Bridge_Insp_Report_5140-182P.pdf
PDF 9 MB Posted
- Attached to
- Blue Ridge Parkway - NP-BLRI 2H16
- Solicitation number
- 693C73-19-R-000005
About this file
Bridge Insp Report_5140-182P
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADV_Offeror's_Qualifications_Form.doc | DOC document | |
| FP14_Eng.pdf | ||
| Certification_Prog_for_Bridge_Temp_Works.pdf | ||
| Nat_White_Nose_Decontam_Protocol_04.12.2016.pdf | ||
| Plans_-_NP-BLRI_2H16.pdf | ||
| Field-Trip-Report_11-16-17.pdf | ||
| NEPA_Doc_CE.pdf | ||
| RFP_Solicitation_-_NP-BLRI_2H16.pdf | ||
| VETS-4212_-_Form_-_2018.pdf | ||
| Synopsis_-_NP-BLRI_2H16.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURE SUMMARY STRUCTURE NO. 5140-182P
LINN COVE VIADUCT INSPECTION DATE: 6/19/17
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... P/S CONCRETE CONTINUOUS NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... SEGMENTAL BOX GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 1 STRUCT. TOTAL LENGTH: .. 1,248.9 FT (380.7 M)
DECK TYPE: ......................... CONCRETE PRECAST PANELS MAX. SPAN LENGTH: .......... 180.0 FT (54.9 M)
WEARING SURFACE: .......... BITUMINOUS DECK WIDTH: ...................... 38.5 FT (11.7 M)
ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 34.3 FT (10.5 M)
PIER FOUNDATION(S): ........ SPREAD FOOTING ON PILES YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... BR2H7 / BR2H7 SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ NO
STRUCTURE HISTORY: ...... 2000-SOUTH ABUTMENT BEARING PADS RESET.
LOCATION
BLUE RIDGE PARKWAY MILE POINT: ..................... 304.02 (KM PT 489.26)
STATE: ................................. NORTH CAROLINA LOCATION: 0.99 MILES FROM U.S. ROUTE 221 ACCESS USING HATCH AT SOUTH ABUTMENT, FACILITY CARRIED: ............ BLUE RIDGE PARKWAY
LOCK KEY #A255
FEATURE INTERSECTED: .. LINN COVE BRANCH
STRUCTURE EVALUATION SUMMARY
This precast segmental concrete box girder bridge is in good condition overall. The main problem is deterioration of the asphalt wearing surface on the deck and on the approach slabs, including buckling and widespread longitudinal, transverse, and map cracking throughout. Other problems include failure of the neoprene drainage troughs at both bridge ends, misaligned curb stones on the west side of Span #1 and Span #8, and missing and/or loose rail hardware at various locations.
The structure has experienced shifting at the abutments in the past and has some cracking in the pintle and bottom slab at the north abutment, both of which are examined at each inspection. No appreciable shifting has occurred since the previous inspection and no additional distress to the structure or bearing pads was noted. Rusting of the steel plates at various post tensioning anchorage blocks has caused cracking and spalling of the grout blocks at those locations. The severity of this condition does not appear to have increased since the previous inspection. Both of the above referenced items will continue to be monitored.
This bridge is scheduled for improvements in the future under Project PRA-BLRI 2H14.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: M. REGER, N. JANSEN
CONDITION ASSESSMENT:
MICHAEL REGER, P.E., FIELD TEAM LEADER 703-948-1424
REPORT REVIEW:
MARCUS MILLER, P.E., BRIDGE INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 12/6/17
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-182P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure exhibits severe deterioration, presents a safety hazard, or is designated a high priority due to age and/or condition.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
C226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
58.3, 222.1 REMOVE AND REPLACE WEARING SURFACE ON BRIDGE DECK AND
APPROACH SLABS.
1 LS $0
58 WATER PROOF MEMBRANE 1 LS $0
58.7 REPLACE NEOPRENE DRAINAGE TROUGHS AT BOTH EXPANSION
JOINTS.
80 LF $0
58.5 RESET DISPLACED CURB STONES ON WEST SIDE OF SPAN #1 &
SPAN #8.
