ELEVATOR
ELEVATOR
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
DN
118.7023
0.0184
61.8518
STOP
STOP
S
ID
E
W A L K
RAMP
R A M P
BUMPER
BUMPER
AREA OF WORK @
ROOF
BLDG 10 BLDG 6
BLDG 1
BLDG 12
CLINICAL
BUILDING
ENTRANCE
LOCUST STREET
PARKING LOT
BLDG 1A
MAIN ENTRANCE
TAYLOR
STREET
PARKING LOT
L O
C U
S T
S
T R
E E
T
K
I
R M
A N
A
V E
B U R N S S T R E E T
E A S T T A Y L O R S T R E E T
BLDG 10
BLDG 1D
BLDG 5
BLDG 4
TEMPORARY LAY DOWN AREA & PEDESTRIAN PROTECTION
TEMPORARY
LAY DOWN
AREA
TEMPORARY
LAY DOWN
AREA
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A & 12
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-000
COVER SHEET
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
Not to Scale
Reference Site Plan
PROJECT
SITE
REMOVAL AND REPLACEMENT OF EXISTING ROOFING SYSTEMS FOR
BUILDING 1A AND BUILDING 12. REPLACEMENT OF EXISTING LIGHTNING
PROTECTION AFFECTED BY RE-ROOFING AND REPLACEMENT OF EXISTING
LIGHTNING PROTECTION SYSTEM AT ROOF PARAPETS w/ RECONNECTION
TO EXISTING MECHANICAL EQUIPMENT PROTECTIONS.
PROJECT DESCRIPTION
VICINITY MAP
DEDUCT ALTERNATES
1. PHASE 2
2. PHASE 3
PROJECT TEAM
FACILITY:
Department of Veterans Affairs VA Sierra Nevada Healthcare System Engineering Services 975 Kirman Avenue Reno, NV, 89502
Contact: Dan Davis P: 775.789.6671 E: Dan.Davis@va.gov
ARCHITECT
MA|Architects, Inc.
385 Van Ness Ave., Suite 110 Torrance, CA 90501
Contact: Steven A. McCaslin P: 424.302.5271 E: s.mccaslin@ma-architects.net
PROJECT DATA
PROJECT ADDRESS: 975 KIRMAN AVENUE
RENO, NV, 89502
BUIDING 1A
CONSTRUCTION TYPE: I (SPRINKLED)
STORIES: 3
BLDG. OCCUPANCY : BUSINESS
AREA OF WORK: APPROX 8,398 sf
BUIDING 12
CONSTRUCTION TYPE: I (SPRINKLED)
STORIES: 5
BLDG. OCCUPANCY : HEALTHCARE
AREA OF WORK: APPROX 28,759 SF
DEPARTMENT OF VETERANS AFFAIRS
VA Sierra Nevada Healthcare System
975 Kirman Avenue, Reno, NV, 89502
VA Project No. 654-21-104
REMOVE & REPLACE ROOFING AT BUILDINGS 1A & 12
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
10.08.2021 Final Construction Document
10/07/2021
APPLICABLE STANDARDS:
VA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).
VA PG 18-10 Architectural Design Manual (Aug. 1, 2014)
VA PG 18-10 Electrical Design Manual (Dec. 1, 2019)
2018 International Building Code (IBC) (Only when specifically referenced in VA Design Documents, see notes below)
2018 NFPA 101 Life Safety Code
2019 NFPA 241 Standard for Safeguarding Construction, Alteration, and Demolition Operations
2018 NFPA National Fire Codes with the exception of NFPA 5000 and NFPA 900
2020 NFPA 780 Standards for Installation of Lighting Protection Systems
Occupational, Safety and Health Administration (OSHA) Standards
2019 VA Seismic Design Requirements, H-18-8
2017 National Electrical Code (NEC) (NFPA 70)
2018 International Plumbing Code (IPC)
2019 Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.
2017 ASME Boiler and Pressure Vessel Code
2019 National Roofing Contractors Associations (NRCA) Roofing Manual: Membrane Roof Systems
ASME Code for Pressure Piping
2015 Architectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)
Building Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)
Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)
Energy policy Act of 2005 (EPAct)
DOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High- Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.
Federal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)
Executive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.
Executive Order 13514: Federal Leadership in Environmental, Energy, and Economic Performance (Oct. 5, 2009)
The Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01 00 00 of the VA Master Construction Specification.
Ventilation for Acceptable Indoor Air Quality - ASHRAE Standard 62.1 - 2016.
Safety Standard for Refrigeration Systems - ASHRAE Standard 15 - 2016.
Energy Standard for Buildings Except Low Rise Residential Buildings - ASHRAE 90.1 - 2016
AB
A
ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
ACP
AD
ACOUSTICAL CEILING PANEL
AREA DRAIN
ADDL ADDITIONAL
ADH
ADDITIONAL
ADHESIVE
ADJ
AFF
ADJACENT
AFG
ABOVE FINISH FLOOR
AFS
ABOVE FINISH GRADE
AGGR
ABOVE FINISH SLAB
ALUM
AGGREGATE
ALT
ALUMINUM
ANOD
ALTERNATE
APPROX
ANODIZED
ARCH
APPROXIMATE(LY)
ACS PNL ACCESS PANEL
ARCHITECT(URAL)
ASPH ASPHALT
AVG AVERAGE
BB
B
BULLETIN BOARD
BD BOARD
BTWN
BLDG
BETWEEN
BUILDING
BM
BOT
BENCHMARK
BOTTOM
BITUM BITUMINOUS
BOS BOTTOM OF STEEL
BRG BEARING
BSMT BASEMENT
CAB
C
CABINET
CB CATCH BASIN
CCT
CG
CUBICLE CURTAIN TRACK
CORNER GUARD
CEM
CER
CEMENT, CEMENTITIOUS
CERAMIC
CCTV CLOSED CIRCUIT TELEVISION
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CL
CLG
CLR
CMU
CNTR
COL
CONC
CONF
CONN
CONSTR
CONT
CONTR
CORR
CPT
CSK
CSP
CSWK
CU
CW
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER
COLUMN
CONCRETE
CONFERENCE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRUGATED
CARPET
COUNTERSUNK
COMBINATION STANDPIPE
CASEWORK
CUBIC
COLD WATER
D
D
DEPTH
DBL DOUBLE
DBL ACT DOUBLE ACTING
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIM PT DIMENSION POINT
DISP DISPENSER
DIST DISTANCE
DN DOWN
DR DRAIN
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAPERY TRACK
DWG DRAWING
DWGS DRAWINGS
(E)
E
EXISTING
EA EACH
EDR EQUIPMENT DRAWING
EG EDGE GUARD
EIFS EXTERIOR INSULATION FINISH SYSTEM
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EPB ELECTRICAL PANEL BOARD
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
EST ESTIMATE(D)
EWC ELECTRIC WATER COOLER
EXC EXCAVATED
EXH EXHAUST
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTERIOR
FURN FURNITURE
FXTR FIXTURE
G
G
GAS
H
H
HIGH
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GLU LAM GLUE LAMINATED
GLZ GLAZING
GR GRADE OR GRADING
GVL GRAVEL
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
ID
I
INSIDE DIAMETER
JAN
J
JANITOR
KG
K
KILOGRAM
L
L
LENGTH, LONG
M
M
METERS
(N)
N
NEW
P
QT
Q
QUARRY TILE
R
R
RISER
S SOUTH
T
T
TREAD
W
W
WEST
XFMR
X
TRANSFORMER
YD
Y
YARD
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HVAC HEATING-VENTILATION-AIR CONDITIONING
IN INCH
INCAND INCANDESCENT
INCL INCLUDE, INCLUDING
INFO INFORMATION
INSUL INSULATION
INTR INTERIOR
INV INVERT
IVT INTRAVENOUS TRACK
JST JOIST
JT JOINT
KIT KITCHEN
KPL KICK PLATE
KS KNEE SPACE
LAB LABORATORY
LAM LAMINATE, LAMINATION
LAV LAVATORY
LB POUND
LED LIGHT EMITTING DIODE
LF LINEAR FOOT
LG LENGTH
LIN LINEAR
LL LEAD LINED
LPT LOW POINT
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVR LOUVER
HW HOT WATER
S
MACH MACHINE
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MC MEDICINE CABINET
