C, Aili 81 Oi
?1 .
Ni N!
N ol o; ~· - ~i
.i i Si
' I 7 I 6 I 5 + 4 I 3 I
8 2 ------------------·--- --- ----· DRAWING PR1DUCED DN Af.A RO _Mlf~QS TA TION SY,,STE_"'_j
H
G
F
E
D
C
B
C u C
C, A 0.
C <'; ~"' u., . "' ~N
0 ..
ON
u ' N
Nro N~ aa
ON ~,
7"' cN o' C "'
8 7 6 r--- N 65° 45' E 250.0' -------------------- ----=--------------------,1 I I
Ni
- I l/)
• v N z1 I
I
I
40' -0"
,-REMOVE EXISTING
40' RCAG TOWER
CTYP. 4 PLACES)
SEE NOTE 4
50 1 -0 11
TOWER (NW)
L~
N.Y. ST.
G.ScE. CO.
GUYED POLE
TOWER (SW)
I
50' -0"
TOWER CSE)
\ CLASS D FENCE
\ 4 SIDES
401 -011 v a
SEPTIC •
TANK a l/) a l/) a a v j, J, I
I la
N
• v
IN
1(/)
I I
~=~~~=~~~··==·--·~·~-=~-~~·=~-~*-··=-~-=~~~=~~~==~--~L--------------tb . S 65° 45' W 250.0'
~POINT OF
BEGINNING
. / 1 ", EXISTING/DEMO SITE PLAN
·,0001 1 SCALE: 1" • 20' -
NOTES
1. THE ROC RCAG SITE IS AN OPERATIONAL FACILITY. THE CONTRACTOR SHALL
COORDINATE ALL WORK THROUGH THE COTR, SO THAT WORK MAY BE SCHEDULED
AS EFFICIENTLY AS POSSIBLE AND NOT DISRUPT THE OPERATIONS OF THE
FACILITY.
2. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UNDERGROUND
UTILITIES AND CABLES IN THE WORK AREA PRIOR TO EXCAVATING. THE
CONTRACTOR WILL COORDINATE WITH THE COTR TO LOCATE THEIR UTILITIES
AND CABLES. DUE TO.THE CRITICAL NATURE OF THE FACILITY, HAND
EXPLORATORY EXCAVATION AND/OR HOYRO-EXCAVATION SHALL BE REQUIRED
3.
4.
5.
TO LOCATE EXISTING UNDER GROUND COAX CABLES AND UTILITIES.
ALL EXCAVATION ACTIVITIES SHALL BE PERFORMED WITH FAA PERSONNEL IN
ATTENDANCE.
CONTRACTOR SHALL REMOVE ONE (1) EXISTING 40 FT. GUYED STEEL TOWER IN
THE NORTH WEST CORNER, THEN THE NEW PLATFORM TOWER CAN BE INSTALLED.
ONCE THE NEW PLATFORM TOWER IS COMPLETE, THE FAA PERSONNEL WILL NEED
TO MOVE EXISTING FREQUENCIES ONTO THE NEW TOWER. ONCE THE CUT OVER
IS COMPLETE (10 TO 15 WORKING DAYS), THEN THE THREE REMAINING 40 FT.
GUYED STEEL TOWERS CAN BE REMOVED. TOWER FOUNDATIONS AND ALL CABLE
AND CONDUIT RISERS SHALL BE REMOVED TO 12" BELOW GRADE MINIMUM.
HORIZONTAL CONDUIT AND CABLE RUNS BELOW GRADE CAN BE ABANDONED IN
PLACE. REMOVE AND DISPOSE OF ALL HARDWARE, JUNCTION BOXES, CABLES,
CONDUITS, ETC, ASSOCIATED WITH THESE FOUR TOWERS. REMOVE ALL DEBRIS
FROM THE SITE INCLUDING ANY BOLTS, NUTS, AND WASHERS THAT MAY END UP
ON THE GROUND AS PART OF THE TOWER REMOVAL. BACKFILL EXCAVATED AREAS
WITH FILL AND 6 INCHES OF LOAM, SEED ACCORDINGLY.
PLOT NOTES
OWNER ......... KEN REIMEL, CELL 233-2831 (7/28/05)
ADDRESS .•.••.. WAYLAND, NY
LOCAT!ON ..•.•. STUEBEN COUTY, NY
LATITUDE •..••• 42°30'27"
LONGITUDE .•••. 77°37'00"
ELEVATION .•... 2114
POWER •.•.•...• N.Y. STATE ELEC. & GAS
HORNELL, NY
CONTROL ••••••• ROCHESTER TELEPHONE CORP.
63 STONE ST. ROCHESTER, NY
BEARINGS •..••• ALL BEARINGS ARE TRUE
FROST DEPTH ••• 48 INCHES BELOW FINISHED GRADE
LEGEND
6 DENOTES 40'GUYED ANTENNA TOWER TYPE AS MODEL 2
WITH 4 ASB MODEL I ANTENNA BRACKETS
0 DENOTES STAKE SET
= DENOTES GUY ANCHOR
·-··- DENOTES 5 RUNS OF RG-17-U CABLE FROM EACH
TOWER TO BUILDING AS INDICATED
D DENOTES GUARD POST
THERE WILL BE A TEN TO TWENTY DAY "BURN-IN" PERIOD BETWEEN CUT-OVER TO
THE NEW TOWER AND DEMOLITION OF EXISTING TOWERS. CONTRACTOR SHALL
SCHEDULE WORK ACCORDINGLY. o DENOTES GROUND WIRE ROD (ALL GND. RODS TIED TOGETHER)
8 7 6 5
POINT OF
REFERENCE
900' TO
POWER POLE
N.Y. S.E.ScG.
