This is a General Services Administration (GSA) Request for Lease Proposals (RLP) for office space in Danville/Martinsville, Virginia. The Government seeks to lease 1,000 to 1,700 rentable square feet of general office space at or above ground level, with a 10-year initial full term, a 3-year firm term, and 90-day termination rights. Proposals must be received by March 19, 2026, at 2:00 P.M. EST via email to mary.harris@gsa.gov. The space must be located within a delineated area in Danville/Martinsville and meet modern building standards with sound construction and a facade of stone, marble, brick, stainless steel, or aluminum. The Government does not anticipate using tenant improvements or building-specific amortized capital. One reserved surface parking space is required. Award will be made to the responsible offeror submitting the lowest priced technically acceptable offer based on price per square foot using ANSI/BOMA Z65.1-2017 occupant area standards, with a HUBZone small business concern price evaluation preference available under FAR 52.219-4.

Offerors must submit a completed GSA Form 3626 (U.S. Government Lease for Real Property – Short Form), Supplemental Lease Requirements document, GSA 3517A General Clauses, fire protection and life safety submittals, AutoCAD or scaled floor plans, SAM registration, EISA compliance information, proof of ownership or control, authorization to submit on behalf of the owner if applicable, signing authority documentation, small business subcontracting plans if applicable, FAR 52.204-24 telecommunications representation, and offeror's routine cleaning and disinfection rate. The space must comply with accessibility standards, fire safety codes including means of egress and fire suppression systems, HVAC standards (72°F ±3° heating, 75°F ±3° cooling), janitorial services, and energy efficiency requirements under EISA. The lessor is responsible for all utilities, building maintenance, and providing signage, ceiling tile replacement, and suite entrance accessibility upgrades as part of shell rent. NAICS code 531120 applies, with small business size standards per SBA guidelines.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GSA TEMPLATE R103 (5/25)

GSA REQUEST

FOR LEASE

PROPOSALS

NO. 5VA0808

Danville/ Martinsville, VA

Offers due by 03/19/2026

In order to be considered for award, offers conforming to the requirements of the RLP shall be received no later than 2:00 P.M. EST on the date above. See “Receipt Of Lease Proposals” herein for additional information.

This Request for Lease Proposals ("RLP") sets forth instructions and requirements for proposals for a Lease described in the RLP documents. Proposals conforming to the RLP requirements will be evaluated in accordance with the Basis of Award set forth herein to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions herein.

The information collection requirements contained in this Solicitation/Contract, that are not required by regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No.

3090-0086.

SMALL RLP

TABLE OF CONTENTS

SECTION 1 - STATEMENT OF REQUIREMENTS

1.01 GENERAL INFORMATION (SMALL) (OCT 2023)

1.02 AMOUNT AND TYPE OF SPACE AND LEASE TERM (SLAT) (OCT 2020)

1.03 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE

STANDARD (OCT 2023)

SECTION 2 - SOLICITATION PROVISIONS

2.01 INCORPORATED SOLICITATION PROVISIONS (SMALL) (OCT 2024)

2.02 FLOOD PLAINS (OCT 2022)

SECTION 3 - ELIGIBILITY AND PREFERENCES FOR AWARD

3.01 BASIS OF AWARD (OCT 2023)

3.02 SEISMIC SAFETY – MODERATE SEISMICITY (MAY 2025) INTENTIONALLY DELETED

3.03 SEISMIC SAFETY – HIGH SEISMICITY (MAY 2025) INTENTIONALLY DELETED

3.04 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (MAY 2025)

3.05 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS – RLP (SMALL) (OCT 2023) INTENTIONALLY

DELETED

3.06 HUBZONE SMALL BUSINESS CONCERN PRICE PREFERENCE WAIVER (SMALL) (OCT 2023)

SECTION 4 - HOW TO OFFER

4.01 RECEIPT OF LEASE PROPOSALS (SMALL) (OCT 2023)

4.02 PROPOSAL CONTENTS FOR SMALL LEASES (OCT 2024)

4.03 FIRE PROTECTION AND LIFE SAFETY SUBMITTALS (SMALL) (OCT 2020)

4.04 EISA SUBMITTALS (SMALL) (SEP 2015)

4.05 SWING SPACE - RLP (OCT 2022) INTENTIONALLY DELETED

RLP NO. 5VA0808, PAGE 1 GSA TEMPLATE R103 (10/24)

SECTION 1 - STATEMENT OF REQUIREMENTS

1.01 GENERAL INFORMATION (SMALL) (OCT 2023)

A. This Request for Lease Proposals (RLP) sets forth instructions and requirements for proposals for a Lease described in the RLP documents.

The Government will evaluate proposals conforming to the RLP requirements in accordance with the Basis of Award set forth below to select an Offeror for award. The Government will award the Lease to the selected Offeror, subject to the conditions below.

B. Included in the RLP documents are the GSA Form 3626 (U.S. GOVERNMENT LEASE FOR REAL PROPERTY (Short Form)) which serves as an offer form and lease contract award document Supplemental Lease Requirements document, and GSA 3517A, General Clauses.

C. The Offeror's executed GSA Form 3626 shall constitute a firm offer. No Lease shall be formed until the Lease Contracting Officer (LCO) executes the GSA Form 3626 and delivers a signed copy to the Offeror.

D. Offeror may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA, in the entity name that owns and/or leases the Space to GSA.

1.02 AMOUNT AND TYPE OF SPACE AND LEASE TERM (SLAT) (OCT 2020)

The Space shall be located in a modern quality Building of sound and substantial construction with a facade of stone, marble, brick, stainless steel, aluminum or other permanent materials in good condition and acceptable to the LCO. If not a new Building, the Space offered shall be in a Building that has undergone, or will complete by occupancy, modernization, or adaptive reuse for the Space with modern conveniences.

CITY, STATE DANVILLE/ MARTINSVILLE, VIRGINIA

DELINEATED AREA Starting Point: Intersection of Figsboro Rd and Dryer Store Rd. South on Dryer Store Rd to Chatham Rd. East on

Chatham Rd to Stoney Mountain Rd. South Stoney Mountain Rd to 58. Southeast on 58 continuing on Westover Dr to Moorefield Bridge Rd. North on Moorefield Bridge Rd to Mt Cross Rd. East on Mt Cross Rd to Mill Creek Rd. East on Mill Creek Rd to Walnut Creek Rd. North on Walnut Creek Rd to Orphanage Rd. East on Orphanage Rd to Franklin Turnpike. South on Franklin Turnpike to 29. South on 29 to the Dan River. Following the Dan River South to the Virginia/ North Carolina State Line. West on the Virginia/ North Carolina State Line to Moorehead Ave. North on Moorehead Ave to 220/ Greensboro Rd. North on 220/ Greensboro Rd to the Smith River. North on the Smith River to Beaver Creek. Following Beaver Creek Northeast to Kings Mountain Rd. North on Kings Mountain Rd to Figsboro Rd. North on Figsboro Rd to the Starting Point (intersection with Dryer Store Rd).