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MM MILLIMETERS
MO MASONRY OPENING
MOD MODULE, MODULAR
MTD MOUNTED
MTG MOUNTING
MVBL MOVABLE
MULL MULLION
NA NOT APPLICABLE
NAT NATURAL
NE NORTHEAST
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOICE REDUCTION COEFFICIENT
NTS NOT TO SCALE
NW NORTHWEST
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNEU PNEUMATIC
PNL PANEL
PNL BD PANEL BOARD
PNT PAINT
PORT PORTABLE
PP PUSH PLATE
PPM PARTS PER MILLION
PR PAIR
PRCST PRECAST
PREP PREPARATION
PREFAB PREFABRICATION
PRKG PARKING
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTN PARTITION
PTS PNEUMATIC TUBE STATION
PVC POLYVINYL CHLORIDE
PVG PAVING
PVMT PAVEMENT
PWR POWER
QTR QUARTER
QTY QUANTITY
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
RD ROOF DRAIN
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
REQT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAIN WATER LEADER
SAF
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SCRN SCREEN
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEP SEPARATION OR SEPARATE
SEP JT SEPARATION JOINT
SHT SHEET, SHEETING
SHWR SHOWER
SHV SHELVES, SHELVING
SIM SIMILAR
SK SINK
SMS SHEET METAL SCREW
SP SPACE, SPACED, SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS SANITARY SEWER
SSK SERVICE SINK
SST STAINLESS STEEL
ST STREET
STA STATION
STAG STAGGERED
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
STS SELF-TAPPING STEEL
SUSP SUSPENDED
SUSP CLG SUSPENDED CEILING
SVCE SERVICE
SW SOUTHWEST
SYMM SYMMETRICAL
SYST SYSTEM
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CONCRETE, TOP OF CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
THERM THERMAL
THK THICK, THICKNESS
THRES THRESHOLD
THRU THROUGH
TMPD GL TEMPERED GLASS
TO TOP OF
TOR TOP OF RAILING
TOS TOP OF STEEL
TOT TOTAL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
UC
U
UNDER COUNTER
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL UTILITY
W/ WITH
W/O WITHOUT
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WGL WIRE GLASS
WCHR WHEELCHAIR
WM WIRE MESH
WO WHERE OCCURS
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSP WET STANDPIPE
WT WEIGHT
WTHPRF WEATHERPROOF
WTRPRF WATERPROOF
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
CCR CARD CONTROL READER
BUR BUILT UP ROOFING SYSTEM
CT CERAMIC TILE
F
F/F FACE TO FACE
FA FIRE ALARM
FAS FIRE ALARM STATION
FB FLAT BAR
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FHY FIRE HYDRANT
FLAM FLAMMABLE
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FSB FOLDING SHOWER BENCH
FSTNR FASTENER
FT FOOT, FEET
OC
O
ON CENTER
PA PUBLIC ADDRESS
OA OVERALL
OD OUTSIDE DIAMETER
OFCI
OFOI
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OVHD OVERHEAD
OZ OUNCE
PART PARTIAL
PBD PARTICLEBOARD
PBX
PCF POUNDS PER CUBIC FOOT
PCI POUNDS PER CUBIC INCH
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PI POINT OF INTERSECTION
PL PLATE
PLAM PLASTIC LAMINIATE
P
PRIVATE TELEPHONE EXCHANGE
OWNER FURNISHED-CONTRACTOR INSTALLED
OWNER FURNISHED-OWNER INSTALLED
VAC
V
VACUUM
VB VALVE BOX
VCT VINYL COMPOSITION TYLE
VERT VERTICAL
VEST VESTIBULE
VIT VITREOUS
VP VENT PIPE
VOL VOLUME
VWC VINYL WALL COVERING
ABBREVIATIONS SYMBOLS
ANGLE
@ AT
C CENTER LINEL
Ø DIAMETER
= EQUAL
> GREATER THAN
< LESS THAN
± PLUS OR MINUS (TOLERANCE)
# POUND(S)
' FOOT OR FEET
" INCH OR INCHES
FOF FACE OF FINISH
OH OPPOSITE HAND
HSS HOLLOW STRUCTURAL STEEL
SA SUPPLY AIR
SYMBOLS LEGENDS
SHEET
NORTH IDENTIFIER
ELEVATION
IDENTIFIER
KEY NOTE TAG
GRID LINES
CALL-OUT
IDENTIFIER
PHOTOGRAPH LOCATIONS
(DEMOLITION SHEETS)
+? CEILING TAG
WALL TYPE TAG
Sheet #
Ref # On Sheet
WINDOW TAG#
REFER TO PARTITION DETAIL FOR LEGEND AND
FURTHER INFORMATION.
#X#
PARTITION TYPE
STUD WIDTH
FIRE RATING
SHEET
GENERAL NOTES:
1. THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS LISTED BY
THE "INDEX OF DRAWINGS".
2. FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS APPLICABLE ONLY TO THE
DRAWINGS OF ONE DISCIPLINE, REFER TO THE DRAWINGS OF THAT DISCIPLINE - SEE
"INDEX OF DRAWINGS".
3. APPLICABLE PORTIONS OF THE CODES, REGULATIONS, AND STANDARDS LISTED HERE ARE
INCORPORATED BY REFERENCE INTO THE REQUIREMENTS OF THIS CONTRACT AND
ESTABLISH MINIMUM REQUIREMENTS WITH WHICH THE WORK MUST COMPLY.
THIS PROJECT AND ALL PARTS OF THE WORK ASSOCIATED WITH THE PROJECT -
INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - SHALL COMPLY WITH ALL
APPLICABLE GOVERNING RULES, CODES, REGULATIONS, ORDINANCES, AND LAWS OF ALL
FEDERAL, STATE, DISTRICT, TERRITORIAL, AND LOCAL GOVERNMENT AUTHORITIES HAVING
JURISDICTION OVER THE DESIGN, CONSTRUCTION, AND OCCUPANCY OF THE PROJECT,
WHETHER LISTED BY THE CONTRACT DOCUMENTS OR NOT. NO PART OF THE CONTRACT
DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO AN
APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE, OR LAW.
NO PART OF THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT
WORK CONTRARY TO AN APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE,
OR LAW.
4. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
5. SCHEDULE CONSTRUCTION WORK HOURS TO ACCOMMODATE THE OPERATION OF THE
HOSPITAL / CLINIC / FACILITY. (COORDINATE WITH COR).
6. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH,
WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE
SET OF DRAWINGS, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE "INDEX
OF DRAWINGS". PARTIAL SETS OF DRAWINGS ARE INCOMPLETE.
THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY
THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURE
INSTALLATION REQUIREMENTS. SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH
OTHER, BIDS SHALL BE BASED ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND
QUANTITY OF WORK INDICATED. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL
BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
7. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND
ELEVATIONS ILLUSTRATE THE DESIGN INTENT. THE ARCHITECTURAL DRAWINGS
ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND LOCATION OF MANY, BUT
NOT ALL, EXPOSED ELEMENTS OF THE WORK. THE STRUCTURAL, MECHANICAL,
ELECTRICAL, PLUMBING, OTHER DRAWINGS, AND JOB SPECIFICATIONS ARE
SUPPLEMENTARY TO ARCHITECTURAL WORKING DRAWINGS. THE WORK DESCRIBED BY
THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON
DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURER INSTALLATION REQUIREMENTS.
SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH OTHER, BIDS SHALL BE BASED
ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND QUANTITY OF WORK INDICATED.
ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO
THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
8. THE DRAWINGS ARE INTENDED TO GRAPHICALLY ILLUSTRATE THE OVERALL NATURE OF
THE WORK; THE CONFIGURATION, ARRANGEMENT, AND LOCATION OF THE WORK AND ITS
PARTS; AND THE PHYSICAL DIMENSIONS OF THE WORK - THE DRAWINGS TAKE
PRECEDENCE OVER THE SPECIFICATIONS WITH RESPECT TO INFORMATION OF THIS
NATURE.
9. THE SPECIFICATIONS ARE INTENDED TO COMMUNICATE THE DETAILED PROPERTIES AND
QUALITY OF THE INDIVIDUAL MATERIALS, ASSEMBLIES, AND SYSTEMS THAT COMPRISE THE
WORK; THE FUNCTIONAL AND PERFORMANCE REQUIREMENTS FOR THE INDIVIDUAL PARTS
OF THE WORK; AND THE FABRICATION AND INSTALLATION REQUIREMENTS FOR INDIVIDUAL
PARTS OF THE WORK - THE SPECIFICATIONS TAKE PRECEDENCE OVER THE DRAWINGS
WITH RESPECT TO INFORMATION OF THIS NATURE.
10. PROPRIETARY PRODUCTS OR ASSEMBLIES UTILIZED AS "BASIS OF DESIGN":
• ON OCCASION, THE DRAWINGS MAY REFER TO A SINGLE PROPRIETARY PRODUCT
OR ASSEMBLY WHILE THE SPECIFICATIONS LIST TWO OR MORE ACCEPTABLE
MANUFACTURES AND/OR PRODUCTS, WHEN THIS OCCURS, THE PRODUCT OR
ASSEMBLY ILLUSTRATED BY THE DRAWINGS IS THE "BASIS OF DESIGN" PRODUCT OR
ASSEMBLY.
• THE DIMENSIONS, MOUNTING HEIGHTS, CLEARANCES, AND ACCESS REQUIREMENTS
OF SPECIFIED PRODUCTS AND ASSEMBLIES OTHER THAN THE "BASIS OF DESIGN"
MAY VARY FROM THAT SHOWN BY THE DRAWINGS.
• THE CONTRACTOR MAY UTILIZE ANY OTHER SPECIFIED PRODUCT OR ASSEMBLY IN
LIEU OF THE "BASIS OF DESIGN" PRODUCT OR ASSEMBLY, AS APPROVED BY
GOVERNMENT’S REPRESENTATIVE. HOWEVER, THE CONTRACTOR IS RESPONSIBLE
(AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT) FOR ALL COORDINATION AND
REVISIONS TO DIMENSIONS AND/OR DETAILS NECESSARY TO ACHIEVE THE SAME
FUNCTIONAL AND AESTHETIC DESIGN INTENT AS ILLUSTRATED BY THE "BASIS OF
DESIGN" SHOWN BY THE CONTRACT DOCUMENTS.
11. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR
EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS
BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IT IS NOT INTENDED
THAT THE CONTRACT DOCUMENTS INCLUDE EACH & EVERY SUB-SYSTEM AND/OR SUB-
COMPONENT NECESSARY TO FULLY AND PROPERLY COMPLETE THE WORK. SUB-SYSTEMS,
SUB-COMPONENTS OR DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE
MAY NOT BE SPECIFICALLY MENTIONED NOR SHOWN.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION OR RELATED WORK.
12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF
ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE
CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT
ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK
OF THAT PARTY.
CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR PATCHING THAT
MAY BE REQUIRED TO COMPLETE WORK OR TO MAKE ITS SEVERAL PARTS FIT TOGETHER.
13. THE ARCHITECT / ENGINEERS SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT
BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE ON
PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL
CONTRACTOR.
14. CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING, FITTING OR PATCHING THAT MAY BE REQUIRED TO COMPLETE WORK OR TO
MAKE ITS SEVERAL PARTS FIT TOGETHER. THE GENERAL CONTRACTOR IS RESPONSIBLE
TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND
SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS.
15. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A
CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE
CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO
COORDINATE WITH ALL "OTHER" CONTRACTORS PER REQUIREMENTS ESTABLISHED BY
OWNER, TENANT, OR BOTH, WHICH ARE UNDER SEPARATE CONTRACT WITH THE OWNER,
TENANT OR BOTH.
16. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DRAWINGS, CODE
REQUIREMENTS OR MANUFACTURER REQUIREMENTS WITHOUT THE PRIOR APPROVAL OF
THE OWNER AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S
EXPENSE. THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK REJECTED BY THE
ARCHITECT AS DEFECTIVE OR AS FAILING TO CONFORM TO THE CONTRACT DOCUMENTS
WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND WHETHER OR
NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS
OF CORRECTING SUCH REJECTED WORK, NOT TO BE REIMBURSED, INCLUDING
COMPENSATION FOR THE ARCHITECT'S ADDITIONAL SERVICES MADE NECESSARY
THEREBY.
17. FINAL COMPLETION CONSTRUCTION PHOTOS: THE CONTRACTOR WILL ENGAGE A
PROFESSIONAL PHOTOGRAPHER TO DOCUMENT THE COMPLETED WORK AFTER INITIAL
PUNCH WALK BY THE ARCHITECT. SUBMIT DIGITAL FILES TO ARCHITECT AS PART OF THE
PROJECT RECORD DOCUMENTS WITH LICENSE FOR USE OF IMAGES BY TEAM ASSOCIATED
WITH THE PROJECT.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A & 12
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-001
GENERAL NOTES, APPLICABLE
STANDARDS & SHEET INDEX
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
ARCHITECTURAL
AD-200 BUILDING 1A DEMOLITION PLAN
AD-201 BUILDING 12 LOWER ROOF DEMOLITION PLAN
AD-202 BUILDING 12 MIDDLE ROOF DEMOLITION PLAN
AD-203 BUILDING 12 UPPER ROOF DEMOLITION PLAN
AE-200 BUILDING 1A RENOVATION PLAN
AE-201 BUILDING 12 LOWER ROOF RENOVATION PLAN
AE-202 BUILDING 12 MIDDLE ROOF RENOVATION PLAN
AE-203 BUILDING 12 UPPER ROOF RENOVATION PLAN
AE-900 ROOF DETAILS BLDG 1A
AE-901 ROOF DETAILS BLDG 12
GENERAL
GI-000 COVER SHEET
GI-001 GENERAL NOTES, APPLICABLE STANDARDS & SHEET INDEX
GI-002 PROJECT PHASING
GI-003 REFERENCE FLOOR PLAN (6th FLOOR)
GI-100 EXISTING ROOF PLAN REFERENCE (BUILDING 1A)
GI-100A EXISTING PHOTOS (BUILDING 1A)
GI-101 EXISTING ROOF PLAN REFERENCE (BUILDING 12 LOWER ROOF)
GI-101A EXISTING PHOTOS (BUILDING 12 LOWER ROOF)
GI-102 EXISTING ROOF PLAN REFERENCE (BUILDING 12 UPPER ROOF)
GI-102A EXISTING PHOTOS (BUILDING 12 UPPER ROOF)
SHEET INDEXABBREVIATIONS
APPLICABLE STANDARDS
PROJECT GENERAL NOTES CONT. PROJECT GENERAL NOTES
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
DN
118.7023
0.0184
61.8518
STOP
RAMP
R A M P
BUMPER
PHASING LEGEND:
TEMPORARY CONSTRUCTION FENCE, GATE(S),
LOCKS BY CONTRACTOR.
BLDG 1
BLDG 12
BLDG 1A
BLDG 10
BLDG 1D
BLDG 5
BLDG 4
TEMPORARY LAY DOWN AREA AND PEDESTRIAN PROTECTION
(TO BE COORDINATED w/ LOCAL MUNICIPALITY)
CONTRACTOR TO SUBMIT PERMIT APPLICATION AND ATSSA CERTIFIED TRAFFIC CONTROL PLAN TO CITY OF
RENO PUBLIC WORKS PRIOR TO STARTING WORK (REFER TO SPEC SECTION 01 00 00).
