6-Volt Battery System Specifications.docx
DOCX document 21 KB Posted
- Solicitation number
- 7604
- Issued by
-
Department of Agriculture Forest Service
About this file
The provided document contains the technical specifications for a 6-Volt battery system required to power microwave systems under a federal contract opportunity. The key details are:
The battery system must consist of three 2-Volt lead acid/glass mat battery cells configured into a single 6-Volt assembly, with a minimum capacity of 860 amp hours for 8 hours at 1.75 Volts. The 6-Volt modules must have front facing terminals and be configurable up to a 48-Volt system. All higher-voltage configurations must meet or exceed Uniform Building Code 97 Seismic Zone 4 specifications and include a mounting base, interconnecting cables, and other necessary hardware. 48-Volt configurations must be less than 30-inches in width and 70-inches in height, including the mounting base.
The related federal contract opportunity is a solicitation (Solicitation Number 7604) from the Department of Agriculture Forest Service for (48) Six Volt Battery Modules configured into Six (6) 48-Volt systems, with associated hardware, to power microwave systems. Interested vendors are directed to review the RFQ, BOM, and technical specifications for full order details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ART Contract Language Template.pdf | ||
| BOM_12760424Q0130.xlsx | XLSX spreadsheet | |
| Configuration Drawiing.JPG | JPG image | |
| RFQ_12760424Q0130_1.pdf | ||
| USDA Security Language.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USFS Land Mobile Radio
Minimum Technical Specifications
6-Volt Battery System
· Three 2-Volt cells modularized into a single 6-Volt assembly. Lead acid/glass mat battery cells, capable of a minimum capacity of 860 amp hours for 8 hours at 1.75 Volts
· 6-Volt modules shall have front facing terminals
· 6-Volt modules must be configurable up to a 48 Volt system
· All higher-voltage configurations of 6-V modules must be affixed so as to meet or exceeding Uniform Building Code 97 Seismic Zone 4 specifications
· All higher voltage configurations of 6-V modules must include a mounting base, interconnecting cables and any other hardware necessary for specified system functionality
· 48-Volt configurations must be less than 30-inches in width and less than 70-inches in height, including mounting base and excluding any optional accessories