1 LS $0
58.6 REPLACE MISSING RAIL END PLATE AND MISSING RAIL
HARDWARE. TIGHTEN LOOSE RAIL POST ANCHOR BOLT NUTS AS
NECESSARY.
1 LS $0
CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND
DESIGN/CONSTRUCTION ENGINEERING.
1 LS $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-182P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE
9 EXCELLENT CONDITION
8 VERY GOOD CONDITION - no problems noted.
7 GOOD CONDITION - some minor problems.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
1 “IMMINENT” FAILURE CONDITION - major deterioration or sec ion loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
58. DECK 7
1. DECK SLAB G
2. EXPANSION JOINTS F
3. WEARING SURFACE F
4. RIDEABILITY F
5. CURBS, SIDEWALKS, AND MEDIAN F
6. PARAPETS AND/OR RAILINGS G
7. DRAINS AND DRAINAGE G
8. UTILITIES N
9. DEFLECTION AND/OR VIBRATION G
10. OTHER N
59. SUPERSTRUCTURE 7
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10. ALIGNMENT
11. OTHER
60. SUBSTRUCTURE
ABUTMENTS
1. BREASTWALLS OR COLUMNS
2. PILE BENTS
3. CAPS AND/OR BEARING SEATS
4. BACKWALLS AND/OR BULKHEADS
5. FOUNDATIONS
6. WINGWALLS
7. WEEP HOLES
8. EXPANSION JOINTS
9. EROSION AND/OR SCOUR
10. SETTLEMENT OR DEFLECTION
11. SLOPE PROTECTION
12. OTHER
PIER(S)
13. WALLS AND/OR COLUMNS
14. PILE BENTS
15. CAPS AND/OR BEARING SEATS
16. FOUNDATIONS
17. EROSION AND/OR SCOUR
18. SETTLEMENT OR DEFLECTION
19. OTHER
F G N N N G N N G F N
G N G G G G G G F G N N
G N G G F G N
58.1, 222.1
58.2
58.3,4,5
58.5,7
58.6
58.7
ITEM REFERENCE AND REMARKS
MINOR CRACKING ON SIDES OF DECK SLAB, AND MINOR SPALLING
ON SLAB UNDERSIDE AT SEVERAL LOCATIONS. WIDESPREAD
MINOR EFFLORESCENCE ON CONSTRUCTION JOINTS IN WEST
OVERHANG. SPAN #8 IS OFFSET 1.5" TOWARDS EAST AT SOUTH
ABUTMENT. EXPOSED REBAR ON DECK UNDERSIDE AT SEVERAL
LOCATIONS DUE TO INSUFFICIENT CONCRETE COVER.
MINOR CRACKING WITH EFFLORESCENCE ON UNDERSIDE OF
APPROACH SLABS AT ABUTMENTS. MINOR LONGITUDINAL
CRACKING OF TOP SURFACE OF APPROACH SLABS. SOUTHEAST
CORNER OF NORTH APPROACH SLAB IS CRACKED.
SOUTH EXPANSION JOINT MISALIGNED; NEOPRENE DRAINAGE
TROUGHS UNDER ABUTMENT EXPANSION JOINTS HAVE
COMPLETELY SPLIT. MINOR DEBRIS ACCUMULATION WITH
VEGETATION GROWTH IN JOINTS.
SEVERAL PAVEMENT BLISTERS ALONG EAST CURB LINE.
MODERATE DETERIORATION OF WEARING SURFACE CAUSES
UNEVEN RIDE. MODERATE TRANSVERSE, LONGITUDINAL, AND
MAP CRACKING PRESENT THROUGHOUT LENGTH OF BRIDGE.
SEVERAL SMALL AREAS OF BUCKLING IN NORTHBOUND LANE. UP
TO 1.5" DEEP GROOVE IN WEARING SURFACE ALONG CURBS WITH
DAMPNESS AND MOSS GROWTH; DETERIORATED MORTAR JOINT
ALONG CURBS. CRACKING OF WEARING SURFACE AT SCUPPERS
ALONG WEST CURBS; MINOR DELAMINATION AROUND SCUPPERS.