PHASE 1
TEMPORARY
LAY DOWN
AREA AND
PEDESTRIAN
PROTECTION
TEMPORARY
LAY DOWN
AREA
AD-200
AD-203
SEQUENCE LEGEND:
Phase 1
Phase 2 (DEDUCT ALTERNATE #1)
Phase 4
Phase 3 (DEDUCT ALTERNATE #2)
PHASE 3
PHASE 2
PHASE 4
AREA: 3,470 SF
PERIMETER: 804 LF
AREA: 3,440 SF
PERIMETER: 723 LF
GENERAL PHASING PLAN NOTES:
PHASING PLANS ARE CONCEPTUAL IN NATURE AND DO NOT RELIEVE THE
CONTRACTOR OF PREPARING SITE SPECIFIC PHASING PLANS FOR
IMPLEMENTATION OF THE FULL SCOPE OF WORK DEFINED BY THE
CONTRACT DOCUMENTS. (REFER TO SPECIFICATION SECTION 01 00 0,
GENERAL REQUIREMENTS FOR CONTRACTOR PHASING RESPONSIBILITY)
CONTRACTOR TO SUBMIT FULLY DEVELOPED PHASING PLANS SHOWING
FULL SEQUENCE OF CONSTRUCTION.
A. CONTRACTOR SHALL TAKE WHATEVER STEPS ARE NECESSARY TO
PREVENT THE INTERRUPTION OF THE VAMC’S DELIVERY OF CARE TO
PATIENTS AT THE FACILITY AT ANY TIME.
B. REFER TO THE FOLLOWING SPECIFICATIONS FOR REQUIREMENTS
RELATED TO PHASING
1. SECTION 01 00 00 GENERAL CONDITIONS – PHASING
REQUIREMENTS
2. SECTION 01 35 26 SAFETY REQUIREMENTS – INFECTION
CONTROL REQUIREMENTS
C. WEEKENDS AND HOLIDAYS MAY BE AVAILABLE FOR CONTRACT
WORK OF PHASES SHOWN IF PERMITTED BY AND COORDINATED
WITH THE VAMC CONTRACTING OFFICER REPRESENTATIVE (COR).
D. ISOLATE EACH PHASE AS SHOWN WITH DUST PARTITION AND THE
PROVISION OF NEGATIVE AIR PRESSURIZATION. FOLLOW INFECTION
CONTROL PROVISIONS PER INFECTION AND DUST CONTROL PLANS,
NOTES AND REFERENCED SPECIFICATION.
E. CONTRACTOR SHALL ASSUME THE CONTINUED VAMC OCCUPANCY –
DURING NORMAL WORK HOURS – OF AREAS.
F. CONTRACTOR SHALL FULLY COMPLETE THE WORK INDICATED AND
REFERENCED FOR EACH PHASE OF CONSTRUCTION SHOWN.
G. CONTRACTOR SHALL PROVIDE FOR THE INCREMENTAL OCCUPANCY
OF EACH COMPLETED PHASE BY VAMC STAFF PRIOR TO BEGINNING
ON-SITE WORK IN THE NEXT CONSECUTIVE PHASE, UNLESS NOTED
OTHERWISE.
1. ONCE A PHASE OF WORK HAS BEEN COMPLETED AND
OCCUPIED BY VAMC, THE NEXT PHASE OF WORK MAY BEGIN
IN EARNEST.
H. CONTRACTOR SHALL COORDINATE MECHANICAL, ELECTRICAL, AND
PLUMBING (MEP) WORK INDICATED BY CONSTRUCTION DOCUMENTS
TO PROVIDE THE FULL EXTENT OF INFRASTRUCTURE
IMPROVEMENTS, MATERIAL ASSEMBLIES, SYSTEMS AND FINISHES
REQUIRED INDICATED OR REFERENCED TO PERMIT THE FULL AND
LEGAL OCCUPANCY OF EACH COMPLETED PHASE OF WORK.
I. CERTAIN INFRASTRUCTURAL IMPROVEMENTS REQUIRED FOR THE
PROJECT MUST OCCUR OUTSIDE OF THE DEPARTMENT LOCATION.
SUCH WORK MAY OCCUR DURING NORMAL VAMC WORK HOURS IF
THE FOLLOWING CONDITIONS ARE MET:
1. WORK DOES NOT OCCUR IN CORRIDORS USED BY PATIENTS
OR VISITORS
2. WORK DOES NOT INTERFERE WITH NORMAL VAMC
OPERATIONS
3. WORK IS COORDINATED WITH THE PROJECT COR.
J. ALL WORK PERFORMED WITHIN EXISTING CORRIDORS
THROUGHOUT THE FACILITY MUST BE PERFORMED OUTSIDE OF
NORMAL VAMC WORKING HOURS.
K. CONTRACTOR IS RESPONSIBLE FOR THE TIMELY COMPLETION OF
EACH PHASE OF CONSTRUCTION IN A COMPLETE AND
PROFESSIONAL MANNER.
L. REFER TO DEMOLITION AND NEW PLANS FOR ARCHITECTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL WORK INVOLVED WITH
EACH PHASE OF THE PROJECT.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A & 12
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-002
PROJECT PHASING
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
1" = 20'-0"
Phasing Plan
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
BS2D8
B6CD05
B6CD04
B6CD03
B6CD02
B6CD01
BS1D8
BS1D7
B6CD06
CS7D2
D
W
D
W
B6C10
B6259
B6139
B6193
B6134
B6193B
B6134B
B6138
B6203
B6125
B6257B6261A
B6263B
B6263A
B6184A
B6C03
B6C02
B6ESV
CS7
B6260
B6EGD
P12S9
P11S8
B6258
B61845C133C
B6C08
B6C09
B6184B
B6241B6242
B6124
B6261
B6256
B6255
B6247B6249
B6263
B6263CB6263D
B6251
B6253
B6244B6246B6248B6250B6252B6254
B6128
B6134A
B6128A
B6193A
B6195
B6136
B6197
B6199
B6140
B6201
B6142
B6146
B6205
B6104
B6127
B6127A
B6131A
B6131
B6135
B6133
B6135A
B6137A B6137
B6143
B6147A
B6147
B6184C
B6192 B6192A
B6194A
B6194
B6200
B6200A
B6204A
B6204
B6149
B6149A
B6150
B6150A
B6208B6208A
B6206A
B6206
BS2
B6184D
B6188
BS1
5CC12
B6404
B6C05
B6C06
B6C01
B6C07
B6260A
B6C10
B6259
B6139
B6193
B6134
B6193B
B6134B
B6138
B6203
B6125
B6257B6261A
B6263B
B6263A
B6184A
B6C03
B6C02
B6ESV
