1‐Aug‐22
3AE MOLESKY
BUNKER STATION AND SHORE POWER PROVISIONS
PORT AND STBD BUNKER MANIFOLDS ARE IDENTICAL
BUNKER STATIONS ARE LOCATED FR.55‐FR.60
SHORE POWER CONNECTION LOCATED AT FR.0
CONNECTION TYPE FLANGE SIZE
FUEL OIL JIS ‐ 6Inch Flange
SLOPS 6 Bolt Flange, Diameter ‐ 8.5"
MGO JIS ‐ 4Inch Flange
SLOPS (2) 6 Bolt Flange, Diameter ‐ 8.5"
MECO JIS ‐ 3Inch Flange
AELO/MELO JIS ‐ 3Inch Flange
POTABLE 2.5 Inch NH Hose Connection
SERVICE AIR Quick Connect Air Fitting
SEWAGE CONNECTION (ONLY ON PORT SIDE JIS ‐1 1/2" flange
SHORE POWER
MAIN SHORE POWER CONNECTION IS FITTED TO HANDLE (TWO)‐THREE PHASE LEGS
WITH THE MAIN SWITCHBOARD AND BREAKER ABLE TO HANDLE UP TO 500 AMP SERVICE
AT 450 VOLTS*
*Service to be upgraded to 800 AMP Capacity