1926 E.18
U.S. C.&G.S. MARKER
FOX 1939
ELEV. 2144.0'
4 I
ANTENNA PLAN
~w IQWl;;B ~I;; IQWl;;B AT-197 284.6 (Tl AT-197 284.6 FA-5197 381.6 (Tl 125.55 VHF RCVR 128.28 < R l VHF RCVR 133.75 CA-1563 133.75 (Tl 0-2277 UHF ( R l
SPARE CABLE
SW IPWEB SE IOWEB
AT-197 284.6 <Tl AT-197 335.5 AT-197 125.55 <Tl AT-197 381.6
133.75 <Tl FA-8132B NEW VHF D-2277 UHF <Tl VHF RCVR SPARE
SPARE CABLE
3 2
< R l < R l < R l
< R l < R l <Tl < R l
-. MARK$ AD,
( ·. ~ RCAG
Ir SITE l
LOCATION MAP
BOUNDARY OF
LEASED AREA
\ I \ \ \ --- -------, \'\ " '" '\
I ' ' - - - ", \ \ '\ '\
' "F-=- -- ---- """- -- -\- -\-7\ ,\ \ \ '\i._ ____ '" ", " \ \ \ I I I \
" ' " '\ '\ I \ \
\ - - , \ \ "- \\ \ I \ \ l \ \
\"-1' \ " '\ '\ \ I \ I I \
\ \ \ \ '\\ \ \\ \ \ \ I I \ 11 I I I \ \ \ \ \ I\ I \ \
\ I I I \ \\ \\ \\ \ \\ \I I \ \ \ \ I \ \ _, '::
\ I \ I t0 t0 ':: •::, '6 ° o I "' "' I _, t0 ~ ~ o o 6' er O<{ i. ,- ~ ~ 0 CJ) -'\ \ \
~ ~I : ~ I / 9 °\ ~ \ "/\ \ I \ \ I ~ I I I t> I I <J.. \ \ \ \I \ \ \ i I : / / \ \ \ \ \ I\\ \\ \\ \
(/)111 I I I I\\\ I\ 1\ \ l11 I 1 \ \ \ \ \ 1\ \\ \
'-'-I -4--1,---'-I ----'' I \ \ \ ", "- j \ I I \ \ I I \ (!) \ \ \ '\ '\ I I I \
--11-----+1-....;.\--~ PARKING 9 \ \ '\ '\ \ \ \ \
I I I \ ARE( m \ \ '\ \ 1\ \ I I \I \ \ '\ \ \ ill \ 1 I I I I \ I "- \ I / \ I I I I I I " \ , \ \ ; I I / ;
I !>'\ ,___ ~ I \ / I I I I I I " '--...._ I I I I I I I I I 111 I \ \ \ I I I I
1' / \ \__ \ J \ I I I I J I I 'Iv• __ N~7fa3oi4:;--4'!:£_4-+~\ l~" --" I / I I \ I I / I I I v 44a.o• --.... _ ~- __ --~ _ 1 _ _ 1 _ _ 1 I __ \-l I 1 / I I
\ "\ \ I I : I II I / / /
POINT OF \ I \ I / / /
BEGINNING
THIS PROJECT COPY IS BASED ON DRAWING
ROC-D-RCAG-C001, REV E, DATED 01/25/2007
A
- 06/2512018 CONSTRUCTION, WR •17187 (EKS) 1400222 03/12/2018
H
G
F
E
D
C
V
/ 2" \ VICINITY SKETCH REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVO B
SCALE: 1" = 40'
40' 0 40' 80'
SCALE: 1" = 40'
20' 0 20' 40'
SCALE: 1" = 20'
4 3
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND UPGRADES
EXISTING SITE PLAN DEMOLIITION
AREA
ROCHESTER GREATER ROCHESTER INT'L AIRPORT - NY
REVIEWED BY SUBMITTED BY n rt, J. T/MONY ~ l.::0"l~
APPROVED BY __.._,- //r/ t4, . .(:,,,--
M, GORDON J
PROJECT ENGINEER MGR: ENGINEERING CENTER
DESIGNED ISSUED BY DATE JJCN
DRAWN JT ~NGINEERING SERVICE.c-o~R-Aw-,N~G-"~'-"~"-1='25
1-"2'-"'0""18CL..----'-14""0"-'0<.:,ZR'-"~=-1~
CHECKED LR COMMUNICATIONS ROC-1400222-D001
2 1 z iE t- ~
!2 a
0 a 0 $1 f§
IL
fil
" A3 u N N N a a u u
C, _____ -.--- __ _ _ _____ Q~_AWING PRODUCED ON AEA_~()__ ~!~~Q?T __ ~T[Q!'J __ ~'t_'_S._I_S_t::1
G
F
E
D
C
B
A
I I
«!II-- - -- -
-<X)
I
I
I o~-
I I
NEW
TOWER
UP TO
' TOWER PLATFORM
l~::;;;:-==:- 1 l ~
-- - --0-- - -- - --'·
I 48 "Wx36"Hx16 11D
JUNCTION BOX
I
APPROX, 30 1
HELIAX CABLE
ENTRY PANEL
~ 48 11X36 "X16" V--- JUNCTION BOX
a)
I ~TNING 1
---------------------------------·- r-
AIR TERMINAL I
ARRESTOR I
Q,j--- - -- - -+-0-- - - ---(-- - -- - __ ,,, l I I I -<X)
I I I
I I -
(12 PERIMETER MOUNTS)
(4 CENTER MOUNTS)
16 TOTAL ANTENNA MOUNTS,
EACH WITH U/V DOUBLESTACK
ANTENNAS, 8 FT, SEPARATION
BETWEEN ALL ANTENNAS
7 6
!OVERHEAD CABLE ICE TRAY WITH
32 LMR-900 COMMUNICATIONS
CABLES TO TOWER J-BOX
AND SHELTER J-BOX
NEW 24'X24' PLATFORM TOWER
WITH 3' WIDE ACCESS STAIRWAY
RISING 30 FT, TO PLATFORM, AS
DESIGNED BY TOWER MANUFACTURER
/' 1 ', PROPOSED TOWER LAYOUT PLAN
1 C001 SCALE: 1/ 4"g1'-0"
4'
EXISTING
RCAG
SHELTER
', ·c· ..
· ,.:,4~'x3~;
PAVED
PARKING
ARE) .. ,
0 4'
SCALE: 1/ 4" = 1'-0"
8'
I I
,·"v,'
I
/EXISTING 3'X2'X1'
STAINLESS STEEL
JUNCTION BOX C2PLJ, ~ CONTRACTOR TO REMOVE
10_, BOTH J-BOXES FROM THE
~ EXTERIOR OF THE SHELTER,
,.,._,. PLUG UP THE ENTRY PORT
WITH MORTAR, AND PATCH/
FULLY REPAIR THE VINYL
SIDING ACCORDINGLY,
MATCH EXISTING SIDING
AS BEST AS POSSIBLE,
06/25/2018 CONSTRUCTION, WR •17187 (EKSl 1400222 03/12/2018
REV APPROVED
DATE DESCRIPT!ON JCN REDLINE
DATE Af'VD
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND UPGRADES
PROPOSED ANTENNA TOWER LAYOUT PLAN
AREA
ROCHESTER GREATER ROCHESTER INT'L AIRPORT ,,, ,, ~ NY
REVIEWED BY
SUBMITTED BY
M
APP
RG0QvERoOOsY_ /f':;-P" /~ kr J. TIMONY ~ ¼;,VI.\~ ~ Jfv J
PROJECT ENGINEER MGR: ENGINEERING CENTER
H
G
F
E
D
C
B z j::
"' 0
8 0 ii:, IL
Ill i C
A ~ 0
N N N
DESIGNED ISSUED BY DATE . !JCN
t---+---+co~RA~w-N ____ Jr"', ENGINEERING SERVICES ,__o~RA-w-,NG~0~N~~1~2~51~2~0~18~; 1---~14~0~0-,=,~2~E~=-.