CURB STONE DETACHING ON WEST CURB NEAR NORTH ABUTMENT
AND ON WEST CURB NEAR SOUTH ABUTMENT. MINOR DEBRIS AND
VEGETATION GROWTH IN CURBLINE. MINOR SPALLING WITH
EFFLORESCENCE OF CURB MASONRY JOINTS. MASONRY
DETACHING FROM FACE OF WEST CURB, RANDOMLY LOCATED.
MINOR CRACKING, SPALLING, AND DELAMINATION IN SEVERAL
LOCATIONS ALONG CURBS.
MISSING END CAP ON EAST RAIL AT SOUTH ABUTMENT. MISSING
RAIL HARDWARE IN FEW LOCATIONS. MINOR RUST ON SEVERAL
BOLTS. SEVERAL LOOSE NUTS ON POST ANCHOR BOLTS.
WATER SPILLING ONTO BEARING SEATS BECAUSE OF SPLIT
DRAINAGE TROUGHS (SEE 58.2). SEVERAL CLOGGED DRAINS IN
BOTTOM SLAB OF BOX GIRDER.
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 7
G G N G N
LOW
SUFF
50 FT.
ROCK
222. APPROACHES 8
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS G
N G G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDS D.
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA. 1
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
59.1 EAST BEARING PAD AT SOUTH ABUTMENT IS LEANING TOWARD
WEST 0.5" (5-DEGREES) AND SOUTH 1" (10-DEGREES). WEST
BEARING IS SHIFTED 1.5" TO WEST. NORTH ABUTMENT BEARING
PADS HAVE NO NOTICEABLE DEFLECTION.
59.2,6 BOX GIRDER EXTERIOR: BOTTOM SLAB AT END OF BOX CRACKED
AT NORTH ABUTMENT DUE TO SEASONAL (WINTER) CONTACT WITH
PINTLE. MINOR CRACKING WITH EFFLORESCENCE ON EAST SIDE
OF BOX GIRDER. MINOR SPALLING DUE TO INSUFFICIENT
CONCRETE COVER RANDOMLY LOCATED. SEVERAL AREAS OF
EXPOSED REBAR ON BOX GIRDER UNDERSIDE, SPAN #2 NEAR PIER
#1, MIDSPAN OF SPAN #5, AND WEST SIDE NEAR PIER #6. ACCESS
DOOR AT NORTH ABUTMENT WELDED SHUT. HATCH NEAR SOUTH
ABUTMENT AVAILABLE FOR ACCESS TO INTERIOR OF BOX GIRDER,
KEY FOR LOCK NEEDED.
59.2,6 BOX GIRDER INTERIOR: MINOR RUSTING ON SEVERAL
ANCHORAGES RESULTING IN SEVERAL GROUT CAPS BREAKING
OFF. HAIRLINE HORIZONTAL CRACKING OF SEVERAL POST
TENSION DUCTS; CRACKING CONTINUES INTO BOX GIRDER WEBS.
VERTICAL CRACK ON EAST SIDE OF PT #106. HAIRLINE DIAGONAL
CRACKING OF PT #109W. MINOR CRACKS IN ANCHOR BLOCKS AT
#67W AND #71W. DIAGONAL CRACKING OF DIAPHRAGM AT BOTH
SIDES OF PIER #2 (TYPICAL). MINOR HONEYCOMBING
THROUGHOUT. SPALL FROM CONSTRUCTION IN CEILING ON COLD
JOINT AT MIDSPAN OF SPANS #2 AND #3. MINOR TRANSVERSE
CRACK AT MIDSPAN OF SPAN #5. TWO MINOR CRACKS ON
UNDERSIDE OF DECK NEAR SOUTH END OF SPAN #6; ATTEMPTS
HAVE BEEN MADE TO SEAL CRACKS.
SPALL ON ANCHORAGE BLOCK #63W. EXPOSED REBAR NEAR
ANCHORAGE BLOCKS AT SEVERAL LOCATIONS. HOLE IN EXTERIOR
WEB AT CONSTRUCTION JOINT BETWEEN BLOCKS #19E AND #20E
WITH PATCHED AREA ABOVE. MODERATE SPALLING ON MIDSPAN
DIAPHRAGMS THROUGHOUT LENGTH OF BRIDGE.