SPACE TYPE(S) OFFICE

MINIMUM SQ. FT. (ABOA) 1,000

MAXIMUM SQ. FT. (ABOA) 1,700

INITIAL FULL TERM 10 YEARS

TERMINATION RIGHTS 90 DAYS

INITIAL FIRM TERM 3 YEARS

ADDITIONAL REQUIREMENTS -SPACE MUST BE AT OR ABOVE GROUND LEVEL

- THE GOVERNMENT DOES NOT ANTICIPATE USING TENANT IMPROVEMENTS (TI) OR BUILDING SPECIFIC AMORTIZED CAPITAL

(BSAC) FOR THIS PROCUREMENT.

- 1 RESERVED SURFACE PARKING SPACE

1.03 NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) CODE AND SMALL BUSINESS SIZE STANDARD (OCT 2023)

A. The North American Industry Classification System (NAICS) code for this acquisition is 531120 (Exception).

B. The small business size standard for the applicable NAICS code is found at HTTPS://WWW.SBA.GOV/DOCUMENT/SUPPORT-TABLE-SIZE-

STANDARDS STANDARDS.

https://www.sba.gov/document/support-table-size-standards https://www.sba.gov/document/support-table-size-standards

RLP NO. 5VA0808, PAGE 2 GSA TEMPLATE R103 (5/25)

SECTION 2 - SOLICITATION PROVISIONS

2.01 INCORPORATED SOLICITATION PROVISIONS (SMALL) (OCT 2024)

GSA 3516A, SOLICITATION PROVISIONS (For Simplified Acquisition of Leasehold Interests in Real Property) are attached to this RLP.

2.02 FLOOD PLAINS (OCT 2022)

A. A Lease will not be awarded for any offered Property located within a 1-percent-annual-chance floodplain (formerly referred to as 100-year floodplain) unless the Government has determined that there is no practicable alternative. An Offeror may offer less than its entire site in order to exclude a portion of the site that falls within a floodplain, so long as the portion offered meets all the requirements of this RLP and does not impact the Government’s full use and enjoyment of the Premises. If an Offeror intends that the offered Property that will become the Premises for purposes of this Lease will be something other than the entire site as recorded in tax or other property records the Offeror shall clearly demarcate the offered Property on its site plan/map submissions and shall propose an adjustment to property taxes on an appropriate pro rata basis. For such an offer, the Government may determine that the offered Property does not adequately avoid development in a 1-percent-annual-chance floodplain.

B. In addition, a Lease will not be awarded for any offered Property adjacent to 1-percent-annual-chance floodplain, where such an adjacency would, as determined by the Government, restrict ingress or egress to the Premises in the event of a flood, unless there is no practicable alternative.

RLP NO. 5VA0808, PAGE 3 GSA TEMPLATE R103 (10/24)

SECTION 3 - ELIGIBILITY AND PREFERENCES FOR AWARD

3.01 BASIS OF AWARD (OCT 2023)

A. Lowest Price Technically Acceptable Approach. The Lease will be awarded to the responsible Offeror whose offer conforms to the requirements of this RLP and Lease documents and is the lowest priced technically acceptable offer submitted, based on the lowest price per square foot, according to the ANSI/BOMA Z65.1-2017 definition for Occupant Area, which means “the total aggregated area used by an Occupant before Load Factors are applied, consisting of Tenant Area and Tenant Ancillary Area.” The Method A – Multiple Load Factor Method shall apply.

B. Price evaluation will be based on the lowest price per square foot, according to the ANSI/BOMA Z65.1-2017 definition for Occupant Area, which means “the total aggregated area used by an Occupant before Load Factors are applied, consisting of Tenant Area and Tenant Ancillary Area.”

The Method A – Multiple Load Factor Method shall apply.

C. See FAR Clause 52.219-4 Notice of Price Evaluation Preference for HUBZone Small Business Concerns, as listed under the attached GSA

3517A, General Clauses.

D. If an offer contains terms taking exception to or modifying any Lease provision, the Government will not be under any obligation to award a Lease in response to that offer.

3.02 SEISMIC SAFETY – MODERATE SEISMICITY (MAY 2025) INTENTIONALLY DELETED

3.03 SEISMIC SAFETY – HIGH SEISMICITY (MAY 2025) INTENTIONALLY DELETED

3.04 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (MAY 2025)

A. The Energy Independence and Security Act (EISA) establishes requirements for Government leases relating to energy efficiency standards and potential cost-effective energy efficiency and conservation improvements.

B. If the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, Offerors are required to include in their lease proposal an agreement to renovate the Building for all energy efficiency and conservation improvements that it has determined would be cost effective over the Firm Term of the Lease, if any, prior to acceptance of the Space

C. The term "cost effective" means an improvement that will result in substantial operational cost savings to the landlord by reducing electricity or fossil fuel consumption, water, or other utility costs. The term "operational cost savings" means a reduction in operational costs to the landlord through the application of Building improvements that achieve cost savings over the Firm Term of the Lease sufficient to pay the incremental additional costs of making the Building improvements.

D. Instructions for obtaining an ENERGY STAR® Label are provided at

HTTPS://WWW.ENERGYSTAR.GOV/BUILDINGS/BUILDING_RECOGNITION (use “Portfolio Manager” to apply). The ENERGY STAR® BUILDING UPGRADE MANUAL and BUILDING UPGRADE VALUE CALCULATOR are tools which can be useful in considering energy efficiency and conservation improvements to Buildings.

E. If the offered Space is not in a Building that has earned the ENERGY STAR® Label within one year prior to the due date for final proposal revisions, the successful Offeror will be excused from performing any agreed-to energy efficiency and conservation renovations if it obtains the Energy Star Label prior to the Government’s acceptance of the Space

A. If no improvements are proposed, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. If such explanation is unreasonable, the offer may be rejected.