CS7
B6260
B6EGD
P12S9
P11S8
B6258
B61845C133C
B6C08
B6C09
B6184B
B6241B6242
B6124
B6261
B6256
B6255
B6247B6249
B6263
B6263CB6263D
B6251
B6253
B6244B6246B6248B6250B6252B6254
B6128
B6134A
B6128A
B6193A
B6195
B6136
B6197
B6199
B6140
B6201
B6142
B6146
B6205
B6104
B6127
B6127A
B6131A
B6131
B6135
B6133
B6135A
B6137A B6137
B6143
B6147A
B6147
B6184C
B6192 B6192A
B6194A
B6194
B6200
B6200A
B6204A
B6204
B6149
B6149A
B6150
B6150A
B6208B6208A
B6206A
B6206
BS2
B6184D
B6188
BS1
5CC12
B6404
B6C05
B6C06
B6C01
B6C07
B6260A
D N
U P
D N
U P
CORRIDOR
ELECTRICAL EQUIP
ELECTRICAL EQUIP
ANTE RM
ANTE RM
TOILET
TOILET
RED BAG
STORAGE
NOURISHMENT KITCHEN
STAFF
TOILET
STORAGESTORAGE
FEMALE
LOCKER
MALE
LOCKER
HAC
CORRIDOR
CORRIDOR
ELEVATOR
LOBBY
STAIR4
LINEN
CHUTE
ELEVATOR
LOBBY
GOLD
ELEVATOR
SILVER
ELEVATOR
GOLD
ELEVATOR
SILVER
ELEVATOR
STORAGE
FMS
DINING
TRAY CART
STORAGE
DAY RM
RECREATIONADL KITCHEN
CORRIDOR
CORRIDOR
NONFOOD
STORAGE
BATHBATH
COPY
CONFERENCE RM
NURSE
REPORT
NURSE
CLINICIAN
PHYS ASST
OFFICE
PSYCHOLOGIST
OFFICE
SOCIAL WORK
OFFICE
STAFF
LOUNGE
BATHBATH
MULTI
PURPOSE
OFFICE
ACTIVITIES
STAFF
STORAGE
PSYCHIATRIST
OFFICE
PSYCHIATRIST
OFFICE
PSYCHOLOGY
OFFICE
SOCIAL
WORKER
NURSING
SUPER
OFFICE
NURSE
STATION
SECLUSION
MEDICATION
SECLUSION
OFFICE
SOILED
UTILITY
TELE
EQUIP
CLEAN
LINEN
QUIET
CLEAN
UTILITY
TELE
QUIET
WASHER
DRYER
WORK RM HOUSE
STAFF
ONE BED
BATH
BATH
TWO BED
ONE BED
HAC
BATH
BATH ONE BED
GROUP
THERAPY
BATH
ONE BED
TELE
SUN DECK
TWO BED
BATH
BATH
TWO BED
TWO BED
BATH
BATH
TWO BED
ONE BED
BATH
ONE BED
BATH
TWO BEDBATH
BATH
TWO BED
STAIR2
STAIR
CLOSET
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
GENERAL STORAGE
CORRIDOR
ELECTRICAL EQUIP
ELECTRICAL EQUIP
ANTE RM
ANTE RM
TOILET
TOILET
RED BAG
STORAGE
NOURISHMENT KITCHEN
STAFF
TOILET
STORAGESTORAGE
FEMALE
LOCKER
MALE
LOCKER
HAC
CORRIDOR
CORRIDOR
ELEVATOR
LOBBY
STAIR4
LINEN
CHUTE
ELEVATOR
LOBBY
GOLD
ELEVATOR
SILVER
ELEVATOR
GOLD
ELEVATOR
SILVER
ELEVATOR
STORAGE
FMS
DINING
TRAY CART
STORAGE
DAY RM
RECREATIONADL KITCHEN
CORRIDOR
CORRIDOR
NONFOOD
STORAGE
BATHBATH
COPY
CONFERENCE RM
NURSE
REPORT
NURSE
CLINICIAN
PHYS ASST
OFFICE
PSYCHOLOGIST
OFFICE
SOCIAL WORK
OFFICE
STAFF
LOUNGE
BATHBATH
MULTI
PURPOSE
OFFICE
ACTIVITIES
STAFF
STORAGE
PSYCHIATRIST
OFFICE
PSYCHIATRIST
OFFICE
PSYCHOLOGY
OFFICE
SOCIAL
WORKER
NURSING
SUPER
OFFICE
NURSE
STATION
SECLUSION
MEDICATION
SECLUSION
OFFICE
SOILED
UTILITY
TELE
EQUIP
CLEAN
LINEN
QUIET
CLEAN
UTILITY
TELE
QUIET
WASHER
DRYER
WORK RM HOUSE
STAFF
ONE BED
BATH
BATH
TWO BED
ONE BED
HAC
BATH
BATH ONE BED
GROUP
THERAPY
BATH
ONE BED
TELE
SUN DECK
TWO BED
BATH
BATH
TWO BED
TWO BED
BATH
BATH
TWO BED
ONE BED
BATH
ONE BED
BATH
TWO BEDBATH
BATH
TWO BED
STAIR2
STAIR
CLOSET
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
GENERAL STORAGE
PHASING NOTES
PATIENT RELOCATION PHASING DURING CONSTRUCTION TO BE
DETERMINED BY VA STAFF. CONTRACTOR TO COORDINATE WITH
VA COR PRIOR TO STARTING WORK.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
Author
GI-003
REFERENCE FLOOR PLAN (6th FLOOR) 654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
1A & 12
Final Construction Document
N/A
1/8" = 1'-0"
6th Floor Reference Floor Plan
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
NORTH EXP.
ROOF
SOUTH EXP.
ROOF
MAIN ROOF
LOWER ROOF
STAIR TOWER
ROOF
PH
GI-100A
GI-100A
GI-100A 3
GI-100A
GI-100A
GI-100A
GI-100A
GI-100A8
GI-100A 9
GI-100A
DUCT
DOG
HOUSE
N.I.C.
LOWER CANOPY
N.I.C.
TYP.
D-EF1
AHU
#35AHU
#23
D-HV27
D-HV26
D-EF2
GI-100A
GI-100A
ROOF LEGEND:
LIGHTNING ROD
ROOF DRAIN
WATER FLOW DIRECTION
OUTLET DUPLEX
OUTLET FLOOR SINGLE
DISCONNECT SWITCH
VENT
LIGHT SWITCH
? PHOTOGRAPH LOCATIONS
WALKWAY PADS
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-100
EXISTING ROOF PLAN REFERENCE
(BUILDING 1A)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
KEY PLAN
1/8" = 1'-0"
Building 1A Roof (Existing)
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
EXISTING EXHAUST FAN &
ASSOCIATED CURB TO REMAIN
(PROTECT IN PLACE).
REMOVE & DISPOSE OF EXISTING
CMU BLOCKS.
EXISTING MECHANICAL UNIT
& CURB TO REMAIN
(PROTECT IN PLACE)
EXISTING LIGHTNING PROTECTION, TYP.