INSTRUMENTATION, CONSTRUCTION MATERIALS, AND DEBRIS
REMAIN INSIDE BOX. GRAFFITI AND TRASH THROUGHOUT BOX.
RODENTS INHABIT BOX GIRDER. BOARDS HAVE BEEN INSTALLED
TO ATTRACT AIRBORNE RODENTS.
59.10 SUPERSTRUCTURE HAS SHIFTED 1.5" TOWARD EAST AT SOUTH
ABUTMENT. SUPERSTRUCTURE HAS SHIFTED 1" NORTH OFF OF
WEST BEARING PAD AT PIER #7 MEASURED AT PAD. SHIFTING
AMOUNT APPARENTLY HAS NOT INCREASED FOR SEVERAL YEARS.
60.1 STAINING ON SOUTH ABUTMENT BREASTWALL
ADDITIONAL ITEM REFERENCE AND REMARKS
60.3 PINTLES ARE NOT CENTERED. MINOR CRACKING OF NORTH ABUTMENT PINTLE WITH DENTED STEEL PINTLE COVER BECAUSE OF CONTACT WITH BOTTOM SLAB OF BOX; CLEAR DISTANCE OF 2" BETWEEN PINTLE AND TOP OF SLAB AND 1" BETWEEN PINTLE AND BOTTOM OF SLAB AT NORTH ABUTMENT AT TIME OF INSPECTION.
MODERATE VEGETATION GROWTH ON EAST SIDE OF NORTH ABUTMENT BEARING SEAT.
MINOR MAP CRACKING OF SOUTH ABUTMENT PINTLE.
60.4,8 MINOR CRACKING WITH EFFLORESCENCE ON SIDES OF BACKWALLS. MINOR LEAKAGE THROUGH TRANSVERSE DIAPHRAGMS UNDER APPROACH SLAB AT NORTH ABUTMENT. MINOR TO MODERATE DETERIORATION OF VERTICAL JOINT MATERIAL AT EXPANSION JOINTS. DEVELOPING SPALL ON SOUTHEAST CORNER AT WEST SIDE OF NORTH ABUTMENT. MINOR SPALL WITH EXPOSED REBAR ON WEST SIDE OF NORTH ABUTMENT BACKWALL.
60.5,9 MODERATE EROSION AT NORTH ABUTMENT WITH ABUTMENT FOOTING AND NORTHEAST WINGWALL FOOTING EXPOSED. MINOR EROSION ALONG NORTHWEST WINGWALL. MODERATE EROSION OF SLOPE UNDER SPAN #1
AND #6. MINOR EROSION AT SOUTH ABUTMENT.
60.6 MINOR CRACKING WITH EFFLORESCENCE ON SOUTHEAST AND NORTHEAST WINGWALLS. SOUTHEAST WINGWALL HAS LOSS OF MORTAR. MINOR HORIZONTAL CRACKING OF CONCRETE ON NORTHWEST AND
SOUTHWEST WINGWALLS. MINOR CRACKING OF WINGWALL MASONRY MORTAR JOINTS WITH
EFFLORESCENCE. GEOLOGICAL SURVEY BENCHMARK ON TOP OF SOUTHWEST WINGWALL.
60.13,15,17 PORTION OF PIER RETAINING WALL FOOTING EXPOSED UP TO 1.5' AT PIERS #2 AND #4. MINOR CRACKING OF WEST GROUT PAD AT PIER #6 AND BOTH GROUT PADS AT PIER #7. MODERATE EROSION AT PIER #6 HAS EXPOSED UP TO 1.3' OF FOOTING AT EAST SIDE. MINOR EROSION AT EAST SIDE OF PIER #1. MINOR
VEGETATION GROWTH ON TOP OF PIER #4 RETAINING WALL.
222.3 MINOR CRACKING OF APPROACH RAIL MASONRY MORTAR JOINTS. TWO MISSING NUTS FROM STEEL-BACKED
TIMBER APPROACH RAIL ON NORTHEAST SIDE.
222.4,6 CRACKING ALONG PAVED OVER JOINTS BETWEEN APPROACH PAVEMENT AND APPROACH SLAB.