3.05 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS – RLP (SMALL) (OCT 2023) INTENTIONALLY DELETED

3.06 HUBZONE SMALL BUSINESS CONCERN PRICE PREFERENCE WAIVER (SMALL) (OCT 2023)

A HUBZone small business concern (SBC) Offeror may elect to waive the price evaluation preference provided in the “Basis of Award” paragraph. In such a case, no price evaluation preference shall apply to the evaluation of the HUBZone SBC.

https://www.energystar.gov/buildings/building_recognition/building_certification/how_apply https://www.energystar.gov/sites/default/files/buildings/tools/EPA_BUM_Full.pdf https://www.energystar.gov/buildings/tools-and-resources/building-upgrade-value-calculator

RLP NO. 5VA0808, PAGE 4 GSA TEMPLATE R103 (10/24)

SECTION 4 - HOW TO OFFER

4.01 RECEIPT OF LEASE PROPOSALS (SMALL) (OCT 2023)

A. Offeror is authorized to transmit its lease proposal as an attachment to an email. Offeror's email shall include the name, address and telephone number of the Offeror, and identify the name and title of the individual signing on behalf of the Offeror. Offeror's signed Lease proposal must be saved in a generally accessible format (such as portable document format (pdf)), which displays a visible image of all original document signatures and must be transmitted as an attachment to the email. Only emails transmitted to, and received at, the GSA email address identified in the RLP will be accepted. Offeror submitting a Lease proposal by email shall retain in its possession, and make available upon GSA's request, its original signed proposal. Offeror choosing not to submit its proposal via email may still submit its lease proposal, by United States mail, or other express delivery service of Offeror's choosing.

B. In order to be considered for award, offers conforming to the requirements of the RLP shall be received no later than 2:00 P.M. EST on the date specified below at the following designated office and address, or email address:

Date: March 19, 2026 Email Address: mary.harris@gsa.gov

C. Offers sent by United States mail or hand delivered (including delivery by commercial carrier) shall be deemed late if delivered to the address of the office designated for receipt of offers after the date and time established for receipt of offers.

D. Offers transmitted through email shall be deemed late if received at the designated email address after the date and time established for receipt of offers unless it was received at the initial point of entry to the Government infrastructure not later than 5:00 p.m. one Working Day prior to the date specified for receipt of proposals.

E. Offers may be also deemed timely if there is acceptable evidence to establish that it was received at the Government installation designated for receipt of proposals and was under the Government’s control prior to the time set for receipt of proposals; or if it was the only proposal received.

B. There will be no public opening of offers, and all offers will be confidential until the Lease has been awarded. However, the Government may release proposals outside the Government such as to support contractors to assist in the evaluation of offers. Such Government contractors shall be required to protect the data from unauthorized disclosure.

4.02 PROPOSAL CONTENTS FOR SMALL LEASES (OCT 2024)

The proposal shall consist of the following documents:

DOCUMENT NAME OR DESCRIPTION

U.S. Government Lease For Real Property (Short Form) (GSA Form 3626), completed and signed by Offeror Supplemental Lease Requirements, initialed by Offeror GSA 3517A, General Clauses, initialed by Offeror Fire Protection and Life Safety information and documents (See applicable Fire Protection and Life Safety paragraphs) Auto CAD or scaled floor plans delineating the Premises proposed by the Offeror Registration in the System for Award Management (SAM) prior to the Lease Award Date, including completion of all required representations and certifications. This registration service is free of charge.

EISA compliance information (See applicable Energy Independence and Security Act paragraphs) Evidence of ownership or control of Building or site, including a copy of the Property deed Authorization from the ownership entity to submit an offer on the ownership entity’s behalf, if the offeror is not the owner of the Property Proof of signing authority (see GSA 3516A, Solicitation Provisions) Small Business Subcontracting Plan, if applicable FAR 52.204-24, Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment Offeror’s Rate for Routine Cleaning and Disinfection Requirements

4.03 FIRE PROTECTION AND LIFE SAFETY SUBMITTALS (SMALL) (OCT 2020)

A. The Offeror must submit the Fire Protection and Life Safety (FPLS) Submittal Information in A.1 through A.5, unless the Building meets either exemption in sub-paragraph B or C below.

1. Completed GSA Form 12000, Prelease Fire Protection and Life Safety Evaluation for an Office Building (Part A or Part B, as applicable).

2. A copy of the previous year’s fire alarm system maintenance record showing compliance with the requirements in NFPA 72 (if a system is installed in the Building).

3. A copy of the previous year’s automatic fire sprinkler system maintenance record showing compliance with the requirements in NFPA 25

(if a system is installed in the Building).

RLP NO. 5VA0808, PAGE 5 GSA TEMPLATE R103 (10/24)

4. Computer generated plans set to 1/8" = 1'-0" (preferred). Plans submitted for consideration shall include floor plan(s) for which Space is being offered and floor plan(s) of the floor(s) of exit discharge (e.g., street level(s)). Each plan submitted shall include the locations of all exit stairs, elevators, and the Space(s) being offered to the Government. In addition, where Building exit stairs are interrupted or discontinued before the level of exit discharge, additional floor plans for the level(s) where exit stairs are interrupted or discontinued must also be provided.

5. A valid Building Certificate of Occupancy (C of O) issued by the local jurisdiction. If the Building C of O is not available or the local jurisdiction does not issue a Building C of O, provide a report prepared by a licensed fire protection engineer with their assessment of the Building regarding compliance with all applicable local Fire Protection and Life Safety-related codes and ordinances.

B. If the Space offered is 10,000 RSF or less in area and is located on the 1st floor of the Building, Offeror is not required to submit to GSA the Fire

Protection and Life Safety (FPLS) Submittal Information listed in A.1 through A.5 above.

C. If the Offeror provides a Building C of O obtained under any edition of the International Building Code (IBC), and the offered Space meets or will meet all the requirements of the Lease with regard to Means of Egress, Automatic Fire Sprinkler System, and Fire Alarm System prior to occupancy, then Offeror is not required to submit to GSA the FPLS Submittal Information in A.1 through A.5 above.

4.04 EISA SUBMITTALS (SMALL) (SEP 2015)

No later than the due date for final proposal revisions, the Offeror must submit to the LCO:

A. Evidence of an Energy Star® label obtained within the 12 months prior to the 12 date of final proposal revisions, or

B. If the offered existing building will not have an ENERGY STAR® label by the date of final proposal revisions, a written statement addressing which energy efficiency and conservation improvements (can be made to the building must be submitted. If no cost-effective improvements can be made, the Offeror must demonstrate to the Government using the ENERGY STAR® Online Tools why no energy efficiency and conservation improvements are cost effective. This explanation will be subject to review by the LCO. If the explanation is considered unreasonable, the offer may be considered technically unacceptable.

4.05 SWING SPACE - RLP (OCT 2022) INTENTIONALLY DELETED

GENERAL SERVICES ADMINISTRATION GSA FORM 3626 (REV 10/21)

U.S. GOVERNMENT LEASE FOR REAL PROPERTY

(Short Form)

1a. LEASE NUMBER

GS-03P-LVA01089

1b. BUILDING NUMBER

PART I - OFFER (Offeror completes Section A, C and D; Government shall complete Section B)

NOTE: All offers are subject to the terms and conditions outlined in Request for Lease Proposals No. 5VA0808 , Supplemental Lease Requirements document, General Clauses (GSA Form 3517A), and any other attachments included herein.

