About this file

This solicitation seeks calibration, temperature uniformity testing, and system accuracy testing services for furnaces and ovens located throughout a manufacturing area. The scope of work involves providing all labor, equipment, and test equipment necessary to perform calibrations, temperature uniformity surveys, and system accuracy tests on approximately 160 instruments and 19 furnaces and ovens in accordance with AMS 2750E. Reporting requirements include submitting electronic and hard copy data sheets on a monthly basis by the 15th that document equipment used, model and serial numbers, and "as found" and "left" calibration settings. The proposed contract is set aside for small businesses and has a one year base period and two option years. The solicitation was issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to CALIBRTIONS AND UNIFORMITY TESTING, newest first.
File Type Posted
W911PT-20-Q-0094.pdf PDF
15-4143 dated 4-27-2020.txt TXT text file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCOPE OF WORK for W16H1F929701GY, PR 64657144

CALIBRATIONS & UNIFORMITY TESTS

1. Purpose: Provide calibrations to instrumentation (approximately 160 units). Perform System Accuracy Tests (SATs) and Temperature Uniformity Surveys (TUSs) on Heat Treating Furnaces and Curing Ovens used throughout the Watervliet Arsenal’s manufacturing areas totaling 19 (See attached list).

2. General Requirements: The contractor shall provide all labor, equipment, test equipment necessary to perform all Calibrations (Cals), SATs and TUSs. The frequency of tests on each individual furnace can fluctuate depending on the performance of the furnace and whether or not it passes required testing.

3. Contractor Furnished Items: All instruments used by the contractor will be certified using measurement standards traceable to the National Institute of Standards and Technology (NIST), contractor will provide letter of certification for prove out.

4. Requirements: The contractor shall follow AMS 2750E Aerospace Material Specification for all guidelines. Each device will be inspected and calibrated to respective manufacturer’s recommendations.

5. Reporting Requirements: All Calibrations, SATs, TUSs, will be annotated per AMS 2750E, all data sheets will be provided monthly electronically and hard copy form contractor to the Watervliet Arsenal Support Division Metal Processing General Foreman or his assignee by the 15th of the month. The data sheet developed and provided by the contractor shall be in Mircosoft Excel format compatible with the latest version at WVA. Required fields will be equipment used to perform all Cals, SATs, TUSs, model numbers, serial numbers, as found and left settings as calibrated (beginning values prior to calibrations and ending values after calibrations). The exact format style, and layout of the data sheet is determined by the contractor but will be approved by the COR/Technical POC.

6. CONTRACT LENGTH: Contract shall be for a length of one base year and two option years for the government to extend

LIST OF FURNACES FOR CALIBRATION AND SURVEYS

1. WV12204 (SFE) STANDARD FUEL ENGINEERING ELECTRIC PIT FURNACE

2. WV12206 (SFE) ELECTRIC PIT FURNACE

3. WV09470 LINDBERG ELECTRIC FURNACE

4. WV12762 WISCONSIN OVER ELECTRIC BOX

5. WV12834 WISCONSIN OVER ELECTRIC BOX

6. WV12805 LINDBERG ELECTRIC AUSTENITIZING PIT FURNACE

7. WV12700 PYROTECH SERVICES AUSTENITIZING PIT FURNACE

8. WV12833 BEAVERMATIC ELECTRIC AUSTENITIZING FURNACE

9. WV12809 IPSEN VACUUM BOTTOM LOADING FURNACE

10. WV12396 LINDBERG ELECTRIC BOX FURNACE – WELD SHOP

11. WV12881 WISCONSIN ELECTRIC FURNACE

12. WV12721 JL BECKER ENDOTHERMIC GENERATOR, 2000 CFH

13. SURFACE COMBUSTION PIT FURNACE

FURNACES FOR JUST CALIBRATION

1. WV11770 SELAS CONTINUOUS GAS BURNERS

2. WV12700 PYROTECH SERVICES CARBURIZER FURNACE

3. WV12224 WISCONSIN TOP LOADING OVEN – COMPOSITE AREA

4. WV12223 WISCONSIN TOP LOADING OVEN – COMPOSITE AREA

5. WV12007 LINDBERG ELECTRIC PIT FURNACE – BLDG 135 VERTICAL HEAT TREAT

6. PH ANALYZER METTLER TOLEDO M300 - SWAGE AREA

7. WV11920 WELLMAN PIT FURNACE, MODEL 40D423179 - CHROME

8. WV12586 WELLMAN PIT FURNACE, MODEL 40D423179 - CHROME

9. WV11737 NEW ENGLAND OVEN & FURNACE BOX OVEN -CHROME