,___,___----,~~---E-K__,s COMMUNICATIONS
CHECKED
" u
ROC-1400222-C001 ~
w
2 1 i __ _l?:~-~~!t-!~- PROQ_l!_~_EI) Q~ !'f.A 132 !'AIC~Q~T-~!!Q_~ __ ?_~STEM I
C ii' cO .g'9
01'.?
ON
" N
~ ;2 Oo ON v, -"' uN o, H
G
F
E
D
C
B
A
AIR TERMINAL MAST, GRSC
AS DESIGNED BY TOWER
MANUFACTURER - 2" MIN.
(TOP TIP OF ARRESTOR
30' ABOVE GRATING)
TOP OF GRATING
A GENERIC 24 FOOT x 24 FOOT - 30 FOOT HIGH TOWER
S001 NOT TO SCALE
7 6
16 V/V ANTENNA MOUNTS TOTAL
12 PERIMETER MOUNTS
4 PLATFORM MOUNTS
I _,Q
'I, p.
NOTE: LOCATION & LAYOUT OF
STAIRS MAY VARY.
ANTENNA MOUNTS TO EXTEND
8" ABOVE TOP OF HANDRAIL
3 1 -0 11
I I
4 3
TOP OF GRATING
24 1 -0 11
1 GENERIC TOWER ELEVATION & ST AIR PLAN
S001 NOT TO SCALE
4 3
I -0
2 1
H
G
F
E
D
C
06/25/2018 CONSTRUCTION, WR •17187 (EKSJ 1400222 03/12/2018
REV APPROVED
DATE
DESCRIPTION JCN REDLINE
DATE APVD B
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND UPGRADES
30' HT. GENERIC TOWER ELEVATION
AND STAIR PLAN
ROCHESTER GREATER ROCHESTER INT'L AIRPORT
REVIEWED BY
SUBMITTED BY APPROVED SY
J.T/MONY Rlf\"~ ' ~
PROJECT ENGINEER
AREA
NY
DESIGNED ISSUED BY DATE JCN
o---+------<-oR-Aw_N ___ ~J~T ENGINEERING SERVICES "'o;;cRA=w,=NGcc--o""N~C'-/~25~1~2=0=1B~---~== 1400222
REV
CHECKED COMMUNICATIONS ROC-1400222-$001
2 1 z
'/2 ..., 8 01
Ii:
a ILi iil !i.l
C
A3
N N N
" 0
DRAWI_NG __ f"R_ODUCEO ___ ON PE.A RO MICROST ATION SYSTEM
G
F
E
D
C
B
C C er
• • J
A a.
c<O ~v " .. -~ - "' 0 ..
ON
f
N Nro N_ oo ON v, ~"' oN o' -"'
8 7 6
#4/0 CAD-WELD TO
FOUNDATION REBAR
( 2 PLACES)
3/4 11X 10'-0" COPPER
r r. ~ STEEL GROUND ROD \ .. )----------------------""\- -----i;,1 (4 PL AROUND TOWER) r 1 r
~L\I ,_._ _________ __._..,r-'-_._./_J~ 1 .
) ~I #4/0 CAD-WELD
Ir---~ TO TOWER STEEL
11----1-' I ( 2 PLACES)
I
11-------i------ '~ r -STAIRS - 3' WIDTH I I
CLAD
24'x24'
ANTENNA TOWER
PLATFORM
! .,,.---TOWER COUNTERPOISE. #4/0
~ BARE COPPER 2' BELOW GRADE.
I EXOTHERMICALLY WELDED
I TO GROUND RODS (4 PLl
CLASS 2 MAIN DOWN
CONDUCTOR WITH 4/0
BARE TRANSITION CABLE
TO TOWER COUNTERPOISE
(2 PL, OPPOSITE CORNERS)~
~~ I I
W/ EXOTHERMIC WELDS.
I I I I I I
#4/0 BARE GND CABLE Al - '::P'~L,---------1.,---j>-l.-;::_;:-_a~--~~,......i-
#4/0 COUNTERPOISE TO
TOWER STEEL ( 2 PLACES) \1.) ~) -, .,,,.,,,,, -' //
#4/0 BARE COPPER GND CABLE _/, / /
WITH EXOTHERMIC WELDS. TOWER , //
COUNTERPOISE CONNECTED TO '-------- ~--------/
SHELTER COUNTERPOISE. (2 PLl T ,-------. I
I l'I l
EXISTING I
#4/0 BARE COPPER I I
SHELTER COUNTERPOISE~ I #4/0 INSULATED COPPER
I EXISTING I CABLE EXOTHERMICALLY
I EQUIPMENT I WELDED TO COUNTERPOISE,
TO COAX GROUND BAR IN
I SHELTER i SHELTER JUNCTION BOX I I I I
/ 1 " GROUNDING AND LIGHTNING PROTECTION SITE PLAN
,EOO], NOT TO SCALE
#4/0 INSULATED COPPER CABLE
EXOTHERMICALLY WELDED
TO COUNTERPOISE FROM
ANTENNA JUNCTION BOX ON
PLATFORM RAILING.
NOTES:
1. TYPICAL TOWER ELEVATION DETAIL. FOR ILLUSTRATIVE PURPOSES ONLY.
2. ALL DOWN CONDUCTORS ARE CLASS 2 MAIN SIZED CONDUCTORS OR LARGER;
AS DEFINED BY NFPA 780.
3. ALL DOWN CONDUCTORS ARE ROUTED DOWN THE INSIDE OF THE TOWER LEGS.
ALL DOWN CONDUCTORS ARE BONDED TO EACH TOWER SECTION AND TO THE
TOWER LEG EVERY 3' MIN WITH APPROPRIATE BONDING CLAMPS.
4. THE PLATFORM JUNCTION BOX GROUND IS BE ROUTED DOWN THE INSIDE OF
THE TOWER LEG THAT DOES NOT HAVE A DOWN CONDUCTOR. THE GROUND
CABLE IS FASTENED TO THE TOWER LEG AT EVERY 3' MIN.
5. GROUND RODS ARE COPPER CLAD STEEL, 3/4 INCH DIAMETER AND 10 FEET
LONG. SPACING BETWEEN GROUND RODS ARE TWO TO THREE TIMES THE
GROUND ROD LENGTH. GROUND RODS ARE NO LESS THAN 12 INCHES BELOW
GRADE LEVEL (BGL).
6. AIR TERMINALS ARE COPPER, A MINIMUM OF 36" IN HEIGHT, AND AT
LEAST 5/8" IN DIAMETER.
7. ALL UNDERGROUND GROUNDING CONDUCTOR CONNECTIONS ARE EXOTHERMICALLY
WELDED UNLESS OTHERWISE INDICATED.