A. LOCATION AND DESCRIPTION OF PREMISES OFFERED FOR LEASE BY GOVERNMENT

1. NAME AND ADDRESS OF

BUILDING (Include nine-digit ZIP Code)

2. LOCATION(S) IN BUILDING

2a. FLOOR(S)

2b. ROOM NUMBER(S)

2e NUMBER OF PARKING SPACES

OFFERED

STRUCTURED 0

SURFACE 1

ANNUAL PARKING RATES (IF NOT

INCLUDED IN RATES UNDER PART C

BELOW)

STRUCTURED 0/space

SURFACE 0/space

2c. SQ. FT.

RENTABLE

ABOA

Common Area Factor

2d. TYPE

GENERAL OFFICE

WAREHOUSE

OTHER (Specify)

B. TERM

3a. To have and to hold the said Premises with its appurtenances for the term beginning upon acceptance of the Premises as required by this Lease and continuing for a period of ten (10) Years, three (3) Years Firm, subject to termination and renewal rights as may be hereinafter set forth. The commencement date of this Lease, along with any applicable termination and renewal rights, shall be more specifically set forth in a Lease Amendment upon substantial completion and acceptance of the Space by the Government.

3b. The Government may terminate this Lease, in whole or in parts, at any time effective after the Firm Term of this Lease, by providing not less than days prior written notice to the Lessor. The effective date of the termination shall be the day following the expiration of the required notice period or the termination date set forth in the notice, whichever is later. No rental shall accrue after the effective date of termination.

3c. This Lease may be renewed at the option of the Government for a term of YEARS at the rental rate(s) set forth below, provided notice is given to the Lessor at least days before the end of the original Lease term; all other terms and conditions of this Lease, as same may have been amended, shall remain in full force and effect during any renewal term.

C. RENTAL

4. Rent shall be payable in arrears and will be due on the first workday of each month. When the date for commencement of the lease falls after the 15th day of the month, the initial rental payment shall be due on the first workday of the second month following the commencement date. Rent for a period of less than a month shall be prorated. Rent shall not be adjusted for changes in real estate taxes or operating costs.

5a. AMOUNT OF ANNUAL RENT

5b. RATE PER MONTH

RENTAL RATE BREAKDOWN FIRM TERM

($/RSF/YEAR)

NON-FIRM TERM

($/RSF/YEAR)

RENEWAL TERM

($/RSF/YEAR)

6. BUILDING SHELL RENT

(INCL. REAL ESTATE TAXES)

6a. $

6b. Same as 6a 6c. $

7. OPERATING RENT 7a. $

7b. Same as 7a 7b. Same as 7a

8. TURNKEY TENANT

IMPROVEMENT RENT

(See blocks 12 and 13 below for additional breakdown of cost and amortization rate )

8a. $

8b. $0.00 8c. $0.00

9. BUILDING SPECIFIC

AMORTIZED CAPITAL (IF

APPLICABLE)

9a. $

9b. $0.00 9c. $0.00

10. TOTAL RENT 10a. $

10b. $ 10c. $

11. TENANT IMPROVEMENT COSTS

12. INTEREST RATE TO AMORTIZE TENANT

IMPROVEMENTS

GENERAL SERVICES ADMINISTRATION GSA FORM 3626 (REV 10/21)

13. HVAC OVERTIME RATE PER HOUR 14. ADJUSTMENT FOR VACANT PREMISES RATE

($/ABOA SF/YEAR)

D. OWNER IDENTIFICATION AND CERTIFICATION

15. RECORDED OWNER

15a. Name

15b. Unique Entity Identifier (UEI)

15c. Address

15d. City

15e. State

15f. ZIP + 4

16. BY SUBMITTING THIS OFFER, THE OFFEROR AGREES UPON ACCEPTANCE OF THIS PROPOSAL BY HEREIN SPECIFIED DATE, TO LEASE TO THE UNITED STATES OF AMERICA, THE PREMISES DESCRIBED, UPON THE TERMS AND CONDITIONS AS SPECIFIED HEREIN, IN FULL COMPLIANCE WITH AND ACCEPTANCE OF THE AFOREMENTIONED RLP, WITH ATTACHMENTS.

I have read the RLP with attachments in its entirety and am requesting no deviations

17. OFFEROR’S INTEREST IN PROPERTY

OWNER AUTHORIZED AGENT OTHER (Specify)

18. OFFEROR Check if same as Recorded Owner 18a. NAME

18b. ADDRESS

18c. CITY

18d. STATE

18e. ZIP + 4

18f. Title

18g. E-mail address

18h. Telephone Number

18i. OFFEROR’S SIGNATURE

18j. DATE SIGNED

PART II - AWARD (To be completed by Government)

1. Your offer is hereby accepted. This award consummates the Lease, which consists of the following attached documents: (a) this GSA Form 3626,

(b) Supplemental Lease Requirements, (c) Security Requirements, (d) Agency Specific Requirements, (e) Floor Plan delineating the Premises, (f) GSA Form 3517A, General Clauses (Acquisition of Leasehold Interests in Real Property for Small Leases), and (g) the following building improvements, changes or additions made or agreed to by you (for example, energy efficiency and conservation improvements, ABAAS upgrades, Seismic Form C - Building Retrofit or New Construction Pre-Award Commitment (if applicable)):

2. THIS DOCUMENT IS NOT BINDING ON THE GOVERNMENT OF THE UNITED STATES OF AMERICA UNLESS SIGNED BELOW BY

AUTHORIZED LEASE CONTRACTING OFFICER.

3a. NAME OF LEASE CONTRACTING OFFICER (Type or Print)

Mary Harris

3b. SIGNATURE OF LEASE

CONTRACTING OFFICER

3c. DATE

The information collection requirements contained in this Solicitation/Contract, that are not required by regulation, have been approved by the Office of Management and Budget pursuant to the Paperwork Reduction Act and assigned the OMB Control No. 3090-0086.

