Bridge_Inspection_Report.pdf
PDF 5 MB Posted
- Attached to
- Catoctin Mountain Park Federal contract opportunity
- Solicitation number
- 693C73-18-B-000015
About this file
Bridge Inspection Report_STR#3220-002P
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ROBO_CATO_900(1).pdf | ||
| VETS-4212_-_Form.pdf | ||
| FP03_Eng_.pdf | ||
| NEPA_Document_EA.pdf | ||
| NEPA_Document_FONSI.pdf | ||
| Geotech_Report.pdf | ||
| NP-CATO_900(1)_Plans_Adv.pdf | ||
| NEPA_Document_CE.pdf | ||
| ADV_Bidders_Qualifications_Form.doc | DOC document | |
| IFB_Solicitation_NP-CATO_900(1)-_2nd_ADV.pdf | ||
| Synopsis,_CATO_900(1).pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
VISITOR CENTER BRIDGE
PARKING LOT ROAD OVER BLUE BLAZES CREEK
CATOCTIN MOUNTAIN PARK
LE
STRUCTURE NO. 3220-002P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 12/15/15
Report prepared by: SD
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 3220-002P
VISITOR CENTER BRIDGE INSPECTION DATE: 12/15/15
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... TRUSS - THRU NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. N/A STRUCT. TOTAL LENGTH: .. 30.4 FT (9.3 M)
DECK TYPE: ......................... STEEL PLATE (includes orthotropic) MAX. SPAN LENGTH: .......... 30.4 FT (9.3 M)
WEARING SURFACE: .......... OTHER DECK WIDTH: ...................... 11.8 FT (3.6 M)
ABUT. FOUNDATIONS: ........ N/A CURB TO CURB WIDTH: ..... 11.3 FT (3.4 M)
PIER FOUNDATION(S): ........ N/A YEAR BUILT:
ABUTMENT / PIER MAT'L: ... STEEL YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ YES
STRUCTURE HISTORY: ...... 2011-INSTALLED TO SPAN PREVIOUSLY FAILED BRIDGE.
LOCATION
CATOCTIN MOUNTAIN PARK MILE POINT:
STATE: ................................. MARYLAND LOCATION: US-15N, WEST ON MC-77 TO Catoctin
MOUNTAIN PARK, NORTH ON PARK CENTRAL FACILITY CARRIED: ............ PARKING LOT ROAD
ROAD, LEFT INTO BUS PARKING LOT.
FEATURE INTERSECTED: .. BLUE BLAZES CREEK
STRUCTURE EVALUATION SUMMARY
This Bailey-type temporary truss bridge provides vehicle access to a bus and overflow parking area, and is scheduled to be replaced with a permanent structure in the near future under Project PRA-CATO 900(1).
To help ensure motorist safety until the bridge is replaced, it is recommended that delineators be installed at the west side of the north approach.
INSPECTION TEAM: N. JANSEN, G. GOODLIN
CONDITION ASSESSMENT:
NATHANAEL JANSEN, FIELD TEAM LEADER 703-404-6255
REPORT REVIEW:
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 4/28/16
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3220-002P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
222.7 INSTALL DELINEATORS AT NORTH SIDE OF WEST APPROACH TO HELP ENSURE
MOTORIST SAFETY UNTIL BRIDGE IS REPLACED (SEE REMARKS BELOW).
2 EA
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ..
TOTAL ITEMIZED COSTS:
PRELIM. REHABILITATION TOTAL:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: This temporary bridge is scheduled to be replaced with a permanent structure in the near future under Project PRA-CATO 900(1).