EXISTING AIR HANDLING UNIT
TO REMAIN (PROTECT IN PLACE)
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-100A
EXISTING PHOTOS (BUILDING 1A)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
Lightning Rods
Expansion Joint
Roof Drain and Over Flow
Stairs Tower
Center of Roof Looking South
Center of Roof Looking North
Electrical Outlet
Steel Frame
Lower Roof
Lower Roof Parapet
EXPANSION JOINT
LIGHTNING PROTECTION
STEEL SUPPORT FOR
MECHANICAL EQUIPMENT
OUTLET
ROOFING FINISH ON PARAPET
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
10.08.2021 Final Construction Document
1" = 80'-0"
Ladder at Lower Roof 1" = 80'-0"
North Exp. Roof
M
EC
H
AN
IC
AL
U N
IT
M
EC
H
AN
IC
AL
U N
IT
BUILDING
INTERIOR
M
ID
D
LE
R O O F
M
ID
D
LE R
O O F
AH
U
1A
AH
U
N.I.C
GI-101A
GI-101A
GI-101A
GI-101A
GI-101A
ROOF LEGEND:
LIGHTNING ROD
ROOF DRAIN
WATER FLOW DIRECTION
OUTLET DUPLEX
OUTLET FLOOR SINGLE
DISCONNECT SWITCH
VENT
LIGHT SWITCH
? PHOTOGRAPH LOCATIONS
WALKWAY PADS
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-101
EXISTING ROOF PLAN REFERENCE
(BUILDING 12 LOWER ROOF)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
1/8" = 1'-0"
Building 12 Lower Roof (Existing)
KEY PLAN
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
EXISTING WALKWAY PADS
EXISTING ROOF DRAIN
HIGH PARAPET WITH
TERMINATION BAR
MECHANICAL DUCTS EXISTING MECHANICAL UNIT
EXISTING METAL STAIRWAY
MECHANICAL UNITS
MECHANICAL DUCTS
MECHANICAL UNITS
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A121A & 12
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
Author
GI-101A
EXISTING PHOTOS (BUILDING 12
LOWER ROOF)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
High Parapet
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
10.08.2021 Final Construction Document
Mechanical Unit
Exhaust Fan
Mech. Unit Ducts to Building
Building 12 Lower Roof
MECHANICAL UNIT MECHANICAL UNIT
LOWER ROOF
BELOW
LOWER ROOF
BELOW
TRANSLUCENT
SKYLIGHT
EXISTING SINGLE PLY
MEMBRANE ROOFING
TYPICAL
MIDDLE ROOF
BELOW
MIDDLE ROOF
BELOW
LIGHTNING
ROD (TYPICAL)
GI-102A
GI-102A
GI-102A 3
GI-102A
GI-102A
GI-102A
GI-102A
GI-102A
GI-102A
GI-102A
GI-102A
B-HV1 B-HV2
AHU #4
AHU #3
AHU #5
B-HV5
B -H
V
B-HV4
B-HV3
B-EF6
B-EF5
B-EF8
B-EF7
B-EF2 B-EF3 B-EF4
ROOF LEGEND:
LIGHTNING ROD
ROOF DRAIN
WATER FLOW DIRECTION
OUTLET DUPLEX
OUTLET FLOOR SINGLE
DISCONNECT SWITCH
VENT
LIGHT SWITCH
? PHOTOGRAPH LOCATIONS
WALKWAY PADS
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-102
EXISTING ROOF PLAN REFERENCE
(BUILDING 12 UPPER ROOF)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
1/8" = 1'-0"
Building 12 Upper Roof (Existing)
KEY PLAN
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
(E) WALKWAY PADS
EXISTING METAL STAIRWAY
TO REMAIN (PROTECT IN PLACE)
EXISTING PRECAST CONCRETE
PARAPET TO REMAIN
(PROTECT IN PLACE).
EXISTING MECHANICAL
UNIT & CURB TO REMAIN
(PROTECT IN PLACE).
EXISTING ROOF DRAIN &
OVERFLOW DRAIN
ASSEMBLY TO REMAIN
(PROTECT IN PLACE)
LIGHTNING PROTECTION
SYSTEM AT PARAPET.
ROOFING FINISH AT CURB.
EXISTING MECHANICAL
UNIT & CURB TO REMAIN
(PROTECT IN PLACE).
LIGHTNING PROTECTION
SYSTEM AT PARAPET.
ROOFING FINISH AT CURB.
EXISTING SKYLIGHTS &
CURB TO REMAIN
(PROTECT IN PLACE).
ROOFING FINISH AT CURB.
EXISTING ROOF DRAIN &
OVERFLOW DRAIN
ASSEMBLY TO REMAIN
(PROTECT IN PLACE)
REMOVE EXISTING SHEET
METAL PARAPET COPING.
EXISTING SKYLIGHTS &
CURB TO REMAIN
(PROTECT IN
PLACE).
EXISTING ROOF DRAIN &
OVERFLOW DRAIN
ASSEMBLY TO REMAIN
(PROTECT IN PLACE)
EXISTING MECHANICAL
UNIT & CURB TO REMAIN
(PROTECT IN PLACE).
EXISTING SKYLIGHTS &
CURB TO REMAIN
(PROTECT IN PLACE).
REMOVE EXISTING SHEET
METAL PARAPET COPING.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
GI-102A
EXISTING PHOTOS (BUILDING 12
UPPER ROOF)
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
Upper Roof Access Door
Upper Roof Looking North
Upper Roof Mechanical Equipment Curb
Upper Roof Condenser Units
Upper Roof Anchored Units
Upper Roof Condenser and Lightning Rod
Upper Roof Lightning Rods
Upper Roof Skylight
Upper Roof Looking Down and Northeast
Upper Roof Looking Down and North
ROOFING FINISH ON PARAPET
Upper Roof Curb Condition
ROOF FINISH AT CURB
EXISTING MECHANICAL
UNIT & CURB TO REMAIN
(PROTECT IN PLACE).
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
UP
AD-200
ROOF AREA:
APPROX. 3,608 SF
ROOF AREA:
APPROX. 865 SF
ROOF AREA:
APPROX. 159 SF
DUCT
DOG
HOUSE
N.I.C.
LOWER CANOPY
N.I.C.
111111
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
ROOF AREA:
APPROX. 1,598 SF
ROOF AREA:
APPROX. 1,598 SF
103123
TYP.
ROOF AREA:
APPROX. 148 SF
D-EF1
AHU
#35
AHU
#23
D-HV27
D-HV26
D-EF2
137 138
TYPICAL
TYP.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
1A
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
AD-200
BUILDING 1A DEMOLITION PLAN
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
1/8" = 1'-0"
Building 1A Roof (Demolition)
KEY PLAN
1/4" = 1'-0"
Building 1A Roof Penthouse (Demolition)
Key Notes
101 REMOVE (E) SPRAYED APPLIED POLYURETHANE FOAM
ROOFING SYSTEM & ASSOCIATED FLASHINGS; PREP
CONCRETE ROOF SLAB FOR INSTALLATION OF NEW
ROOFING SYSTEM; SEAL ALL PENETRATIONS. PROTECT
EXISTING UTILITIES IN PLACE. (REFER TO SPEC SECTION 02
41 00).
103 GENERAL NOTE: EXISTING SHEET METAL COPING w/
EXISTING LIGHTNING PROTECTION SYSTEM @ PARAPET TO
BE REMOVED.
104 EXISTING 2" SEISMIC EXPANSION JOINT. REMOVE EXISTING
EXPANSION JOINT COVER SYSTEM & PREP FOR
INSTALLATION OF NEW ROOF EXPANSION JOINT COVER
ASSEMBLY.
105 EXISTING ROOF DRAIN ASSEMBLY TO REMAIN (PROTECT IN
PLACE). CLEAN FREE OF DEBRIS AS NECESSARY. CHECK
ALL DRAIN TRANSITIONS FOR ALL ROOFS FOR ANY SIGNS OF
LEAKS. REPAIR AS NECESSARY. APPROX. 10 LOCATIONS IN
THE PROJECT, VERIFY IN FIELD.
106 EXISTING EXHAUST FAN & ASSOCIATED CURB TO REMAIN
(PROTECT IN PLACE). REMOVE EXISTING UNISTRUT
ASSEMBLY FROM CURB SUPPORTING DISCONECT SWITCH &
RELOCATE DISCONNECT SWITCH PER RENOVATION PLANS.
107 REMOVE (E) WALKWAY PADS.
109 REMOVE & DISPOSE OF EXISTING CMU BLOCKS.
110 EXISTING SIDE WALL OVERFLOW DRAIN & DOWNSPOUT TO
REMAIN (PROTECT IN PLACE). CLEAN FREE OF DEBRIS AS
NECESSARY. CHECK ALL DRAIN TRANSITIONS FOR ALL
ROOFS FOR ANY SIGNS OF LEAKS. REPAIR AS NECESSARY.
APPROX. 6 LOCATIONS IN THE PROJECT, VERIFY IN FIELD.
111 REMOVE SPRAYED APPLIED POLYURETHANE FOAM FROM
EXISTING ELECTRICAL OUTLETS; CLEAN AS NECESSARY.
112 NOT USED. 100
113 EXISTING DISCONNECT SWITCH ON UNISTRUT ASSEMBLY TO
BE RELOCATED.
114 EXISTING AIR HANDLING UNIT TO REMAIN (PROTECT IN
PLACE); PROVIDE FILTER COVERS @ INTAKES DURING
DEMOLITION OF ROOF SYSTEM TO PREVENT COLLECTION OF
DEBRIS. REMOVE ANY FILTERS PROVIDED AT THE
COMPLETION OF PROJECT.