LEASE NO. GS-03P-LVA01089, PAGE 1 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE

REQUIREMENTS

REV (5/2025)

TABLE OF CONTENTS – SUPPLEMENTAL LEASE REQUIREMENTS

SECTION 1 GENERAL TERMS, CONDITIONS, AND STANDARDS

1.01 DEFINITIONS AND GENERAL TERMS (SMALL) (OCT 2023)

1.02 PUBLIC TRANSPORTATION (SMALL) (SEP 2015) INTENTIONALLY DELETED

1.03 AUTHORIZED REPRESENTATIVES (OCT 2016)

1.04 WAIVER OF RESTORATION (OCT 2023)

1.05 NOVATION AND CHANGE OF OWNERSHIP (SMALL) (OCT 2016)

1.06 ASBESTOS (SMALL) (MAY 2025)

1.07 ADJUSTMENT FOR VACANT PREMISES (SMALL) (OCT 2022)

1.08 ENTITY NAME (OCT 2023)

1.09 BUILDING IMPROVEMENTS

SECTION 2 CONSTRUCTION STANDARDS AND SHELL COMPONENTS

2.01 WORK PERFORMANCE (SMALL) (SEP 2015)

2.02 EXISTING FIT-OUT, SALVAGED, OR REUSED BUILDING MATERIAL (SMALL) (SEP 2015)

2.03 WOOD PRODUCTS (SMALL) (OCT 2023)

2.04 ADHESIVES AND SEALANTS (SMALL) (OCT 2020)

2.05 BUILDING SHELL REQUIREMENTS (SMALL) (OCT 2019)

2.06 RESPONSIBILITY OF THE LESSOR AND LESSOR’S ARCHITECT/ENGINEER (SMALL) (SEP 2015)

2.07 MEANS OF EGRESS (MAY 2015)

2.08 AUTOMATIC FIRE SPRINKLER SYSTEM (OCT 2023)

2.09 FIRE ALARM SYSTEM (SEP 2013)

2.10 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (SEP 2015)

2.11 ELEVATORS (SMALL) (OCT 2020) INTENTIONALLY DELETED

2.12 DEMOLITION (JUN 2012)

2.13 ACCESSIBILITY (OCT 2024)

2.14 CEILINGS (SMALL) (OCT 2019)

2.15 EXTERIOR AND COMMON AREA DOORS AND HARDWARE (SEP 2013)

2.16 WINDOWS (SMALL) (OCT 2020)

2.17 PARTITIONS: PERMANENT (SMALL) (OCT 2019)

2.18 INSULATION: THERMAL, ACOUSTIC, AND HVAC (SMALL) (OCT 2020)

2.19 PAINTING – SHELL (SMALL) (OCT 2020)

2.20 FLOORS AND FLOOR LOAD (SMALL) (OCT 2019)

2.21 MECHANICAL, ELECTRICAL, PLUMBING: GENERAL (SMALL) (SEP 2015)

2.22 DRINKING FOUNTAINS (MAY 2025) INTENTIONALLY DELETED

2.23 RESTROOMS (SMALL) (OCT 2022)

2.24 HEATING, VENTILATION, AND AIR CONDITIONING – SHELL (SMALL) (MAY 2025)

2.25 TELECOMMUNICATIONS: DISTRIBUTION AND EQUIPMENT (SMALL) (SEP 2015)

2.26 TELECOMMUNICATIONS: LOCAL EXCHANGE ACCESS (SMALL) (OCT 2020)

2.27 LIGHTING: INTERIOR AND PARKING – SHELL (SMALL) (OCT 2022)

2.28 INDOOR AIR QUALITY DURING CONSTRUCTION (SMALL) (OCT 2021)

2.29 NATIONAL HISTORIC PRESERVATION ACT REQUIREMENTS - LEASE (SMALL) (SEP 2015) INTENTIONALLY DELETED

SECTION 3 DESIGN, CONSTRUCTION, AND POST AWARD ACTIVITIES

3.01 SCHEDULE FOR COMPLETION OF SPACE (SMALL) (OCT 2020) INTENTIONALLY DELETED

3.02 ACCESS BY THE GOVERNMENT PRIOR TO ACCEPTANCE (SMALL) (OCT 2020)

3.03 ACCEPTANCE OF SPACE AND CERTIFICATE OF OCCUPANCY (SMALL) (OCT 2021)

3.04 LEASE TERM COMMENCEMENT DATE AND RENT RECONCILIATION (SMALL) (OCT 2021)

3.05 AS-BUILT DRAWINGS (OCT 2021)

3.06 SEISMIC RETROFIT (OCT 2020) INTENTIONALLY DELETED

3.07 GOVERNMENT PROJECT MANAGEMENT SYSTEM (MAY 2025) INTENTIONALLY DELETED

SECTION 4 TENANT IMPROVEMENT COMPONENTS INTENTIONALLY DELETED

4.01 TENANT IMPROVEMENTS AND PRICING (SMALL) (SEP 2015) INTENTIONALLY DELETED

4.02 FINISH SELECTIONS (SMALL) (SEP 2015) INTENTIONALLY DELETED

4.03 WINDOW COVERINGS (SMALL) (OCT 2020) INTENTIONALLY DELETED

4.04 DOORS: SUITE ENTRY (SMALL) (OCT 2020) INTENTIONALLY DELETED

4.05 DOORS: INTERIOR (SMALL) (OCT 2019) INTENTIONALLY DELETED

4.06 DOORS: HARDWARE (SMALL) (SEP 2015) INTENTIONALLY DELETED

4.07 PARTITIONS: SUBDIVIDING (SMALL) (OCT 2022) INTENTIONALLY DELETED

4.08 PAINTING – TI (SMALL) (OCT 2020) INTENTIONALLY DELETED

4.09 FLOOR COVERINGS AND PERIMETERS (SMALL) (OCT 2019) INTENTIONALLY DELETED

4.10 HEATING AND AIR CONDITIONING (SMALL) (OCT 2022) INTENTIONALLY DELETED

4.11 ELECTRICAL: DISTRIBUTION (SMALL) (SEP 2015) INTENTIONALLY DELETED

4.12 TELECOMMUNICATIONS: DISTRIBUTION AND EQUIPMENT (JUN 2012) INTENTIONALLY DELETED

4.13 TELECOMMUNICATIONS: LOCAL EXCHANGE ACCESS (AUG 2008) INTENTIONALLY DELETED

LEASE NO. GS-03P-LVA01089, PAGE 2 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE

4.14 DATA DISTRIBUTION (OCT 2020) INTENTIONALLY DELETED

4.15 ELECTRICAL, TELEPHONE, DATA FOR SYSTEMS FURNITURE (OCT 2022) INTENTIONALLY DELETED

4.16 LIGHTING: INTERIOR AND PARKING – TI (SMALL) (SEP 2015) INTENTIONALLY DELETED

SECTION 5 UTILITIES, SERVICES, AND OBLIGATIONS DURING THE LEASE TERM

5.01 PROVISION OF SERVICES, ACCESS, AND NORMAL HOURS (SMALL) (OCT 2020)

5.02 UTILITIES (SMALL) (OCT 2022)

5.03 HEATING AND AIR CONDITIONING (SMALL) (OCT 2024)

5.04 OVERTIME HVAC USAGE (SMALL) (SEP 2016)

5.05 JANITORIAL SERVICES (SMALL) (MAY 2025)

5.06 MAINTENANCE OF PROVIDED FINISHES (SMALL) (SEP 2015)

5.07 IDENTITY VERIFICATION OF PERSONNEL (OCT 2022)

5.08 RANDOLPH-SHEPPARD COMPLIANCE (SMALL) (SEP 2015)

5.09 INDOOR AIR QUALITY (MAY 2025)

5.10 RADON IN AIR (MAY 2025)

5.11 RADON IN WATER (MAY 2025) INTENTIONALLY DELETED

5.12 HAZARDOUS MATERIALS (MAY 2025)

5.13 MOLD AND WATER INTRUSION (OCT 2023)

5.14 OCCUPANT EMERGENCY PLANS (OCT 2020)

SECTION 6 ADDITIONAL TERMS AND CONDITIONS

6.01 SECURITY REQUIREMENTS (SMALL) (OCT 2019)

6.02 MODIFIED LEASE PARAGRAPHS (OCT 2016)

-1.09 BUILDING IMPROVEMENTS

-2.26 TELECOMMUNICATIONS: LOCAL EXCHANGE ACCESS (SMALL) (OCT 2020)

-5.03 HEATING AND AIR CONDITIONING (SMALL) (OCT 2024)

6.03 RENTAL CONSIDERATION FOR SMALL LEASES (OCT 2019)

6.04 SWING SPACE - LEASE (OCT 2022) INTENTIONALLY DELETED

LEASE NO. GS-03P-LVA01089, PAGE 1 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE

SECTION 1 GENERAL TERMS, CONDITIONS, AND STANDARDS

1.01 DEFINITIONS AND GENERAL TERMS (SMALL) (OCT 2023)

Unless otherwise specifically noted, all terms and conditions set forth in this Lease shall be interpreted by reference to the following definitions, standards, and formulas:

A. Real Property Terms.

1. “ANSI/BOMA” is an acronym for American National Standards Institute/Building Owners and Managers Association.

2. “ANSI/BOMA Occupant Area” or “ABOA” means the measurement standard (Z65.1-2017) provided by ANSI/BOMA for Occupant Area, which is “the total aggregated area used by an Occupant before Load Factors are applied, consisting of Tenant Area and Tenant Ancillary Area.” The Method A – Multiple Load Factor Method shall apply.

3. “Common Area Factor (CAF)” means a conversion factor determined and applied by the building owner to determine the rentable square feet for the leased space. The CAF is expressed as a percentage of the difference between the amount of rentable square feet (SF) and ABOA SF, divided by the ABOA SF. The CAF shall be determined in accordance with the applicable ANSI/BOMA standard for the type of space to which the CAF shall apply.

4. “Rentable Space or Rentable Square Feet (RSF)” means the area for which a tenant is charged rent. It is determined by the building owner and may vary by city or by building within the same city. Rentable space may include a share of common areas such as elevator lobbies, building corridors, and floor service areas. Floor service areas typically include restrooms, janitor rooms, telephone closets, electrical closets, and mechanical rooms. Rentable space does not include vertical building penetrations and their enclosing walls, such as stairs, elevator shafts, and vertical ducts. To determine the RSF, the ABOA SF is multiplied by the sum of one (1) plus the CAF, for each type of space included in the premises.

5. “Space” means that part of the premises to which the Government has exclusive use, such as occupant area, or other types of space.

Appurtenant areas (e.g., parking areas) to which the Government has rights under the lease are not included in the space.

1.02 PUBLIC TRANSPORTATION (SMALL) (SEP 2015) INTENTIONALLY DELETED

1.03 AUTHORIZED REPRESENTATIVES (OCT 2016)

Signatories to this Lease shall have full authority to bind their respective principals with regard to all matters relating to this Lease. No other persons shall be understood to have any authority to bind their respective principals except to the extent that such authority may be explicitly delegated by notice to the other party, or to the extent that such authority is transferred by succession of interest. The Government shall have the right to substitute its Lease Contracting Officer (LCO) by notice without an express delegation by the prior LCO.

1.04 WAIVER OF RESTORATION (OCT 2023)

Lessor shall have no right to require the Government to restore the Premises upon expiration or earlier termination (full or partial) of the Lease, and waives all claims against the Government for:

A. Waste, or, B. Damages or restoration arising from or related to:

1. The Government's normal and customary use of the Premises during the term of the Lease (including any extensions thereof), as well as

2. Any initial or subsequent alteration to the Premises regardless of whether such alterations are performed by the Lessor or by the

Government.

At its sole option, the Government may abandon property in the Space following expiration or earlier termination (full or partial) of the Lease, in which case the property will become the property of the Lessor, and the Government will be relieved of any liability in connection therewith.

1.05 NOVATION AND CHANGE OF OWNERSHIP (SMALL) (OCT 2016)

Consistent with GSAM 570.115, in the event of a transfer of ownership of the leased premises or a change in the Lessor’s legal name, FAR 42.12 applies.

1.06 ASBESTOS (SMALL) (MAY 2025)

The leased space shall be free of all asbestos containing materials, except undamaged asbestos flooring in the space or undamaged boiler or pipe insulation outside the space, in which case an asbestos management program conforming to Environmental Protection Agency guidance shall be implemented. The space shall be free of other hazardous materials and in compliance with applicable Federal, State, and local environmental laws and

LEASE NO. GS-03P-LVA01089, PAGE 2 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE regulations. If asbestos abatement work is to be performed in the Space after occupancy, the Lessor shall provide relocation and submit to the Government documentation that the abatement was done in accordance with OSHA (29 CFR § 1910.1001, 29 CFR § 1926.1101), EPA (40 CFR Part 61 - National Emission Standards for Hazardous Air Pollutants and Part 763), state, and local regulations and that final clearance is achieved.

1.07 ADJUSTMENT FOR VACANT PREMISES (SMALL) (OCT 2022)

If the Government fails to occupy any portion of the leased Premises or vacates the Premises in whole or in part prior to expiration of the term of the Lease, the operating costs paid by the Government as part of the rent rental rate shall be reduced using the “Adjustment for Vacant Premises Rate” specified on GSA Form 3626 of this Lease. This reduction shall occur after the Government gives 30 calendar days’ prior notice to the Lessor and shall continue in effect until the Lease expires or is terminated.

1.08 ENTITY NAME (OCT 2023)

Lessor may not use Federal agency name(s) and/or acronym(s), e.g., General Services Administration, GSA, in its entity name that owns and/or leases Space to GSA.

1.09 BUILDING IMPROVEMENTS

As part of shell rent, the Lessor shall complete the following Building Improvements:

A. Signage-Lessor shall provide one decal signage on the exterior entrance door of the Leased Space. The Government will provide exact specifications for the decal.