FIELD INSPECTION REPORT STRUCTURE NO. 3220-002P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE
9 EXCELLENT CONDITION
8 VERY GOOD CONDITION - no problems noted.
7 GOOD CONDITION - some minor problems.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
58. DECK 7
1. DECK SLAB G
2. EXPANSION JOINTS N
3. WEARING SURFACE N
4. RIDEABILITY G
5. CURBS, SIDEWALKS, AND MEDIAN G
6. PARAPETS AND/OR RAILINGS G
7. DRAINS AND DRAINAGE F
8. UTILITIES G
9. DEFLECTION AND/OR VIBRATION G
10. OTHER N
59. SUPERSTRUCTURE 6
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10. ALIGNMENT
11. OTHER
60. SUBSTRUCTURE
ABUTMENTS
1. BREASTWALLS OR COLUMNS
2. PILE BENTS
3. CAPS AND/OR BEARING SEATS
4. BACKWALLS AND/OR BULKHEADS
5. FOUNDATIONS
6. WINGWALLS
7. WEEP HOLES
8. EXPANSION JOINTS
9. EROSION AND/OR SCOUR
10. SETTLEMENT OR DEFLECTION
11. SLOPE PROTECTION
12. OTHER (BEARING PADS)
PIER(S)
13. WALLS AND/OR COLUMNS
14. PILE BENTS
15. CAPS AND/OR BEARING SEATS
16. FOUNDATIONS
17. EROSION AND/OR SCOUR
18. SETTLEMENT OR DEFLECTION
19. OTHER
G N N F G F N N G G N
N N G G N F N N F G N F
N N N N N N N
58.1
58.5
58.6
58.7
59.1, 60.12
59.4
59.5
59.6
60.3
ITEM REFERENCE AND REMARKS
RAISED CORNERS AND MINOR RIPPLING OF STEEL DECK PLATE
EDGES.
BENT CURB ANGLE AT WEST END OF NORTH TRUSS.
TRUSSES SERVE AS BRIDGE RAILING. ORIGINAL TIMBER RAILING
STILL IN PLACE ALONG SOUTH SIDE OF BRIDGE; EAST END OF OLD
RAILING NOW RESTING ON BRIDGE FLOOR BEAM.
DEBRIS (PRIMARILY LEAVES) ALONG CURBS HINDERS DRAINAGE.
BRIDGE BEARINGS REST ON PADS. BEARINGS TYPICALLY OFF
CENTER OF PADS.
SOUTHEAST BEARING PAD RESTS ON A TYPICAL DECK PANEL ON
GRADE; CORNER OF DECK PANEL IS UNDERMINED (SEE 60.9).
MINOR TO MODERATE RUSTING AND MINOR PITTING OF
STRINGERS WITH SLIGHT SECTION LOSS ALONG PANEL SEAMS.
SEVERAL ANCHOR BOLTS NOT FULLY SEATED AT RANDOM
LOCATIONS.
GALVANIZED STEEL TRUSSES ARE IN GOOD CONDITION. MINOR
MISALIGNMENT OF TOP CHORD OF NORTH TRUSS.
MINOR DEBRIS ACCUMULATION IN LOWER PANEL POINTS.
NORTH LATERAL BRACE AT WEST ABUTMENT IS TORN FOR
LENGTH OF 9-1/2".
NORTH CONNECTION BOLT FOR BRACING NOT FULLY SEATED AT
WEST ABUTMENT.
MINOR DEBRIS ACCUMULATION AT BEARING AREAS.
FIELD INSPECTION REPORT STRUCTURE NO. 3220-002P
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION :9.
AVERAGE CLEAR OPENING8.
NORMAL VELOCITY7.
ADEQUACY OF OPENING6.
OTHER5.
WATERWAY OBSTRUCTIONS4.
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL 5
G P N G N
LOW
INSUFF
4 FT.
LACIAL TILL, CONCRETE, BOULDERS, CLA
222. APPROACHES 6
OTHER9.
ALIGNMENT8.
SIGNS7.
SETTLEMENT6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL3.
2. RELIEF JOINTS
APPROACH SLABS1. N
N N G G F F G N
223. RETAINING WALL 5
OTHER6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL F
N N F F N
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. N
N N N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
60.6 JERSEY BARRIERS USED AS WINGWALLS. MODERATE CRACKS
AND SPALLS IN BARRIERS. FULL HEIGHT CRACKS IN NORTH AND
SOUTH BARRIERS AT EAST END.
60.9 MINOR LOSS OF SUPPORT (STABILIZED SOIL) UNDER SOUTHEAST
BEARING PAD AND DECK PANEL.