8. ALL ELECTRICAL AND ELECTRONICS GROUNDING MEET OR EXCEED ALL
PROVISIONS OF THE LATEST EDITION OF: FAA-STD-019f, LIGHTNING AND
SURGE PROTECTION, GROUNDING, BONDING AND SHIELDING REQUIREMENTS
FOR FACILITIES AND ELECTRONIC EQUIPMENT; NFPA 70, NATIONAL
ELECTRICAL CODE CNECJ; NFPA 780, STANDARD FOR THE INSTALLATION
OF LIGHTNING PROTECTION SYSTEMS.
9. ALL EXTERIOR HARDWARE IS STAINLESS STEEL, OR HD GALVANIZED.
8 I 7 I 6 I 5
5/8" O.D. MIN,
COPPER AIR TERMINAL.
30' ABOVE TOWER PLATFORM~
I
I
CLASS 2 MAIN DOWN CONDUCTOR.
SECURED TO POLE. BONDED TO
PLATFORM PERIMETER CABLE ------ '
AND CAD WELD TO COUNTERPOISE~'
BONDING CLAMP. BONDING
PLATFORM CABLE TO TOWER ,
PLATFORM AND ANTENNA/AIR
TERMINAL MOUNTS. (TYP)
-U-BOLT
48 "H X 36 11W X 16 "D
ENCLOSURE WITH HINGED
DOOR. SECURED TO
PLATFORM RAILING.
HOFFMAN PN: A48H3616GQRLP
WITH BACKING PLATE
4' -2 11 , 2-1/2 11 I PS ,fflt-l===+==H===~'=~ t:-=;=====l'l~====r-t
RIGID STEEL ~~'R " ,-GALVANIZED PIPE /
rn .
(16 PL) TOP OF PIPE :
SHALL BE 8 11 ABOVE
TOP OF RAIL I NG :j==y===1t======i:~~ E1:5====1il=======;,<[IJJ . .
DOWN CONDUCTOR BONDING
CLAMP (TYPl, SEE NOTE 3~
CLASS 2 MAIN DOWN "'..
CONDUCTOR (TWO
OPPOSITE TOWER LEGS>---
DOWN CONDUCTOR
• . I :
I')
PARALLEL
( TYP)
CLAMP
EXOTHERMICALLY WELDED
TO 4/0 CU CABLE, 18 11
MIN ABOVE GROUND
LEVEL (2 PLl ---
•t=========;-:,~~;::::=========J· ""-----#4/0 BARE ....JLIL.L_ ______ -,G/'""----_j ~ COPPER CABLE FROM y ANTENNA J-BOX
TO COUNTERPOISE.
1" SCH 40 PVC CONDU~~T,
1 FT ABOVE AND BELOW
GRADE. ATTACHED TO
TOWER LEG. (3 PLl
TOP OF GRADE\
.-''ce."'~",00"'7 "'~ y.,CY'=I,,, v SECURED TO TOWER
LEG EVERY 3' MIN.
NOTE: STAIRS NOT SHOWN
-D
• D I -D
#4/0 GROUND CABLE CAD-WELD
TO FOUNDATION REBAR AND ~#4/0 GROUND CABLE
TO COUNTERPOISE (2 PLACES)
/ 2 ~ TOWER ELEVATION (TYP)
,Eoo1 NOT TO SCALE -
WITH EXOTHERMIC WELDS
TO #4/0 COUNTERPOISE
AND TOWER STEEL (2 PL)
06/25/2018 CONSTRUCTION, WR •17187 IEKS)
H
G
F
E
D
C
1400222 03/12/2018
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVO B
4 I 3 I -----~-
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
SITE GROUNDING DETAILS
SHEET 1 OF 2
ROCHESTER GREATER ROCHESTER INT'L AIRPORT NY
REVIEWED BY
SUBMITTED BY
J. TIMONY ~AQw ~ fl,--
PROJECT ENGINEER MGR: ENGINEERING CENTER
DESIGNED ISSUED SY
JT
ENGINEERING SERVICES DRAWN
EKS COMMUNICATIONS CHECKED
OATE 06/25/2018 IJCN
DRAWING NO
ROC-1400222-E001
1400222
REV
ts !
8i ~i o, g! -, I :
i
A~
NI
NI
N o!
~i -.
~i O' -·
2 I 1 i ------------ .. -· - --- . ---------- ORAWING PRODUCED ON ___ AEA_RO __ M1CROSTAT_l0t-,l __ SYS_l£M i u C
H
G
F
E
D
C
B
A
PERIMETER ANTENNA MOUNT (12 PL)
NOTE: 2 1/2" !PS
RIGID STEEL GALVANIZED PIPE
(12 PL) MOUNTED TO TOWER
DESIGNED BY TOWER MANUFACTURER.
THE BOTTOM OF PIPES ARE EXPOSED
FOR ANTENNA CABLE ENTRY. THE
BOTTOM OF PIPE SHALL BE THREADED
SO AS TO ACCEPT A BUSHING.
PROVIDE AND INSTALL SIXTEEN (16)
THOMAS AND BETTS 2 1/2" BUSHING
(CATALOG#: 1228)
BONDING JUMPER (TYP FOR
12 PERIMETER ANTENNA MOUNTS)
CLASS 2 MAIN DOWN CONDUCTOR
7 6
PLATFORM ANTENNA
MOUNT ( 4 PL ) ,
~:::::=;;;:,;;.:;.;;;:;~~~ ..... ~~~!aEs~~;::;;:::.~~==e:!:ifl': ~ CLASS 2 MA IN
I I
0 } 0
DOWN CONDUCTOR
(2 PL, PLACED AT
OPPOSITE CORNERS)
----AIR TERMINAL MOUNT,
2 1/2" DIA RIGID STEEL
GALVANIZED PIPE MIN,
OR AS DESIGNED
CABLE AROUND THE OJLU~T~S_I_IID~E~-----11
OF TOWER PLATFORM -
I I
48 "H X 36 "W X 1 6 "D WATERPROOF
NEMA 4X RATED FIBERGLASS
ENCLOSURE WITH HINGED DOOR,
QUICK RELEASE LATCHES AND
STUD MOUNTED BACK PANEL
(HOFFMAN: A4BH3616GQRLP)
CLASS 2 MAIN DOWN CDNDUCT~R~.:__---------~------AIR TERMINAL TO COUNTERPOISE
CABLE, RUN UNDER PLATFORM
I f [#4/0 BARE COPPER CABLE.
f ~-~ 1 ANTENNA JUNCTION BOX GND
CLASS 2 MAIN DOWN CONDUCTOR
(2 PL, PLACED AT OPPOSITE CORNERS)
8 I
-~~;:;;:;;:;;;;;::a=;;;;:;:::;::;;;;;i'ilii";:;;;!!!!~~~~Slli'~~~~~~~ BAR TO TOWER COUNTERPD I SE ,,.,, ANTENNA MOUNT
U-BOLT PIPE
BONDING CLAMP (TYP)
TOWER PLATFORM PLAN
NOT TO SCALE
I, ,, I
CLASS 2 DOWN CONDUCTOR.