116 GENERAL NOTE: EXISTING LIGHTNING PROTECTION DEVICES
AT MECHANICAL UNITS TO REMAIN (PROTECT IN PLACE).
DISCONNECT FROM MAIN LINES.
117 EXISTING LIGHTNING PROTECTION DOWN CONDUCTOR TO
REMAIN (PROTECT IN PLACE).
118 EXISTING STEEL BEAM SUPPORTS TO REMAIN (PROTECT IN
PLACE).
119 EXISTING ROOF DOWNSPOUT (PROTECT IN PLACE).
121 EXISTING ELEVATED DUCTWORK TO REMAIN (PROTECT IN
PLACE). REMOVE EXISTING SUPPORTS AS NECESSARY FOR
INSTALLATION OF NEW ROOFING SYSTEM.
122 EXISTING METAL STAIRWAY TO REMAIN (PROTECT IN PLACE).
123 EXISTING SAFETY RAILING TO REMAIN (PROTECT IN PLACE).
124 EXISTING ROOF ACCESS LADDER TO REMAIN w/ BOTTOM
SUPPORTS RE-ANCHORED TO EXISTING CONCRETE WALL.
125 EXISTING MECHANICAL UNIT & CURB TO REMAIN (PROTECT
IN PLACE).
129 GENERAL NOTE: PROTECT IN PLACE EXISTING ELECTRICAL
OUTLETS, SWITCHES, DISCONNECT SWITCHES, ELECTRICAL
PANELS, FIRE DEPARTMENT CONNECTIONS, FIRE ALARMS
AND OTHER ELECTRICAL EQUIPMENTS ON WALLS.
133 EXISTING ELECTRICAL OUTLET TO REMAIN (PROTECT IN
PLACE).
135 EXISTING 2" SEISMIC EXPANSION JOINT. REMOVE SPRAYED
APPLIED POLYURETHANE FOAM ROOFING SYSTEM &
ASSOCIATED WALL COUNTER FLASHING; PREP FOR
INSTALLATION OF NEW ROOF EXPANSION JOINT COVER
ASSEMBLY.
137 GENERAL NOTE: REMOVE ANY SIGNAGE PRIOR TO STARTING
WORK. SAVE AND REINSTALL AFTER WORK IS COMPLETED.
138 GENERAL NOTE: CONTRACTOR TO PERFORM LEAD AND
ASBESTOS SAMPLING ON ROOFING MATERIALS TO BE
DEMOLISHED TO CONFIRM THAT THERE IS NO HAZARDOUS
MATERIALS PRESENT.
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
BUILDING
INTERIOR
M
ID
D
LE
R O O F
M
ID
D
LE R
O O F
U P
ROOF AREA:
APPROX. 1,213 SF
ROOF AREA:
APPROX. 336 SF
ROOF AREA:
APPROX. 302 SF
ROOF AREA:
APPROX. 1,619 SF
ROOF AREA:
APPROX. 2,524 SF
ROOF AREA:
APPROX. 727 SF
ROOF AREA:
APPROX. 189 SF
108115
TYP.
115 115
108126
TYP.
GENERATOR
BLDG ROOF
N.I.C.
121121
AHU #1A
AHU #1
BEF-1
TYP.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
AD-201
BUILDING 12 LOWER ROOF
DEMOLITION PLAN
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
1/8" = 1'-0"
Building 12 Lower Roof (Demolition)
KEY PLAN
Key Notes
102 REMOVE (E) PVC ROOFING SYSTEM, ASSOCIATED RIGID
INSULATION & ASSOCIATED FLASHINGS DOWN TO THE
PRIMARY STRUCTURAL ROOF DECK. PREP AND REPAIR
SUBSTRATE FOR INSTALLATION OF NEW ROOFING; SEAL
ALL PENETRATIONS. PROTECT EXISTING UTILITES IN
PLACE. (REFER TO SPEC SECTION 02 41 00).
105 EXISTING ROOF DRAIN ASSEMBLY TO REMAIN (PROTECT
IN PLACE). CLEAN FREE OF DEBRIS AS NECESSARY.
CHECK ALL DRAIN TRANSITIONS FOR ALL ROOFS FOR ANY
SIGNS OF LEAKS. REPAIR AS NECESSARY. APPROX. 10
LOCATIONS IN THE PROJECT, VERIFY IN FIELD.
107 REMOVE (E) WALKWAY PADS.
108 EXISTING SHEET METAL PARAPET COPING TO BE
REMOVED FOR INSTALLATION OF NEW ROOFING SYSTEM.
114 EXISTING AIR HANDLING UNIT TO REMAIN (PROTECT IN
PLACE); PROVIDE FILTER COVERS @ INTAKES DURING
DEMOLITION OF ROOF SYSTEM TO PREVENT COLLECTION
OF DEBRIS. REMOVE ANY FILTERS PROVIDED AT THE
COMPLETION OF PROJECT.
115 EXISTING ROOF DRAIN & OVERFLOW DRAIN ASSEMBLY TO
REMAIN (PROTECT IN PLACE). CLEAN FREE OF DEBRIS AS
NECESSARY. CHECK ALL DRAIN TRANSITIONS FOR ALL
ROOFS FOR ANY SIGNS OF LEAKS. REPAIR AS
NECESSARY. APPROX. 42 IN THE PROJECT, VERIFY IN
FIELD.
120 GENERAL NOTE: REMOVE PIPE & CONDUIT SUPPORTS AS
NECESSARY FOR INSTALLATION OF NEW ROOFING
SYSTEM.
121 EXISTING ELEVATED DUCTWORK TO REMAIN (PROTECT IN
PLACE). REMOVE EXISTING SUPPORTS AS NECESSARY
FOR INSTALLATION OF NEW ROOFING SYSTEM.
122 EXISTING METAL STAIRWAY TO REMAIN (PROTECT IN
PLACE).
126 REMOVE (E) ROOFING MEMBRANE, TERMINATION BAR &
SEALANT @ PRECAST GFRC COPING.
127 EXISTING SKYLIGHTS & CURB TO REMAIN (PROTECT IN
PLACE).
128 EXISTING MECHANICAL EXHAUST FAN & ASSOCIATED
CURB TO REMAIN (PROTECT IN PLACE); DISCONNECT
FROM SUPPORTS AS NECESSARY TO INSTALL NEW
ROOFING SYSTEM.
129 GENERAL NOTE: PROTECT IN PLACE EXISTING
ELECTRICAL OUTLETS, SWITCHES, DISCONNECT
SWITCHES, ELECTRICAL PANELS, FIRE DEPARTMENT
CONNECTIONS, FIRE ALARMS AND OTHER ELECTRICAL
EQUIPMENTS ON WALLS.
132 EXISTING ELECTRICAL OUTLETS MOUNTED ALONG WALL
TO REMAIN (PROTECT IN PLACE).
134 EXISTING MECHANICAL UNIT & STEEL SUPPORT TO
REMAIN (PROTECT IN PLACE).
136 REMOVE (E) ROOFING MEMBRANE, TERMINATION BAR &
SEALANT @ STUCCO ASSEMBLY.
137 GENERAL NOTE: REMOVE ANY SIGNAGE PRIOR TO
STARTING WORK. SAVE AND REINSTALL AFTER WORK IS
COMPLETED.
138 GENERAL NOTE: CONTRACTOR TO PERFORM LEAD AND
ASBESTOS SAMPLING ON ROOFING MATERIALS TO BE
DEMOLISHED TO CONFIRM THAT THERE IS NO
HAZARDOUS MATERIALS PRESENT.
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
BUILDING
INTERIOR
MIDDLE ROOF
M
ID
D
LE R
O O F
ROOF AREA:
APPROX. 1,088 SF
ROOF AREA:
APPROX. 940 SF
TYP.
TYP.
TYP.
137 138
TYP.