61.2, 223.4,5 TEMPORARY BRIDGE SPANS ENTIRELY OVER ABUTMENTS OF
ORIGINAL BRIDGE. LARGE SCOUR HOLE AT DOWNSTREAM END OF
ORIGINAL BRIDGE HAS ALLOWED CONCRETE APRON TO BREAK
OFF; DEBRIS IS IN CHANNEL DOWNSTREAM FROM STRUCTURE.
CHANNEL FLOOR IS UNDERMINED UP TO 2-1/2' ACROSS ENTIRE
WIDTH.
SOUTHWEST WINGWALL OF ORIGINAL BRIDGE HAS UP TO 2' OF
UNDERMINING WITH SEVERAL LOWER STONES MISSING. FAILURE
OF SOUTHEAST WINGWALL WITH EXPOSED EMBANKMENT
REMAINS; SLOPE FAILURE AT THIS LOCATION HAS EXPOSED
POSTS FOR ORIGINAL BRIDGE.
TIMBER PLACED ALONG SOUTHEAST APPROACH TO HELP
MAINTAIN FILL. TREE AT SOUTHWEST BANK IS UNDERMINED BY UP
TO 3'.
222.6 UP TO 1" OF SETTLEMENT OF STABILIZED SOIL AT EAST
APPROACH; UP TO 1-1/2" AT WEST APPROACH.
222.7 MINOR COLLISION DAMAGE TO NORTHWEST OBJECT MARKER.
MISSING DELINEATORS AT NORTH SIDE OF WEST APPROACH.
222.8 APPROACH GRADE PRESENTS MINOR TO MODERATE INCLINE.
223.1 OLD MASONRY BRIDGE ABUTMENTS SERVE AS RETAINING WALLS
FOR TEMPORARY STRUCTURE. STONE AND MORTAR IN GOOD
CONDITION. SEE 61.2, 223.4, AND 223.5.
223.5 EAST RETAINING WALL (OLD MASONRY BRIDGE ABUTMENT) HAS
ROTATED TOWARDS CHANNEL. SCREW JACKS IN PLACE TO
PREVENT FURTHER ROTATION.
STRUCTURE LOAD RATING STRUCTURE NO. 3220-002P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 24 21 39 36
TYPE 3 21 19 34 31
TYPE 3S2 30 27 50 45
TYPE 3-3 41 37 68 61
DESIGN LOADING: UNKNOWN (H15 ASSUMED - SEE REMARKS)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: DESIGN LOADING IS UNKNOWN; ASSUMPTION IS BASED ON STRUCTURE TYPE, LOCATION, AGE, AND
CONDITION.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3220-002P
STRUCTURE IDENTIFICATION
(201) PARK: CATOCTIN MOUNTAIN PARK (1) STATE: ....................................... 243 - MARYLAND (MD)
(202) STRUCTURE NAME: .......... VISITOR CENTER BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 021 - FREDERICK
(204) STRUCTURE NUMBER: ..... 3220-002P (4) CITY/PLACE CODE: ................... 40965 - Thurmont
(205) NPS REGION: .................... 2 - NATIONAL CAPITAL (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... (6) FEATURES INTERSECTED:....... BLUE BLAZES CREEK
(207) ROAD SECTION NO: .......... 002P (7) FACILITY CARRIED: .................. PARKING LOT ROAD
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 3220002P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ US-15N, WEST ON MC-77 TO
(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ (11) MILE POINT:
(212) DRAWING NUMBERS: ....... (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 02 - COUNTY HIGHWAY AGENCY (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
3 - STEEL
10 - TRUSS - THRU
30.4 FT (9.3 M)
30.4 FT (9.3 M)
6 - N/A
6 - N/A
6 - N/A
6 - N/A
5 - STEEL PLATE (includes orthotropic)
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 9 - OTHER
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 23.6 TONS (21.4 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 39.4 TONS (35.7 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 12/15 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... YES
INSP. EVERY: 24 MONTHS - LAST INSP. : 12/15 (220) SPECIAL STUDY TYPE:
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3220-002P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 39°38'03.03" (51) CURB TO CURB WIDTH: ........... 11.3 FT (3.4 M)
(17) LONGITUDE: ......................... 77°27'02.44" (52) DECK WIDTH: ............................ 11.8 FT (3.6 M)
(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH:
(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH:
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER:
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER:
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 20 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2013 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 24 (47) TOTAL HORIZ. CLEARANCE: .... 11.1 FT (3.4 M)
(115) YEAR OF FUTURE ADT: ..... 2033 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A
(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL:
DESIGN TYPE:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT:
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK:
(54) MIN. VRT. UNDERCLEARANCE:
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL:
(36) TRAFFIC SAFETY FEAT: ... NNNN
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
5 - Stable; scour within limits of
1 - MAINTENANCE
D - MINOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
2011-INSTALLED TO SPAN PREVIOUSLY FAILED BRIDGE.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:77�27'02.44 http:39�38'03.03
APPENDIX STRUCTURE NO. 3220-002P
PHOTOGRAPHS STRUCTURE NO. 3220-002P
PHOTO #1 - LOOKING EAST
PHOTO #2 - SOUTH (DOWNSTREAM) SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW OF DECK LOOKING EAST
PHOTO #4 - COLLISION DAMAGE TO WEST END OF NORTH CURB
ANGLE
PHOTO #5 - TYPICAL RIPPLING OF DECK
PLATE EDGES
PHOTO #6 - TYPICAL DEBRIS ALONG CURB
LINE, SOUTH CURB SHOWN
PHOTO #7 - SETTLEMENT AT WEST APPROACH
PHOTO #8 - MISSING APPROACH DELINEATORS AT NORTH SIDE OF
WEST APPROACH
PHOTO #9 - COLLISION DAMAGE TO
NORTHWEST OBJECT MARKER
PHOTO #10 - MISALIGNMENT OF NORTH
TRUSS, LOOKING WEST
PHOTO #11 - GENERAL VIEW OF NORTHEAST BEARING AREA
PHOTO #12 - EROSION AT CORNER OF SOUTHEAST BEARING PAD
PHOTO #13 - GENERAL UNDERVIEW OF STRUCTURE; NOTE RUSTING
OF STRINGERS AND LATERAL BRACING
PHOTO #14 - TYPICAL RUST STAINING ON FLOOR BEAMS
PHOTO #15 - BOLT FOR BRACING NOT FULLY SEATED AT WEST
ABUTMENT FOR NORTH CONNECTION
PHOTO #16 - RUPTURE OF NORTH LATERAL BRACING AT WEST
ABUTMENT
PHOTO #17 - TYPICAL DEBRIS IN LOWER PANEL POINTS
PHOTO #18 - TYPICAL SCREW JACK IN PLACE TO PREVENT FURTHER
ROTATION OF OLD ABUTMENT RETAINING WALL, WEST WALL SHOWN
PHOTO #19 - SLOPE FAILURE AT SOUTHEAST CORNER; NOTE TIMBER
RAIL POST FOR ORIGINAL STRUCTURE COMPLETELY EXPOSED
PHOTO #20 - CLOSE-UP OF SLOPE FAILURE AT SOUTHEAST CORNER
PHOTO #21 - TYPICAL FULL HEIGHT CRACKS IN JERSEY BARRIER
WINGWALLS, NORTHWEST WINGWALL SHOWN
PHOTO #22 - CONCRETE APRON AT DOWNSTREAM END OF ORIGINAL
BRIDGE HAS BROKEN OFF; CONCRETE CHANNEL FLOOR IS
UNDERMINED UP TO 2-1/2'
PHOTO #23 - CONCRETE DEBRIS FROM APRON IS NOW IN CHANNEL
DOWNSTREAM OF STRUCTURE
PHOTO #24 - EROSION OF SOUTHWEST CHANNEL BANK WITH
UNDERMINED TREE
PHOTO #25 - LOOKING UPSTREAM FROM BRIDGE
PHOTO #26 - LOOKING DOWNSTREAM FROM BRIDGE
File details come from the government source that posted it.