B. Ceiling Tile Replacement- Lessor shall inspect all ceiling tiles within the Lease Premises and replace any damaged, stained, or missing tiles with new tiles of the same type and quality as the existing ceiling tiles.

C. Suite Entrance Accessibility Upgrade- Lessor shall upgrade the Government’s suite entrances to fully comply with the Architectural Barriers Act Accessibility Standards (ABAAS) as detailed in Paragraph 2.13 “Accessibility” of this lease. This includes the removal of any steps at the entrance and the construction of a compliant ramp that adheres to ABAAS slope, width, and handrail requirements.

SECTION 2 CONSTRUCTION STANDARDS AND SHELL COMPONENTS

LEASE NO. GS-03P-LVA01089, PAGE 3 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE

2.01 WORK PERFORMANCE (SMALL) (SEP 2015)

All work in performance of this Lease shall be done by skilled and licensed workers or mechanics and shall be acceptable to the LCO.

2.02 EXISTING FIT-OUT, SALVAGED, OR REUSED BUILDING MATERIAL (SMALL) (SEP 2015)

The Lessor shall reuse items or materials in the construction phase of the project, as long as such meet the quality standards set forth by the Government in this Lease.

2.03 WOOD PRODUCTS (SMALL) (OCT 2023)

For all new installations of wood products, the Lessor is encouraged to use independently certified forest products. Refer to the Forest Stewardship Council United States (HTTPS://US.FSC.ORG/EN-US), or the Sustainable Forestry Initiative (HTTP://WWW.SFIPROGRAM.ORG/). Particle board, medium-density fiberboard, and hardwood plywood shall be free of formaldehyde and labeled as Toxic Substances Control Act (TSCA) Title VI compliant.

Other wood types such as strawboard shall be free of formaldehyde or sufficiently aged prior to use such that indoor air levels in the finished leased space shall not exceed 0.016 parts per million (ppm) of formaldehyde. All materials comprised of combustible substances, such as wood plywood and wood boards, shall be treated with fire retardant chemicals by a pressure impregnation process or other methods that treats the materials throughout as opposed to surface treatment.

2.04 ADHESIVES AND SEALANTS (SMALL) (OCT 2020)

All adhesives employed on this project (including, but not limited to, adhesives for carpet, carpet tile, plastic laminate, wall coverings, adhesives for wood, or sealants) shall meet the requirements of the manufacturer of the products adhered or involved. The Lessor shall use adhesives and sealants with no heavy metals and that do not result in indoor air levels above 0.016 parts per million (ppm) of formaldehyde. Adhesives and other materials used for the installation of carpets shall be limited to those having a flash point of 140 degrees F or higher.

2.05 BUILDING SHELL REQUIREMENTS (SMALL) (OCT 2019)

A. The Building Shell shall be designed, constructed, and maintained in accordance with the standards set forth herein and completed prior to acceptance of Space.

B. Base structure and Building enclosure components shall be complete. All common areas accessible by the Government, such as lobbies, fire egress corridors and stairwells, elevators, garages, and service areas, shall be complete. Restrooms shall be complete and operational. All newly installed Building shell components, including but not limited to, heating, ventilation, and air conditioning (HVAC), electrical, ceilings, sprinklers, etc., shall be furnished, installed, and coordinated with TIs. Circulation corridors are provided as part of the base Building only on multi-tenanted floors where the corridor is common to more than one tenant. On single tenant floors, only the fire egress corridor(s) necessary to meet code is provided as part of the shell.

C. The Building Shell rental rate shall also include, but is not limited to, insurance, taxes, lease commission and management, in addition to profit, reserve costs and loan financing for the Building.

2.06 RESPONSIBILITY OF THE LESSOR AND LESSOR’S ARCHITECT/ENGINEER (SMALL) (SEP 2015)

The Lessor remains solely responsible for designing, constructing, operating, and maintaining the leased premises in full accordance with the requirements of the Lease. The Lessor shall, without additional compensation, correct or revise any errors or deficiencies in its designs, drawings, specifications, or other services, as noted by the Government’s review or otherwise.

2.07 MEANS OF EGRESS (MAY 2015)

A. Prior to occupancy, the Premises and any parking garage areas shall meet or will be upgraded to meet either the applicable egress requirements in the National Fire Protection Association, Life Safety Code (NFPA 101) or the International Code Council, International Building Code (IBC), each current as of the Lease Award Date, or use an alternative approach or method that achieves an equivalent level of safety deemed acceptable by the Government.

B. The Space shall have unrestricted access to a minimum of two remote exits on each floor of Government occupancy.

C. Interlocking or scissor stairs located on the floor(s) where Space is located shall only count as one exit stair.

D. A fire escape located on the floor(s) where Space is located shall not be counted as an approved exit stair.

E. Doors shall not be locked in the direction of egress unless equipped with special locking hardware in accordance with requirements of NFPA

101 or the IBC.

2.08 AUTOMATIC FIRE SPRINKLER SYSTEM (OCT 2023)

A. Any portion of the Space located below-grade, including parking garage areas, and all areas in a Building referred to as "hazardous areas"

(defined in National Fire Protection Association (NFPA) 101) that are located within the entire Building (including non-Government areas) shall be protected by an automatic fire sprinkler system or an equivalent level of safety.

B. For Buildings in which any portion of the Space on or above the sixth floor, then, at a minimum, the Building up to and including the highest floor of Government occupancy shall be protected by an automatic fire sprinkler system or an equivalent level of safety.

https://us.fsc.org/en-us http://www.sfiprogram.org/

LEASE NO. GS-03P-LVA01089, PAGE 4 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE

C. For Buildings in which the Government occupies, either through this Lease or in combination with other Government Leases in the Building any portion of the Space is on or above the sixth floor, and lease of the Space will result, either individually or in combination with other Government Leases in the Building, in the Government leasing 35,000 or more ANSI/BOMA Occupant Area SF of Space in the Building, then the entire Building shall be protected throughout by an automatic fire sprinkler system or an equivalent level of safety.

D. Automatic fire sprinkler system(s) shall be installed in accordance with the requirements of NFPA 13, Standard for the Installation of Sprinkler

Systems that was in effect on the actual date of installation.

E. Automatic fire sprinkler system(s) shall be maintained in accordance with the requirements of NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-based Fire Protection Systems (current as of the Lease Award Date).

F. "Equivalent level of safety" means an alternative design or system (which may include automatic fire sprinkler systems), based upon fire protection engineering analysis, which achieves a level of safety equal to or greater than that provided by automatic fire sprinkler systems.