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
AD-202
BUILDING 12 MIDDLE ROOF
DEMOLITION PLAN
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
KEY PLAN
Key Notes
000 EXITING PLAN
102 REMOVE (E) PVC ROOFING SYSTEM, ASSOCIATED RIGID
INSULATION & ASSOCIATED FLASHINGS DOWN TO THE
PRIMARY STRUCTURAL ROOF DECK. PREP AND REPAIR
SUBSTRATE FOR INSTALLATION OF NEW ROOFING; SEAL
ALL PENETRATIONS. PROTECT EXISTING UTILITES IN
PLACE. (REFER TO SPEC SECTION 02 41 00).
108 EXISTING SHEET METAL PARAPET COPING TO BE
REMOVED FOR INSTALLATION OF NEW ROOFING SYSTEM.
115 EXISTING ROOF DRAIN & OVERFLOW DRAIN ASSEMBLY TO
REMAIN (PROTECT IN PLACE). CLEAN FREE OF DEBRIS AS
NECESSARY. CHECK ALL DRAIN TRANSITIONS FOR ALL
ROOFS FOR ANY SIGNS OF LEAKS. REPAIR AS
NECESSARY. APPROX. 42 IN THE PROJECT, VERIFY IN
FIELD.
126 REMOVE (E) ROOFING MEMBRANE, TERMINATION BAR &
SEALANT @ PRECAST GFRC COPING.
137 GENERAL NOTE: REMOVE ANY SIGNAGE PRIOR TO
STARTING WORK. SAVE AND REINSTALL AFTER WORK IS
COMPLETED.
138 GENERAL NOTE: CONTRACTOR TO PERFORM LEAD AND
ASBESTOS SAMPLING ON ROOFING MATERIALS TO BE
DEMOLISHED TO CONFIRM THAT THERE IS NO
HAZARDOUS MATERIALS PRESENT.
1/8" = 1'-0"
Building 12 - Middle Roof (Demolition)
Rev. Date Description
07.07.2021 35% Schematic Design
08.13.2021 90% Construction Document
09.14.2021 100% Construction Document
B4100
B4C01
BATH
CORRIDOR
B4C01
SLOPE 1/2" / 1'-0" )
(TYPICAL)
AD-203
114 114
118 130
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
ROOF AREA:
APPROX. 15,845 SF
ROOF AREA:
APPROX. 1,098 SF
130115
115 115
128 128 128
122122
115 115
126 TYP.
126TYP.
TYP.
126 TYP.
126 TYP.
126 TYP.
B-HV1 B-HV2
AHU #4
AHU #3
AHU #5
B-HV5
B -H
V
B-HV4
B-HV3
B-EF6
B-EF5
B-EF8
B-EF7
B-EF2 B-EF3 B-EF4
137 138
TYPICAL
VA Project Number
Building Number
Drawing Number
Project Title
Location:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
REMOVE & REPLACE
ROOFING AT BLDGS 1A & 12
SO/jc
AD-203
BUILDING 12 UPPER ROOF
DEMOLITION PLAN
654-21-104
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV, 89502
10.08.2021
Final Construction Document
N/A
KEY PLAN
Key Notes
102 REMOVE (E) PVC ROOFING SYSTEM, ASSOCIATED RIGID
INSULATION & ASSOCIATED FLASHINGS DOWN TO THE
PRIMARY STRUCTURAL ROOF DECK. PREP AND REPAIR
SUBSTRATE FOR INSTALLATION OF NEW ROOFING; SEAL
ALL PENETRATIONS. PROTECT EXISTING UTILITES IN
PLACE. (REFER TO SPEC SECTION 02 41 00).
103 GENERAL NOTE: EXISTING SHEET METAL COPING w/
EXISTING LIGHTNING PROTECTION SYSTEM @ PARAPET TO
BE REMOVED.
105 EXISTING ROOF DRAIN ASSEMBLY TO REMAIN (PROTECT IN
PLACE). CLEAN FREE OF DEBRIS AS NECESSARY. CHECK
ALL DRAIN TRANSITIONS FOR ALL ROOFS FOR ANY SIGNS
OF LEAKS. REPAIR AS NECESSARY. APPROX. 10 LOCATIONS
IN THE PROJECT, VERIFY IN FIELD.
107 REMOVE (E) WALKWAY PADS.
109 REMOVE & DISPOSE OF EXISTING CMU BLOCKS.
110 EXISTING SIDE WALL OVERFLOW DRAIN & DOWNSPOUT TO
REMAIN (PROTECT IN PLACE). CLEAN FREE OF DEBRIS AS
NECESSARY. CHECK ALL DRAIN TRANSITIONS FOR ALL
ROOFS FOR ANY SIGNS OF LEAKS. REPAIR AS NECESSARY.
APPROX. 6 LOCATIONS IN THE PROJECT, VERIFY IN FIELD.
114 EXISTING AIR HANDLING UNIT TO REMAIN (PROTECT IN
PLACE); PROVIDE FILTER COVERS @ INTAKES DURING
DEMOLITION OF ROOF SYSTEM TO PREVENT COLLECTION
OF DEBRIS. REMOVE ANY FILTERS PROVIDED AT THE
COMPLETION OF PROJECT.
115 EXISTING ROOF DRAIN & OVERFLOW DRAIN ASSEMBLY TO
REMAIN (PROTECT IN PLACE). CLEAN FREE OF DEBRIS AS
NECESSARY. CHECK ALL DRAIN TRANSITIONS FOR ALL
ROOFS FOR ANY SIGNS OF LEAKS. REPAIR AS NECESSARY.
APPROX. 42 IN THE PROJECT, VERIFY IN FIELD.
116 GENERAL NOTE: EXISTING LIGHTNING PROTECTION
DEVICES AT MECHANICAL UNITS TO REMAIN (PROTECT IN
PLACE). DISCONNECT FROM MAIN LINES.
118 EXISTING STEEL BEAM SUPPORTS TO REMAIN (PROTECT IN
PLACE).
120 GENERAL NOTE: REMOVE PIPE & CONDUIT SUPPORTS AS
NECESSARY FOR INSTALLATION OF NEW ROOFING SYSTEM.
122 EXISTING METAL STAIRWAY TO REMAIN (PROTECT IN
PLACE).
126 REMOVE (E) ROOFING MEMBRANE, TERMINATION BAR &
SEALANT @ PRECAST GFRC COPING.
127 EXISTING SKYLIGHTS & CURB TO REMAIN (PROTECT IN
PLACE).
128 EXISTING MECHANICAL EXHAUST FAN & ASSOCIATED CURB
TO REMAIN (PROTECT IN PLACE); DISCONNECT FROM
SUPPORTS AS NECESSARY TO INSTALL NEW ROOFING
SYSTEM.
129 GENERAL NOTE: PROTECT IN PLACE EXISTING ELECTRICAL
OUTLETS, SWITCHES, DISCONNECT SWITCHES, ELECTRICAL
PANELS, FIRE DEPARTMENT CONNECTIONS, FIRE ALARMS
AND OTHER ELECTRICAL EQUIPMENTS ON WALLS.
130 REMOVE LIGHTNING PROTECTION SYSTEM ALONG INSIDE
OF PARAPET. EXISTING PRECAST CONCRETE PARAPET &
BIRD DETERRENT SYSTEM TO REMAIN (PROTECT IN PLACE).
131 EXISTING SMOKE VENTS (PROTECT IN PLACE).
134 EXISTING MECHANICAL UNIT & STEEL SUPPORT TO REMAIN
(PROTECT IN PLACE).
137 GENERAL NOTE: REMOVE ANY SIGNAGE PRIOR TO
STARTING WORK. SAVE AND REINSTALL AFTER WORK IS
COMPLETED.
138 GENERAL NOTE: CONTRACTOR TO PERFORM LEAD AND
ASBESTOS SAMPLING ON ROOFING MATERIALS TO BE
DEMOLISHED TO CONFIRM THAT THERE IS NO HAZARDOUS
MATERIALS…