(2 PER TOWER), ROUTED
DOWN INSIDE OF TOWER LEG
FROM PLATFORM PERIMETER
CABLE TO COUNTERPOISE.
I/TOWER LEG
I/
#4/0 AT A MINIMUM 18"
ABOVE GRADE. EXOTHERMIC
#4/0 AWG CABLE.
(SEE NOTE 4)
~ '- v_--- BARE #4/0 AWG I,-
·Z Z t> /> ::ii: ::g . • • • •--- 1 1 /2" SCHEDULE 40
PVC CONDUIT
ti. -00 N · t, . ti. .
• • ;,~-~-. I> •
. /j. . t, . '-.... ----J-if,EXOTHERMIC CONNECTION
#4/0 BARE COPPER .-'
COUNTERPOISE '
/ r GROUND ROD, 3/4 11 X 10'
COPPER-CLAD STEEL
OR GROUND PLATE,
./ 2 ", DOWN CONDUCTOR DETAIL
' E002 1 NOT TO SCALE
COPPER CLAD, 2 FT.
7 I 6 I
SQ.
5 +
#4/0 STRANDED
COPPER GUARD WIRE
GRADE LINE
WARNING TAPE
(SEE NOTE 5)
= z o_ ,t_ ::E
• Oz ,_
- ::E N
EXOTHERMIC WELD
3/4"x10'-0" COPPER CLAD
STEEL GROUND ROD
AIR TERMINAL
5/8" X 3'-0" MIN
BLUNT TIP (SEE NOTE 7)~
2 1/2" GRSC MAST MIN.
(OR AS DESIGNED
BY TOWER MANUFACTURER)
r
CLASS 2 ID
DOWN CONDUCTOR------ID
GALVANIZED
STEEL U-BOLT
PIPE CLAMP (TYP)
~n
-0
TO COUNTERPOISE
/ 3" AIR TERMINAL
,EOO~ NOT TO SCALE -
4 I 3
2 1 l'IU I c.;:, •
1. TYPICAL TOWER ELEVATION DETAIL, FOR ILLUSTRATIVE PURPOSES ONLY.
2. ALL DOWN CONDUCTORS ARE CLASS 2 MAIN SIZED CONDUCTORS OR LARGER;
AS DEFINED BY NFPA 780,
3. ALL DOWN CONDUCTORS ARE ROUTED DOWN THE INSIDE OF THE TOWER LEGS.
ALL DOWN CONDUCTORS ARE BONDED TO EACH TOWER SECTION AND TO THE
TOWER LEG EVERY 3' MIN WITH APPROPRIATE BONDING CLAMPS.
4. THE PLATFORM JUNCTION BOX GROUND IS BE ROUTED DOWN THE INSIDE OF
THE TOWER LEG THAT DOES NOT HAVE A DOWN CONDUCTOR. THE GROUND
CABLE IS FASTENED TO THE TOWER LEG AT EVERY 3' MIN.
5. GROUND RODS ARE COPPER CLAD STEEL, 3/4 INCH DIAMETER AND 10 FEET
LONG. SPACING BETWEEN GROUND RODS ARE TWO TD THREE TIMES THE
GROUND ROD LENGTH. GROUND RODS ARE NO LESS THAN 12 INCHES BELOW
GRADE LEVEL (BGL).
6. AIR TERMINALS ARE COPPER, A MINIMUM OF 36" IN HEIGHT, AND AT
LEAST 5/8" IN DIAMETER.
7. ALL UNDERGROUND GROUNDING CONDUCTOR CONNECTIONS ARE EXOTHERMICALLY
WELDED UNLESS OTHERWISE INDICATED.
8. ALL ELECTRICAL AND ELECTRONICS GROUNDING MEET OR EXCEED ALL
PROVISIONS OF THE LATEST EDITION OF: FAA-STD-019f, LIGHTNING AND
SURGE PROTECTION, GROUNDING, BONDING AND SHIELDING REQUIREMENTS
FOR FACILITIES AND ELECTRONIC EQUIPMENT; NFPA 70, NATIONAL
ELECTRICAL CODE (NEC); NFPA 780, STANDARD FOR THE INSTALLATION
OF LIGHTNING PROTECTION SYSTEMS.
9. ALL EXTERIOR HARDWARE IS STAINLESS STEEL, OR HD GALVANIZED.
06/25/2018 CONSTRUCTION. WR •17187 (EKS) 1400222 03/12/2018
H
G
F
D
C
APPROVED DESCRIPTION REDLINE B DATE JCN DATE APVD
1--'-----'-----------------..l...--..L-......:;:.;:.:.;;.._..J......J
REV
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND UPGRADES
SITE GROUNDING DETAILS
SHEET 2 OF 2
AREA
ROCHESTER GREATER ROCHESTER INT'L AIRPORT NY
REVIEWED BY n __./..- APPROVED BY'.,/<~/~ /trr-
J. TIMONY R(M_~ fe"" M.GORDOrv · .. __;
SUBMITTED BY
PROJECT ENGINEER MGR: ENGINEERING CENTER
ISSUED BY DATE I JCN
1---+--+D~R-AW_N ____ ~JT ENGINEERING SERVICES "'D~RA=w=,N~G -"c~~"-'1--'2"'5"-12""0"-'1-"-8-'-----1""4"'0-"-0~2R2='E~st
DESIGNED
1-----t---+C~HE~CK~[~D ----"'"EK"'-IS COMMUNICATIONS ROC-1400222-E002
2 1 j:::
ii! "' ~ ti ~
81 z g1 0 0 "' er.
0 ...
Ill i
Ai o, ;ti 0 ... , ________ ., _______ DRA~.1~(; __ PRODUCED ON AEA RO MlCROSTATlON SYSTEMJ
C
' 0
H
G
F
E
D
C
B
A
8 7 6 v
TWIST-LOCK LATCHES
fol lol lol - D
0 0
A A
1L....ffl---------lH----'
,o
\__CUT LARGEu:VAL
TO ALLOW CABLE
uu
OPENING IN TOP OF BOX
ENTRY TO GROUND BAR
SINGLE DOOR TYPE 3R ENCLOSURE
m
H I I
GASKET
CONTINUOUS HINGE
rBACK PLATE
SECTION A-A
,' B '\ JUNCTION BOX
' E003' NOT TO SCALE
' ;alil~
' H
48 11 X 36 11 J-BOX
rHOFFMA~A48H3616GQRLP
I I Q I l::
0 O ,,--STUD MOUNTED
V 2: BACK-PANEL
INSTALL #4/0 INSULATED
COPPER CABLE (GREEN WITH
LnJ
#4/0 AWG
THWN COPPER CABLE ,_/
IN PVC CONDUIT TO
BUILDING COUNTERPOISE
--0 0
I=
LnJ f'--__ 1 1/4" SCHEDULE 40 PVC
CONDUIT (GND)
/' A ', SHELTER JUNCTION BOX INSIDE DETAIL
\E003/ NOT TO SCALE -
I 7 I .... -----------
RED TRACER) ATTACH BY
EXOTHERMIC WELD TO
SHELTER COUNTERPOISE
6 I
5 4
NOTE
INSTALL W~LL ENTRY PANEL TIMES MICROWAVE (TM) EP-1576
WITH 8, 4' ENTRY CUSHION FOR LMR-900 CABLES,
TM #1 SC-900-4, PLUG EMPTY HOLES. EXACT LOCATION
TO BE FIELD DETERMINED. SEAL ALL EMPTY OPENINGS.