2.09 FIRE ALARM SYSTEM (SEP 2013)

A. A Building-wide fire alarm system shall be installed in the entire Building in which any portion of the Space is located on the 3rd floor or higher.

B. The fire alarm system shall be installed in accordance with the requirements of NFPA 72, National Fire Alarm and Signaling Code, that was in effect on the actual date of installation.

C. The fire alarm system shall be maintained in accordance with the requirements of NFPA 72, National Fire Alarm and Signaling Code (current as of the Lease Award Date).

D. The fire alarm system shall transmit all fire alarm signals to the local fire department via any of the following means: directly to the local fire department, to the (911) public communications center, to a central station, to a remote supervising station, or to a proprietary supervising station.

E. If the Building’s fire alarm control unit is over 25 years old as of the date of award of this Lease, Lessor shall install a new fire alarm system in accordance with the requirements of NFPA 72, National Fire Alarm and Signaling Code (current as of the Lease Award Date), prior to Government acceptance and occupancy of the Space.

2.10 ENERGY INDEPENDENCE AND SECURITY ACT (SMALL) (SEP 2015)

The Lessor shall either earn the ENERGY STAR® Label or complete all cost-effective energy efficiency and conservation improvements, agreed to by Lessor prior to acceptance of the Space (or not later than one year after the Lease Award Date of a succeeding or superseding Lease).

2.11 ELEVATORS (SMALL) (OCT 2020) INTENTIONALLY DELETED

2.12 DEMOLITION (JUN 2012)

The Lessor shall remove existing abandoned electric, telephone, and data cabling and devices, as well as any other improvements or fixtures in place to accommodate the Government’s requirements. Any demolition of existing improvements that is necessary to satisfy the Government’s layout shall be done at the Lessor’s expense.

2.13 ACCESSIBILITY (OCT 2024)

The Building, leased Space, and areas serving the leased Space shall be accessible to persons with disabilities in accordance with the Architectural Barriers Act Accessibility Standard (ABAAS), Appendices C and D to 36 CFR Part 1191 (ABA Chapters 1 and 2, and Chapters 3 through 10) and 36 CFR 1190 to the extent applicable. To the extent the standards referenced in the preceding sentence conflicts with local accessibility requirements, the more stringent shall apply.

2.14 CEILINGS (SMALL) (OCT 2019)

A complete acoustical ceiling system (which includes grid and lay-in tiles, or other Building standard ceiling system as approved by the LCO) throughout the Premises and all common areas accessible to Government tenants shall be required. The acoustical ceiling system shall be furnished, installed, and coordinated with TIs.

Ceilings shall be uniform in color and appearance throughout the Space, with no obvious damage to tiles or grid.

2.15 EXTERIOR AND COMMON AREA DOORS AND HARDWARE (SEP 2013)

A. Exterior Building doors and doors necessary to the lobbies, common areas, and core areas shall be required. This does not include suite entry or interior doors specific to TIs.

B. Exterior doors shall be weather tight and shall open outward. Hinges, pivots, and pins shall be installed in a manner which prevents removal when the door is closed and locked. These doors shall have a minimum clear opening of 32" clear wide x 80" high (per leaf). Doors shall be heavy duty, flush, 1) hollow steel construction, 2) solid core wood, or 3) insulated tempered glass. As a minimum requirement, hollow steel doors shall be fully insulated, flush, #16-gauge hollow steel. Solid-core wood doors and hollow steel doors shall be at least 1-3/4 inches thick. Door assemblies shall be of durable finish and shall have an aesthetically pleasing appearance acceptable to the LCO. The opening dimensions and

LEASE NO. GS-03P-LVA01089, PAGE 5 LESSOR: ________ GOVERNMENT: ________ SUPPLEMENTAL LEASE operations shall conform to the governing building, fire safety, accessibility, and energy codes and/or requirements. Fire door assemblies shall be listed and labeled. Labels on fire door assemblies shall be maintained in a legible condition. Fire door assemblies and their accompanying hardware, including frames and closing devices shall be installed in accordance with the requirements of NFPA 80, Standard for Fire Doors and Other Opening Protectives.

C. Exterior doors and all common area doors shall have door handles or door pulls with heavyweight hinges. All doors shall have corresponding doorstops (wall or floor mounted) and silencers. All public use doors and restroom doors shall be equipped with kick plates. All doors shall have automatic door closers. All Building exterior doors shall have locking devices installed to reasonably deter unauthorized entry.

2.16 WINDOWS (SMALL) (OCT 2020)

All exterior window assemblies shall be locked, weather resistant and watertight. Windows intended for use as a secondary means of egress must be openable from the egress side (e.g., inside) of the Building without the use of a key, tool, or special knowledge or effort for operation from the egress side.

2.17 PARTITIONS: PERMANENT (SMALL) (OCT 2019)

Permanent partitions shall extend from the structural floor slab to the structural ceiling slab, surrounding the Space, stairs, corridors, elevator shafts, restrooms, all columns, and janitor closets. They shall have a flame spread rating of 25 or less and a smoke development rating of 450 or less (ASTM E-84). Stairs, elevators, and other floor openings shall be enclosed by partitions and shall have the fire resistance required by the applicable building code, fire code and ordinances adopted by the jurisdiction in which the Building is located (such as the International Building Code, etc.) current as of the Lease Award Date.

2.18 INSULATION: THERMAL, ACOUSTIC, AND HVAC (SMALL) (OCT 2020)

A. No insulation installed with this project shall be material manufactured using chlorofluorocarbons (CFCs), nor shall CFCs be used in the installation of the product.

B. All insulation containing fibrous materials exposed to air flow shall be rated for that exposure or shall be encapsulated.

C. Insulating properties for all materials shall meet or exceed applicable industry standards. Polystyrene products shall meet American Society for

Testing and Materials (ASTM) C578 91.

D. All insulation shall contain low emitting volatiles and not result in indoor air levels above 0.016 parts per million (ppm) of formaldehyde.

E. The maximum flame spread and smoke developed index for insulation shall meet the requirements of the applicable local codes and ordinances

(current as of the Lease Award Date) adopted by the jurisdiction in which the Building is located.

2.19 PAINTING – SHELL (SMALL) (OCT 2020)

The Lessor shall bear the expense for all painting associated with the Building shell, including all common areas. Exterior perimeter walls and interior core walls within the Space shall be spackled and prime painted. If any Building shell areas are already painted prior to TIs, then the Lessor shall repaint, at the Lessor’s expense, as necessary during TIs.

2.20 FLOORS AND FLOOR LOAD (SMALL) (OCT 2019)

A. All adjoining floor areas shall be of a common level.

B. Under-floor surfaces shall be smooth and level. Office areas shall have a minimum live load capacity of 50 pounds per…