222.7 REFLECTIVE OBJECT MARKERS AND GUARDRAIL REFLECTORS ARE NOT PROVIDED. "PEDESTRIANS NOT
PERMITTED ON VIADUCT" SIGN AT SOUTH APPROACH.
36.D APPROACH GUARDRAIL ENDS ARE NOT SAFELY TERMINATED.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-182P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 20 18 33 30
HS 36 33 60 55
TYPE 3 41 37 68 62
TYPE 3S2 44 40 74 67
TYPE 3-3 46 42 77 70
DESIGN LOADING: HS20 (MS18)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-182P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 374 - NORTH CAROLINA (NC)
(202) STRUCTURE NAME: .......... LINN COVE VIADUCT (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 011 - AVERY
(204) STRUCTURE NUMBER: ..... 5140-182P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... LINN COVE BRANCH
(207) ROAD SECTION NO: .......... 182P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140182P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.99 MILES FROM U.S. ROUT
(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ BR2H7 (11) MILE POINT: ............................. 304.02 (KM PT 489.26)
(212) DRAWING NUMBERS: ....... BR2H7 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
6 - P/S CONCRETE CONTINUOUS
21 - SEGMENTAL BOX GIRDER
180.0 FT (54.9 M)
1,248.9 FT (380.7 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
3 - SPREAD FOOTING ON PILES
3 - SPREAD FOOTING ON PILES
2 - CONCRETE PRECAST PANELS
(44A) APPR. STR. MATERIAL: ........ 1 - CONCRETE
(44B) APPR. STR. TYPE: ................ 04 - TEE BEAM
(46) NO. OF APPROACH SPANS: .. 2
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 6 - BITUMINOUS
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 5 - HS20 (MS18) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 36.0 TONS (32.7 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 60.1 TONS (54.5 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 6/17 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-182P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 36°05'42.06" (51) CURB TO CURB WIDTH: ........... 34.3 FT (10.5 M)
(17) LONGITUDE: ......................... 81°48'45.12" (52) DECK WIDTH: ............................ 38.5 FT (11.7 M)
(19) DETOUR LENGTH: ............... 10 MI (16 KM) (32) APPR. ROADWAY WIDTH: ........ 30.0 FT (9.1 M)
(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 24.0 FT (7.3 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 3.0 FT (0.9 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 3.0 FT (0.9 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 2000 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2013 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 2200 (47) TOTAL HORIZ. CLEARANCE: .... 34.3 FT (10.5 M)
(115) YEAR OF FUTURE ADT: ..... 2033 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 2 - MOUNTED ON PARAPET
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 2 - CONCRETE/ALUMINUM