o I I
0 ~
I
~ ~ ~ ~ PULL 32 LMR-900 CABLES
11.f-' ,. (;. V INTO JUNCTION BOX. LEAVE
PLENTY OF SLACK FOR FAA
, TERMINATIONS
• ··-· . -·- --,;; - ·- -· -·-le;;
., '" "'1,, 1 __- INSTALL ONE 48"X36"X16"
., 0 -~ 0 V HOFFMAN P /N: A48H3616GQRLP
WITH THREE POINT LATCH HANDLE
BOX WITH HANDLE COVER
~INSTALL #4/0 THWN INSULATED GND
CABLE (MARKED RED/ GRN) FROM
SHELTER BOX TO SHELTER
EES. CABLE SHALL BE INSTALLED THRU
THE WALL AND INSIDE A 1-1/2 11 GRSC.
CABLE SHALL BE EXOTHERMICALLY
WELDED TO THE SHELTER EES.
2 1
(o~-------------~o')
/ C '- INTERIOR ELEVATION
,E003 NOT TO SCALE
CABLE ENTRY PORT
REPAIR AND PATCH
SIDING, AS NEEDED SHELTER JUNCTION BOX
( 48 11H X 36 11W x 16 "D)
NEMA-3R WITH STUD
MOUNTED BACK-PANEL
ATTACHED TO INTERIOR
OF SHELTER
NOTES:
1. ONE CABLE JUNCTION BOX ON THE INTERIOR OF THE SHELTER. EXACT LOCATION
SHALL BE FIELD DETERMINED AND SHALL BE COORDINATED WITH THE ON-SITE
FAA REPRESENTATIVE. JUNCTION BOX IS 48"H x 36"W x 16"D NEMA TYPE 3R
ENCLOSURE WITH A GASKETED HINGED COVER, TWIST-LOCK LATCHES, AND
HARDWARE TO INSTALL A LOCKING DOOR HANDLE. JUNCTION BOX INCLUDES
STUD MOUNTED BACK-PANEL, HOFFMAN P/N: A48H3616GQRLP.
2. A #4/0 AWG INSULATED GROUND CABLE (GREEN WITH A RED TRACER). CABLE
SHALL BE EXOTHERMICALLY WELDED TO THE SHELTER COUNTERPOISE. SECURE
4/0 CABLE TO THE SHELTER INTERIOR WALL WITH CONDUIT CLAMPS AS NEEDED.
3. LMR-900 COAX CABLES RUN FROM THE SHELTER JUNCTION BOX THE ANTENNA
PLATFORM JUNCTION BOX (32 RUNS).
4. CUT LARGE OVAL OPENING IN THE TOP OF THE BOX TO ALLOW HELIAX CABLE
PASS-THRU ACCESS.
06/25/2018 CONSTRUCTION, WR •17187 <EKSJ 1400222 03/12/2018
H
G
F
E
D
C
----- 1 1/4 11 SCHEDULE 40 PVC
CONDUIT WITH #4/0 THWN.
CONDUIT TERMINATED REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVO B
'D' ' ' \E003/ -
5 +
12" BELOW GRADE.
EXOTHERMIC WELD
TO EXISTING COUNTERPOISE
SHELTER JUNCTION
BOX MOUNTING (TYP)
NOT TO SCALE
4 I
3 I
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
SHELTER JUNCTION BOX DETAILS
ROCHESTER GREATER ROCHESTER INT'L AIRPORT ~ fi ____...,, NY
REVIEWED BY :B;;;~;fcMG»v,~ ~ :;~;~;,f'; /~ ,C~
PROJECT ENGINEER MGR: ENGINEERING CENTER
ISSUED BY DATE 06/25/2018 IJCN 1400222
t---+--+D-R-AW_N ____ -"-'-iJT ENGINEERING SERVICES r.cDRC""CA,CCWICCNGc--='NO~~~~---~-"-"-iccc'RE'c'=-IV
1-----;~---+----~E=Ks"-l COMMUNICATIONS
CHECKED
DESIGNED
ROC-1400222-E003
2 I 1 DRAWING PRODUCED ON AEA RO MICROS TA TION .. --- --~------ - ---------- . -· --- - -·-------·---ts j::
i ti
0 ...
l;l i oi Ni ,.,:
1'i
"'' o' Oi
2: .. ' i i ' c!
"' A n,.
"" O, o, a'
SYST.~~l
F
E
D
C
A
2 1/2" PVC LB WITH PIPING TO
THE 4 CENTER MOUNT ANTENNAS
(4 PLACES)
7 6
TOWER AJB
JUNCTION BOX LAYOUT
INSTALL LIQUID-TIGHT
STRAIN RELIEF CONNECTORS
FOR CABLES & B PIN: 2562 OR
APPROVED EQUAL (32 PLACES)
INSTALL THIRTY TWO LMR-900 COAX
CABLES FROM PLATFORM BOX TO
SHELTER BOX
A ANTENNA PLATFORM J-BOX (ELEVATION)
E004 NOT TO SCALE
t---- INSTALL 48"H x 36"W x 16"0
WATERPROOF NEMA 4X RATED
FIBERGLASS ENCLOSURE WITH
HINGE DOOR, QUICK RELEASE
LATCHES, AND MATCHING STUD
MOUNTED BACK PANEL (HOFFMAN
P/N: A48H3616GQRLP OR
APPROVED EQUAL). SECURE
ENCLOSURE TO THE HANDRAIL
OF THE TOWER. ENCLOSURE
SHALL BE CENTERED BETWEEN
ADJACENT ANTENNA MOUNTS.
LJ.----INSTALL #4/0 AWG INSULATED
COPPER GROUND CONDUCTOR
(GREEN WITH RED TRACER)
ROUTED DOWN AND EXOTHERMICALLY
WELDED TO ANTENNA PLATFORM
COUNTERPOISE
INSTALL LIQUID-TIGHT
STRAIN RELIEF CONNECTOR
FOR #4/0 COPPER GROUND
CABLE CT & B P/N:2523
OR APPROVED EQUAL)
INSTALL 1 1/2" GALVANIZED
UNISTRUT CHANNEL SUPPORT
FOR JUNCTION BOX ------<'
TOE BOARD (TYP)
TOWER LEG--~,
_,-----ANTENNA CABLE
JUNCTION BOX
CENTERED BETWEEN
ADJACENT ANTENNA
MOUNTS.