DESIGN TYPE: ........................ 1 - CONTINUOUS RAIL
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 3.04 FT (0.93 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1110
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
5 - Stable; scour within limits of
2 - REHAB/RECONSTRUCTION
C - MODERATE
$0
$0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
2000-SOUTH ABUTMENT BEARING PADS RESET.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
APPENDIX STRUCTURE NO. 5140-182P
PHOTOGRAPHS STRUCTURE NO. 5140-182P
FLOW
PHOTO #1 - LOOKING NORTH TOWARD BLOWING ROCK
PHOTO #2 - WEST (UPSTREAM) SIDE (PHOTO FROM 6/19/13
INSPECTION REPORT)
PHOTO #3 - GENERAL TOPSIDE VIEW
LOOKING SOUTH
PHOTO #4 - TYPICAL CRACKING AND
DETERIORATION OF WEARING SURFACE
PHOTO #5 - TYPICAL LONGITUDINAL AND TRANSVERSE CRACKING OF
WEARING SURFACE LOOKING SOUTH
PHOTO #6 - GENERAL VIEW OF SOUTH APPROACH
PHOTO #7 - CRACKING OF NORTH APPROACH PAVEMENT
PHOTO #8 - TYPICAL LONGITUDINAL CRACKING WITH VEGETATION
GROWTH IN WEARING SURFACE ALONG WEST CURB; NOTE
VEGETATION AND DEBRIS ACCUMULATION ALONG CURB LINE
PHOTO #9 - TYPICAL CRACKING OF WEARING SURFACE AT SCUPPERS
PHOTO #10 - TYPICAL CLOGGED DRAIN ALONG EAST CURB; NOTE
CRACKING OF WEARING SURFACE AT SCUPPERS
PHOTO #11 - CRACKING OF WEARING
SURFACE NEAR SOUTH END (PHOTO FROM
8/12/15 INSPECTION REPORT)
PHOTO #12 - TYPICAL EXPANSION JOINT,
SOUTH JOINT SHOWN; NOTE SOME MISSING
CAPS
PHOTO #13 - GENERAL VIEW OF NORTH
EXPANSION JOINT; NOTE DETERIORATION OF
WEARING SURFACE ADJACENT TO JOINT
PHOTO #14 - DISPLACED CURB STONE ALONG
EAST SIDE IN SPAN #1; SIMILAR CONDITION AT
SPAN #8 NEAR SOUTH ABUTMENT
PHOTO #15 - DISPLACED CURB STONE ALONG
WEST SIDE AT NORTH END OF STRUCTURE
PHOTO #16 - TYPICAL VEGETATION GROWTH
OVERHANGING WEST RAILING AND ALONG
CURBS AND SOUTH EXPANSION JOINT; NOTE
DISPLACEMENT OF CURB
PHOTO #17 - CLOSE-UP OF DISPLACED WEST
CURB STONE OF PREVIOUS PHOTO; NOTE
VEGETATION GROWTH
PHOTO #18 - TYPICAL VEGETATION GROWTH
ALONG CURBS AND OVERHANGING RAILING,
WEST CURB AND RAILING SHOWN
PHOTO #19 - DISPLACEMENT OF STRUCTURE
TOWARDS EAST, EAST SIDE AT SOUTH END
SHOWN
PHOTO #20 - CLOSE-UP OF PREVIOUS PHOTO;
NOTE MISSING END CAP OF RAILING
PHOTO #21 - CRACKING AND SPALLING OF CONCRETE CURB BEHIND
STONE MASONRY, WEST CURB SHOWN; NOTE CONDITION OCCURS IN
SEVERAL AREAS ALONG CURB
PHOTO #22 - MISSING ANCHOR BOLT NUT AT BASE OF WEST RAILING
PHOTO #23 - TYPICAL MISSING FASTENER
FOR RAIL TO RAILPOST CONNECTION; NOTE
CORROSION ON TOP RAIL FASTENER
PHOTO #24 - SPALL WITH EXPOSED REBAR
DUE TO LACK OF COVER, EAST SIDE OF SPAN
#8
PHOTO #25 - EXPOSED REBAR DUE TO LACK OF COVER, WEST SIDE
OF SPAN #8
PHOTO #26 - GENERAL UNDERSIDE VIEW OF SPAN #1 LOOKING SOUTH
PHOTO #27 - GENERAL VIEW OF EAST OVERHANG, NORTH END
PHOTO #28 - GENERAL UNDERSIDE VIEW OF SPAN #5 LOOKING NORTH
PHOTO #29 - GENERAL UNDERSIDE VIEW OF SPAN #6 LOOKING SOUTH
PHOTO #30 - GENERAL VIEW OF WEST OVERHANG, SOUTH END,
LOOKING NORTH
PHOTO #31 - CRACKING WITH EFFLORESCENCE ON UNDERSIDE OF
SOUTH APPROACH SLAB, WEST SIDE SHOWN (PHOTO FROM 8/12/15
INSPECTION REPORT)
PHOTO #32 - CRACKING WITH EFFLORESCENCE ON UNDERSIDE OF
SOUTH APPROACH SLAB, EAST SIDE SHOWN (PHOTO FROM 8/12/15
PHOTO #33 - UNDERSIDE VIEW OF NORTH APPROACH SLAB, WEST
SIDE (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #34 - DIAGONAL CRACKING WITH EFFLORESCENCE ON
UNDERSIDE OF NORTH APPROACH SLAB, EAST SIDE SHOWN (PHOTO
FROM 8/12/15 INSPECTION REPORT)
PHOTO #35 - MINOR SPALL AT SEAM BETWEEN SEGMENTS #70 AND
#71, APPROXIMATELY 5 FEET FROM CORNER BETWEEN WALL AND
DECK
PHOTO #36 - TOP SLAB UNDERSIDE AT ANCHOR BLOCK #83; NOTE
MINOR SPALLING ALONG CENTERLINE (PHOTO FROM 8/12/15
PHOTO #37 - MINOR SPALLING ALONG CONSTRUCTION JOINT ON TOP
SLAB INSIDE GIRDER SOUTH OF PIER #1 (PHOTO FROM 8/12/15
INSPECTION REPORT)
PHOTO #38 - SPALL AT CONSTRUCTION JOINT BETWEEN SEGMENTS
#137 AND #138 ON DECK UNDERSIDE (PHOTO FROM 8/12/15
PHOTO #39 - SEALED CRACKING ON DECK UNDERSIDE ON SOUTH END
OF SPAN #6 (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #40 - TYPICAL VIEW INSIDE OF BOX GIRDER, BOX GIRDER IN
SOUTH SPAN LOOKING NORTH SHOWN; NOTE GRAFFITI (PHOTO FROM
8/12/15 INSPECTION REPORT)
PHOTO #41 - FRACTURED AND SPALLED
GROUTING BLOCK COVER AT SEGMENT #9 IN
WEST SIDE OF SPAN #8 (SOUTH SPAN)
(PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #42 - MAP CRACKING ON DECK
UNDERSIDE IN SPAN #4, SEGMENT #48
(PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #43 - TYPICAL POST TENSIONING GROUTING SEAL, SEGMENT
#30, WEST SIDE SHOWN; NOTE SEALANT HAS PULLED OFF AND
RUSTED FROM BEHIND (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #44 - TOP OF PINTLE IN SPAN #5; NOTE GAP ON NORTH SIDE
LARGER THAN ON SOUTH SIDE (PHOTO FROM 8/12/15 INSPECTION
REPORT)
PHOTO #45 - GENERAL VIEW OF SEAM
BETWEEN SEGMENTS #59 AND #60 (PHOTO
FROM 8/12/15 INSPECTION REPORT)
PHOTO #46 - BROKEN POST TENSIONING CAP
ON WEST SIDE IN SEGMENT #61 (PHOTO
PHOTO #47 - TYPICAL CRACKING AT TOP OF
ANCHOR BLOCK #63 AT WEST SIDE;
CRACKING OF ANCHOR BLOCK #63; NOTE
SIMILAR CONDITION ON ANCHOR BLOCKS #62
AND #64; (PHOTO FROM 8/12/15 INSPECTION
REPORT)
PHOTO #48 - HONEYCOMBING AND SPALLING
ON BOTTOM OF ANCHOR BLOCK #71, WEST
SIDE (PHOTO FROM 8/12/15 INSPECTION
PHOTO #49 - 1.5 INCH TO 2 INCH CORE TAKEN AT WEST SIDE IN
SEGMENT #82 AND ANOTHER ON EAST SIDE; NOTE SPALL AROUND
CORE HOLE; (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #50 - SEVERAL CORE HOLES HAVE BEEN IDENTIFIED ON TOP
OF DECK AT EAST AND WEST SIDES IN SEGMENTS #83 AND #84
PHOTO #51 - EXPOSED TENDONS AT ANCHOR BLOCK #86 AND #87,
EAST SIDE
PHOTO #52 - TYPICAL CONDITION OF POST TENSION CAPS, WEST
SIDE OF PT #91 SHOWN (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #53 - BROKEN OFF GROUT PAD FOR ANCHORAGE ON WEST
SIDE OF SEGMENT #98 (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #54 - DIAGONAL CRACKING ON TOP ANCHOR BLOCK IN