PLATFORM FLOOR
INSTALL #4/0 INSULATED
COPPER CABLE (GREEN WITH
RED TRACER) FROM PLATFORM
J-BOX TO TOWER EES. SECURE
EVERY 3 FEET MINIMUM TO INSIDE
OF TOWER LEG THAT DOES NOT
HAVE A DOWN CONDUCTOR
1 ANTENNA PLATFORM J-BOX MOUNTING
E004 NOT TO SCALE
1, ONE 48"H X 36"W X 16"D NEMA-4X FIBERGLASS ENCLOSURE WITH HINGE DOOR,
QUICK RELEASE LATCHES, AND MATCHING STUD MOUNTED BACK PANEL <HOFFMAN
P/N: A48H3616GQRCP OR APPROVED EQUAL). ENCLOSURE TO BE SECURED TO THE
HANDRAIL OF THE TOWER PLATFORM WITH THE TOP OF THE BOX BEING FLUSH
WITH THE TOP OF THE HANDRAIL, ENCLOSURE SHALL BE CENTERED BETWEEN
ADJACENT ANTENNA MOUNTS,
2, ONE #4/0 THWN COPPER GND CABLE (GREEN WITH RED TRACER), THRU A JUNCTION
BOX LIQUID-TIGHT STRAIN RELIEF CONNECTOR (THOMAS & BETTS P/N 2523),
FROM PLATFORM JUNCTION BOX TO THE TOWER COUNTERPOISE. THE GND CABLE
IS ROUTED DOWN THE INSIDE OF A TOWER LEG THAT DOES NOT CONTAIN A DOWN
CONDUCTOR. THE GND CABLE IS ATTACHED TO THE TOWER EVERY 3' MINIMUM
WITH AN APPROVED FASTENER. THE END OF THE GND CABLE IS RUN INTO THE
EARTH IN A 1" SCHEDULE 40 PVC CONDUIT RUN 12" ABOVE AND BELOW GRADE
AND IS EXOTHERMICALLY WELDED TO THE #4/0 TOWER COUNTERPOISE,
3, LIQUID-TIGHT STRAIN RELIEF CONNECTORS(THOMAS & BETTS P/N: 2562), ONE
PER LMR-900 COAX CABLE, AT THE BOTTOM OF PLATFORM JUNCTION BOX. THE
LIQUID-TIGHT CONNECTORS ARE SPACED TO ALIGN CABLES TO THE TYPE N
BULKHEAD CONNECTORS IN JUNCTION BOX GROUND BAR,
4, THIRTY TWO LMR-900 COAX CABLES (TIMES MICROWAVE SYSTEM) FROM THE
PLATFORM JUNCTION BOX TO THE SHELTER JUNCTION BOX.
5, ALL EXTERIOR HARDWARE SHALL BE STAINLESS STEEL, OR HD GALVANIZED,
06/25/2018 CONSTRUCTION, WR •17187 <EKSJ 1400222 03/12/2018
H
G
F
E
D
C
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVD B
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
ANTENNA PLATFORM JUNCTION BOX DETAILS
ROCHESTER GREATER ROCHESTER INT'L AIRPORT
PROJECT ENGINEER MGR: ENGINEERING CENTER
DESIGNED ISSUED BY DATE JCN
1---1-----+=DR~Aw=N~--~J~T ENGINEERING SERVICES 1c-D~RA-WI-NG~0~N~-1=25- 1-2-0-18~---1~4-0-02rR~~~
1-----+---tc-c~HE~cK=rn--~EK=S COMMUNICATIONS ROC-1400222-E004
C
A~ a a V
N N N g C
F
E
D
C
B
C u C
" 0
QC
:, A a.
&:2 ~.
·~ "'~ 0 ..
ON •
N N cr, N_ oo
ON ~, -.,,
oN o'
' 0 r')
' 0 r')
TIP OF AIR TERMINAL
PROVIDE & INSTALL
12 PERIMETER
ANTENNA MOUNTS
( SEE DTL. 2)
30 FT. HT. TOWER,
24'x24' PLATFORM, 16 ANTENNAS
28' APPROX.
6 5
PROVIDE AND INSTALL 8,
4 "-HOLE ENTRY BOOTS
FOR LMR-900 COAX CABLE.
TIMES MICROWAVE (PN: SC-900-4)
PROVIDE AND INSTALL 1 1/2"
SCH 40 PVC LB AND CONDUIT
FOR #4/0 GROUND CABLE
FROM INTERIOR JUNCTION BOX.
CONDUIT SHALL EXTEND A
MINIMUM OF 12" BELOW GRADE.
PROVIDE AND INSTALL
#4/0 AWG INSULATED CABLE
(GREEN WIRED TRACER)
EXOTHERMICALLY WELDED
TO COUNTERPOISE THROUGH
PROVIDE AND INSTALL COAX
CABLE WALL FEED THROUGH
PLATE WITH EIGHT, 4" HOLES;
TIMES MICROWAVE ENTRY PANEL
(PN: EP-576) OR EQUAL
' 0
GRADE
EES COUNTERPOISE LB AND CONDUIT ON EXTERIOR'___---7
FROM INTERIOR JUNCTION BOX 1---......,l,----...t;....-----, CAD-WELD GROUND CABLE
TO SHELTER EES
B SHELTER (SIDE VIEW - FACING TOWER)
E005 SCALE: 1/ 4"=1'-0"
CENTER MOUNT
(4 PLACES, SEE DTL. 1)
INSTALL 48"H X 36"W X 16"0
JUNCTION BOX. SECURE TO TOWER
RAILING WITH STRUT (HOFFMAN
A48H3616GQRLP-WITH BACKING PLATE)
----INSTALL THOMAS & BETTS CONDUIT
FITTINGS CPN: 2562) ON EACH CABLE
ENTERING BOTTOM OF J-BOX
----4 PLATFORM ANTENNA MOUNTS TO BE FITTED
WITH 2 1/2" SCHD. 40 PVC, PIPED AND
FITTED BACK TO PLATFORM JUNCTION BOX
SEE DETAIL 1
3' WIDE STAIRS TO 30' HT.