SEGMENT 101; SIMILAR CRACKING IN SEGMENTS #102 AND #103 ON
EAST AND WEST SIDES (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #55 - FULL HEIGHT VERTICAL CRACKING ON EAST SIDE OF PT
#106 (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #56 - SPALLING ALONG CONSTRUCTION JOINT IN SPAN #3
BETWEEN PT #106 AND #107 (PHOTO FROM 8/12/15 INSPECTION
PHOTO #57 - DIAGONAL CRACKING ON WEST SIDE OF PT #109 (PHOTO
PHOTO #58 - SPALLING ON ANCHOR BLOCK #109, EAST SIDE (PHOTO
PHOTO #59 - EXPOSED VERTICAL REBAR ON EAST SIDE OF BOX
GIRDER AT PT #117 (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #60 - SPALL ON TOP FLANGE AND WEB OF WALL DIAPHRAGM
NEXT TO SEGMENT #120 (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #61 - SPALL ON WEST SIDE IN SEGMENT #121 (PHOTO FROM
PHOTO #62 - EXPOSED REBAR AT ANCHOR ON EAST SIDE OF BOX
GIRDER IN SOUTH SPAN NEAR ABUTMENT (PHOTO FROM 8/12/15
PHOTO #63 - TYPICAL DIAGONAL CRACKING
OF PIER #2 DIAPHRAGM, SOUTH FACE SHOWN
(PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #64 - SPALLS ON WALL DIAPHRAGM
NEXT TO SEGMENT #128; NOTE 2' X 2' SPALL
AREA IN WEB AT VOIDS FOR FUTURE POST
TENSIONING; NOTE ALSO SPALL ON TOP
PHOTO #65 - EXPOSED ENDS OF POST TENSIONING STRAINS
PHOTO #66 - CORROSION OF EXPOSED ENDS OF POST TENSIONING
STRAINS AND ANCHOR BLOCK
PHOTO #67 - CORROSION OF PRESTRESSING ANCHOR BLOCK
PHOTO #68 - TYPICAL CORROSION OF PRESTRESSING ANCHOR
BLOCK
PHOTO #69 - DEBRIS AND TRASH ACCUMULATION INSIDE GIRDER,
EAST SIDE SOUTH OF PIER #7 SHOWN (PHOTO FROM 8/12/15
INSPECTION REPORT)
PHOTO #70 - NORTH HATCH HAS BEEN WELDED SHUT (PHOTO FROM
PHOTO #71 - MISALIGNMENT OF NORTH
ABUTMENT PINTLE (PHOTO FROM 8/12/15
INSPECTION REPORT)
PHOTO #72 - TYPICAL DETERIORATION OF
DRAIN TROUGHS AT ABUTMENT EXPANSION
JOINTS, NORTH DRAIN TROUGH SHOWN
PHOTO #73 - WEST ELASTOMERIC BEARING PAD ON NORTH
ABUTMENT (PHOTO FROM 8/12/15 INSPECTION REPORT)
PHOTO #74 - ELASTOMERIC BEARING PAD EXTENDED TOWARDS
SOUTHWEST, EAST BEARING AT SOUTH ABUTMENT SHOWN; NOTE
ALSO GROUT BREAKING APART ALONG TOP OF PAD
PHOTO #75 - DETERIORATED GROUT ON TOP OF EAST ELASTOMERIC
BEARING PAD OF SOUTH ABUTMENT, WEST SIDE
PHOTO #76 - GENERAL VIEW OF NORTH ABUTMENT (PHOTO FROM
PHOTO #77 - TYPICAL TRANSVERSE CRACK
THROUGH NORTHWEST CHEEKWALL
PHOTO #78 - GENERAL VIEW OF PIER #1
(NORTH PIER), NORTH FACE
PHOTO #79 - GENERAL VIEW OF NORTHWEST
APPROACH PARAPET MASONRY; NOTE
GRAVEL ACCUMULATION IN SHOULDER
PHOTO #80 - GENERAL VIEW OF PIER #5,
SOUTH FACE
PHOTO #81 - BASE OF PIER #5 SOUTH SIDE
PHOTO #82 - GENERAL VIEW OF SOUTH FACE OF PIER #6
PHOTO #83 - CLOSE-UP VIEW OF BEARINGS
AND PINTLE ON PIER #6
PHOTO #84 - EXPOSED FOOTING AT PIER #6
DOWNHILL SIDE (PHOTO FROM 8/12/2015
PHOTO #85 - EROSION CHANNEL IN FRONT OF
PIER #7
PHOTO #86 - GENERAL VIEW OF PIER #7,
SOUTH FACE
PHOTO #87 - GENERAL VIEW OF SOUTH ABUTMENT; NOTE FILL
MATERIAL IN PLACE (PHOTO FROM 8/12/15 INSPECTION REPORT)