TOWER PLATFORM
INSTALL THIRTY TWO TIMES MICROWAVE
LMR-900 COAX CABLES FROM TOWER JUNCTION
BOX GND BAR TO SHELTER SURGE PROTECTORS
INSTALL 24" WIDE ICE BRIDGE KIT(Sl
WITH TRAPEZES, SITE PRO 1-IB24D-Z2
WITH APPLICABLE SS TRUE-GRIP SNAP-IN
HANGERS (78SH-3l SIZED FOR DISTANCE
BETWEEN SHELTER AND TOWER. INSTALL
PER MANUFACTURER'S SPECIFICATIONS
I I
1 3' -4" POL ES
10' SPACING
BETWEEN POLES
1'-4" (MIN)
SONOTUBE
APPROX. 30'
A E005
ICE BRIDGE SUPPORT POST, EVERY
10 FEET MINIMUM, OR LESS PER
MANUFACTURERS RECOMMENDATION
TOWER AND SHELTER (FRONT VIEW)
SCALE: 1/ 4"=1'-0"
4'
2 112" GRSC JPS
WITH CUSTOM
DESIGNED SUPPORT
PLATE FOR V/V TACO
ANTENNA 05072----,-__
BOTTOM OF PIPE TO PASS
THROUGH GRATING, FITTED
WITH 2 1/2" 90 DEG SWEEP AND
PIPED TO SIDE OF JUNCTION
BOX. USE SCH 40 PVC. ___ _,,
If)
2 1
PLATFORM GRATING
FAA COMM CABLE
PLATFORM CENTER MOUNTS (4 REQD)
NOT TO SCALE
2 1/2" GRSC JPS WITH
THREADED BOTTOM FITTED
WITH COMMERCIAL GRADE
EXTERIOR BUSHING
THOMAS AND BETTS 2 1/2"
(CATALOG#: 1228) (12 PLACES)
If)
PERIMETER ANTENNA MOUNTS (12 REQD)
' 0 -
NOT TO SCALE
NOTES:
1. INSTALL THIRTY TWO LMR-900 TIMES MICROWAVE COAX CABLES
FROM THE SHELTER JUNCTION BOX TO THE PLATFORM J-BOX
(APPROX 3000 LF TOTAL OF CABLE - FIELD VERIFY).
2. PROVIDE A WAVEGUIDE LADDER TO SUPPORT THE THIRTY TWO
LMR-900 CABLES, VERTICALLY MOUNTED TO TOWER. THE
WAVEGUIDE LADDER SHALL BE DESIGNED WITH PREDRILLED
HOLES, SPACED EVENLY. THE WAVEGUIDE SHALL BE DESIGNED
TO ACCEPT SITE PRO 1 "TRUE-GRIP SNAP-IN" HANGERS
(#78SH-3l TO SECURE THE COAX CABLES. THE WAVEGUIDE
LADDER WILL SUPPORT THE COAX CABLES AS THEY TRANSITION
FROM THE HORIZONTAL CABLE ICE TRAY VERTICALLY UP THE
FULL TOWER HEIGHT TO THE JUNCTION BOX.
3. WAVEGUIDE VERTICAL CABLE SUPPORTS SHALL BE SPACED
AT 3 FEET INTERVALS FOR THE FULL HEIGHT OF TOWER.
06/25/2018 CONSTRUCTION, WR •17187 (EKS) 1400222 03/12/2018
H
G
F
E
D
C
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVD B
0 4' 8'
SCALE: 1/ 4" = 1'-0"
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
RCAG
TOWER REPLACEMENT AND UPGRADES
COAX CABLE INSTALLATION
ROCHESTER GREATER ROCHESTER INT'L AIRPORT
PROJECT ENGINEER
DESIGNED
JT
DRAWN
EKS
CHECKED
MGR: ENGINEERING CENTER
ISSUED BY DATE JCN
ENGINEERING SERVICES DRAWING ~~
12512018
COMMUNICATIONS ROC-1400222-E005
NY
1400222
REV
C
A~ 0 • N N N g w
2 1 DRAWING PROOUCEO ___ Q~-- !'!:!: -~Q. ~_lf~9sr ATlON S':'_~EM j
C , H
G
F
E
D
C
B
A
INTERIOR CABLE
JUNCTION BOX
48"H X 36"W X 16"DP
INSTALL CABLE ENTRY
PORT THRU WALL, REPAIR
AND MATCH EXISTING
SIDING AS REQUIRED
I
I""
I"" I~
<O l,"' i /
MULTIPOINT
GROUND
7 6
32'
,-AC ~N-;-T- - -1
RACK RACK RACK RACK RACK
#10 #11 #12 #13 #14
DC DC ATCB1
BUSS BUSS BEACON FUTURE FUTURE
' SINGLE POINT
GND
I
I
MULTI-POINT
GROUND
I I
SQUARE "D"
I
I
RACK RACK RACK RACK RACK RACK RACK
#8 #7 #6 #5 #4 #3 #9
MINI RCAG RCAG RCAG RCAG SBUEC NDP
DEMARC
MAIN GROUND
7 6
I 36" DOOR I <FUTURE)
a::
I-
UJ
a::
EXISTING RF CONDUIT
EXISTING RACK
#1 CABLE TRAY
FT!
GENERIC FLOOR PLAN
NOT TO SCALE
I
40" DOOR
4 3
I
"" z -0:
a:: I-
UJ 3 ...I
:c 0 0 -'
"" LL
a::
w
GENERATOR
:c "" (j a::z
OUJ
3<0
I
:c GENERATOR ROOM (j a:: I-
UJ-
LL3: -0:
XVl a:: ...I
UJUJ
0-0:
a..a.. -
I I
4 3 I
2 1
H
G
RACK NUMBER FREQUENCY/FUNCTION
I RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
RACK
FTI
NDAG
128.025 I 323.250 MHz
119.375 I 235.975 MHz
243.000 I 369.000 MHz
127.475 I 346.350 MHz
124.325 / 353.850 MHz
MINI-DEMARC
DC BUSS
DC BUSS/ POWER PANEL
ATCB1 - BEACON TX/RX
FUTURE
FUTURE
THIS PROJECT COPY IS BASED ON DRAWING
ROC-D-RCAG QFP001, REV B, DATED 1/9/2017
06/25/2018 CONSTRUCTION, WR •17187 <EKSJ
F
E
D
C
03/12/2018
REV APPROVED
DATE DESCRIPTION JCN REDLINE
DATE APVO B
DEPARTMENT OF TRANSPORTATION
FEDERAL A VIA TI ON ADMINISTRATION
ATO - TECHNICAL OPERATIONS EASTERN SERVICE
RCAG
TOWER REPLACEMENT AND UPGRADES
EQUIPMENT ROOM LAYOUT
ROCHESTER GREATER ROCHESTER INT'L AIRPORT
REVIEWED BY SUBMITTED BY /) A APPROVED BY ~ ~,
J.TIMONY~~~ ~ M.GORfXffi "'"
PROJECT ENGINEER MGR: ENGINEERING CENTER
DESIGNED
JT
DRAWN
EKS
CHECKED
ISSUED BY DATE , iJCN
ENGINEERING SERVICES DRAWING ~~
12512018 1